| Plan Review Stops For Permit 18060693 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-22 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-22 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-08 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-08 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-08 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2019-02-08 09:12:48 | *PROVISO* | | | | | | PROVIDE A REVISED SHEET A-1 WITH DESIGNER'S ORIGINAL | | | SIGNATURE, A COPY WILL NOT BE ACCEPTED. PLANS THAT HAVE | | | BEEN PREPARED BY AN ENGINEER AND SUBMITTED FOR PUBLIC | | | RECORD SHALL BEAR THE ORIGINAL SIGNATURE, DATE AND SEAL | | | OF THE ENGINEER PER FL ADMIN. CODE RULE 61G15-23.001. | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-30 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-29 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2018-10-30 18:05:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC A 206.2.2, PROVIDE THE SIZE OF THE TABLES. | | | | | | THIS CAN BE PROVIDED VIA EMAIL. CONTRACTOR WAS SENT AN | | | EMAIL BUT NO RESPONSE AT THIS TIME. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2018-09-02 14:55:24 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENT FROM PREVIOUS LIST NOT ADDRESSED: | | | | | | DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS, FS471. | | | | | | SHEET A1 APPEARS TO HAVE A PHOTOCOPY SIGNATURE AND IS | | | NOT SEALED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-07 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-07 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2018-07-07 18:29:52 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS, FS471. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-21 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-21 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-09 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-09 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-08-28 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-08-28 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2018-08-27 14:50:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. 600.5 | | | 2. OK | | | 3. OK | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-67 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-12 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-12 |
Time |
07:35 |
Sent To |
I |
|
| Notes |
| 2018-07-12 08:33:28 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE SHOW WINDOW OUTLETS PER CODE. THIS CANNOT BE | | | TIED TO SIGN CIRCUIT, WHICH IS REQUIRED TO BE A | | | DEDICATED CIRCUIT. NEC 210.62, 600.5 | | | 2. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT | | | SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2 | | | 3. PER THE WPB AMENDMENTS TO THE FBC, PLAN (BOTH | | | COPIES) IS REQUIRED TO BEAR THE NAME AND BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. | | | PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-03-11 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-03-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-10-09 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-10-09 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-06-27 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-06-27 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-25 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-05 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-30 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-02 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-07 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-14 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-21 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-21 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-22 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-22 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-23 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-23 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-26 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-26 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-25 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-25 |
Time |
06:03 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-23 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-23 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2018-10-23 14:06:37 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 3RD REVIEW: | | | PLUMBING COMMENTS: DENIED | | | PREVIOUS COMMENT NOT COMPLIED WITH. | | | | | | 4. PLEASE PROVIDE A COST BREAKDOWN TO SHOW COMPLIANCE | | | WITH FBC ACC 202.4, 202.4.1, 202.4.2 | | | WHEN EVER YOU ALTER A SPACE IT IS NECESSARY TO COMPLY | | | WITH THE ACCESSIBILITY CODE INCLUDING EXISTING ELEMENTS | | | BUT THE CODE ONLY REQUIRES THAT 20% OF THE OVERALL COST | | | OF THE JOB BE USED ON BRING UP THE LEVEL OF | | | ACCESSIBILITY. THE CODE LIST THE REQUIRED ELEMENTS THAT | | | SHALL COMPLY. THE COST BREAK PROVIDES DOCUMENTATION OF | | | HOW YOUR COMPLYING WITH THE ABOVE MENTIONED CODES. | | | PLEASE READ THESE CODE SECTIONS TO FAMILIARIZE YOURSELF | | | ON THIS SECTION OF THE CODE. FBC ACC 202.4, 202.4.1, | | | 202.4.2 | | | | | | | | | PLUMBING PROVISO | | | 1. HOT WATER IS REQUIRED FOR THE BREAKROOM SINK. PER | | | FBC PL 607.1; MISPRINT ON PLUMBING WATER ISOMETRIC. | | | NOTE THE REDLINE CORRECTION TO READ HW | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-31 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-31 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2018-08-31 11:58:51 | 1ST REVIEW: FBC 2017 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | PREVIOUS COMMENTS NOT COMPLIED WITH. | | | | | | 3. HOT WATER IS REQUIRED FOR THE BREAKROOM SINK. PER | | | FBC PL 607.1 | | | | | | 4. PLEASE PROVIDE A COST BREAKDOWN TO SHOW COMPLIANCE | | | WITH FBC ACC 202.4, 202.4.1, 202.4.2 | | | WHEN EVER YOU ALTER A SPACE IT IS NECESSARY TO COMPLY | | | WITH THE ACCESSIBILITY CODE INCLUDING EXISTING ELEMENTS | | | BUT THE CODE ONLY REQUIRES THAT 20% OF THE OVERALL COST | | | OF THE JOB BE USED ON BRING UP THE LEVEL OF | | | ACCESSIBILITY. THE CODE LIST THE REQUIRED ELEMENTS THAT | | | SHALL COMPLY. THE COST BREAK PROVIDES DOCUMENTATION OF | | | HOW YOUR COMPLYING WITH THE ABOVE MENTIONED CODES. | | | PLEASE READ THESE CODE SECTIONS TO FAMILIARIZE YOURSELF | | | ON THIS SECTION OF THE CODE. FBC ACC 202.4, 202.4.1, | | | 202.4.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-10 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-10 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2018-07-10 17:38:05 | 1ST REVIEW: FBC 2017 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE NEW SIDE GRAB BAR SHALL COMPLY WITH FBC ACC | | | 604.5.1 SIDE WALL.THE SIDE WALL GRAB BAR SHALL BE 42 | | | INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE | | | REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR | | | WALL. | | | | | | 2. THE BRANCH DRAIN FOR THE BREAKROOM SINK SHALL | | | CONNECT TO THE BUILDING DRAIN DOWN STREAM OF THE | | | EXISTING BATHROOM GROUP. PER FBC PL 912.1 | | | | | | 3. HOT WATER IS REQUIRED FOR THE BREAKROOM SINK. PER | | | FBC PL 607.1 | | | | | | 4. PLEASE PROVIDE A COST BREAKDOWN TO SHOW COMPLIANCE | | | WITH FBC ACC 202.4, 202.4.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | |
|
|