Plan Review Details - Permit 18060655
| Plan Review Stops For Permit 18060655 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-30 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-30 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-29 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-29 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-06-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-06-18 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-07-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-07-03 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2018-07-05 15:47:34 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-30 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-14 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-09 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-09 |
Time |
11:48 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-20 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-20 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2018-06-20 10:58:53 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18060655 | | | 6/20/18 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW 4-TON HEAT | | | PUMP IN THE OPEN WORK SPACE AREA. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |