| Plan Review Stops For Permit 18060281 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-11 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-11 |
Time |
15:52 |
Sent To |
P |
|
| Notes |
| 2018-07-11 15:54:20 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-26 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-26 |
Time |
13:11 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-07-11 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-11 |
Time |
12:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-14 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-14 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-26 |
Time |
05:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-26 |
Time |
05:31 |
Sent To |
|
|
| Notes |
| 2018-06-26 05:39:21 | THERE IS NO GAS ASSOCIATED WITH THIS POOL. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-16 |
Time |
06:46 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-28 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2018-06-28 15:45:46 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-26 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-07 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2018-06-08 12:57:14 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-16 |
Time |
06:46 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-16 |
Time |
06:44 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-26 |
Time |
05:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-26 |
Time |
05:31 |
Sent To |
|
|
| Notes |
| 2018-06-26 05:35:24 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER). | | | 2) INDICATE ON THE POOL PUMP CURVE THE SPECIFIC CURVE | | | KEY THAT APPLIES TO THE PUMP BEING INSTALLED ON THIS | | | POOL. THIS IS NEEDED TO CHECK THE MAXIMUM SYSTEM FLOW | | | FROM THE TDH CALCULATIONS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-02 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-02 |
Time |
15:01 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-11 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-06-11 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-06-11 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
| 2018-06-11 14:32:13 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) PURSUANT TO SEC. 94-304(D)(2), SWIMMING POOLS SHALL | | | BE LOCATED AT LEAST 5 FEET FROM REAR LOT LINE. THE | | | SETBACK SHOWN IS 3.75'. | | | 2) PURSUANT TO 94-305(B)(4) - MECHANICAL EQUIMENT MAY | | | NOT PROJECT MORE THAN 4 FEET INTO A SETBACK. ENSURE | | | POOL EQUIPMENT IS AT LEAST 6' FROM SIDE PROPERTY LINE. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] | | | |
|
|