Plan Review Details - Permit 18061007
Plan Review Stops For Permit 18061007
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-09-16 Cont ID  
Sent By pvalenti Date 2018-09-16 Time 12:40 Rev Time 0.00
Received By pvalenti Date   Time   Sent To I
Notes
2018-09-16 12:10:37CHANGED VALUE FROM $15000 TO $49913 PER CONTRACT
 SUPPLIED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-08-13 Cont ID  
Sent By shill Date 2018-08-13 Time 13:57 Rev Time 0.00
Received By shill Date 2018-08-13 Time 13:57 Sent To  
Notes
2018-08-13 13:58:42****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS JOB. A
 COST BREAKDOWN MAY BE REQUIRED.
 THIS CAN BE SENT VIA EMAIL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-07 Cont ID  
Sent By shill Date 2018-07-07 Time 18:49 Rev Time 0.00
Received By shill Date 2018-07-07 Time 18:49 Sent To  
Notes
2018-07-07 18:49:48****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FS471.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-09-16 Cont ID  
Sent By jpearson Date 2018-09-16 Time 12:09 Rev Time 0.00
Received By jpearson Date 2018-09-16 Time 12:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-08-07 Cont ID  
Sent By jpearson Date 2018-08-07 Time 08:38 Rev Time 0.00
Received By jpearson Date 2018-08-07 Time 08:38 Sent To  
Notes
2018-08-07 08:38:01CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE SHOW WINDOW OUTLETS PER 210.62
 2. PLAN DOES NOT SHOW LOCATION OF MECHANICAL EQUIPMENT.
 PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C
 EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC
 210.63
 3. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS
 STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT
 SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2
 4. PROVIDE AUTOMATIC CONTROL FOR SIGN CIRCUIT. FBC EC
 405.2.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-11 Cont ID  
Sent By fgiaquin Date 2018-07-11 Time 05:38 Rev Time 0.00
Received By fgiaquin Date 2018-07-11 Time 05:26 Sent To  
Notes
2018-07-11 05:36:07ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NO ELECTRICAL WORK SHOWN ON SUBMITTED PLAN. NOTE #5
 IN "SCOPE OF WORK" STATES NEW SWITCHES, RECEPTACLES,
 SENSORS, ETC WILL BE INSTALLED. PROVIDE ELECTRICAL PLAN
 FOR REVIEW, SIGNED AND SEALED BY A LICENSED DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. IF
 THERE IS NOT ANY ELECTRICAL WORK INCLUDED WITH THIS
 PERMIT, STATE THAT ON PLAN. FS 471.003(2)(H); 471.025;
 WPB FBC 107.2.1, 107.3.5
  
 2, PLANS PREPARED BY AN ENGINEER MUST BE SIGNED AND
 SEALED. PE ONLY SIGNED PLANS. ELECTRICAL PLAN IS
 REQUIRED TO BE DESIGNED AND SIGNED/SEALED BY A DESIGN
 PROFESSIONAL. PROVIDE CORRECTION. FS 471.003(2)(H);
 471.025; WPB FBC 107.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WPB
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-07-24 Cont ID  
Sent By pleduc Date 2018-07-24 Time   Rev Time 0.00
Received By pleduc Date 2018-07-24 Time 10:01 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-06-27 Cont ID  
Sent By pleduc Date 2018-06-27 Time   Rev Time 0.00
Received By pleduc Date 2018-06-26 Time 16:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-09-16 Cont ID  
Sent By pvalenti Date 2018-09-16 Time 12:41 Rev Time 0.00
Received By pvalenti Date 2018-09-11 Time 10:13 Sent To I
Notes
2018-09-13 10:13:14RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-13 Cont ID  
Sent By shill Date 2018-08-13 Time 13:58 Rev Time 0.00
Received By shill Date 2018-07-19 Time 15:30 Sent To  
Notes
2018-07-20 15:30:41B20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-13 Cont ID  
Sent By jgomez Date 2018-07-11 Time 10:44 Rev Time 0.00
Received By jgomez Date 2018-06-22 Time 15:06 Sent To  
Notes
2018-07-13 10:45:05LAST REVIEW DONE ON 07/11/18 BY ELECTRICAL REVIEWER.
2018-06-25 15:07:19B21

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-07-27 Cont ID  
Sent By ccole Date 2018-07-27 Time 11:45 Rev Time 0.00
Received By ccole Date 2018-07-27 Time 11:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-06-27 Cont ID  
Sent By ccole Date 2018-06-27 Time 14:45 Rev Time 0.00
Received By ccole Date 2018-06-27 Time 14:45 Sent To  
Notes
2018-06-27 14:51:061ST REVIEW FBC-2017 MECHANICAL
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE MECHANICAL PLAN SHEET M-100.00 WHICH IS
 LISTED IN THE INDEX ON COVER SHEET T-100.00.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  