Plan Review Details - Permit 18061031
Plan Review Stops For Permit 18061031
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-02-26 Cont ID  
Sent By dbattles Date 2019-02-26 Time 15:08 Rev Time 0.00
Received By dbattles Date 2019-02-26 Time 15:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-01-15 Cont ID  
Sent By dbattles Date 2019-01-15 Time 14:47 Rev Time 0.00
Received By dbattles Date 2019-01-15 Time 13:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By dbattles Date 2018-07-30 Time 12:48 Rev Time 0.00
Received By dbattles Date 2018-07-30 Time 08:01 Sent To  
Notes
2018-07-30 12:49:22****CORRECTIONS****
 W.P.B. PERMIT: 18061031
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6718
  
 FBC EB = FBC EXISTING BUILDING, 6TH EDITION (2017)
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION, 6TH EDITION (2017)
 FBC R = FBC RESIDENTIAL, 6TH EDITION (2017)
  
 1. [FBC 109.3]VALUATION IS LOW FOR NEW RESIDENTIAL
 CONSTRUCTION. PROJECT VALUE HAS BEEN ADJUSTED USING ICC
 BUILDING EVALUATION 2018.
  
 2. [FBC R401.3]PROVIDE SITE PLAN TO INCLUDE DRAINAGE
 PLAN ON THE SOUTH SIDE OF PROPERTY.
  
 3. [FBC 107.2.5]PROVIDE SEDIMENT CONTROL PLAN FOR WORK
 ADDITION WORK AREA. IT CAN BE PART OF SITE PLAN, OR IN
 SEPARATE PLAN.
  
 4. [FBC R402.2]SEE TABLE FOR COMPRESSIVE STRENGTH
 MINIMUM. SHEETS A-1 AND A-3 SHOW 2000 PSI. PLEASE
 VERIFY DESIGN VALUES PER TABLE.
  
 5. [FBC ENERGY R401]HAVE OWNER OR OWNERS AGENT SIGN
 ENERGY CALCS COVER SHEET BELOW THE PREPARER'S
 SIGNATURE.'
  
 6. [FBC R905.1.1] FOR ROOF SLOPES FROM TWO UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN
 FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12),
 DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. PLEASE ADD
 TO PLANS AT SECTION AND ROOF PLAN.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-02-27 Cont ID  
Sent By jpearson Date 2019-02-27 Time 09:17 Rev Time 0.00
Received By jpearson Date 2019-02-27 Time 09:17 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-01-25 Cont ID  
Sent By jpearson Date 2019-01-25 Time 10:04 Rev Time 0.00
Received By jpearson Date 2019-01-25 Time 08:02 Sent To  
Notes
2019-01-25 10:04:26CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED.
 2. CORRECTED.
 3. CORRECTED.
 4. CORRECTED.
 5. CORRECTED.
 6. CORRECTED.
 7. RISER DIAGRAM SHOWS THE SERVICE AS EXISTING ON A
 STRUCTURE THAT IS NOT BUILT YET, SO OBVIOUSLY THIS IS
 NOT EXISTING AND WILL BE TREATED AS A NEW SERVICE.
 REMOVE IDENTIFICATION AS EXISTING. WPB FBC 107.2.1
 (PLAN AND RISER STILL SHOW ONE OF THE PANELS AS
 EXISTING.)
 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10; FBC RE E3603.3 (NOT PROVIDED.)
 9. PROVIDE AIC RATING OF SERVICE DISCONNECTS AND
 PANELS. NEC 110.3, 110.9; FBC RE E3603.3 (NOT
 PROVIDED.)
 10. CORRECTED.
 11. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-26 Cont ID  
Sent By jpearson Date 2018-07-26 Time 10:59 Rev Time 0.00
Received By jpearson Date 2018-07-26 Time 07:28 Sent To  
Notes
2018-07-26 10:59:06CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NOTE 17 FOR AFCI COMPLIANCE IS NOT TO CODE. PER
 CODE, ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.12; FBC RE E3902.16
 2. NOTE 21 STATES THAT RECEPTACLES SHALL BE TAMPER
 RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT
 APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE
 CORRECTION. NEC 406.12; FBC RE E4002.14
 3. PROVIDE LOCATION OF INTERIOR PANEL. WPB FBC 107.2.1
 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. ONE SMOKE ALARM IS SHOWN LESS THAN 6
 FEET FROM A COOKING APPLIANCE. FOR THIS ALARM, PROVIDE
 CORRECTION OF LOCATION AND SPECIFY TYPE PER FBC RE
 R314.3.1. FBC RE R314.3, R315.1; WPB FBC 107.2.1
 5. PROVIDE LOAD CALCULATION FOR ENTIRE SERVICE (BOTH
 UNITS), INCLUDE EXISTING AND NEW LOADS TO CONFIRM
 CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220,
 408.30; FBC RE E3602.2
 6. RISER DIAGRAM SHOWS THE ELECTRICAL RISER CONTAINING
 THREE 3/0 CONDUCTORS, WHICH IS RATED FOR 200 AMPS.
 BASED ON THE LOAD CALCULATION OF ONE UNIT BEING 164
 AMPS, IT APPEARS THIS WIRE IS NOT SUFFICIENT TO HANDLE
 THE LOAD. PROVIDE CORRECTION. NEC 215.2, 310.15(B)(16);
 FBC RE E3602.1
 7. RISER DIAGRAM SHOWS THE SERVICE AS EXISTING ON A
 STRUCTURE THAT IS NOT BUILT YET, SO OBVIOUSLY THIS IS
 NOT EXISTING AND WILL BE TREATED AS A NEW SERVICE.
 REMOVE IDENTIFICATION AS EXISTING. WPB FBC 107.2.1
 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10; FBC RE E3603.3
 9. PROVIDE AIC RATING OF SERVICE DISCONNECTS AND
 PANELS. NEC 110.3, 110.9; FBC RE E3603.3
 10. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3
 11. LIGHT IN CLOSET IS NOT SPECIFIED. EITHER SPECIFY
 TYPE OF FIXTURE, OR THAT ALL LIGHTING IN CLOSETS WILL
 COMPLY WITH THE FOLLOWING CODE: NEC 410.16; FBC RE
 E4003.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-03-08 Cont ID  
Sent By dbattles Date 2019-03-08 Time 16:42 Rev Time 0.00
Received By dbattles Date 2019-03-08 Time 14:03 Sent To  
Notes
2019-03-08 14:04:08IMPACT FEES ROUTED TO DBATTLES

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2019-02-27 Time   Rev Time 0.00
Received By lmarchan Date 2019-02-15 Time 14:15 Sent To  
Notes
2019-02-19 14:16:36R01

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-29 Cont ID  
Sent By cthroop Date 2019-01-29 Time 09:25 Rev Time 0.00
Received By cthroop Date 2019-01-08 Time 14:52 Sent To  
Notes
2019-01-08 14:52:37R21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-14 Cont ID  
Sent By lcrespo Date 2018-08-14 Time 18:19 Rev Time 0.00
Received By lcrespo Date 2018-06-21 Time 14:58 Sent To  
Notes
2018-06-22 14:58:41R19

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2019-03-08 Cont ID  
Sent By dbattles Date 2019-03-08 Time 16:42 Rev Time 0.00
Received By dbattles Date 2019-03-08 Time 16:42 Sent To  
Notes
2019-03-08 16:44:55OK-STAMP ON PLANS
 OK-RECEIPT
 MU-2019-006580-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-01-15 Cont ID  
Sent By dbattles Date 2019-01-15 Time 14:49 Rev Time 0.00
Received By dbattles Date 2019-01-15 Time 14:49 Sent To  
Notes
2019-01-15 15:03:41ONCE ALL REVIEWS ARE APPROVED YOU CAN CHECK OUT ONE SET
 TO TAKE TO PBC IMPACT REVIEW.
  
 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By dbattles Date 2018-07-30 Time 12:50 Rev Time 0.00
Received By dbattles Date 2018-07-30 Time 12:49 Sent To  
Notes
2018-07-30 12:51:00IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
 THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING
 THAT FEES DUE, IF APPLICABLE, PROVIDED.
  
 AFTER ALL OTHER REVIEWS HAVE PASSED, CHECK OUT ONE SET
 OF PLANS TO TAKE TO THE COUNTY.
  
 561-233-5025 FOR MORE INFORMATION
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-29 Cont ID  
Sent By cthroop Date 2019-01-29 Time 09:25 Rev Time 0.00
Received By cthroop Date 2019-01-25 Time 14:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-08-02 Cont ID  
Sent By cmontell Date 2018-08-02 Time 14:23 Rev Time 0.00
Received By cmontell Date 2018-08-02 Time 14:00 Sent To  
Notes
2018-08-02 14:21:15MECHANICAL PLAN REVIEW FAIL
  
 1 RETURN AIR SHALL NOT BE TAKEN FROM KITCHEN, PER 2017
 FLORIDA BUILDING CODE - RESIDENTIAL SEC. M1602.2 RETURN
 AIR OPENINGS.
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-01-24 Cont ID  
Sent By jesmith Date 2019-01-24 Time 15:05 Rev Time 0.00
Received By jesmith Date 2019-01-24 Time 15:04 Sent To  
Notes
2019-01-24 15:05:31APPROVED
 PROVISO
  
 1. RE: TANK-LESS WATER HEATER; SUBMIT MANUFACTURER'S
 SPECIFICATION SHEET TO INCLUDE THE MODEL NUMBER, GPM
 AND ELECTRICAL CHARACTERISTICS FOR THE TANKLESS WATER
 HEATERS PER WPB FBC 107.2.1 AND CONFIRM THEY WILL
 SUPPLY THE HOT WATER DEMAND. SAID SPECIFICATION MAY BE
 SUBMITTED AS A DEFERRED SUBMITTAL AS DEFINED BY WPB FBC
 107.3.4.1 AND SHALL BE SUBMITTED, APPROVED AND IN PLACE
 PRIOR TO THE FIRST PLUMBING INSPECTION.
 2. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-08-14 Cont ID  
Sent By lcrespo Date 2018-08-14 Time 18:19 Rev Time 0.00
Received By lcrespo Date 2018-08-14 Time 17:22 Sent To  
Notes
2018-08-14 18:18:5908/14/2018 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ISOMETRIC DRAWING ON A-5 AND LAYOUT REQUIRE BRANCHES
 AND STACKS THAT SHALL BE SIZED IN ACCORDANCE WITH TABLE
 P3005.4.1. DIVIDE INTO BATHROOM GROUPS AND VENT EACH
 GROUP AND RUN STACK OF WASHING MACHINE DOWNSTREAM FROM
 FIRST BATHROOM GROUP, REFER TO 2017 FBC R3005.4.
 2. CLEAN OUT ARE NOT REQUIRED AT END OF RUN PER CODE.
 3. A THREE INCH (3") DRAIN LINE RECOMMENDED AT WASHING
 MACHINE AS MOST MANUFACTURES REQUIRE BECAUSE OF THE
 WATER DISCHARGE VOLUME IN NEW MODELS.
 4. TRUNK LINE MAYBE BEST RAN AWAY FROM SHOWER RECESS
 BECAUSE OF DEPTH TO FINAL INVERT ELEVATION OUT OF
 FOUNDATION.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-01-15 Cont ID  
Sent By dbattles Date 2019-01-15 Time 14:48 Rev Time 0.00
Received By dbattles Date 2019-01-15 Time 14:48 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By dbattles Date 2018-07-30 Time 12:56 Rev Time 0.00
Received By dbattles Date 2018-07-30 Time 12:56 Sent To  
Notes
2018-07-30 12:52:55PRODUCT APPROVAL GOOD FOR SHINGLES.
 [FBC R905.1.1] FOR ROOF SLOPES FROM TWO UNITS VERTICAL
 IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN FOUR UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (4:12), DOUBLE
 UNDERLAYMENT APPLICATION IS REQUIRED. PLEASE ADD TO
 PLANS AT SECTION AND ROOF PLAN.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2019-02-26 Cont ID  
Sent By awooten Date 2019-02-26 Time   Rev Time 0.00
Received By awooten Date 2019-02-26 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2019-01-22 Cont ID  
Sent By awooten Date 2019-01-22 Time   Rev Time 0.00
Received By awooten Date 2019-01-22 Time   Sent To  
Notes
2019-01-22 09:49:01*************************************ZONING REVIEW
 FAILED*****************************************
  
 ARE THE EXISTING METERS JUST BEING RE-LOCATED OR ARE
 THERE NEW METERS BEING ADDED? WHAT IS THE TOTAL AMOUNT
 OF METERS ON PROPERTY?
  
 WHY DOES THE SURVEY HAVE THE TWO EXISTING STRUCTURES
 LABELED AS "DUPLEX"?
  
 THERE IS A RECORD OF TWO UNITS FOR THIS PROPETY
 (ACCORDING TO RENTAL RECORDS), SO TWO METERS IS THE
 MAXIMUM AMOUNT OF METERS PERMITTED.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2018-06-28 Cont ID  
Sent By AW Date 2018-06-28 Time 11:34 Rev Time 0.00
Received By awooten Date 2018-06-28 Time 11:11 Sent To  
Notes
2018-06-28 11:35:56*******************************ZONING REVIEW
 FAILED*****************************************
  
 PROVIDE THE REAR SETBACKS FOR THE ADDITION ON THE
 SURVEY.
  
 ALANA WOOTEN
 ASSOICATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]
  
  