Plan Review Details - Permit 18060522
Plan Review Stops For Permit 18060522
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-07-23 Cont ID  
Sent By rmcdouga Date 2018-07-23 Time 09:35 Rev Time 0.00
Received By rmcdouga Date 2018-07-23 Time 09:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-03 Cont ID  
Sent By rmcdouga Date 2018-07-03 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2018-07-03 Time 09:10 Sent To I
Notes
2018-07-03 09:10:20REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE A DETAIL OF THE POOL STAIRS SHOWING THAT
 THEY COMPLY WITH ANSI/APSP/ICC 5 SECTION 6.2 FOR TREAD
 DEPTH AND RISER HEIGHT.
  
 2) SHOW HOW THE POOL BARRIER REQUIREMENTS OF FBC-R
 4501.17 WILL BE COMPLIED WITH FOR THIS PROJECT. SPECIFY
 THE METHOD OR COMBINATION OF METHODS THAT WILL BE USED.
  
 3) FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, THE VALUATION FOR THIS PROJECT OF
 $14,000.00 APPEARS LOW BASED ON SIMILAR PROJECTS.
 SUBMIT A COPY OF THE SIGNED CONTRACT FO ALL OF THE POOL
 WORK.
  
 4) A POOL PLUMBING PERMIT APPLICATION IS REQUIRED TO BE
 SUBMITTED BEFORE THE POOL PERMIT CAN BE ISSUED. FBC
 107.2.1

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-07-20 Cont ID  
Sent By jleahy Date 2018-07-20 Time 10:37 Rev Time 0.00
Received By jleahy Date 2018-07-20 Time 10:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-06-28 Cont ID  
Sent By jleahy Date 2018-06-28 Time 09:10 Rev Time 0.00
Received By jleahy Date 2018-06-28 Time 09:10 Sent To B
Notes
2018-06-28 09:12:12FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED TO SUBMIT FIXTURE CUT SHEETS, AND COMPLETE SETS OF
 CUTSHEETS FOR PUMP.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-06-28 Cont ID  
Sent By tklarge Date 2018-06-28 Time 06:18 Rev Time 0.00
Received By tklarge Date 2018-06-28 Time 05:42 Sent To  
Notes
2018-06-28 06:18:32THERE IS NO GAS ASSOCIATED WITH THIS POOL.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-07-23 Cont ID  
Sent By rmcdouga Date 2018-07-23 Time 11:28 Rev Time 0.00
Received By rmcdouga Date 2018-07-11 Time 15:15 Sent To  
Notes
2018-07-12 15:15:25RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-03 Cont ID  
Sent By rmcdouga Date 2018-07-03 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2018-06-12 Time 13:02 Sent To  
Notes
2018-06-13 13:02:42ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-07-23 Cont ID  
Sent By rmcdouga Date 2018-07-23 Time 11:28 Rev Time 0.00
Received By rmcdouga Date 2018-07-23 Time 10:22 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-28 Cont ID  
Sent By tklarge Date 2018-06-28 Time 06:17 Rev Time 0.00
Received By tklarge Date 2018-06-28 Time 05:42 Sent To  
Notes
2018-06-28 06:17:541) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).
 2) FOUR SETS OF PLANS HAVE BEEN SUBMITTED BUT ONLY TWO
 SETS HAVE PUMP SPECS.CLARIFY.
 3) INDICATE ON THE PUMP CURVE WHICH CURVE KEY IS
 APPLICABLE TO THE SPECIFIC PUMP BEING INSTALLED ON THIS
 SYSTEM. THIS IS REQUIRED TO MATCH THE CALCULATED TDH TO
 THE MAXIMUM SYSTEM FLOW RATE OF THE SYSTEM ON THE PUMP
 CURVE.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-07-18 Cont ID  
Sent By mcruz Date 2018-07-18 Time 11:32 Rev Time 0.00
Received By mcruz Date 2018-07-18 Time 11:32 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-06-15 Cont ID  
Sent By mcruz Date 2018-06-15 Time 12:02 Rev Time 0.00
Received By mcruz Date 2018-06-15 Time 12:01 Sent To B
Notes
***NONE***