| Notes |
| 2018-06-28 18:22:48 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE RAS 117 CALCULATIONS ARE REQUIRED TO HAVE THE | | | FLORIDA ENGINEER'S SEAL AND ORIGINAL HANDWRITTEN | | | SIGNATURE, COPIES OR OTHER FACSIMILES ARE NOT | | | ACCEPTABLE. FAC 61G15 - 23.002 DIGITAL SIGNATURES ARE | | | ONLY ACCEPTABLE FOR ELECTRONICALLY TRANSMITTED PLANS | | | AND DOCUMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-13 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-13 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2018-06-13 11:25:26 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ROOF COVERING ASSEMBLY THAT IS SELECTED ON PAGE | | | 33 OF NOA NO. 17-1004.09 IS DIFFERENT FROM THE ONE THAT | | | IS LISTED ON THE CONTRACT THAT WAS SUBMITTED. PLEASE | | | CLARIFY. FBC 107.2.1 | | | | | | 2) THE ASSEMBLY THAT MATCHES THE CONTRACT ON PAGE 10 | | | AND 11 OF THE NOA, HAS A DESIGN PRESSURE OF -52.5 PSF. | | | WHICH IS NOT ADEQUATE FOR A FLAT ROOF ON A STRUCTURE | | | WITH A 15' MEAN ROOF HEIGHT IN EXPOSURE C WITH A 170 | | | MPH VULT WIND SPEED. IF THIS ASSEMBLY IS TO BE USED, | | | SIGNED AND SEALED RAS 117 CALCULATIONS FOR ENHANCED | | | FASTENING WILL BE REQUIRED. SEE LIMITATION #7 ON PAGE | | | 34 OF THE NOA. FBC-R905.11.3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-28 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-27 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2018-06-28 13:12:25 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-02 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-02 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2018-07-02 11:10:47 | DOCUMENTS WITH ENGINEER'S ELECTRONIC STAMP AND | | | SIGNATURE WAS EMAILED AND HAS BEEN VERIFIED AND SENT TO | | | SCANNING. |
|
|
|