Plan Review Details - Permit 18060585
Plan Review Stops For Permit 18060585
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-08-29 Cont ID  
Sent By pvalenti Date 2018-08-29 Time 17:23 Rev Time 0.00
Received By pvalenti Date   Time   Sent To I
Notes
2018-08-29 17:24:06PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED PV

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-08-09 Cont ID  
Sent By pvalenti Date 2018-08-09 Time 08:27 Rev Time 0.00
Received By pvalenti Date   Time   Sent To I
Notes
2018-08-09 08:31:56****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC 107. THE CONTRACTOR STILL NEEDS TO FILL OUT THE
 SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE DEVICES
 OR ASSEMBLIES.
  
 NOTE: I HAVE LEFT (2) COPIES OF THE ABOVE NOTED FORMS.
 PLEASE TAKE THE TIME TO FILL OUT COMPLETELY AND
 RESUBMIT PERMIT APPLICATION. PV

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-15 Cont ID  
Sent By pvalenti Date 2018-06-15 Time 18:52 Rev Time 0.00
Received By pvalenti Date 2018-06-15 Time 18:51 Sent To  
Notes
2018-06-15 18:52:30****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION
 OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL
 INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL
 SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE
 NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON
 SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF
 USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON
 W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR).
  
 PLEASE CONTACT ME IF YOU NEED ASSISTANCE.
  
 3. FBC R 301.THE PROPOSED FASTENING THAT IS HIGHLIGHTED
 IS FOR CONCRETE. HOW HAVE YOU VERIFIED COLID CONCRETE
 AND NOT CONCRETE BLOCK? SEE PAGE 14A.
  
 4. FBC 109. VALUE TOO LOW, NEED TO INCLUDE VALUE OF
 CONTRACTOR'S INSTALLATION VALUE.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-08-29 Cont ID  
Sent By pvalenti Date 2018-08-29 Time 17:24 Rev Time 0.00
Received By pvalenti Date 2018-08-27 Time 12:40 Sent To I
Notes
2018-08-29 12:40:32RESUB ROUTED TO PVALENTI

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-09 Cont ID  
Sent By pvalenti Date 2018-08-09 Time 08:32 Rev Time 0.00
Received By pvalenti Date 2018-08-07 Time 13:29 Sent To I
Notes
2018-08-08 13:29:45RESUB ROUTED TO PVALENTI

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-15 Cont ID  
Sent By pvalenti Date 2018-06-15 Time 18:52 Rev Time 0.00
Received By pvalenti Date 2018-06-13 Time 10:25 Sent To  
Notes
2018-06-14 10:25:29BLDG <5K