| Plan Review Stops For Permit 18061031 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-26 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-26 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-15 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-15 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-30 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-30 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2018-07-30 12:49:22 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18061031 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC EB = FBC EXISTING BUILDING, 6TH EDITION (2017) | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION, 6TH EDITION (2017) | | | FBC R = FBC RESIDENTIAL, 6TH EDITION (2017) | | | | | | 1. [FBC 109.3]VALUATION IS LOW FOR NEW RESIDENTIAL | | | CONSTRUCTION. PROJECT VALUE HAS BEEN ADJUSTED USING ICC | | | BUILDING EVALUATION 2018. | | | | | | 2. [FBC R401.3]PROVIDE SITE PLAN TO INCLUDE DRAINAGE | | | PLAN ON THE SOUTH SIDE OF PROPERTY. | | | | | | 3. [FBC 107.2.5]PROVIDE SEDIMENT CONTROL PLAN FOR WORK | | | ADDITION WORK AREA. IT CAN BE PART OF SITE PLAN, OR IN | | | SEPARATE PLAN. | | | | | | 4. [FBC R402.2]SEE TABLE FOR COMPRESSIVE STRENGTH | | | MINIMUM. SHEETS A-1 AND A-3 SHOW 2000 PSI. PLEASE | | | VERIFY DESIGN VALUES PER TABLE. | | | | | | 5. [FBC ENERGY R401]HAVE OWNER OR OWNERS AGENT SIGN | | | ENERGY CALCS COVER SHEET BELOW THE PREPARER'S | | | SIGNATURE.' | | | | | | 6. [FBC R905.1.1] FOR ROOF SLOPES FROM TWO UNITS | | | VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN | | | FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), | | | DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. PLEASE ADD | | | TO PLANS AT SECTION AND ROOF PLAN. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-27 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-27 |
Time |
09:17 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-25 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-25 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2019-01-25 10:04:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. RISER DIAGRAM SHOWS THE SERVICE AS EXISTING ON A | | | STRUCTURE THAT IS NOT BUILT YET, SO OBVIOUSLY THIS IS | | | NOT EXISTING AND WILL BE TREATED AS A NEW SERVICE. | | | REMOVE IDENTIFICATION AS EXISTING. WPB FBC 107.2.1 | | | (PLAN AND RISER STILL SHOW ONE OF THE PANELS AS | | | EXISTING.) | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 (NOT PROVIDED.) | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECTS AND | | | PANELS. NEC 110.3, 110.9; FBC RE E3603.3 (NOT | | | PROVIDED.) | | | 10. CORRECTED. | | | 11. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-26 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-26 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2018-07-26 10:59:06 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NOTE 17 FOR AFCI COMPLIANCE IS NOT TO CODE. PER | | | CODE, ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 2. NOTE 21 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 3. PROVIDE LOCATION OF INTERIOR PANEL. WPB FBC 107.2.1 | | | 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. ONE SMOKE ALARM IS SHOWN LESS THAN 6 | | | FEET FROM A COOKING APPLIANCE. FOR THIS ALARM, PROVIDE | | | CORRECTION OF LOCATION AND SPECIFY TYPE PER FBC RE | | | R314.3.1. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 5. PROVIDE LOAD CALCULATION FOR ENTIRE SERVICE (BOTH | | | UNITS), INCLUDE EXISTING AND NEW LOADS TO CONFIRM | | | CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 | | | 6. RISER DIAGRAM SHOWS THE ELECTRICAL RISER CONTAINING | | | THREE 3/0 CONDUCTORS, WHICH IS RATED FOR 200 AMPS. | | | BASED ON THE LOAD CALCULATION OF ONE UNIT BEING 164 | | | AMPS, IT APPEARS THIS WIRE IS NOT SUFFICIENT TO HANDLE | | | THE LOAD. PROVIDE CORRECTION. NEC 215.2, 310.15(B)(16); | | | FBC RE E3602.1 | | | 7. RISER DIAGRAM SHOWS THE SERVICE AS EXISTING ON A | | | STRUCTURE THAT IS NOT BUILT YET, SO OBVIOUSLY THIS IS | | | NOT EXISTING AND WILL BE TREATED AS A NEW SERVICE. | | | REMOVE IDENTIFICATION AS EXISTING. WPB FBC 107.2.1 | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECTS AND | | | PANELS. NEC 110.3, 110.9; FBC RE E3603.3 | | | 10. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 11. LIGHT IN CLOSET IS NOT SPECIFIED. EITHER SPECIFY | | | TYPE OF FIXTURE, OR THAT ALL LIGHTING IN CLOSETS WILL | | | COMPLY WITH THE FOLLOWING CODE: NEC 410.16; FBC RE | | | E4003.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-08 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-08 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2019-03-08 14:04:08 | IMPACT FEES ROUTED TO DBATTLES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-02-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-15 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-29 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-14 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-21 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-08 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-08 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2019-03-08 16:44:55 | OK-STAMP ON PLANS | | | OK-RECEIPT | | | MU-2019-006580-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-15 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-15 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2019-01-15 15:03:41 | ONCE ALL REVIEWS ARE APPROVED YOU CAN CHECK OUT ONE SET | | | TO TAKE TO PBC IMPACT REVIEW. | | | | | | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-30 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-30 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2018-07-30 12:51:00 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES DUE, IF APPLICABLE, PROVIDED. | | | | | | AFTER ALL OTHER REVIEWS HAVE PASSED, CHECK OUT ONE SET | | | OF PLANS TO TAKE TO THE COUNTY. | | | | | | 561-233-5025 FOR MORE INFORMATION | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-29 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-25 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-08-02 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-08-02 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2018-08-02 14:21:15 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 RETURN AIR SHALL NOT BE TAKEN FROM KITCHEN, PER 2017 | | | FLORIDA BUILDING CODE - RESIDENTIAL SEC. M1602.2 RETURN | | | AIR OPENINGS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-24 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-24 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2019-01-24 15:05:31 | APPROVED | | | PROVISO | | | | | | 1. RE: TANK-LESS WATER HEATER; SUBMIT MANUFACTURER'S | | | SPECIFICATION SHEET TO INCLUDE THE MODEL NUMBER, GPM | | | AND ELECTRICAL CHARACTERISTICS FOR THE TANKLESS WATER | | | HEATERS PER WPB FBC 107.2.1 AND CONFIRM THEY WILL | | | SUPPLY THE HOT WATER DEMAND. SAID SPECIFICATION MAY BE | | | SUBMITTED AS A DEFERRED SUBMITTAL AS DEFINED BY WPB FBC | | | 107.3.4.1 AND SHALL BE SUBMITTED, APPROVED AND IN PLACE | | | PRIOR TO THE FIRST PLUMBING INSPECTION. | | | 2. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-14 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-14 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2018-08-14 18:18:59 | 08/14/2018 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ISOMETRIC DRAWING ON A-5 AND LAYOUT REQUIRE BRANCHES | | | AND STACKS THAT SHALL BE SIZED IN ACCORDANCE WITH TABLE | | | P3005.4.1. DIVIDE INTO BATHROOM GROUPS AND VENT EACH | | | GROUP AND RUN STACK OF WASHING MACHINE DOWNSTREAM FROM | | | FIRST BATHROOM GROUP, REFER TO 2017 FBC R3005.4. | | | 2. CLEAN OUT ARE NOT REQUIRED AT END OF RUN PER CODE. | | | 3. A THREE INCH (3") DRAIN LINE RECOMMENDED AT WASHING | | | MACHINE AS MOST MANUFACTURES REQUIRE BECAUSE OF THE | | | WATER DISCHARGE VOLUME IN NEW MODELS. | | | 4. TRUNK LINE MAYBE BEST RAN AWAY FROM SHOWER RECESS | | | BECAUSE OF DEPTH TO FINAL INVERT ELEVATION OUT OF | | | FOUNDATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-15 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-15 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-30 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-30 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2018-07-30 12:52:55 | PRODUCT APPROVAL GOOD FOR SHINGLES. | | | [FBC R905.1.1] FOR ROOF SLOPES FROM TWO UNITS VERTICAL | | | IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN FOUR UNITS | | | VERTICAL IN 12 UNITS HORIZONTAL (4:12), DOUBLE | | | UNDERLAYMENT APPLICATION IS REQUIRED. PLEASE ADD TO | | | PLANS AT SECTION AND ROOF PLAN. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-02-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-02-26 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-01-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-01-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-22 09:49:01 | *************************************ZONING REVIEW | | | FAILED***************************************** | | | | | | ARE THE EXISTING METERS JUST BEING RE-LOCATED OR ARE | | | THERE NEW METERS BEING ADDED? WHAT IS THE TOTAL AMOUNT | | | OF METERS ON PROPERTY? | | | | | | WHY DOES THE SURVEY HAVE THE TWO EXISTING STRUCTURES | | | LABELED AS "DUPLEX"? | | | | | | THERE IS A RECORD OF TWO UNITS FOR THIS PROPETY | | | (ACCORDING TO RENTAL RECORDS), SO TWO METERS IS THE | | | MAXIMUM AMOUNT OF METERS PERMITTED. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2018-06-28 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-06-28 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2018-06-28 11:35:56 | *******************************ZONING REVIEW | | | FAILED***************************************** | | | | | | PROVIDE THE REAR SETBACKS FOR THE ADDITION ON THE | | | SURVEY. | | | | | | ALANA WOOTEN | | | ASSOICATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | | | | |
|
|