Plan Review Details - Permit 18060304
| Plan Review Stops For Permit 18060304 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-07-13 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-06-16 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-06-16 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2018-06-16 17:12:25 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | | SPREADSHEET): | | | | | | HTTP://WPB.ORGTS/DEVELOPMENT-SERVICES/FORMS/BUILDING-PE | | | RMIT-FORMS?PAGE=2 | | | | | | 2. TABLES: FBC R 301.2(2)/FBC R 301.2(3), IN ADDITION | | | TO COMPLETING THE FORM LISTED ABOVE, THE MAXIMUM | | | POSITIVE AND NEGATIVE PRESSURES SHOWN IN THE SUBMITTAL | | | PACKAGE INCLUDING THE ENGINEERED SCHEDULES DO NOT MEET | | | THE CODE REQUIRED PRESSURES AS LISTED IN THE FBC | | | TABLES: R 301.2(2) AND R 301.2(3). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-15 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-06-15 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-06-15 |
Time |
05:54 |
Sent To |
B |
|
| Notes |
| 2018-06-15 06:27:27 | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-06-12 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-06-12 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2018-06-12 15:50:56 | 6/12/2018 - HPB APPROVAL FOR WHITE FRAME, BLACK SCREEN | | | ROLL DOWN HURRICANE SHUTTER (HPB CASE NO. 18-25) ON | | | FRONT ELEVATION OF PORCH. DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-07-13 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-07-10 |
Time |
09:52 |
Sent To |
I |
|
| Notes |
| 2018-07-12 09:52:30 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-06-16 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-06-16 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2018-06-08 12:49:08 | ROUTED TO HISTORIC INBOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |