Plan Review Details - Permit 18061125
| Plan Review Stops For Permit 18061125 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-07-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-03 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-03 |
Time |
09:49 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-26 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-26 |
Time |
14:36 |
Sent To |
I |
|
| Notes |
| 2018-06-26 14:36:42 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. OCCUPANCY SENSORS HAVE BEEN REMOVED FROM SEVERAL | | | LOCATIONS. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING | | | CONTROLS STIPULATED IN THE FBC ENERGY CODE. FBC EC | | | C405.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-07-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-29 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2018-07-02 15:26:14 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-06-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2018-06-25 15:19:56 | REVISION ROUTED TO JPEARSON |
|
|
|
Account Summary | Usage Policy | Privacy Policy