Plan Review Details - Permit 18060580
| Plan Review Stops For Permit 18060580 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-11 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-07 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2019-06-11 16:07:46 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 5TH REVIEW BY THIS PLANS EXAMINER | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE COVER PAGE PER FBC R CHPT3 - BUILDING | | | PLANNING. INCLUDE THE FOLLOWING: (SEE ITEM K ) 3RD | | | REQUEST - CORRECTED | | | | | | K. FINISHED FLOOR ELEVATION - (R403.1.7.3 FOUNDATION | | | ELEVATION.CORRECTED - FINISH FLOOR ELEVATION HAS BEEN | | | ESTABLISHED AT 12.0 FEET. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN - CORRECTED | | | FBC R401.3 SITE DRAINAGE | | | | | | 3. VALUE - (ADJUSTED TO $551,070.00) (CORRECTED) | | | | | | NOTE: APPLICANT MAY PETITION ROBERT BROWN, B.O. FOR | | | ADJUSTMENT TO VALUE. | | | | | | 4. PROVIDE ENERGY SUBMITTAL - CORRECTED (U-FACTORS FOR | | | GLAZING TO BE VERIFIED IN FIELD) | | | (BUILDER TO SIGN EPL CARD, OWNER/AGENT TO SIGN ENERGY | | | SUBMITTAL) | | | | | | 5. PROVIDE WINDOW AND DOOR SCHEDULE. - NOT ADDRESSED - | | | 4TH REQUEST (DESIGN PRESSURES MAY BE PLACED ON PLANS | | | NEXT TO EACH OPENING IN LIEU OF WINDOW AND DOOR | | | SCHEDULE) | | | | | | R301.2.1 WIND DESIGN CRITERIA. (PROVIDE DESIGN | | | PRESSURES FOR EACH OPENING) | | | | | | 6. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. - | | | NOT ADDRESSED - 4TH REQUEST (SEE OPTION BELOW) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | (107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL.) | | | | | | | | | 7. OK | | | | | | 8. REFERENCE BOLT TENSIONING NOTE ON PLAN PAGE 009, 1 | | | OF 17. BOLTS ARE TO BE INSTALLED PER TURN OF THE NUT | | | METHOD. THIS INDICATES THE STRUCTURAL CONNECTIONS ARE | | | SLIP CRITICAL AND WILL REQUIRED A (THIRD PARTY | | | INSPECTOR) TO VERIFY BOLT INSTALLATION. | | | (SEE THRESHOLD REVIEW COMMENTS) 4TH REQUEST | | | | | | 9. PROVIDE SHOP DRAWINGS FOR SPIRAL STAIRCASE. ( | | | REMOVED FROM PLAN ) | | | | | | NEW COMMENTS | | | | | | 10. PLAN PAGES 008 THRU 025 FOR PRE-ENGINEERD METAL | | | BUILDING HAVE BEEN REVIEWED AND APPROVED. SIGNATURE AND | | | SEAL OF DESIGN PROFESSIONAL HAS BEEN VERIFIED. (SEE | | | SIGNATURE REVIEW COMMENTS) | | | | | | 11. PROVIDE FOUNDATION PLAN. CORRECTED | | | | | | 12. PROVIDE CONNECTION DETAIL FOR INTERIOR STAIRCASES. | | | CORRECTED | | | | | | 13. REFERENCE PLAN PAGE A-1. CORRECT GOVERNING CODE TO | | | 6TH ED 2017. CORRECTED | | | | | | 14. SPECIFY WHAT TYPE OF INSULATION WILL BE INSTALLED | | | TO OBTAIN REQUIRED R VALUE. | | | | | | 15. IN THE SUPPORTING DOCUMENTS THERE ARE SEVERAL | | | DUPLICATE PLAN PAGES. PLEASE REMOVE ANY DUPLICATE PAGES | | | IN PROJECT DOX. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | EXPIDITED PLAN REVIEW FEES WILL BE ASSESSED. | | | | | | ADDITIONAL FEES MAY APPLY AS FOLLOWS: | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-02 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2019-05-08 09:47:53 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW BY THIS PLANS EXAMINER | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE COVER PAGE PER FBC R CHPT3 - BUILDING | | | PLANNING. INCLUDE THE FOLLOWING: (SEE ITEM K ) 3RD | | | REQUEST | | | | | | K. FINISHED FLOOR ELEVATION - (R403.1.7.3 FOUNDATION | | | ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE). | | | | | | 2. PROVIDE SITE DRAINAGE PLAN - CORRECTED | | | FBC R401.3 SITE DRAINAGE | | | | | | 3. VALUE - (ADJUSTED TO $551,070.00) (CORRECTED) | | | | | | NOTE: APPLICANT MAY PETITION ROBERT BROWN, B.O. FOR | | | ADJUSTMENT TO VALUE. | | | | | | 4. PROVIDE ENERGY SUBMITTAL - (U-FACTORS FOR GLAZING TO | | | BE VERIFIED IN FIELD) | | | | | | 5. PROVIDE WINDOW AND DOOR SCHEDULE. - NOT ADDRESSED - | | | 3RD REQUEST (DESIGN PRESSURES MAY BE PLACED ON PLANS | | | NEXT TO EACH OPENING IN LIEU OF WINDOW AND DOOR | | | SCHEDULE) | | | | | | R301.2.1 WIND DESIGN CRITERIA. (PROVIDE DESIGN | | | PRESSURES FOR EACH OPENING) | | | | | | 6. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. - | | | NOT ADDRESSED - 3RD REQUEST (SEE OPTION BELOW) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | (107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL.) | | | | | | | | | 7. OK | | | | | | 8. REFERENCE BOLT TENSIONING NOTE ON PLAN PAGE 009, 1 | | | OF 17. BOLTS ARE TO BE INSTALLED PER TURN OF THE NUT | | | METHOD. THIS INDICATES THE STRUCTURAL CONNECTIONS ARE | | | SLIP CRITICAL AND WILL REQUIRED A (THIRD PARTY | | | INSPECTOR) TO VERIFY BOLT INSTALLATION. | | | (SEE THRESHOLD REVIEW COMMENTS) 3RD REQUEST | | | | | | 9. PROVIDE SHOP DRAWINGS FOR SPIRAL STAIRCASE. ( | | | REMOVED FROM PLAN ) | | | | | | NEW COMMENTS | | | | | | 10. PLAN PAGES 008 THRU 025 FOR PRE-ENGINEERD METAL | | | BUILDING HAVE BEEN REVIEWED AND APPROVED. SIGNATURE AND | | | SEAL OF DESIGN PROFESSIONAL HAS BEEN VERIFIED. (SEE | | | SIGNATURE REVIEW COMMENTS) | | | | | | 11. PROVIDE FOUNDATION PLAN. CORRECTED | | | | | | 12. PROVIDE CONNECTION DETAIL FOR INTERIOR STAIRCASES. | | | CORRECTED | | | | | | 13. REFERENCE PLAN PAGE A-1. CORRECT GOVERNING CODE TO | | | 6TH ED 2017. CORRECTED | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | EXPIDITED PLAN REVIEW FEES WILL BE ASSESSED. | | | | | | ADDITIONAL FEES MAY APPLY AS FOLLOWS: | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2019-04-23 09:52:10 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW BY THIS PLANS EXAMINER | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE COVER PAGE PER FBC R CHPT3 - BUILDING | | | PLANNING. INCLUDE THE FOLLOWING: SEE K BELOW | | | A. CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | B. ORIENTATION OF BUILDING TO NORTH. | | | C. EXPOSURE | | | D. RISK | | | E. DESIGN WIND LOADS | | | F. TYPE OF CONSTRUCTION | | | G. NUMBER OF FLOORS/BEDROOMS/BATHROOMS | | | H. SQUARE FOOTAGE - 1. CONDITIONED SPACE | | | 2. UNCONDITIONED SPACE | | | 3. TOTAL SQUARE FOOTAGE | | | I. SPRINKLER SYSTEM | | | J. SPECIAL FLOOD HAZARD AREA | | | | | | K. FINISHED FLOOR ELEVATION - (R403.1.7.3 FOUNDATION | | | ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE). | | | | | | L. DESIGN LIVE LOADS AND DESIGN DEAD LOADS. | | | M. DESIGN TEAM - | | | 1. ARCHITECT OF RECORD | | | 2. ENGINEER OF RECORD | | | 3. SPECIALTY ENGINEER | | | | | | 2. PROVIDE SITE DRAINAGE PLAN - CORRECTED | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 3. VALUE - (ADJUSTED TO $551,070.00) SEE NOTE BELOW | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | BASED ON THE CURRENT ICC BUILDING VALUATION DATA | | | PUBLISHED AUGUST 2018 THE VALUE OF THIS STRUCTURE HAS | | | BEEN DETERMINED TO BE ($551,070.00). | | | | | | NOTE: APPLICANT MAY PETITION ROBERT BROWN, B.O. FOR | | | ADJUSTMENT TO VALUE. | | | | | | 4. PROVIDE ENERGY SUBMITTAL - (ENERGY SUBMITTAL CANNOT | | | BE REVIEWED AT THIS TIME. SUBMIT MECHABICAL SYSTEM TO | | | BE INSTALLED TO PROVIDE HEATING AND COOLING WITH | | | EQUIPMENT SIZING CALCULATIONS. U-VALUES OF FENESTRATION | | | CANNOT BE DETERMINED AT THIS TIME DUE TO NO WINDOW | | | PRODUCT APPROVALS | | | SUBMITTED FOR REVIEW. R405.4.3ADDITIONAL DOCUMENTATION. | | | THE CODE OFFICIAL SHALL BE PERMITTED TO REQUIRE THE | | | FOLLOWING DOCUMENTS: | | | 1. 1.VERIFICATION THAT AN EPL DISPLAY CARD SIGNED BY | | | THE BUILDER PROVIDING THE BUILDING COMPONENT | | | CHARACTERISTICS OF THE PROPOSED DESIGN WILL BE PROVIDED | | | TO THE PURCHASER OF THE HOME AT TIME OF TITLE TRANSFER. | | | 2. 2.DOCUMENTATION OF THE COMPONENT EFFICIENCIES USED | | | IN THE SOFTWARE CALCULATIONS FOR THE PROPOSED DESIGN.) | | | | | | | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. ENERGY | | | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | _ OR _ | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | | NON-PRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | | FOUND IN APPENDIX C. | | | | | | 5. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE LOCATION | | | OF DEVICES ON PLAN. PROVIDE DESIGN PRESSURE FOR EACH | | | OPENING. - NOT ADDRESSED | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | 6. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. - | | | NOT ADDRESSED | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 7. OK | | | | | | 8. REFERENCE BOLT TENSIONING NOTE ON PLAN PAGE 009, 1 | | | OF 17. BOLTS ARE TO BE INSTALLED PER TURN OF THE NUT | | | METHOD. THIS INDICATES THE STRUCTURAL CONNECTIONS ARE | | | SLIP CRITICAL AND WILL REQUIRED A (THIRD PARTY | | | INSPECTOR) TO VERIFY BOLT INSTALLATION. | | | | | | 9. PROVIDE SHOP DRAWINGS FOR SPIRAL STAIRCASE. PROVIDE | | | FOUNDATION DETAIL AND ATTACHMENT DETAIL TO STRUCTURE. - | | | REMOVED FROM PLAN | | | | | | NEW COMMENTS | | | | | | 10. PLAN PAGES 008 THRU 025 FOR PRE-ENGINEERD METAL | | | BUILDING HAVE BEEN REVIEWED AND APPROVED. SIGNATURE AND | | | SEAL OF DESIGN PROFESSIONAL HAS BEEN VERIFIED. NO OTHER | | | SIGNATURE OR SEAL CAN BE VALIDAITED. | | | | | | 11. PROVIDE FOUNDATION PLAN. CORRECTED | | | | | | 12. PROVIDE CONNECTION DETAIL FOR INTERIOR STAIRCASES. | | | CORRECTED | | | | | | 13. REFERENCE PLAN PAGE A-1. CORRECT GOVERNING CODE TO | | | 6TH ED 2017. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | EXPIDITED PLAN REVIEW - DUE TO OUR CURRENT WORK LOAD, | | | REVIEWS WERE NOT EXPIDITED AND NO EXPIDITED FEE WILL BE | | | APPLIED TO THIS SUBMITTAL. SHOULD APPLICANT WISH TO | | | HAVE FUTURE REVIEWS EXPIDITED PLEASE FILL OUT A NEW | | | EXPIDITED PLAN REVIEW REQUEST FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-27 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-27 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2019-03-27 12:07:15 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE COVER PAGE PER FBC R CHPT3 - BUILDING | | | PLANNING. INCLUDE THE FOLLOWING: NOT ADDRESSED | | | A. CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | B. ORIENTATION OF BUILDING TO NORTH. | | | C. EXPOSURE | | | D. RISK | | | E. DESIGN WIND LOADS | | | F. TYPE OF CONSTRUCTION | | | G. NUMBER OF FLOORS/BEDROOMS/BATHROOMS | | | H. SQUARE FOOTAGE - 1. CONDITIONED SPACE | | | 2. UNCONDITIONED SPACE | | | 3. TOTAL SQUARE FOOTAGE | | | I. SPRINKLER SYSTEM | | | J. SPECIAL FLOOD HAZARD AREA | | | K. FINISHED FLOOR ELEVATION | | | L. DESIGN LIVE LOADS AND DESIGN DEAD LOADS. | | | M. DESIGN TEAM - | | | 1. ARCHITECT OF RECORD | | | 2. ENGINEER OF RECORD | | | 3. SPECIALTY ENGINEER | | | | | | 2. PROVIDE SITE DRAINAGE PLAN - NOT ADDRESSED | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 3. VALUE - (ADJUSTED TO $551,070.00) | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | BASED ON THE CURRENT ICC BUILDING VALUATION DATA | | | PUBLISHED AUGUST 2018 THE VALUE OF THIS STRUCTURE HAS | | | BEEN DETERMINED TO BE ($551,070.00). | | | | | | 4. PROVIDE ENERGY SUBMITTAL - NOT ADDRESSED | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. ENERGY | | | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | _ OR _ | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | | NON-PRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | | FOUND IN APPENDIX C. | | | | | | 5. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE LOCATION | | | OF DEVICES ON PLAN. PROVIDE DESIGN PRESSURE FOR EACH | | | OPENING. - NOT ADDRESSED | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | 6. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. - | | | NOT ADDRESSED | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 7. OK | | | | | | 8. REFERENCE BOLT TENSIONING NOTE ON PLAN PAGE 009, 1 | | | OF 17. BOLTS ARE TO BE INSTALLED PER TURN OF THE NUT | | | METHOD. THIS INDICATES THE STRUCTURAL CONNECTIONS ARE | | | SLIP CRITICAL AND WILL REQUIRED A (THIRD PARTY | | | INSPECTOR) TO VERIFY BOLT INSTALLATION. | | | | | | 9. PROVIDE SHOP DRAWINGS FOR SPIRAL STAIRCASE. PROVIDE | | | FOUNDATION DETAIL AND ATTACHMENT DETAIL TO STRUCTURE. - | | | NOT ADDRESSED | | | | | | NEW COMMENTS | | | | | | 10. PLAN PAGES 008 THRU 025 FOR PRE-ENGINEERD METAL | | | BUILDING HAVE BEEN REVIEWED AND APPROVED. SIGNATURE AND | | | SEAL OF DESIGN PROFESSIONAL HAS BEEN VERIFIED. | | | | | | 11. PROVIDE FOUNDATION PLAN. | | | | | | 12. PROVIDE CONNECTION DETAIL FOR INTERIOR STAIRCASES. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2019-02-06 13:51:14 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | 1. PROVIDE COVER PAGE PER FBC R CHPT3 - BUILDING | | | PLANNING. INCLUDE THE FOLLOWING: | | | A. CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | B. ORIENTATION OF BUILDING TO NORTH. | | | C. EXPOSURE | | | D. RISK | | | E. DESIGN WIND LOADS | | | F. TYPE OF CONSTRUCTION | | | G. NUMBER OF FLOORS/BEDROOMS/BATHROOMS | | | H. SQUARE FOOTAGE - 1. CONDITIONED SPACE | | | 2. UNCONDITIONED SPACE | | | 3. TOTAL SQUARE FOOTAGE | | | I. SPRINKLER SYSTEM | | | J. SPECIAL FLOOD HAZARD AREA | | | K. FINISHED FLOOR ELEVATION | | | L. DESIGN LIVE LOADS AND DESIGN DEAD LOADS. | | | M. DESIGN TEAM - | | | 1. ARCHITECT OF RECORD | | | 2. ENGINEER OF RECORD | | | 3. SPECIALTY ENGINEER | | | | | | 2. PROVIDE SITE DRAINAGE PLAN - | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 3. VALUE - | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | BASED ON THE CURRENT ICC BUILDING VALUATION DATA | | | PUBLISHED AUGUST 2018 THE VALUE OF THIS STRUCTURE HAS | | | BEEN DETERMINED TO BE $543,375.00. | | | | | | 4. PROVIDE ENERGY SUBMITTAL - | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. ENERGY | | | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | _ OR _ | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | | NON-PRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | | FOUND IN APPENDIX C. | | | | | | 5. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE LOCATION | | | OF DEVICES ON PLAN. PROVIDE DESIGN PRESSURE FOR EACH | | | OPENING. | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | 6. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 7. REFERENCE PLAN PAGE A-1. PROVIDE DETAIL FOR FOOTINGS | | | F-1 AND F-2. PLEASE CLARIFY WHAT F002 REFERS TO. | | | | | | 8. REFERENCE BOLT TENSIONING NOTE ON PLAN PAGE 009, 1 | | | OF 17. BOLTS ARE TO BE INSTALLED PER TURN OF THE NUT | | | METHOD. THIS INDICATES THE STRUCTURAL CONNECTIONS ARE | | | SLIP CRITICAL AND WILL REQUIRED A SPECIAL INSPECTOR TO | | | VERIFY BOLT INSTALLATION. | | | | | | 9. PROVIDE SHOP DRAWINGS FOR SPIRAL STAIRCASE. PROVIDE | | | FOUNDATION DETAIL AND ATTACHMENT DETAIL TO STRUCTURE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-06 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-06 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2019-02-05 09:06:55 | PLAN WAS PULLED FROM REVIEW. SPOKE WITH ENGINEER; PLANS | | | ARE SEVERELY DEFICIENT AND HE WAS NOT FAMILIAR WITH THE | | | PROJECT TO PROVIDE CLARIFICATION, SO PULLED FROM | | | REVIEW. | | | | | | | | 2018-09-06 10:44:43 | ***PLAN REVIEW IN PROGESS*** | | | | | | ***CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PLEASE HAVE THE ENGINEER CONTACT ME. I HAVE LEFT A | | | MESSAGE FOR HIM ON THE NUMBER I FOUND ON THE INTERNET. | | | ANOTHER NUMBER I HAVE FOR HIM (845-496-6610) IS | | | DISCONNECTED. | | | | | | WITHOUT BASIC INFORMATION, AN ACCURATE PLAN REVIEW | | | CANNOT BE DONE. PLANS STATE "REVIEWED BY" SO IT IS NOT | | | CLEAR IS IT IS DESIGNED BY THE ENGINEER. PLAN STATES IT | | | IS 3 STORIES, BUT IT IS 4 STORIES. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-14 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-14 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2018-06-14 17:33:28 | ***CORRECTIONS**** | | | REVISED 6/28/18 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. THE VALUE ON THE APPLICATION IS TOO LOW; FBC 109, | | | VALUE HAS BEEN ADJUSTED (ESTIMATED) PER ICC TABLES. | | | | | | 2. PLAN REVIEW FEE WAS NOT PAID AT TIME OF SUBMITTAL, | | | BUT WAS SUBSEQUENTLY PAID. | | | | | | 3. FBC 107, THE PLAN SUBMITTED IS DEFICIENT, SO WE ARE | | | UNABLE TO DO A PLAN REVIEW AT THIS TIME. FOR INSTANCE: | | | SOME AREAS DO NOT INCLUDE ROOM DESIGNATIONS - FOR | | | EXAMPLE, DRAWING 9 HAS AREAS WITH NO ROOM DESIGNATIONS | | | NO FOUNDATION DETAIL | | | MAIN ENTRY DOOR NOT CLEAR | | | CANNOT DETERMINE MEANS OF EGRESS FROM FLOOR TO FLOOR; | | | NOT CLEAR IF STAIR IS THE ONLY ACCESS, STAIR APPEARS TO | | | BE LOCATED IN THE PORCH RATHER THAN INSIDE OF THE UNIT | | | FIRST FLOOR MAIN ENTRY DOOR APPEARS TO ENTER INTO A | | | BEDROOM | | | NO FIRE RESISTANT RATED WALLS OR FLOORS SHOWN | | | SHAFTS, EXITS NOT SHOWN | | | | | | FOR INFORMATION REQUIRED FOR PLAN REVIEW, SEE CITY OF | | | WEST PALM BEACH MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS, FBC 107.3.5, AS APPLICABLE. FOR YOUR | | | CONVENIENCE, THAT CODE SECTION IS PROVIDED FOR YOU AT | | | THE END OF THIS REVIEW. | | | | | | 4. NA. | | | | | | 5. APPLICANT HAS COMPLETED THE OWNER BUILDER AFFIDAVIT. | | | CONFIRM THAT THE TWO UNITS PROPOSED WILL NOT BE SOLD, | | | RENTED, LEASED, OR ADVERTISED FOR SALE, RENT, OR LEASE | | | FOR AT LEAST A YEAR AFTER COMPLETION. | | | | | | * * * * * * * * * * * * * * * | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1: | | | | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | | EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL | | | SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND | | | DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION PLAN; | | | FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS: | | | | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 1. SITE REQUIREMENTS: | | | PARKING | | | FIRE ACCESS | | | VEHICLE LOADING | | | DRIVING/TURNING RADIUS | | | FIRE HYDRANT/WATER SUPPLY/POST INDICATOR VALVE (PIV) | | | SET BACK/SEPARATION (ASSUMED PROPERTY LINES) | | | LOCATION OF SPECIFIC TANKS, WATER LINES AND SEWER LINES | | | FLOOD HAZARD AREAS, FLOOD ZONES, AND DESIGN FLOOD | | | ELEVATIONS | | | PROPOSED ELEVATION CERTIFICATE FOR STRUCTURES IN A | | | SPECIAL FLOOD HAZARD AREA | | | 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | | SHALL BE DETERMINED. | | | 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED | | | (SEE TABLE SECTION 503). | | | 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING COMPONENTS: | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | FIRE BLOCKING AND DRAFT STOPPING AND CALCULATED FIRE | | | RESISTANCE | | | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | | EARLY WARNING SMOKE EVACUATION SYSTEMS | | | SCHEMATIC FIRE SPRINKLERS | | | STANDPIPES | | | PRE-ENGINEERED SYSTEMS | | | RISER DIAGRAM | | | 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL | | | INCLUDE THE FOLLOWING | | | REQUIREMENTS: | | | OCCUPANT LOAD AND EGRESS CAPACITIES | | | EARLY WARNING | | | SMOKE CONTROL | | | STAIR PRESSURIZATION | | | SYSTEMS SCHEMATIC | | | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | CONSTRUCTION REQUIREMENTS | | | HORIZONTAL EXITS/EXIT PASSAGEWAYS | | | 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | SOIL CONDITIONS/ANALYSIS | | | TERMITE PROTECTION | | | DESIGN LOADS | | | WIND REQUIREMENTS | | | BUILDING ENVELOPE | | | STRUCTURAL CALCULATIONS (IF REQUIRED) | | | FOUNDATION | | | FLOOD REQUIREMENTS IN ACCORDANCE WITH SECTION 1612, | | | INCLUDING LOWEST FLOOR | | | ELEVATIONS, ENCLOSURES, FLOOD DAMAGE-RESISTANT | | | MATERIALS | | | WALL SYSTEMS | | | FLOOR SYSTEMS | | | ROOF SYSTEMS | | | THRESHOLD INSPECTION PLAN | | | STAIR SYSTEMS | | | 9. MATERIALS SHALL BE REVIEWED AND SHALL AT A MINIMUM | | | INCLUDE THE FOLLOWING: | | | WOOD | | | STEEL | | | ALUMINUM | | | CONCRETE | | | PLASTIC | | | GLASS | | | MASONRY | | | GYPSUM BOARD AND PLASTER | | | INSULATING (MECHANICAL) | | | ROOFING | | | INSULATION | | | 10. ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE | | | FOLLOWING: | | | SITE REQUIREMENTS | | | ACCESSIBLE ROUTE | | | VERTICAL ACCESSIBILITY | | | TOILET AND BATHING FACILITIES | | | DRINKING FOUNTAINS | | | EQUIPMENT | | | SPECIAL OCCUPANCY REQUIREMENTS | | | FAIR HOUSING REQUIREMENTS | | | 11. INTERIOR REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) | | | LIGHT AND VENTILATION | | | SANITATION | | | 12. SPECIAL SYSTEMS: | | | ELEVATORS | | | ESCALATORS | | | LIFTS | | | 13. LOCATION AND INSTALLATION DETAILS. THE SPECIFIC | | | LOCATION AND INSTALLATION DETAILS OF EACH | | | FIRE DOOR, FIRE DAMPER, CEILING DAMPER AND SMOKE DAMPER | | | SHALL BE SHOWN AND PROPERLY | | | IDENTIFIED ON THE BUILDING PLANS BY THE DESIGNER | | | 107.3.5.1.2 ELECTRICAL | | | 1. ELECTRICAL: | | | WIRING | | | SERVICES | | | FEEDERS AND BRANCH CIRCUITS | | | OVERCURRENT PROTECTION | | | GROUNDING | | | WIRING METHODS AND MATERIALS | | | GFCLS | | | 2. EQUIPMENT | | | 3. SPECIAL OCCUPANCIES | | | 4. EMERGENCY SYSTEMS | | | 5. COMMUNICATION SYSTEMS | | | 6. LOW VOLTAGE | | | 7. LOAD CALCULATIONS | | | 8. DESIGN FLOOD ELEVATION | | | 107.3.5.1.3 PLUMBING | | | 1. MINIMUM PLUMBING FACILITIES | | | 2. FIXTURE REQUIREMENTS | | | 3. WATER SUPPLY PIPING | | | 4. SANITARY DRAINAGE | | | 5. WATER HEATERS | | | 6. VENTS | | | 7. ROOF DRAINAGE | | | 8. BACK FLOW PREVENTION | | | 9. IRRIGATION | | | 10. LOCATION OF WATER SUPPLY LINE | | | 11. GREASE TRAPS | | | 12. ENVIRONMENTAL REQUIREMENTS | | | 13. PLUMBING RISER | | | 14. DESIGN FLOOD ELEVATION | | | 107.3.5.1.4 MECHANICAL | | | 1 . ENERGY CALCULATIONS | | | 2 . EXHAUST SYSTEMS: | | | CLOTHES DRYER EXHAUST | | | KITCHEN EQUIPMENT EXHAUST | | | SPECIALTY EXHAUST SYSTEMS | | | 3. EQUIPMENT | | | 4. EQUIPMENT LOCATION | | | 5. MAKE-UP AIR | | | 6. ROOF-MOUNTED EQUIPMENT | | | 7. DUCT SYSTEMS | | | 8. VENTILATION | | | 9. COMBUSTION AIR | | | 10. CHIMNEYS, FIREPLACES AND VENTS | | | 11. APPLIANCES | | | 12. BOILERS | | | 13. REFRIGERATION | | | 14. BATHROOM VENTILATION | | | 15. LABORATORY | | | 16. DESIGN FLOOD ELEVATION | | | 107.3.5.1.5 GAS | | | 1. GAS PIPING | | | 2. VENTING | | | 3. COMBUSTION AIR | | | 4. CHIMNEYS AND VENTS | | | 5. APPLIANCES | | | 6. TYPE OF GAS | | | 7. FIREPLACES | | | 8. LP TANK LOCATION | | | 9. RISER DIAGRAM/SHUTOFFS | | | 10. DESIGN FLOOD ELEVATION | | | 107.3.5.1.6 ENERGY CALCULATIONS | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2019-06-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-13 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-13 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2019-06-13 09:30:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: 6TH REVIEW, DENIED, SEE | | | COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. RISER DIAGRAM PROVIDED BUT NEEDS CORRECTIONS. SEE | | | NEW COMMENTS. | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (6TH REVIEW: LOAD | | | CALCULATION IS NOT ACCURATE, SEE PREVIOUS COMMENTS.) | | | 3. PANEL SCHEDULES PROVIDED BUT NOT CORRECT. SEE | | | COMMENTS BELOW. | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | (6TH REVIEW: NOT PROVIDED.) | | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3606.3 (6TH REVIEW, AIC | | | RATING OF ELECRTICAL EQUIPMENT STILL NOT PROVIDED.) | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (6TH | | | REVIEW: NOT PROVIDED.) | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (6TH | | | REVIEW: NOT PROVIDED.) | | | 11. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | (6TH REVIEW: NOT PROVIDED.) | | | 12. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 (6TH REVIEW: NOT PROVIDED. IN ADDITION, THE | | | 20 AMP SMALL APPLIANCE CIRCUITS SHALL HAVE NO OTHER | | | OUTLETS. NEC 210.52(B)(2)) | | | 13. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (5TH REVIEW: NOT | | | CORRECTED.) | | | 14. PLAN DOES NOT SHOW THE 20 AMP RECEPTACLE IN THE | | | LAUNDRY REQUIRED PER CODE. PROVIDE CORRECTION. NEC | | | 210.52(F); FBC RE E3901.8 (6TH REVIEW: NOT TO CODE.) | | | 15. CORRECTED. | | | 16. CORRECTED. | | | 17. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 (6TH REVIEW: NOT PROVIDED COMPLETELY. WHERE | | | IS THE METER CAN LOCATED? SHOW ON PLAN.) | | | 18. CORRECTED. | | | 19. CORRECTED. | | | 20. CORRECTED. | | | 21. CORRECTED. | | | 22. CORRECTED. | | | 23. LOAD CALCULATION DOES NOT MATCH THE METHOD IN FBC | | | RESIDENTIAL OR THE NEC, WHICHEVER WOULD APPLY DEPENDING | | | ON SERVICE TYPE. PROVIDE A RESIDENTIAL LOAD CALCULATION | | | THAT INCLUDES ALL LOADS AND DEMAND FACTORS AS | | | PERMITTED. PROVIDE ACCURATE LOAD CALCULATION INCLUDING | | | ALL LOADS TO MATCH THE TYPE OF SERVICE. NEC 220; FBC RE | | | E3602.2 (6TH REVIEW, NOT PROVIDED ACCURATELY.) | | | 24. CORRECTED. | | | 25. CORRECTED. | | | 26. CORRECTED. | | | 27. PANEL SCHEDULES SHOW 10 GAUGE WIRE ON A 32 AMP | | | BREAKER IN SEVERAL LOCATIONS. THIS IS NOT A STANDARD | | | BREAKER SIZE, AND THE WIRE SIZE IS NOT PERMITTED TO BE | | | USED ON A BREAKER OVER 30 AMPS. PROVIDE CORRECTION. NEC | | | 240.4(D), 240.6, 310.15(B)(16) (NOT CORRECTED.) | | | 28. NEW PLAN SHEETS SUBMITTED HAVE THE SAME NAME: | | | EL-100.01. PLAN SHEETS NEED TO HAVE DISTINCT NAMES. | | | PROVIDE CORRECTION. WPB FBC 107.2.1 (NOT CORRECTED.) | | | 29. PROVIDE SPEC SHEET FOR 32 AMP BREAKER AS THIS IS | | | NOT A STANDARD SIZE BREAKER. NEC 240.6 (NOT PROVIDED.) | | | 30. PROVIDE SPEC SHEET FOR 160 AMP BREAKER AS THIS IS | | | NOT A STANDARD SIZE BREAKER. NEC 240.6 (NOT PROVIDED.) | | | | | | END OF COMMENTS. | | | | | | BE ADVISED THAT THERE IS A SUBSTANTIAL AMOUNT OF | | | INFORMATION MISSING ON THE SUBMITTED PLAN. UPON NEXT | | | REVIEW, FURTHER COMMENTS ARE POSSIBLE. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2019-05-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-31 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-31 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2019-05-31 07:38:18 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. RISER DIAGRAM PROVIDED BUT NEEDS CORRECTIONS. SEE | | | NEW COMMENTS. | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (5TH REVIEW: LOAD | | | CALCULATION IS NOT ACCURATE, SEE NEW COMMENTS.) | | | 3. PANEL SCHEDULES PROVIDED BUT NOT CORRECT. SEE NEW | | | COMMENTS BELOW. | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | (5TH REVIEW: NOT PROVIDED.) | | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3606.3 (5TH REVIEW, AIC | | | RATING OF ELECRTICAL EQUIPMENT STILL NOT PROVIDED.) | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (5TH | | | REVIEW: NOT PROVIDED.) | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (5TH | | | REVIEW: NOT PROVIDED.) | | | 11. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | (5TH REVIEW: NOT PROVIDED.) | | | 12. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 (5TH REVIEW: NOT PROVIDED. IN ADDITION, THE | | | 20 AMP SMALL APPLIANCE CIRCUITS SHALL HAVE NO OTHER | | | OUTLETS. NEC 210.52(B)(2)) | | | 13. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (5TH REVIEW: NOT | | | CORRECTED.) | | | 14. PLAN DOES NOT SHOW THE 20 AMP RECEPTACLE IN THE | | | LAUNDRY REQUIRED PER CODE. PROVIDE CORRECTION. NEC | | | 210.52(F); FBC RE E3901.8 (5TH REVIEW: NOT TO CODE.) | | | 15. CORRECTED. | | | 16. CORRECTED. | | | 17. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 (5TH REVIEW: NOT PROVIDED COMPLETELY. WHERE | | | IS THE METER CAN LOCATED? SHOW ON PLAN.) | | | 18. FOUR TIMES PLAN REVIEW FEE ADDED. | | | | | | NEW COMMENTS: | | | | | | 19. CORRECTED. | | | 20. CORRECTED. | | | 21. CORRECTED. | | | 22. CORRECTED. | | | 23. LOAD CALCULATION DOES NOT MATCH THE METHOD IN FBC | | | RESIDENTIAL OR THE NEC, WHICHEVER WOULD APPLY DEPENDING | | | ON SERVICE TYPE. PROVIDE A RESIDENTIAL LOAD CALCULATION | | | THAT INCLUDES ALL LOADS AND DEMAND FACTORS AS | | | PERMITTED. PROVIDE ACCURATE LOAD CALCULATION INCLUDING | | | ALL LOADS TO MATCH THE TYPE OF SERVICE. NEC 220; FBC RE | | | E3602.2 (5TH REVIEW, NOT PROVIDED ACCURATELY.) | | | 24. CORRECTED. | | | 25. CORRECTED. | | | 26. CORRECTED. | | | 27. PANEL SCHEDULES SHOW 10 GAUGE WIRE ON A 32 AMP | | | BREAKER IN SEVERAL LOCATIONS. THIS IS NOT A STANDARD | | | BREAKER SIZE, AND THE WIRE SIZE IS NOT PERMITTED TO BE | | | USED ON A BREAKER OVER 30 AMPS. PROVIDE CORRECTION. NEC | | | 240.4(D), 240.6, 310.15(B)(16) (NOT CORRECTED.) | | | 28. NEW PLAN SHEETS SUBMITTED HAVE THE SAME NAME: | | | EL-100.01. PLAN SHEETS NEED TO HAVE DISTINCT NAMES. | | | PROVIDE CORRECTION. WPB FBC 107.2.1 | | | 29. PROVIDE SPEC SHEET FOR 32 AMP BREAKER AS THIS IS | | | NOT A STANDARD SIZE BREAKER. NEC 240.6 | | | 30. PROVIDE SPEC SHEET FOR 160 AMP BREAKER AS THIS IS | | | NOT A STANDARD SIZE BREAKER. NEC 240.6 | | | | | | END OF COMMENTS. | | | | | | BE ADVISED THAT THERE IS A SUBSTANTIAL AMOUNT OF | | | INFORMATION MISSING ON THE SUBMITTED PLAN. UPON NEXT | | | REVIEW, FURTHER COMMENTS ARE POSSIBLE. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2019-05-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-07 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-06 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2019-05-07 07:05:38 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. RISER DIAGRAM PROVIDED BUT NEEDS CORRECTIONS. SEE | | | NEW COMMENTS. | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (4TH REVIEW: LOAD | | | CALCULATION IS NOT ACCURATE, SEE NEW COMMENTS.) | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 (4TH | | | REVIEW: PANEL SCHEDULE FOR LPP-FF NOT PROVIDED. OTHER | | | PANEL SCHEDULES NEED CORRECTION, SEE NEW COMMENTS.) | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | (4TH REVIEW: NOT PROVIDED.) | | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3606.3 (NOT PROVIDED.) | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (4TH REVIEW: NOT PROVIDED.) | | | 7. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (4TH REVIEW: NOT PROVIDED.) | | | 8. CORRECTED. | | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (4TH | | | REVIEW: NOT PROVIDED.) | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (4TH | | | REVIEW: NOT PROVIDED.) | | | 11. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | (4TH REVIEW: NOT PROVIDED.) | | | 12. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 (4TH REVIEW: NOT PROVIDED. IN ADDITION, THE | | | 20 AMP SMALL APPLIANCE CIRCUITS SHALL HAVE NO OTHER | | | OUTLETS. NEC 210.52(B)(2)) | | | 13. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (4TH REVIEW: NOT | | | CORRECTED.) | | | 14. PLAN DOES NOT SHOW THE 20 AMP RECEPTACLE IN THE | | | LAUNDRY REQUIRED PER CODE. PROVIDE CORRECTION. NEC | | | 210.52(F); FBC RE E3901.8 (4TH REVIEW: NOT TO CODE.) | | | 15. CORRECTED. | | | 16. CORRECTED. | | | 17. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 (4TH REVIEW: NOT PROVIDED COMPLETELY. WHERE | | | IS THE METER CAN LOCATED? SHOW ON PLAN.) | | | 18. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE NEXT | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | AGAIN FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW | | | IS REQUIRED. FLORIDA STATUTES STATE: WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | THE ADDITIONAL FEE FOR THIS PROJECT WOULD BE $8,816.04 | | | | | | NEW COMMENTS: | | | | | | 19. RISER DIAGRAM SHOWS THERE IS A 3 PHASE, 120/240 | | | VOLT SERVICE. THIS TYPE OF SERVICE WOULD HAVE A HIGH | | | LEG AND SHOULD BE DESIGNED ACCORDINGLY. IF THIS IS | | | ACCURATE, MANY LOCATIONS SHOW SINGLE PHASE LOADS ON THE | | | HIGH LEG OF THE PANELS, WHICH IS A CODE VIOLATION. IF | | | THERE IS A HIGH LEG SERVICE, PROVIDE DETAILS OF MARKING | | | OF THE HIGH LEG PER CODE. PROVIDE CLARIFICATION AND/OR | | | CORRECTIONS AS NEEDED. NEC 110.3, 110.15; WPB FBC | | | 107.2.1 | | | 20. IF THIS IS A THREE PHASE SERVICE, THE FBC | | | RESIDENTIAL DOES NOT APPLY. PROVIDE CLARIFICATION. WPB | | | FBC 107.2.1 | | | 21. RISER DIAGRAM SHOWS WHAT APPEARS TO BE PANEL MDB | | | HAVING CIRCUIT BREAKERS FEEDING LOADS. HOWEVER, THERE | | | IS NOMENCLATURE AT EACH OF THE BREAKERS THAT INDICATE | | | THESE ARE FUSED DISCONNECTS. WHICH IS IT? PROVIDE | | | CLARIFICATION AND/OR CORRECTIONS AS NEEDED. | | | 22. RISER DIAGRAM SHOWS THE WIRE FROM FPL AS HAVING 4 | | | CONDUCTORS THE SAME SIZE, AND A CONDUCTOR MARKED ?E?. | | | IT APPEARS THIS IS AN EQUIPMENT GROUNDING CONDUCTOR. | | | THIS CONDUCTOR SHOULD NOT BE INCLUDED IN THE SERVICE | | | DROP. IS THIS SERVICE UNDERGROUND OR OVERHEAD? PROVIDE | | | CLARIFICATIONS AND/OR CORRECTIONS. NEC 250.6; WPB FBC | | | 107.2.1 | | | 23. LOAD CALCULATION DOES NOT MATCH THE METHOD IN FBC | | | RESIDENTIAL OR THE NEC, WHICHEVER WOULD APPLY DEPENDING | | | ON SERVICE TYPE. PROVIDE A RESIDENTIAL LOAD CALCULATION | | | THAT INCLUDES ALL LOADS AND DEMAND FACTORS AS | | | PERMITTED. THE CURRENT NUMBERS SUPPLIED FOR VA ARE NOT | | | EXPLAINED, AND THEN THESE NUMBERS ARE DIVIDED BY THE | | | SINGLE PHASE VOLTAGE TO DETERMINE THE AMPERAGE | | | REQUIREMENT. SEE NOTES 19 AND 20, IS THIS A 3 PHASE OR | | | SINGLE PHASE SERVICE? PROVIDE ACCURATE LOAD CALCULATION | | | INCLUDING ALL LOADS TO MATCH THE TYPE OF SERVICE. NEC | | | 220; FBC RE E3602.2 | | | 24. PANEL MDB SHOWS 3/0 WIRE FEEDING PANEL LPP-GF, FED | | | FROM A 250 AMP BREAKER. THIS WIRE IS NOT RATED FOR 250 | | | AMPS. PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE | | | E3705.1 | | | 25. PANEL MDB SHOWS 4/0 WIRE FEEDING PANEL LPP-FF, FED | | | FROM A 300 AMP BREAKER. THIS WIRE IS NOT RATED FOR 300 | | | AMPS. PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE | | | E3705.1 | | | 26. PANEL LPP-GF SHOWS 14 GAUGE WIRE ON A 16 AMP | | | BREAKER IN SEVERAL LOCATIONS. THIS IS NOT A STANDARD | | | BREAKER SIZE, AND THE WIRE SIZE IS NOT PERMITTED TO BE | | | USED ON A BREAKER OVER 15 AMPS. PROVIDE CORRECTION. NEC | | | 240.4(D), 240.6, 310.15(B)(16) | | | 27. PANEL LPP-GF SHOWS 10 GAUGE WIRE ON A 32 AMP | | | BREAKER IN SEVERAL LOCATIONS. THIS IS NOT A STANDARD | | | BREAKER SIZE, AND THE WIRE SIZE IS NOT PERMITTED TO BE | | | USED ON A BREAKER OVER 30 AMPS. PROVIDE CORRECTION. NEC | | | 240.4(D), 240.6, 310.15(B)(16) | | | | | | END OF COMMENTS. | | | | | | BE ADVISED THAT THERE IS A SUBSTANTIAL AMOUNT OF | | | INFORMATION MISSING ON THE SUBMITTED PLAN. UPON NEXT | | | REVIEW, FURTHER COMMENTS ARE POSSIBLE. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-05 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-05 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2019-04-05 13:15:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 (NOT PROVIDED.) | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (NOT PROVIDED.) | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 (NOT | | | PROVIDED.) | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | (NOT PROVIDED.) | | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3606.3 (NOT PROVIDED.) | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (NOT PROVIDED.) | | | 7. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (NOT PROVIDED.) | | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (NOT | | | PROVIDED.) | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (NOT | | | PROVIDED.) | | | 11. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | (NOT PROVIDED.) | | | 12. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 (NOT PROVIDED.) | | | 13. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (NOT PROVIDED.) | | | 14. PLAN DOES NOT SHOW THE 20 AMP RECEPTACLE IN THE | | | LAUNDRY REQUIRED PER CODE. PROVIDE CORRECTION. NEC | | | 210.52(F); FBC RE E3901.8 (NOT PROVIDED.) | | | 15. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 (NOT PROVIDED.) | | | 16. CORRECTED. | | | 17. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 (NOT PROVIDED.) | | | | | | BE ADVISED THAT THERE IS A SUBSTANTIAL AMOUNT OF | | | INFORMATION MISSING ON THE SUBMITTED PLAN. UPON NEXT | | | REVIEW, FURTHER COMMENTS ARE POSSIBLE. | | | | | | NEW COMMENT: | | | | | | 18. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE NEXT | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | AGAIN FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW | | | IS REQUIRED. FLORIDA STATUTES STATE: WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | THE ADDITIONAL FEE FOR THIS PROJECT WOULD BE $8,816.04 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-07 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-07 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2019-03-07 14:45:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 (NOT PROVIDED.) | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (NOT PROVIDED.) | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 (NOT | | | PROVIDED.) | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | (NOT PROVIDED.) | | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3606.3 (NOT PROVIDED.) | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 (NOT PROVIDED.) | | | 7. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (NOT PROVIDED.) | | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (NOT | | | PROVIDED.) | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (NOT | | | PROVIDED.) | | | 11. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | (NOT PROVIDED.) | | | 12. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 (NOT PROVIDED.) | | | 13. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (NOT PROVIDED.) | | | 14. PLAN DOES NOT SHOW THE 20 AMP RECEPTACLE IN THE | | | LAUNDRY REQUIRED PER CODE. PROVIDE CORRECTION. NEC | | | 210.52(F); FBC RE E3901.8 (NOT PROVIDED.) | | | 15. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 (NOT PROVIDED.) | | | 16. CORRECTED. | | | 17. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 (NOT PROVIDED.) | | | | | | BE ADVISED THAT THERE IS A SUBSTANTIAL AMOUNT OF | | | INFORMATION MISSING ON THE SUBMITTED PLAN. UPON NEXT | | | REVIEW, FURTHER COMMENTS ARE POSSIBLE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-05 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-05 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2019-02-05 11:02:20 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3606.3 | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 7. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 11. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | 12. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 | | | 13. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 | | | 14. PLAN DOES NOT SHOW THE 20 AMP RECEPTACLE IN THE | | | LAUNDRY REQUIRED PER CODE. PROVIDE CORRECTION. NEC | | | 210.52(F); FBC RE E3901.8 | | | 15. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | 16. PROVIDE LOCATION OF ALL ELECTRICAL PANELS ON PLAN | | | TO CONFIRM CODE COMPLIANCE. WPB FBC 107.2.1 | | | 17. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 | | | | | | BE ADVISED THAT THERE IS A SUBSTANTIAL AMOUNT OF | | | INFORMATION MISSING ON THE SUBMITTED PLAN. UPON NEXT | | | REVIEW, FURTHER COMMENTS ARE POSSIBLE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
N |
Date |
2019-03-06 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-03-06 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-03-06 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
N |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-02-01 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-02-01 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2019-02-01 13:26:47 | PERMIT #18060580 | | | FIRE COMMENTS | | | | | | PER DISCUSSION WITH MS. TERRY MAUNEY, THE PROPERTY | | | OWNER, A FIRE REVIEW IS NOT REQUIRED, AS THIS PERMIT IS | | | FOR A STRUCTURE THAT IS TO BE USED SOLELY AS A SINGLE | | | FAMILY HOME. | | | MS. MAUNEY STATED AND CONFIRMED THAT THERE WILL BE NO | | | SECONDARY USE TO THIS STRUCTURE THAT WOULD NEED TO BE | | | REVIEWED UNDER THE FIRE CODE. THIS INCLUDES BUSINESS, | | | RESIDENTIAL BOARD | | | AND CARE, AND/OR ROOMING HOUSE OCCUPANCIES. MS. TAUNEY, | | | STATED THAT THE ONLY USE OF THE PROPERTY WILL BE AS A | | | PERMANENT RESIDENTIAL SINGLE FAMILY HOME. | | | | | | SUE ELLEN CALDERON | | | ASST. FIRE MARSHAL | | | WPBFD | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2019-01-23 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-01-23 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-01-23 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2019-01-23 09:54:45 | PERMIT # 18060580 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 2ND REVIEW - FAIL COMMENTS | | | | | | THIS SUBMISSION APPEARS TO BE MISSING SHEETS AND | | | DETAILS THAT WERE IN THE ORIGINAL SUBMISSION. IT DOES | | | NOT APPEAR THAT ANY OF THE COMMENTS HAVE BEEN | | | ADDRESSED. | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | 2) THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.3 | | | OF NFPA 101 FLORIDA EDITION 2015. FOR NON-SEPARATED | | | MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE | | | SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO | | | THE BUILDING. | | | | | | 3) SHEET CS1.0: PROVIDE CORRECT NUMBER OF STORIES. | | | | | | 4) PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | | | | 5) SHEET F2.01: PROVIDE LOCKING KNOX CAPS ON FIRE | | | DEPARTMENT CONNECTION. | | | | | | 6) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | 7) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION | | | SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | | MAY BE GENERATED DURING PLAN RESUBMISSION. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-13 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-13 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2018-09-13 15:14:58 | PERMIT # 18060580 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | 2) THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.3 | | | OF NFPA 101 FLORIDA EDITION 2015. FOR NON-SEPARATED | | | MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE | | | SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO | | | THE BUILDING. | | | | | | 3) SHEET CS1.0: PROVIDE CORRECT NUMBER OF STORIES. | | | | | | 4) PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | | | | 5) SHEET F2.01: PROVIDE LOCKING KNOX CAPS ON FIRE | | | DEPARTMENT CONNECTION. | | | | | | 6) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | 7) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION | | | SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | | MAY BE GENERATED DURING PLAN RESUBMISSION. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-20 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-03 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2019-06-20 07:42:18 | REMOVED ZONING STOP AND CLOSED REVIEW CYCLE AS | | | APPLICANT WILL BE SUBMITTING A NEW PACKAGE WITH NEW | | | DESIGN PROFESSIONAL UNDER A NEW PERMIT NUMBER | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-06-03 |
Time |
05:58 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-05-29 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-30 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-03 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-27 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-05 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-02-07 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-01-18 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-18 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-23 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-11 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-07 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2019-06-11 16:48:57 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-02 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2019-05-08 09:49:05 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2019-04-23 07:20:08 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-27 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-27 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2019-03-27 12:08:32 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2019-02-06 11:11:17 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-17 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-07 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2019-06-17 07:51:46 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 5TH REVIEW BY THIS PLANS EXAMINER. | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. (ENERGY SUBMITTAL RECIEVED - (GLAZING U-FACTORS | | | SHALL BE VERIFIED BY FIELD INSPECTOR) (EQUIPMENT SIZING | | | TO BE VERIFIED UPON RECEIPT OF EQUIPMENT | | | SPECIFICATIONS) | | | | | | 2. PLAN PAGE A0.1 STATE INSULATION SHALL BE 2 LAYERS OF | | | BATT. ENERGY SUBMITTAL STATES INSULATION SHALL BE BLOWN | | | IN. PLEASE CLARIFY. NOT CORRECTED - 4TH REQUEST | | | | | | 3. PROVIDE MECHANICAL PLAN. (NOT PROVIDED) DEMONSTRATE | | | HOW SPACE SHALL BE CONDITIONED. PROVIDE MECHANICAL | | | EQUIPMENT SPECIFICATIONS AND SIZING. - 4TH REQUEST | | | FBC E R403.7.1EQUIPMENT SIZING. | | | FBC RESIDENTIAL, CHAPTER 3 BUILDING PLANNING, SECTION | | | R303.10 REQUIRED HEATING. | | | RE403.7HEATING AND COOLING EQUIPMENT (MANDATORY). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-02 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2019-05-08 10:11:31 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW BY THIS PLANS EXAMINER. | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. (ENERGY SUBMITTAL RECIEVED - (GLAZING U-FACTORS | | | SHALL BE VERIFIED BY FIELD INSPECTOR) (EQUIPMENT SIZING | | | TO BE VERIFIED UPON RECEIPT OF EQUIPMENT | | | SPECIFICATIONS) | | | | | | 2. PLAN PAGE A0.1 STATE INSULATION SHALL BE 2 LAYERS OF | | | BATT. ENERGY SUBMITTAL STATES INSULATION SHALL BE BLOWN | | | IN. PLEASE CLARIFY. NOT CORRECTED - 3RD REQUEST | | | | | | 3. PROVIDE MECHANICAL PLAN. (NOT PROVIDED) DEMONSTRATE | | | HOW SPACE SHALL BE CONDITIONED. PROVIDE MECHANICAL | | | EQUIPMENT SPECIFICATIONS AND SIZING. | | | FBC E R403.7.1EQUIPMENT SIZING. | | | FBC RESIDENTIAL, CHAPTER 3 BUILDING PLANNING, SECTION | | | R303.10 REQUIRED HEATING. | | | RE403.7HEATING AND COOLING EQUIPMENT (MANDATORY). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-23 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2019-04-23 11:17:25 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW BY THIS PLANS EXAMINER. | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. (ENERGY SUBMITTAL CANNOT BE REVIEWED AT THIS TIME. | | | SUBMIT MECHABICAL SYSTEM TO BE INSTALLED TO PROVIDE | | | HEATING AND COOLING WITH EQUIPMENT SIZING CALCULATIONS. | | | U-VALUES OF FENESTRATION CANNOT BE DETERMINED AT THIS | | | TIME DUE TO NO WINDOW PRODUCT APPROVALS | | | SUBMITTED FOR REVIEW. | | | R405.4.3ADDITIONAL DOCUMENTATION. | | | THE CODE OFFICIAL SHALL BE PERMITTED TO REQUIRE THE | | | FOLLOWING DOCUMENTS: | | | 1. 1.VERIFICATION THAT AN EPL DISPLAY CARD SIGNED BY | | | THE BUILDER PROVIDING THE BUILDING COMPONENT | | | CHARACTERISTICS OF THE PROPOSED DESIGN WILL BE PROVIDED | | | TO THE PURCHASER OF THE HOME AT TIME OF TITLE TRANSFER. | | | 2. 2.DOCUMENTATION OF THE COMPONENT EFFICIENCIES USED | | | IN THE SOFTWARE CALCULATIONS FOR THE PROPOSED DESIGN.) | | | | | | 2. PLAN PAGE A0.1 STATE INSULATION SHALL BE 2 LAYERS OF | | | BATT. ENERGY SUBMITTAL STATES INSULATION SHALL BE BLOWN | | | IN. PLEASE CLARIFY. | | | | | | 3. PROVIDE MECHANICAL PLAN. ENERGY SUBMITTAL AND MANUAL | | | J SHOULD BE RE-EVALUATED AT TIME OF MECHANICAL PLAN | | | SUBMITTAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-04-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-04-06 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-04-06 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2019-04-06 07:46:17 | MECHANICAL PLAN REVIEW FAIL 3RD TIME NEED MECHANICAL | | | PLAN | | | | | | | | | CHRIS MONTELLO | | | 805-6733 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-03-16 |
Time |
05:47 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-03-16 |
Time |
05:39 |
Sent To |
|
|
| Notes |
| 2019-03-16 05:42:33 | MECHANICAL PLAN REVIEW FAIL | | | | | | NEED MECHANICAL PLANS | | | NEED MANUAL J | | | NEED ENERGY CALC | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-02-05 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-02-05 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2019-02-05 14:46:05 | NEED MECHANICAL PLANS | | | NEED MANUAL J | | | NEED ENERGY CALC | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-12 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-12 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2019-06-12 12:35:38 | PLUMBING 6TH REVIEW**DENIED** | | | | | | | | | NOTE***PER FL ST 553.80 (B)2B WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW.*** | | | | | | | | | PREVIOUS COMMENTS NOT ADDRESSED: | | | | | | 2) SHOW ACCESS TO THE WASHING MACHINE VALVES LOCATED | | | BEHIND THE MACHINE.FBC-RES P2903.9.3 PLACE NOTE ON PLAN | | | | | | 3) PROVIDE MANUFACTURE INSTALLATION MANUAL FOR THE | | | WATER HEATERS BEING USED. PLACE NOT ON PLAN WATER | | | HEATER SHALL COMPLY WITH FBC RES P2801.2, P2801.6, | | | P2801.6.2, P2804.6.1 DETAIL SHOWN ON PLAN DOES NOT | | | COMPLY WITH CODE PLEASE CORRECT OR REMOVE FROM PLAN. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4) SHOW HAMMER ARRESTOR BEING USED AT ALL QUICK CLOSING | | | VALVES. FBC-RES P2903.5 | | | REQUIRED ON HOT PIPING FOR DISHWASHER AND CLOTHES | | | WASHING MACHINE SHOW ON WATER ISOMETRIC. ARRESTORS NOT | | | SHOWN ON HOT PIPING PLEASE SHOW ARRESTOR ON HOT AND | | | COLD PIPING FOR DISHWASHER AND CLOTHES WASHING MACHINE. | | | PER FBC RES P2903.5 | | | | | | 5.) THE 2" WATER SERVICE REQUIRES A RPZ BACKFLOW DEVISE | | | WITH A SEPARATE PERMIT. PER WPB UTILITIES DEPARTMENT. | | | ON THE PLUMBING SITE LATOUT SHEET IT SHOWS A 2" WATER | | | SERVICE PLACE NOTE ON THE PLAN RPZ BACKFLOW REQUIRED | | | WITH SEPARATE PERMIT. PLACE NOTE ON PLAN RPZ SHALL BE | | | INSTALLED NEXT TO METER AND SHALL HAVE SEPARATE PERMIT. | | | | | | NEW COMMENTS; | | | | | | 1. THE VENTS FOR THE TOILETS AND THE TUBS ARE SHOWN AS | | | HORIZONTAL DRY VENT WHICH ARE NOT ALLOWED PER FBC RES | | | P3104.3, P3104.4 THE CORRECT WAY OF VENTING THE | | | BATHROOM GROUP IS TO CONNECT THE BRANCH DRAIN OF THE | | | LAVATORY TO THE BUILDING DRAIN BETWEEN THE TOILET AND | | | TUB THE VENT ON THE LAVATORY WILL VENT THE BATHROOM | | | GROUP MAKING IT A HORIZONTAL WET VENT SYSTEM. PER FBC | | | RES P3108.4 | | | | | | 2. FIXTURES CAN NOT BE DOUBLE TRAPPED THE PLAN SHOWS | | | THE LAVATORY AND TUB CONNECTING TO THE FLOOR DRAIN | | | TRAPS TH IS NOT ALLOWED THE BRANCH DRAINS FROM THE | | | LAVATORY AND TUB SHALL BE CONNECTED SEPARATELY TO THE | | | BUILDING DRAIN. PER FBC RES P3201.6 | | | | | | 3. THE KITCHEN DRAIN SHALL NOT CONNECT TO THE BATHROOM | | | GROUP IT SHALL CONNECT TO THE BUILDING DRAIN DOWN STEAM | | | OF THE BATHROOM GROUP. PER FBC RES FBC RES P3108.4 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-02 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-01 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2019-05-02 10:58:25 | PLUMBING 5TH REVIEW**DENIED** | | | | | | | | | NOTE***PER FL ST 553.80 (B)2B WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW.*** | | | | | | | | | PREVIOUS COMMENTS NOT ADDRESSED: | | | | | | 1) WASHING MACHINES SHALL NOT DISCHARGE INTO THE | | | HORIZONTAL WET VET OF THE BATHROOM GROUP FIXTURE'S. FBC | | | RES P3108.1 | | | | | | 2) SHOW ACCESS TO THE WASHING MACHINE VALVES LOCATED | | | BEHIND THE MACHINE.FBC-P 604.10.3 | | | | | | 3) PROVIDE INSTALLATION MANUAL FOR THE WATER HEATERS | | | BEING USED. FBC 107.1 | | | | | | 4) SHOW HAMMER ARRESTOR BEING USED AT ALL QUICK CLOSING | | | VALVES. FBC-RES P2903.5 | | | REQUIRED ON HOT PIPING FOR DISHWASHER AND CLOTHES | | | WASHING MACHINE SHOW ON WATER ISOMETRIC. | | | | | | 5.) THE 2" WATER SERVICE REQUIRES A RPZ BACKFLOW DEVISE | | | WITH A SEPARATE PERMIT. PER WPB UTILITIES DEPARTMENT. | | | ON THE PLUMBING SITE LATOUT SHEET IT SHOWS A 2" WATER | | | SERVICE PLACE NOTE ON THE PLAN RPZ BACKFLOW REQUIRED | | | WITH SEPARATE PERMIT | | | | | | 6). THE WASHING MACHINES REQUIRE HOT WATER. PER FBC PL | | | 607.1 | | | | | | NEW COMMENTS; | | | | | | 1) FIXTURES ARE NOT VENTED EACH FIXTURE SHALL BE VENTED | | | OR CONNECTED TO A VENTED LINE THE KITCHEN AND WASHING | | | MACHINE SHALL BE VENTED SEPARATELY THE CANNOT CONNECT | | | TO THE BATHROOM GROUP. PER FBC RES P3101.2.1 | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-10 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-10 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2019-04-10 16:15:12 | PLUMBING 3RD REVIEW**DENIED** | | | | | | | | | NOTE***PER FL ST 553.80 (B)2B WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW.*** | | | | | | | | | PREVIOUS CMMENTS NOT ADDRESSED: | | | | | | 1) DIGITAL PLANS SHALL COMPLY WITH 61G15-23.003 AND BE | | | ELECTRONICALLY SIGNED ON ELECTRONICALLY TRANSMITTED | | | PLANS. SOME PLANS ARE NOT SIGNED AT ALL. | | | | | | 2) EVERY TOILET AND TUB ARE DRY VENTED. DRY VENTING OF | | | FIXTURES ARE NOT PERMITTED AND MUST COMPLY WITH FBC-P | | | 912.2, 912.2.1, 912.2.2. | | | | | | 3) WASHING MACHINES SHALL NOT DISCHARGE INTO THE | | | HORIZONTAL WET VET OF THE BATHROOM GROUP FIXTURE'S. | | | FBC-P 912.1 | | | | | | 4) FITTING ON FLAT DRAWING APPEAR TO BE SANITARY TEE'S | | | WHICH ARE NOT PERMITTED FOR USE ON THERE BACK OR SIDE | | | FOR DRAINAGE. FBC-P 706.3 | | | | | | 5) THE TERM GULLY TRAP IS NOT DEFINED IN THE FBC. | | | PLEASE CLARIFY. FBC 107.1 | | | | | | 6) MISSING P-TRAPS ON FLAT DRAWING. EACH FIXTURE HAS BE | | | TRAPPED AND VENTED. FBC-P 1002.1 | | | | | | 7) SHOW ACCESS TO THE WASHING MACHINE VALVES LOCATED | | | BEHIND THE MACHINE.FBC-P 604.10.3 | | | | | | 8)PROVIDE A COMPLETE SANITARY ISOMETRIC. FBC-P 107.3.5 | | | | | | 9) PROVIDE INSTALLATION MANUAL FOR THE WATER HEATERS | | | BEING USED. FBC 107.1 | | | | | | 10) HOT WATER SHALL BE ON THE LEFT SIDE OF ALL | | | FIXTURES. FBC-P 607.4 | | | | | | 11) SHT.1007 LIST WATER PIPING AS BOT POLYPROPYLENE AND | | | UPVC. PLEASE CLEARIFY AS UPVC IS NOT AN APPROVED PIPING | | | SYSTEM PER FBC-P 605.4 | | | | | | 12) SHOW HAMMER ARRESTOR BEING USED AT ALL QUICK | | | CLOSING VALVES. FBC-P 604.9 | | | | | | 13) WHY IS THERE AN AIR ADMITTANCE VALVE LOCATED ON THE | | | WATER RISER DIAGRAM ON SHT. WS106? PLEASE CLEARIFY IT | | | USE. FBC-P 107.1 | | | | | | | | | NEW COMMENTS : | | | | | | 1. THE 2" WATER SERVICE REQUIRES A RPZ BACKFLOW DEVISE | | | WITH A SEPERATE PERMIT. PER WPB UTILITIES DEPARMENT | | | 2. THE WASHING MACINES REQUIRE HOT WATER. PER FBC RES | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-19 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-19 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2019-03-19 16:02:11 | PLUMBING 3RD REVIEW**DENIED** | | | | | | | | | NOTE***PER FL ST 553.80 (B)2B WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW.*** | | | | | | | | | 1) DIGITAL PLANS SHALL COMPLY WITH 61G15-23.003 AND BE | | | ELECTRONICALLY SIGNED ON ELECTRONICALLY TRANSMITTED | | | PLANS. SOME PLANS ARE NOT SIGNED AT ALL. | | | | | | 2) EVERY TOILET AND TUB ARE DRY VENTED. DRY VENTING OF | | | FIXTURES ARE NOT PERMITTED AND MUST COMPLY WITH FBC-P | | | 912.2, 912.2.1, 912.2.2. | | | | | | 3) WASHING MACHINES SHALL NOT DISCHARGE INTO THE | | | HORIZONTAL WET VET OF THE BATHROOM GROUP FIXTURE'S. | | | FBC-P 912.1 | | | | | | 4) FITTING ON FLAT DRAWING APPEAR TO BE SANITARY TEE'S | | | WHICH ARE NOT PERMITTED FOR USE ON THERE BACK OR SIDE | | | FOR DRAINAGE. FBC-P 706.3 | | | | | | 5) THE TERM GULLY TRAP IS NOT DEFINED IN THE FBC. | | | PLEASE CLARIFY. FBC 107.1 | | | | | | 6) MISSING P-TRAPS ON FLAT DRAWING. EACH FIXTURE HAS BE | | | TRAPPED AND VENTED. FBC-P 1002.1 | | | | | | 7) SHOW ACCESS TO THE WASHING MACHINE VALVES LOCATED | | | BEHIND THE MACHINE.FBC-P 604.10.3 | | | | | | 8)PROVIDE A COMPLETE SANITARY ISOMETRIC. FBC-P 107.3.5 | | | | | | 9) PROVIDE INSTALLATION MANUAL FOR THE WATER HEATERS | | | BEING USED. FBC 107.1 | | | | | | 10) HOT WATER SHALL BE ON THE LEFT SIDE OF ALL | | | FIXTURES. FBC-P 607.4 | | | | | | 11) SHT.1007 LIST WATER PIPING AS BOT POLYPROPYLENE AND | | | UPVC. PLEASE CLEARIFY AS UPVC IS NOT AN APPROVED PIPING | | | SYSTEM PER FBC-P 605.4 | | | | | | 12) SHOW HAMMER ARRESTOR BEING USED AT ALL QUICK | | | CLOSING VALVES. FBC-P 604.9 | | | | | | 13) WHY IS THERE AN AIR ADMITTANCE VALVE LOCATED ON THE | | | WATER RISER DIAGRAM ON SHT. WS106? PLEASE CLEARIFY IT | | | USE. FBC-P 107.1 | | | | | | TIM HUNT | | | PLUMBING INSPECTOR/PLUMBING PLAN EXAMINER | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-06 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2019-02-06 11:08:23 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | 1. PROVIDE PLUMBING PLAN. | | | 2. PROVIDE PLUMBING RISER DIAGRAHM. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-09-21 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-09-17 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2018-09-20 06:40:45 | 1) COVER SHEET - DEFINE THE OCCUPANCY OF THE STRUCTURE | | | IN ACCORDANCE WITH CHAPTER 3 OF THE 2017 | | | FBC-BUILDING.THE PLAN NOTES THE OCCUPANCY AS "POR" | | | WHICH IS NOT DEFINE IN THE FBC. CLARIFY. | | | 2) COVER SHEET - A NOTE ON THE LEFT SIDE OF THE COVER | | | SHEET REFERS TO THE 2010 FLORIDA BUILDING CODE. REMOVE | | | THIS NOTE. THE CODE IN EFFECT IS THE 2017 FBC. | | | 3) SHT.A1.01 - THE BREAK ROOM SINKS AND COUNTERTOPS | | | SHALL COMPLY WITH THE 2017 FBC-ACCESSIBILITY SECS. | | | 212.3, 606.1 THROUGH 606.5. SHOW THE REQUIRED CLEAR | | | FLOOR SPACE FOR THE BREAK ROOM SINKS ON THE PLANS. | | | 4) INDICATE THE OCCUPANT LOAD OF EACH COMMERCIAL SPACE | | | ON THE FIRST FLOOR IN ACCORDANCE WITH THE 2017 FBC | | | TABLE 1004.1.2. | | | 5) THE DOORS IN THE HANDICAP ACCESSIBLE TOILET ROOMS ON | | | THE FIRST FLOOR CANNOT SWING INTO THE REQUIRED CLEAR | | | FLOOR SPACE FOR THE LAVATORY PER THE 2017 FBC-ACCESS. | | | SEC.603.2.3. | | | 6) THE CONFIGURATION OF THE FIRST FLOOR PLAN ON SHT. | | | A1.01 DOES NOT CORRELATE WITH SHT. P1.01. THIS ALSO | | | OCCURS ON THE ELECTRICAL SHEET E1.02, AND THE | | | MECHANICAL SHEET M0.01. | | | 7) THE WATER SUPPLY SHUTOFF VALVES FOR THE STACKED | | | WASHER/DRYER UNITS THAT ARE LOCATED BEHIND THE UNITS | | | SHALL BE PROVIDED WITH ACCESS OR THE VALVES SHALL BE | | | RELOCATED TO PROVIDE ACCESS PER THE 2017 FBC-PLUMBING | | | SEC.606.3. | | | 8) SHT. A1.02. - SUBMIT STORM DRAIN PIPING CALCULATIONS | | | IN ACCORDANCE WITH THE 2017 FBC-PLUMBING SECS. L106.2, | | | 1106.3, 1106.4. | | | 9) SECONDARY ( EMERGENCY) ROOF DRAINS OR SCUPPERS SHALL | | | BE PROVIDED FOR THE ROOF PER 2017 FBC-PLUMBING | | | SEC.1108.1. SECONDARY ROOF DRAIN SYSTEMS SHALL HAVE THE | | | END POINT OF DISCHARGE SEPARATE FROM THE PRIMARY | | | SYSTEM. 2017 FBC-PLUMBING SEC. 1108.2. | | | 10) SHOW THE OCCUPANT LOAD FOR THE ROOF DECK / | | | RECREATIONAL ROOM. FBC 107.2.1. | | | 11) TEMPERED WATER IS REQUIRED TO ALL THE TOILET ROOM | | | LAVATORIES TO BE USED BY THE PUBLIC, CUSTOMERS, PATRONS | | | AND GUESTS PER THE 2017 FBC-PLUMBING SEC.416.5. | | | TEMPERED WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3. | | | 12) HOT WATER SHALL BE SUPPLIED TO ALL BREAKROOM SINKS | | | ON THE FIRST FLOOR. 2017 FBC-PLUMBING SEC.607.1. | | | 13) THE HOT WATER RECIRCULATION LINE SHALL BE INSULATED | | | IN ITS ENTIRETY PER THE 2017 FBC-PLUMBING SEC. 607.5 & | | | 2017 FBC-ENERGY SEC.R403.5.3.MINIMUM WALL THICKNESS | | | SHALL BE ONE INCH. | | | 14) THE FIRST FLOOR PLAN ON SHT. P2.01 DOES NOT | | | CORRELATE WITH THE FIRST FLOOR PLAN ON SHT. A1.01. | | | CLARIFY. | | | 15) THE FIRST FLOOR WATER RISER ON P3.01 DOES NOT | | | CORRELATE WITH THE FIRST FLOOR PLAN ON SHT. A1.01 FOR | | | THE TYPE OF PLUMBING FIXTURES AND AMOUNT. CLARIFY. | | | 16) SHT. P3.02 - THE WASTE AND VENT RISER DIAGRAM FOR | | | THE FIRST FLOOR DOES NOT CORRELATE WITH THE THE FIRST | | | FLOOR PLAN ON SHT.A1.01 FOR THE TYPE OF PLUMBING | | | FIXTURES AND AMOUNT. CLARIFY. | | | 17.)THE BUILDING APPEARS TO BE OVER THREE STORIES, | | | THEREFORE AN ELEVATOR WILL BE REQUIRED PER FL. STATUTE | | | 399.305 (2). | | | 18) SUBMIT COMPLETE DETAILS FOR THE ACCESSIBLE TOILET | | | ROOMS ON THE FIRST FLOOR.COMPLY WITH 2017 | | | FBC-ACCESSIBILITY. DETAILS REQUIRED FOR GRAB BARS ( | | | HEIGHT, LOCATIONS, LENGTHS, ETC.), PLUMBING FIXTURE, | | | TOILET PAPER AND HAND TOWEL DISPENSERS, MIRRORS, ETC. | | | 2017 FBC 107.2.1. | | | 19) IF AN ELEVATOR IS INSTALLED IN THIS BUILDING THEN | | | ALL THE RESIDENTIAL UNITS SHALL COMPLY WITH ALL THE | | | REQUIREMENTS OF THE FEDERAL FAIR HOUSING ACT & | | | GUIDELINES. | | | 20) SUBMIT FIRESTOPPING DETAILS FOR THE HORIZONTAL AND | | | VERTICAL PIPE PENETRATIONS. SUBMIT MANUFACTURER'S | | | INFORMATION, LISTING, INSTALLATION DETAILS, ETC. FBC | | | 107.2.1. | | | 21) BACKFLOW PREVENTION DEVICES ARE REQUIRED ON THE | | | DOMESTIC WATER SERVICE AND THE FIRE SERVICE LINES. A | | | SEPARATE PERMIT IS REQUIRED FOR THE BACKFLOW DEVICES. A | | | FIRE PROTECTION CONTRACTOR LICENSED AS A CONTRACTOR I, | | | II OR V SHALL APPLY FOR THE PERMIT FOR THE FIRE | | | BACKFLOW AND A LICENSED PLUMBING CONTRACTOR SHALL APPLY | | | FOR DOMESTIC BACKFLOW. PLEASE CONTACT THE CITY OF WPB | | | UTILITIES DEPT. AT 561-822-2240 FOR THE TYPE OF DEVICE | | | REQUIRED AND LOCATION. | | | 22) THE FLOOR DRAINS ON THE FOURTH FLOOR ARE NOT | | | PROPERLY VENTED. 2017 FBC-PLUMBING SEC.901.2, 901.2.1. | | | 23) VENTS EXCEEDING 40 FEET IN DEVELOPED LENGTH SHALL | | | BE INCREASED BY ONE NOMINAL PIPE SIZE FOR THE ENTIRE | | | DEVELOPED LENGTH OF THE VENT PIPE. 2017 FBC-PLUMBING | | | SEC.906.2. | | | 24) SHT. P4.01 - VENT INCREASER DETAIL - NOTE #1 STATES | | | "VENT THROUGH ROOF TO BE 4 INCHES." THE SANITARY RISER | | | ON SHT. P3.02 SHOWS ALL 2 INCH VENTS. CLARIFY. | | | 25) SHT.P4.01 - SHOW THE SIZE OF THE EXPANSION TANK. | | | 26) THE MINIMUM SIZE OF THE PAN DRAIN FOR THE WATER | | | HEATER SHALL BE 3/4 INCH. 2017 FBC-PLUMBING SEC. | | | 504.7.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-11 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-07 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2019-04-23 11:10:27 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE APPROPRIATE WIND LOADS PER FBCR CHPT.3. | | | VERIFY THEIR COMPATIBILITY WITH THE LOAD TABLES OF THE | | | SUBMITTED PRODUCT APPROVAL. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | 2. DESIGNER SHALL SELECT APPROPRIATE FASTENER PATTERN | | | AND PANEL GAUGE PER PAGE 2 OF 4 OF THE SUBMITTED | | | PRODUCT APPROVAL. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-27 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-27 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2019-03-27 13:22:56 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | | COMPONENTS. (STANDING SEAM METAL ROOF) - NOT ADDRESSED | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 2. PER AISI STANDARD S100-2007-C THE FOLLOWING MAY | | | APPLY: - NOT ADDRESSED | | | D6.2.1A STRENGTH (RESISTANCE) OF STANDING SEAM ROOF | | | PANEL SYATEMS - IN ADDITION TO THE PROVISIONS IN | | | SECTION D6.2.1, FOR LOAD COMBINATIONS THAT INCLUDE WIND | | | UPLIFT, THE NOMINAL WIND LOAD SHALL BE PERMITTED TO BE | | | MULTIPLIED BY 0.67 PROVIDED THE TESTED SYSTEM AND WIND | | | LOAD EVALUATION SATIFIES THE FOLLOWING CONDITIONS: | | | A. THE ROOF SYSTEM IS TESTED IN ACCORDANCE WITH AISI | | | S906. | | | B. THE WIND LOAD IS CALCULATED USING ASCE/SEI 7 FOR | | | COMPONENTS AND CLADDING, METHOD 1 (SIMPLIFIED | | | PROCEDURE) OR METHOD 2 (ANALYTICAL PROCEDURE). | | | C. THE AREA OF THE ROOF BEING EVALUATED IS IN ZONE 2 | | | (EDGE ZONE) OR ZONE 3 (CORNER ZONE). | | | | | | PLEASE INDICATE ON THE PLAN IF THIS OPTION WILL BE | | | UTILIZED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2019-02-06 10:58:47 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | | COMPONENTS. (STANDING SEAM METAL ROOF) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 2. PER AISI STANDARD S100-2007-C THE FOLLOWING MAY | | | APPLY: | | | D6.2.1A STRENGTH (RESISTANCE) OF STANDING SEAM ROOF | | | PANEL SYATEMS - IN ADDITION TO THE PROVISIONS IN | | | SECTION D6.2.1, FOR LOAD COMBINATIONS THAT INCLUDE WIND | | | UPLIFT, THE NOMINAL WIND LOAD SHALL BE PERMITTED TO BE | | | MULTIPLIED BY 0.67 PROVIDED THE TESTED SYSTEM AND WIND | | | LOAD EVALUATION SATIFIES THE FOLLOWING CONDITIONS: | | | A. THE ROOF SYSTEM IS TESTED IN ACCORDANCE WITH AISI | | | S906. | | | B. THE WIND LOAD IS CALCULATED USING ASCE/SEI 7 FOR | | | COMPONENTS AND CLADDING, METHOD 1 (SIMPLIFIED | | | PROCEDURE) OR METHOD 2 (ANALYTICAL PROCEDURE). | | | C. THE AREA OF THE ROOF BEING EVALUATED IS IN ZONE 2 | | | (EDGE ZONE) OR ZONE 3 (CORNER ZONE). | | | | | | PLEASE INDICATE ON THE PLAN IF THIS OPTION WILL BE | | | UTILIZED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-11 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-07 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2019-06-11 16:51:06 | SIGNATURE AND SEAL ON PLAN PAGES 008 THRU 025 HAVE BEEN | | | VERIFIED. SIGNATURES AND SEALS ON SEVERAL SUBMITTAL | | | DOCUMENTS ARE INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | NOTE: THE DESIGN PROFESSIONALS HAVE 2 OPTIONS, EITHER | | | COMPLY WITH FLORIDA ADMINISTRATIVE CODE 61G15-23.005 | | | PROCEDURES FOR SIGNING AND SEALING ELECTRONICALLY | | | TRANSMITTED PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS OR SUBMIT ORIGINAL PAPER DOCUMENT SIGNED AND | | | SEALED. | | | | | | THERE WILL BE A PRINT HOLD PLACED ON THE PERMIT UNTIL | | | VERIFICATION OF DESIGN PROFESSIONALS SIGNATURES AND | | | SEALS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-02 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2019-05-08 10:00:16 | SIGNATURE AND SEAL ON PLAN PAGES 008 THRU 025 HAVE BEEN | | | VERIFIED. ALL OTHER SIGNATURES AND SEALS ON SUBMITTAL | | | DOCUMENTS ARE INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | NOTE: THE DESIGN PROFESSIONALS HAVE 2 OPTIONS, EITHER | | | COMPLY WITH FLORIDA ADMINISTRATIVE CODE 61G15-23.005 | | | PROCEDURES FOR SIGNING AND SEALING ELECTRONICALLY | | | TRANSMITTED PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS OR SUBMIT ORIGINAL PAPER DOCUMENT SIGNED AND | | | SEALED. | | | | | | THERE WILL BE A PRINT HOLD PLACED ON THE PERMIT UNTIL | | | VERIFICATION OF DESIGN PROFESSIONALS SIGNATURES AND | | | SEALS. | | | | | | | | 2019-05-06 08:46:07 | ELECTRICAL SHEETS NOT OK. ONLY ONE SHEET HAS THE | | | REQUIRED SIGNATURE. SIGNATURE STOP FAILS FOR | | | ELECTRICAL. WPB FBC 107.1 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2019-04-23 07:24:06 | SIGNATURE AND SEAL ON PLAN PAGES 008 THRU 025 HAVE BEEN | | | VERIFIED. ALL OTHER SIGNATURES AND SEALS ON SUBMITTAL | | | DOCUMENTS ARE INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | 2019-04-05 12:51:18 | SIGNATURE REVIEW STATUS FOR ELECTRICAL SHEETS: DENIED, | | | SEE COMMENTS BELOW. | | | | | | 1. EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE | | | PROPER THIRD PARTY VERIFICATION. PROVIDE CORRECTIONS. | | | IN LIEU OF DIGITAL SIGNATURES, YOU MAY ALSO SUPPLY | | | PAPER COPIES OF EACH SHEET WITH THE PROPER SIGNATURE | | | AND SEAL. WPB FBC 107.1; FS 471/481 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-27 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-27 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2019-03-27 13:25:13 | SIGNATURE AND SEAL OF DESIGN PROFESSIONAL HAS BEEN | | | VERIFIED ON PLAN PAGES 008 THRU 025. ADDITIONAL REVIEW | | | MAY BE REQUIRED UPON RE-SUBMITTAL. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-07 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-07 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2019-03-07 13:52:27 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | SIGNATURE REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE | | | PROPER THIRD PARTY VERIFICATION. PROVIDE CORRECTIONS. | | | IN LIEU OF DIGITAL SIGNATURES, YOU MAY ALSO SUPPLY | | | PAPER COPIES OF EACH SHEET WITH THE PROPER SIGNATURE | | | AND SEAL. WPB FBC 107.1; FS 471/481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-05 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-05 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2019-02-05 10:52:25 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | SIGNATURE REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE | | | PROPER THIRD PARTY VERIFICATION. PROVIDE CORRECTION FOR | | | COVER SHEET, STRUCTURAL SHEETS 1 - 17, AND SHEET A-1 | | | FOUNDATION PLAN. IN LIEU OF DIGITAL SIGNATURES, YOU MAY | | | ALSO SUPPLY PAPER COPIES OF EACH SHEET WITH THE PROPER | | | SIGNATURE AND SEAL. WPB FBC 107.1; FS 471/481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
6 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-11 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-07 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2019-06-11 16:47:40 | THIRD PARTY INSPECTOR REQUIRED FOR BOLT TENSIONING. | | | PROVIDE RESUME AND FLORIDA REGISTRATION OF 3RD PARTY | | | INSPECTOR. CT |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
5 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-02 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2019-05-08 09:50:54 | THIRD PARTY INSPECTOR REQUIRED FOR BOLT TENSIONING. | | | PROVIDE RESUME AND FLORIDA REGISTRATION OF 3RD PARTY | | | INSPECTOR. CT |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
4 |
Status |
N |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-23 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2019-04-23 07:25:15 | THIRD PARTY INSPECTOR REQUIRED FOR BOLT TENSIONING. CT |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
N |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-27 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-27 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2019-03-27 13:20:00 | THIRD PARTY INSPECTOR REQUIRED FOR BOLT TENSIONING. CT |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
N |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-06 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-14 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-14 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2018-06-14 16:07:29 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FLORIDA STATUTE 553.79(5) 2016, THIS IS A THRESHOLD | | | BUILDING. THE FOLLOWING IS REQUIRED PRIOR TO | | | COMMENCEMENT: | | | | | | 1. COMPLETE THE THRESHOLD / SPECIAL INSPECTOR AGREEMENT | | | OF UNDERSTANDING; THIS HAS BEEN SENT VIA EMAIL TO | | | APPLICANT. | | | | | | 2. PROVIDE RESUMES AND COPIES OF LICENSES FOR ALL | | | PROPOSED INSPECTORS. | | | | | | 3. ALL PLANS ARE TO INCLUDE THE THRESHOLD STATEMENT | | | REQUIRED BY FS553.79(7)(D). | | | | | | (D)ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED TO BE | | | SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT?S OR ENGINEER?S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRESAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS CHAPTER 553 AND CHAPTER 633. | | | | | | 4. THRESHOLD INSPECTION PLAN REQUIRED, FS553.79(5)A). | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2019-05-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-05-07 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-05-07 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2019-05-07 10:07:28 | 5/7/19- PASSED | | | 1. A SEPERATE LANDSCAPE PERMIT IS REQUIRED TO BE | | | SUBMITTED PRIOR TO THE ISSUANCE OF THIS PERMIT OR A | | | CONDITIONAL PERMIT FORM CAN BE ISSUED UPON APPROVAL. | | | 2. SEPERATE PERMITS ARE REQUIRED FOR THE DRIVEWAY, | | | PARKING SPACES AND ANY FENCING. | | | 3. THIS PROPERTY CAN NOT BE RUN AS A ROOMING HOUSE. | | | | | | ANGELLA VANN, AICP | | | 561-317-8177 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-04-10 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-04-10 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-04-19 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2019-04-10 17:01:04 | 4/10/19- PASSED | | | 1. A SEPERATE LANDSCAPE PERMIT IS REQUIRED TO BE | | | SUBMITTED PRIOR TO THE ISSUANCE OF THIS PERMIT OR A | | | CONDITIONAL PERMIT FORM CAN BE ISSUED UPON APPROVAL. | | | 2. SEPERATE PERMITS ARE REQUIRED FOR THE DRIVEWAY, | | | PARKING SPACES AND ANY FENCING. | | | 3. THIS PROPERTY CAN NOT BE RUN AS A ROOMING HOUSE. | | | | | | ANGELLA VANN, AICP | | | 561-317-8177 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-03-13 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-03-13 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2019-03-13 11:30:15 | 3/13/19- FAILED. | | | 1. REMOVE THE DOORS INTO THE BEDROOMS ON THE NORTH AND | | | SOUTH SIDES OF THE 1ST FLOOR. | | | 2. A SEPERATE LANDSCAPE PERMIT IS REQUIRED TO BE | | | SUBMITTED PRIOR TO THE ISSUANCE OF THIS PERMIT OR A | | | CONDITIONAL PERMIT FORM CAN BE ISSUED UPON APPROVAL. | | | 3. SEPERATE PERMITS ARE REQUIRED FOR THE DRIVEWAY, | | | PARKING SPACES AND ANY FENCING. | | | 4. THIS PROPERTY CAN NOT BE RUN AS A ROOMING HOUSE. | | | | | | ANGELLA VANN, AICP | | | 561-317-8177 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-02-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-02-07 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-02-07 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2019-02-07 11:36:19 | 2/7/19- FAILED. PLEASE PROVIDE A WRITTEN EXPLANATION AS | | | TO THE USE OF THE STRUCTURE. THE FLOOR PLANS INDICATE | | | THAT IT WILL NOT BE USED AS A SINGLE FAMILY HOME. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2018-06-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2018-06-21 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2018-06-26 15:50:02 | 6/26/18-FAILED SEE COMMENTS BELOW: | | | | | | 1. MAXIMUM BUILDING HEIGHT IS 30 FT. SECTION 94-75 | | | (A)(3) | | | 2. NO PARKING WAS PROVIDED ON THE SITE PLAN. 4 PARKING | | | SPACES ARE REQUIRED FOR A DUPLEX. | | | 3. ARE THERE INTERNAL STAIRS? | | | 4. WHAT IS THE SETBACKS OF THE EXTERNAL STAIRCASE? | | | 5. LANDSCAPING SHALL BE PROVIDED AS FOLLOWS: | | | 1 SHADE TREE FOREACH 1500 SQ. FT. OF OPEN SPACE | | | 1 FLOWERING TREE FOR EACH 6,000 SQ. FT OF OPEN SPACE | | | 1 SHURB FOR EACH 500 SQ. FT. OF OPEN SPACE | | | GRASS SHALL NOT EXCEED 60 PERCENT OF THE REQUIRED | | | LANDSCAPING. | | | 6. A DETAIL FLOOR PLAN SHALL BE PROVIDED SO STAFF CAN | | | UNDERSTAND HOW MANY UNITS ARE BEING PROPOSED. | | | 7. SEPERATE PERMITS ARE REQUIRED FOR LANDSCAPING, | | | PARKING AND CURB CUT. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] | | | | | | |
|
|
|