Plan Review Details - Permit 18060562
| Plan Review Stops For Permit 18060562 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-13 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-13 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2018-08-13 10:47:41 | EXEMPT FROM AIPP PER S.WELTER | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-06 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-06 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-11-26 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-11-26 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2018-11-26 10:10:01 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18060562 | | | ADD: 3501 N MILITARY TRAIL | | | CONT: RALPH DELLA-PIETRA INC. | | | TEL: 561-723-3116 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: MON. NOV. 26/2018 | | | | | | ACTION: BUILDING PROVISO | | | | | | 1) SHEET A1.01 SHOWS 2 BUILDINGS. PHASE 1 IS FOR THE | | | CONCESSION AND RESTROOM BUILDING ONLY. | | | PHASE 2 BUILDING (1,298 SQ. FT.) NEW SHOWN AS REVISION | | | # 3 IS TO BE UNDER A SEPARATE PERMIT, PLANS AND | | | ASSOCIATED FEES. | | | | | | 2) WELDED OR BOLTED CONNECTIONS | | | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION. | | | 2014 FBC-B 2204.1 WELDING | | | 2014 FBC-B 2204.2 BOLTING. | | | | | | 3) 107.3.4.2 DEFERRED SUBMITTALS. 2017 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & COILING DOORS | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, EFIS | | | SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS AND OR FANS | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717/ FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-11 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-11 |
Time |
19:17 |
Sent To |
|
|
| Notes |
| 2018-08-11 19:22:22 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. WELDED OR BOLTED CONNECTIONS | | | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS. | | | 2017 FBC-B 2204.1 WELDING | | | 2017 FBC B 2204.4.2 BOLTING. | | | | | | PLEASE ADVISE; WHO WILL BE PERFORMING THE INSPECTIONS | | | FOR WELDED/BOLTED CONNECTIONS? | | | | | | 2. SEE FIRE COMMENTS REGARDING FIRE SPRINKLERS AS THEY | | | ARE APPLICABLE FOR BUILDING REVIEW. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-06 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-06 |
Time |
15:31 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-26 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-26 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-26 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-26 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2018-07-26 17:13:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE NEC AND FBC SPECIFIED FOR DESIGN ON SHEET A0.01 | | | IS NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC | | | PREFACE (ALSO SEE CURRENT CODES ABOVE) | | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94 | | | 3. PROVIDE THE REQUIRED SERVICE AREA RECEPTACLE PER | | | CODE. NEC 210.64 | | | 4. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLE OUTLETS | | | IN KITCHEN/CONCESSION AREA. NEC 210.8 | | | 5. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 6. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 7. PROVIDE GRAPH/CALCULATION OF EXTERIOR LIGHTING POWER | | | ALLOWANCES PER THE FBC ENERGY CONSERVATION IN RELATION | | | TO THE CONNECTED EXTERIOR LIGHTING PROPOSED TO COMPLY | | | WITH CODE. FBC EC C405.5.1 | | | 8. PROVIDE BLOCK NOTE INDICATING COMPLIANCE: ?WITHIN 30 | | | DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD | | | DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDE TO | | | THE BUILDING OWNER, INCLUDING: 1. A SINGLE LINE DIAGRAM | | | OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND 2. | | | FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL | | | DISTRIBUTION.? FBC EC C405.6.4.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2019-05-20 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2019-05-20 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-05-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-05-08 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-05-07 06:43:06 | ENGINEERING REVIEW WILL BE DONE NEXT REVIEW CYCLE | | | (SPOKE W/RR; MG IS OUT OF OFFICE). SPOKE WITH | | | APPLICANT; HE INFORMED THAT HE IS AWARE OF THE | | | ENGINEERING REQUIREMENT / S.HILL | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-21 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2018-12-21 18:31:06 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-02 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-02 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2018-08-02 13:11:30 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-04-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-04-29 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2019-04-29 14:55:31 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET C 5 - CRUSHED CONCRETE IS NOTED FOR THE FIRE | | | DEPT. ACCESS LANE. THIS ROADWAY SHALL MEET DOT | | | STANDARDS FOR ROADS AS THIS ROAD WILL BE USED BY | | | EMERGENCY VEHICLES. | | | | | | 18.2.3.4.2 SURFACE. FIRE DEPARTMENT ACCESS ROADS SHALL | | | BE DESIGNED | | | AND MAINTAINED TO SUPPORT THE IMPOSED LOADS OF FIRE | | | APPARATUS AND | | | SHALL BE PROVIDED WITH AN ALL-WEATHER DRIVING SURFACE. | | | | | | PLEASE ENSURE COMPLIANCE WITH DOT STANDARDS FOR ROADS | | | FOR THE FD ACCESS LANE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-10-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-10-05 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2018-10-05 12:38:14 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | IN AN EFFORT TO MOVE THIS PROJECT FORWARD PLEASE | | | CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET A 0.01 WAS NOT CORRECTED WITH THE COORECT | | | EDITIONS OF THE CURRENT NFPA CODES. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2013 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2013 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2013 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2013 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION. | | | CLEAN AGENT SYSTEMS SHALL COMPLY WITH NFPA 2001, 2012 | | | EDITION. | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH | | | NFPA 110, 2013 EDITION. | | | COMMERCIAL COOKING SHALL COMPLY WITH NFPA 96, 2014 | | | EDITION. | | | | | | PLEASE ENSURE COMPLIANCE AND UPDATE YOUR REFERNECES FOR | | | FUTURE SUBMITTALS | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-06-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-06-19 |
Time |
12:57 |
Sent To |
ENG |
|
| Notes |
| 2018-06-20 09:26:55 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET A 0.01 - THERE ARE INCORRECT EDITIONS OF THE | | | FIRE CODE INDICATED. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2013 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2013 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2013 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2013 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION. | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH | | | NFPA 110, 2013 EDITION. | | | | | | PLEASE REVIEW, CORRECT AND ENSURE COMPLIANCE WITH | | | CURRENT EDITIONS. | | | | | | | | | | | | 2) SHEET 0.02 - NOTE # 7 INDICATES THAT FIRE SPRINKLER | | | WORK WILL BE UNDERSEPARATE SHOP DRAWINGS. | | | | | | PLEASE CONFRM THAT THIS BUILDING WILL HAVE FIRE | | | SPRINKLERS. | | | | | | PROPOSED FIRE SPRINKLER DETAILS SHALL BE SUBMITTED WITH | | | THIS MASTER PERMIT IN COMPLIANCE WITH F.A.C. 61G | | | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | | ENGINEERING | | | DOCUMENTS. | | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | | AND STANDARDS, WHERE AVAILABLE. | | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | | 4-2-2000, 6-26-01 | | | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | | SYSTEMS. | | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | | SOURCES. | | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | | APPLICABLE: | | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | | CONCLUSIONS. | | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA. | | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | | DEMANDING DESIGN AREA. | | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | | SERVICE. | | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | | WATER. | | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | | MEASURES. | | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | | APPROVAL AND DOCUMENTATION. | | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | | 4-2-2000, 6-26-01, 7-12-05 | | | | | | SHOP DRAWINGS CAN BE DEVELOPED AND SUBMITTED OFF THESE | | | REQUIRMENTS. | | | | | | IF FIRE SPRINKLERS ARE NOT PROPOSED THESE DOCUMENTS ARE | | | NOT REQUIRED AND PROVIDE AN APPICABLE NOTE OR ROMOVE # | | | 7 FROM THE PAGE. | | | | | | | | | | | | 3) SHEET P 0.1 - THE EQUIPMENT SCHEDULE INDICATES ITEMS | | | 002 & 002A AS "SEE SHOP DRAWINGS". THERE ARE NO SHOP | | | DRAWINGS. | | | | | | ALL COOKING EQUIPMENT SHALL COMPLY WITH NFPA 96 WITH | | | THE HOOD AND SUPPRESSION SYSTEMS SUBMITTED UNDER | | | SEPARATE SHOP DRAWINGS. | | | | | | PLEASE REVIEW AND PROVIDE AN APPLICABLOE NOTE OF | | | ACKNOWLEDGEMENT. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-30 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-30 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2019-04-30 10:24:30 | GAS: | | | | | | A SEPARATE PERMIT AND PLANS REQUIRED FOR THE KITCHEN | | | GAS EQUIPMENT AND METER CONNECTION. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-11 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-11 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2018-12-11 15:48:13 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PREVIOUS GAS COMMENTS: | | | | | | 1. NOT COMPLIED SHT. P5.1 UNDER THE GAS NOTES #5 IT IS | | | REFERENCING A 5LB TO 1/2LB REGULATOR AT EACH APPLIANCE | | | IS THIS A 5LB SYSTEM PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 SHT WAS CHANGED TO P6.1 NOTE #6 | | | | | | 2.NOT COMPLIED PLEASE INDICATE SYSTEM PRESSURE ON THE | | | RISER. PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 OR 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 3.NOT COMPLIED SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (GAS METER / MP REGULATOR / LP TANK) TO THE | | | MOST REMOTE OUTLET IN THE BUILDING AND / OR SYSTEM PER | | | THE 2017 FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 | | | FBC-RES. SEC. G 2413.4.1, G2413.4.2. SHOW METER ON | | | RISER RESPONSE LETTER STATED IT WAS SHOWN ON CIVIL I | | | COULD NOT FIND ON CIVIL. | | | | | | 4. COMPLIED | | | | | | 5. NOT COMPLIED SUBMIT MANUFACTURER?S SPECIFICATION | | | SHEETS / INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 6.NOT COMPLIED PER FBC FG TABLE 402.4(2) AT A MBTU LOAD | | | OF 480 AND A DISTANCE OF 30' THE FIRST SECTION OF PIPE | | | BETWEEN THE METER AND FRYER SHALL BE 11/4 THE TWO | | | SECTIONS OF PIPE BETWEEN THE FRYERS AND GRIDDLE SHALL | | | BE 1" PLEASE CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | 7.NOT COMPLIED SHOW THE SIZES OF THE BRANCH PIPING | | | CONNECTING EACH APPLIANCE. PER WPB AMEND TO FBC 107.2.1 | | | | | | 8. COMPLIED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-08-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-08 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-08 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2018-08-08 11:43:03 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: | | | | | | 1. SHT. P5.1 UNDER THE GAS NOTES #5 IT IS REFERENCING A | | | 5LB TO 1/2LB REGULATOR AT EACH APPLIANCE IS THIS A 5LB | | | SYSTEM PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. PLEASE INDICATE SYSTEM PRESSURE ON THE RISER. PLAN | | | PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 THRU 402.6 OR | | | 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 3. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 FBC-RES. | | | SEC. G 2413.4.1, G2413.4.2. | | | | | | 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | 5. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 6. PER FBC FG TABLE 402.4(2) AT A MBTU LOAD OF 480 AND | | | A DISTANCE OF 30' THE FIRST SECTION OF PIPE BETWEEN THE | | | METER AND FRYER SHALL BE 11/4 THE TWO SECTIONS OF PIPE | | | BETWEEN THE FRYERS AND GRIDDLE SHALL BE 1" PLEASE | | | CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. SHOW THE SIZES OF THE BRANCH PIPING CONNECTING EACH | | | APPLIANCE. PER WPB AMEND TO FBC 107.2.1 | | | | | | 8. SHOW AUTOMATIC EMERGENCY SHUTOFF VALVE ON THE RISER. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-06-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-06-06 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-06-05 |
Time |
18:53 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-05-22 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-08 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2019-05-09 11:42:23 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-07 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-10 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-16 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-01 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-11 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-13 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-06-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-06-06 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-06-06 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2019-06-06 18:57:15 | $265.21 PAID. MU-2019-016112. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-11 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-11 |
Time |
19:17 |
Sent To |
|
|
| Notes |
| 2018-08-11 19:17:30 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-02 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-02 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-06 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-06 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2018-11-06 10:03:49 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18060562 | | | 11/6/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) CORRECT THE ENERGYGAUGE COMPLIANCE FORM WHICH IS | | | SPECIFYING THE JURISDICTION AS ALACHUA COUNTY FL. ON | | | PAGE 2. | | | | | | 2) 2ND REQUEST FOR THE MANUFACTURER'S PRODUCT DATA | | | (CUT) SHEETS FOR THE GAS-FIRED COOKING APPLIANCES. | | | THESE SUBMITTAL DOCUMANTS CAN BE DEFERRED IF REQUESTED | | | BY THE DESIGN PROFESSIONAL, HOWEVER ENGINEER STAMPED | | | COPIES WILL HAVE TO BE SUBMITTED PRIOR TO INSPECTION TO | | | AVOID A FAILURE IN THE FIELD. | | | | | | 3) THE AIR BALANCE INDICATES ALL 2000 CFMS OF O/A FROM | | | RTU-1 IS DEDICATED TO THE RESTROOMS, HOWEVER THE | | | COMBUSTION AIR CALCULATION FOR THE KITCHEN INDICATES | | | THAT 750 CFMS OF O/A FROM THE UNIT WILL BE PROVIDED. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-12 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-12 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2018-07-12 16:39:10 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18060562 | | | 7/12/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEMS- SECTION C403.2.1 FBC-17 EC. | | | | | | 2) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN HOOD | | | AND FIRE SUPPRESSION SYSTEM, HOWEVER THE PLANS FOR THE | | | MAIN PERMIT SHALL PROVIDE THE FOLLOWING INFORMATION: | | | | | | A) A MEANS OF SUPPLYING MAKEUP AIR DURING THE OPERATION | | | OF THE HOOD EXHAUST SYSTEM- SECTION 508.1 FBC M. | | | CONCERNING THE SEQUENCE OF OPERATIONS NOTE ON SHEET | | | M2.1, THE WINDOWS CANNOT BE USED AS MAKEUP AIR OPENINGS | | | BECAUSE THEY ARE NOT CONSIDERED GRAVITY OPENINGS. | | | | | | B) EQUIPMENT SCHEDULES FOR THE HOOD, EXHAUST FAN, AND | | | MAKEUP AIR UNIT. | | | | | | C) LOCATIONS OF THE FANS AND REQUIRED CLEARANCE | | | DISTANCES- SECTIONS 401.4 AND 506.3.13 FBC M. | | | | | | D) AN AIR BALANCE SCHEDULE OR DIAGRAM INDICATING THE | | | DESIGN OUTDOOR AIR BALANCE. THE DESIGN OUTDOOR AIR | | | BALANCE SHALL INDICATE ALL EXHAUST AND REPLACEMENT AIR | | | FOR THE FACILITY, PLUS THE NET EXFILTRATION IF | | | APPLICABLE. THE TOTAL REPLACEMENT AIR AIRFLOW RATE | | | SHALL EQUAL THE TOTAL EXHAUST AIRFLOW RATE PLUS THE NET | | | EXFILTRATION- SECTION 508.1.1 | | | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL | | | GAS-FIRED COOKING APPLIANCES- SECTION 623.1 FBC FG. | | | | | | 4) INDICATE HOW COMBUSTION AIR WILL BE PROVIDED TO THE | | | COOKING APPLIANCES AND PROVIDE CALCULATIONS- SECTION | | | 304 FBC FG. PLEASE NOTE THAT THERE IS NO KITCHEN | | | EQUIPMENT SCHEDULE ON SHEET A1.11. | | | | | | 5) INDICATE HOW THE DRY STORAGE ROOM WILL BE VENTILATED | | | AND PROVIDE A CALCULATION- SECTION 401.2. | | | | | | 6) SHEET M2.1 & M6.1: A SPACE HEATING SYSTEM SHALL BE | | | PROVIDED TO THE KITCHEN IN COMPLIANCE WITH SECTION | | | 309.1 FBC M. THE AC EQUIPMENT SCHEDULE INDICATES NO | | | HEAT FOR THE AHU'S. | | | | | | 7) M2.1: CLARIFY HOW THE AC SYSTEMS WILL ONLY RUN AFTER | | | HOURS ONLY WHEN THE PLAN SHOWS THEY ARE BEING | | | CONTROLLED THERMOSTATICALLY. PLEASE SEE SECTION | | | C403.2.4- C403.2.4.2.3 FBC EC. | | | | | | 8) M6.1: THE GH-1 (COOK 16X16 GI) IS A GRAVITY | | | VENTILATOR, HOWEVER IT IS INCLUDED IN THE EXHAUST FAN | | | SCHEDULE WITH AN EXHAUST RATE OF 750 CFMS. | | | | | | 9) SUBMIT FL. PRODUCT APPROVALS OR MIAMI-DADE NOA'S FOR | | | THE AC STANDS, AND THE ROOF MOUNTED EXHAUST FANS. | | | PROVIDE SITE SPECIFIC ENGINEERING FOR UNIT ANCHORING | | | AND ATTACHMENTS TO THE ROOF STRUCTURE- SECTION 301.15 | | | FBC M. | | | | | | 10) PROVIDE CONDENSATE DISPOSAL PLANS FOR THE AIR | | | HANDLERS- SECTION 307.2 FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-30 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-30 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2019-04-30 10:02:54 | PLUMBING PROVISO: | | | | | | COMPLETE PRIOR TO ROUGH INSPECTION | | | | | | 1. SHOW SLOPE OF PIE ON STORM RISER ISOMETRIC. PER FBC | | | PL 1106.2 | | | | | | 2. SHT P2.2 PROVIDE HEADINGS ON ROOF SQFT CALCULATION | | | AND GPM TO COMPLY WITH CURRENT CODE. PER FBC PL 1106.2 | | | | | | | | | PLUMBING: | | | | | | A SEPARATE PERMIT AND PLANS REQUIRED FOR THE KITCHEN | | | FIXTURE CONNECTIONS TO GREASE LINE AND HOT AND COLD | | | WATER. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-11 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-11 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2018-12-11 13:16:06 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PREVIOUS PLUMBING COMMENTS: | | | | | | 1. COMPLIED | | | | | | 2. PARTIALLY COMPLIED THE FLOOR DRAINS AND THE MOP SINK | | | SHALL BE INCLUDED IN THE GREASE TRAP SIZING | | | CALCULATIONS. PER FBC PL 1003.3.1 FLOOR DRAIN NOT | | | INCLUDED | | | | | | 3. NOT COMPLIED SHT. P2.1, P3.1 THE FLOOR PLAN SHOWS A | | | SINK NEXT TO THE REACH IN FREEZER #007 IT DOES NOT SHOW | | | UP ON THE ISOMETRIC DRAWINGS THE SINK SHALL CONNECT TO | | | THE GREASE SYSTEM. PLEASE CLARIFY PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 4. NOT COMPLIED PLEASE PROVIDE MANUFACTURE | | | SPECIFICATIONS AND INSTALLATION GUIDE FOR THE GREASE | | | TRAP. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. NOT COMPLIED PLEASE EXPAND THE ISOMETRIC DRAWING | | | THEY ARE TO CONGESTED TO DETERMINE CODE COMPLIANCE. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 6. COMPLIED | | | | | | NEW COMMENTS: | | | | | | 1. SHOW SLOPE OF PIE ON STORM RISER ISOMETRIC. PER FBC | | | PL 1106.2 | | | | | | 2. SHT P2.2 PROVIDE HEADINGS ON ROOF SQFT CALCULATION | | | AND GPM TO COMPLY WITH CURRENT CODE. PER FBC PL 1106.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-08 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-07 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2018-08-08 11:20:28 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE MOPSINK SHALL DISCHARGE THROUGH THE GREASE TRAP. | | | PER FBC PL 1003.3.1 | | | | | | 2. THE FLOOR DRAINS AND THE MOP SINK SHALL BE INCLUDED | | | IN THE GREASE TRAP SIZING CALCULATIONS. PER FBC PL | | | 1003.3.1 | | | | | | 3. SHT. P2.1, P3.1 THE FLOOR PLAN SHOWS A SINK NEXT TO | | | THE REACH IN FREEZER #007 IT DOES NOT SHOW UP ON THE | | | ISOMETRIC DRAWINGS THE SINK SHALL CONNECT TO THE GREASE | | | SYSTEM. PLEASE CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS AND | | | INSTALLATION GUIDE FOR THE GREASE TRAP. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 5. PLEASE EXPAND THE ISOMETRIC DRAWING THEY ARE TO | | | CONGESTED TO DETERMINE CODE COMPLIANCE. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 6. PLEASE PROVIDE STORM DRAIN ISOMETRIC DRAWING | | | INCLUDING SQFT DRAINED. PER WPB AMEND TO FBC | | | 107.3.5.1.3(13) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-30 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-30 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2019-04-30 10:19:16 | GREASE INTERCEPTOR: NOT APPROVED UNDER THIS PERMIT. | | | | | | SEPARATE PERMIT AND PLANS WITH MANUFACTURE SIZING | | | CALCULATIONS REQUIRED FOR INSTILLATION OF GREASE | | | INTERCEPTOR. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-11 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-11 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2018-12-11 15:31:02 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. C.6 SHOWS A 750 GAL. CONCRETE GREASE | | | INTERCEPTOR SHT. P5.1 SHOWS A GB2 35-50 GAL. | | | INTERCEPTOR PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. THE SCHIER GB2 SHALL BE INSTALLED INDOORS ONLY. PER | | | MANUFACTURE SPECIFICATIONS PLEASE CLARIFY ON PLUMBING | | | FLOOR PLAN THE LOCATION. | | | | | | 3. SHT. P5.1 THE MANUFACTURE SPECIFICATIONS SHOWN ON | | | PLAN DO NOT MATCH SPECIFICATION FROM SCHIER FOR A GB2 | | | PLEASE CLARIFY. | | | | | | 4. PROVIDE SIZING CALCULATIONS FROM SCHIER TO INCLUDE | | | THE SINGLE COMPARTMENT SINK NEXT TO WALK IN FREEZER, | | | FLOOR DRAIN, MOP SINK AND THREE COMP SINK. THE MIN SIZE | | | OF THE GREASE INTERCEPTOR SHALL BE 750GAL OR A | | | HYDROMACHANICAL EQUIVALENT PER WPB UTILITIES DEPT YOU | | | CAN CONTACT JEFFERY ODOMS AT 822-2172 WITH QUESTIONS. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-05-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2019-05-21 |
Time |
14:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2019-04-25 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2019-04-25 13:44:33 | | | | - REPEAT ISSUE: PLEASE NOTE THAT A SEPARATE LANDSCAPING | | | PERMIT IS REQUIRED FOR THE LANDSCAPING ASSOCIATED WITH | | | THE CONCESSION BUILDING AND ANY OTHER AREAS AFFECTED BY | | | THE CONSTRUCTION RELATED TO THE SUBJECT BUILDING | | | PERMIT. AS STATED IN PREVIOUS REVIEWS, THE LANDSCAPING | | | PERMIT (AND ANY OTHER NEEDED PERMITS) HAVE TO BE | | | SUBMITTED PRIOR TO ZONING'S APPROVAL OF THE CONCESSION | | | STAND BUILDING PERMIT. WHILE THE LATEST RESPONSE BY THE | | | APPLICANT STATES "NOTED, THE CONTRACTOR SHALL ACQUIRE A | | | SEPARATE LANDSCAPE PERMIT AS REQUIRED", TO DATE NO | | | LANDSCAPING PERMIT HAS BEEN SUBMITTED, HENCE ZONING | | | CANNOT APPROVE THE CONCESSION STAND BUILDING PERMIT. | | | | | | - CITY STAFF HAD PREVIOUSLY COMMENTED THAT CONSTRUCTION | | | OF ANY SIDEWALK, DRIVEWAY, OR PAVED AREA WITHIN THE | | | SCOPE OF WORK WOULD REQUIRE A SEPARATE PAVING PERMIT. | | | SHEETS C.4 AND C.5 OF THE PAVING, GRADING, AND DRAINAGE | | | PLANS SUBMITTED WITH THIS APPLICATION SHOW AREAS | | | IDENTIFIED FOR "PROPOSED CONCRETE" AND "PROPOSED | | | SIDEWALK". AGAIN, THIS WORK REQUIRES SUBMITTAL OF A | | | SEPARATE PAVING PERMIT PRIOR TO ZONING'S APPROVAL OF | | | THE CONCESSION STAND BUILDING PERMIT. | | | | | | | | | ALL OF THE PERMITS REFERENCED ABOVE HAVE TO BE | | | SUBMITTED PRIOR TO ZONING'S APPROVAL OF THE CONCESSION | | | STAND BUILDING PERMIT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-01-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2019-01-15 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2019-01-15 15:42:39 | PLEASE NOTE THAT THESE ARE REPEAT COMMENTS FROM THE | | | REVIEW OF THE FIRST SUBMITTAL WHICH WERE NOT ADDRESSED | | | IN THIS SUBMITTAL: | | | | | | - THE EAST AND SOUTH FACADES OF THE EXTERIOR ELEVATION | | | PLANS FOR THE CONCESSION STAND BUILDING SHOW EITHER THE | | | OXBRIDGE ACADEMY NAME IN LARGE LETTERS OR THE SCHOOL'S | | | LOGO. PLEASE NOTE THAT PER THE CITY'S ZONING CODE THE | | | SCHOOL'S NAME AND THE LOGO WOULD BE CONSIDERED AS | | | SIGNS, WHICH WILL REQUIRE SUBMITTAL OF A SEPARATE SIGN | | | PERMIT APPLICATION. | | | | | | - PLEASE NOTE THAT A SEPARATE LANDSCAPING PERMIT IS | | | REQUIRED FOR THE LANDSCAPING ASSOCIATED WITH THE | | | CONCESSION BUILDING. | | | | | | - IT IS NOT CLEAR FROM THE DOCUMENTS SUBMITTED WITH THE | | | PERMIT APPLICATION WHETHER THE APPLICANT IS PROPOSING | | | AT THIS TIME TO CONSTRUCT THE STORAGE ROOM TO THE WEST | | | OF THE CONCESSION STAND/RESTROOM BUILDING, THE | | | SIDEWALKS CONNECTING THE DIFFERENT BUILDINGS, THE | | | BASEBALL FIELD, OR THE PARKING LOT. PLEASE NOTE THAT | | | CONSTRUCTION OF ANY OF THESE REQUIRES A SEPARATE | | | BUILDING PERMIT. | | | | | | - IF THE PROPOSED PARKING LOT IS NOT BEING CONSTRUCTED | | | AT THIS TIME, THEN A DEMOLITION PERMIT IS REQUIRED FOR | | | THE DEMOLITION WORK SHOW ON SHEET C.3 FOR THE DRIVEWAY | | | AREA TO ACCESS THE PARKING LOT. | | | | | | ALL OF THE PERMITS REFERENCED ABOVE HAVE TO BE | | | SUBMITTED PRIOR TO ZONING'S APPROVAL OF THE CONCESSION | | | STAND BUILDING PERMIT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
ahansen |
Date |
2018-06-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2018-06-26 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2018-06-26 16:23:43 | COMMENTS BY ALEX HANSEN: | | | - THE CONCESSION STAND/RESTROOM BUILDING SHOWN IN THE | | | FLOOR PLAN SHEETS INCLUDED IN THE BUILDING PERMIT | | | APPLICATION HAS A TOTAL SQUARE FOOTAGE OF 2,121. THIS | | | IS ALMOST 100 SQUARE FEET MORE THAN THE 2,027 SQUARE | | | FEET SHOWN FOR THIS BUILDING IN THE SITE PLAN APPROVED | | | ON MARCH 28, 2018. EITHER THE BUILDING DIMENSIONS IN | | | THE BUILDING PLAN DOCUMENTS NEED TO BE REVISED AND MADE | | | CONSISTENT WITH THOSE IN THE APPROVED SITE PLAN, OR THE | | | APPLICANT NEEDS TO SUBMIT A MAJOR PLANNED DEVELOPMENT | | | AMENDMENT APPLICATION TO REVISE THE DIMENSIONS OF THE | | | CONCESSION STAND/RESTROOM BUILDING DEPICTED IN THE SITE | | | PLAN. | | | | | | - THE EAST AND SOUTH FACADES OF THE EXTERIOR ELEVATION | | | PLANS FOR THE CONCESSION STAND BUILDING SHOW EITHER THE | | | OXBRIDGE ACADEMY NAME IN LARGE LETTERS OR THE SCHOOL?S | | | LOGO. PLEASE NOTE THAT, PER THE CITY?S ZONING CODE, THE | | | SCHOOL?S NAME AND THE LOGO WOULD BE CONSIDERED AS | | | SIGNS, WHICH WILL REQUIRE SUBMITTAL OF A SIGN PERMIT | | | APPLICATION. | | | | | | - PLEASE NOTE THAT A SEPARATE LANDSCAPE PERMIT IS | | | REQUIRED FOR THE LANDSCAPING ASSOCIATED WITH THE | | | CONCESSION BUILDING. | | | | | | - IT IS NOT CLEAR FROM THE DOCUMENTS SUBMITTED WITH THE | | | PERMIT APPLICATION WHETHER THE APPLICANT IS PROPOSING | | | AT THIS TIME TO CONSTRUCT THE STORAGE ROOM TO THE WEST | | | OF THE CONCESSION STAND/RESTROOM BUILDING, THE | | | SIDEWALKS CONNECTING THE DIFFERENT BUILDINGS, THE | | | BASEBALL FIELD OR THE PARKING LOT. PLEASE NOTE THAT | | | CONSTRUCTION OF ANY OF THESE REQUIRES A SEPARATE | | | BUILDING PERMIT. | | | | | | - IF THE PROPOSED PARKING LOT IS NOT BEING CONSTRUCTED | | | AT THIS TIME, THEN A DEMOLITION PERMIT IS REQUIRED FOR | | | THE DEMOLITION WORK SHOWN ON SHEET C.3 FOR THE DRIVEWAY | | | AREA TO ACCESS THE PARKING LOT. | | | |
|
|
|