Plan Review Details - Permit 18060357
| Plan Review Stops For Permit 18060357 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-13 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-13 |
Time |
05:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-06-16 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-16 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2018-06-16 17:33:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. THE DOOR TO THE AREA BETWEEN ROOMS 111 AND 109 LACKS | | | THE 18" MANEUVERING CLEARANCE REQUIRED BY FBC A FIGURE | | | 404.2.4.1(A). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-21 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-21 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-06-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-06-29 |
Time |
12:55 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-13 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-02 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2018-07-03 14:46:26 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-07-02 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-08 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-09 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-09 |
Time |
11:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-12 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2018-06-12 11:52:25 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #18060357 | | | MASTER #17110531 | | | 6/12/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE FIFTH EDITION 2014 | | | FBC M- FLORIDA MECHANICAL CODE FIFTH EDITION 2014 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE FIFTH EDITION | | | 2014 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2014 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ENGINEER OF RECORD SHALL PROVIDE A RAISED OR INK | | | SEAL AND SIGNATURE ON THE PLANS. ELECTRONIC SEALS AND | | | SIGNATURES ARE FOR USE ON ELECTRONIC PLANS AND | | | DOCUMENTS, COPIED ELECTRONIC SEALS ARE NOT PERMITTED | | | PER SECTION 61G15-23.005 FAC. | | | | | | 2) SHOW THE LOCATIONS OF ACCESS PANELS FOR VAV'S 3-2, | | | 3-3, 3-5, & 3-6 IF THESE UNITS ARE ABOVE HARD CEILINGS- | | | SECTION 306.1 FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-14 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-14 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
|