| Plan Review Stops For Permit 18060285 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-09-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-20 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-20 |
Time |
15:32 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-13 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-13 |
Time |
12:26 |
Sent To |
M |
|
| Notes |
| 2018-08-13 12:26:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (BOTH | | | COPIES) IS REQUIRED TO BEAR THE NAME AND BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. THIS | | | PERSON MUST BE A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. | | | WPB FBC 107.1, 107.2; FS 471, 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-24 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-06-24 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-06-24 |
Time |
09:00 |
Sent To |
M |
|
| Notes |
| 2018-06-24 09:09:12 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ELECTRICAL PLAN SUBMITTED IS EXTREMELY VAGUE AND IS | | | INSUFFICIENT. PROVIDE ELECTRICAL PLAN FOR REVIEW, | | | SIGNED AND SEALED BY A LICENSED DESIGN PROFESSIONAL OR | | | THE ELECTRICAL CONTRACTOR QUALIFIER. IF THERE IS NOT | | | ANY ELECTRICAL WORK INCLUDED WITH THIS PERMIT, STATE | | | THAT ON PLAN. FS 471.003(2)(H); 471.025; WPB FBC | | | 107.2.1, 107.3.5 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
GJT |
Date |
2018-06-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
gtelfair |
Date |
2018-06-20 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2018-06-20 14:33:06 | PASSED WITH THE FOLLOWING PROVISO: | | | | | | 1. ENSURE THAT NOTIFICATION APPLIANCES ARE CREATING | | | 75DB AT THE PILLOW TOP OF EACH BEDROOM IN ACCORDANCE | | | WITH NFPA 72 ? 7.4.4.1 | | | | | | 2. ENSURE THAT ALL EXTERNAL DEVICES ARE EQUIPPED WITH | | | WEATHER PROOF ENCLOSURES. | | | | | | 3. TEST ALL EXISTING DEVICES TO ENSURE COMPATIBILITY | | | AND FUNCTIONALITY WITH NEW FIRE ALARM COMMUNICATOR. | | | | | | 4. ENSURE THAT ALL FIRE ALARM PULL STATIONS ARE | | | INSTALLED TO MEET NFPA 72 INCLUDING HEIGHT AND TRAVEL | | | DISTANCES. | | | | | | 5. PROVIDE RECORD OF COMPLETION AT TIME OF INSPECTION. | | | | | | 6. ANY DETECTION DEVICES EXPOSED TO THE ELEMENTS SHALL | | | BE HEAT DETECTION AS OPPOSE TO SMOKE DETECTION TO | | | ALLEVIATE FALSE ALARMS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-09-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-09-18 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2018-09-19 14:42:07 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-08-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-09 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-07 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2018-06-08 14:01:03 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-13 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-13 |
Time |
13:06 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-28 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-28 |
Time |
12:25 |
Sent To |
I |
|
| Notes |
| 2018-06-28 12:42:31 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18060285 | | | 6/28/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTAL PACKAGE INCLUDES SPECS FOR MANY | | | CONTROLS, ALARMS, NOTIFICATION AND DETECTION DEVICES. | | | PLEASE ADJUST THE $1800.00 VALUE ON THE APPLICATION TO | | | INCLUDE LABOR, MATERIALS, EQUIPMENT, AND DESIGN FEES | | | FOR THE ENTIRE SCOPE OF WORK INCLUDING INSTALLATION | | | COSTS, AND THE COSTS ASSOCIATED WITH THE SYSTEM | | | RECERTIFICATION- SECTION 109.3 WPB. | | | | | | 2) PROVIDE A SCOPE OF WORK OUTLINE FOR THE NFPA 72 | | | RECERTIFICATION OF THE FIRE ALARM SYSTEM, AND A SCOPE | | | OF WORK FOR ALL NEW OR REPLACEMENT CONTROLS, DEVICES | | | ETC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|