| Plan Review Stops For Permit 18060221 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-11-20 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-11-20 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2018-11-20 07:40:23 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED WITH PROVISO: | | | | | | PLEASE PROVIDE THE ROOFING PRODUCT APPROVAL AND | | | INDICATE WHICH ASSEMBLY IS PROPOSED. THE DESIGNER OF | | | RECORD NEEDS TO APPROVE THE CHOSEN SUBMITTAL. PLEASE | | | SUBMIT THE DESIGNER OF RECORD APPROVED SUBMITTAL PRIOR | | | TO INSPECTIONS. PV |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-14 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2018-07-14 10:09:14 | ***CORRECTIONS*** | | | PERMIT # 18060221 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 109] VALUE TOO LOW; PROJECT VALUE HAS BEEN | | | ADJUSTED PER ICC TABLES: | | | 448 SQ. FT. NEW UNDER AIR ADDITION X $130.95 | | | 88 SQ. FT. PORCH X $21 | | | | | | 2. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO | | | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. | | | CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION TO | | | SUPPORT. UPDATE R-VALUES TO COMPLY WITH METHOD USED. | | | | | | 3. [FBC R302.11]ADD FIREBLOCKING TO DETAIL ON TYPICAL | | | WALL SECTION. | | | | | | 4. [FBC R608.8]THE LINTEL SCHEDULE CALLS OUT TYPE "5" | | | FOR LINTEL TO BE 5'-2" TO GO IN A 5'-4 R.O. | | | YOU MAY NEED TO CHANGE TO TYPE "6" FOR LINTEL 5'-10" TO | | | PROVIDE 4" OF BEARING AS REQUIRED FOR MASONRY. | | | | | | 5. IF USING SERIES 4000 ALUM SLIDING DOOR AS PROVIDE | | | FULL N.O.A. NO.15-0818.07, AND PROVIDE PRODUCT APPROVAL | | | FOR HURRICANE PROTECTION. INDICATE IF NOT USING AND WE | | | WILL VOID SERIES 4000. | | | | | | 6. ARE EXISTING WINDOWS BEING REPLACED OR WERE THE | | | SIZES WRITTEN IN FOR REFERENCE? IF THEY ARE BEING | | | REPLACED PROVIDE PRESSURES AND PRODUCT APPRVAL FOR MULL | | | BAR AND UPDATED VALUE. | | | | | | 7. [FBC R802.11]PROVIDE DESIGN PRESSURE FOR CLADDING | | | AND COMPONANTS(ROOF AND WALLS). | | | | | | 8. [FBC 107, R301] PROVIDE AN INFILL DETAIL. | | | | | | 9. [FBC R FIGURE 301.2(7), ENHANCED NAIL NOTE, THE ROOF | | | DIAGRAM DOES NOT APPEAR TO BE CONSISTENT WITH FIGURE R | | | 301.2(7). IT APPEAR TO INCLUDE A RIDGE WITH ZONE 2; | | | ISN'T THE NEW FLAT ROOF AREA LOW SLOPE (MONOSLOPE)? NO | | | ZONE 3 SHOWN ON ONE SIDE. ISN'T A PARAPET ON ALL SIDES | | | REQUIRED TO ELIMINATE ZONE 3? REVISE, OR PROVIDE | | | RATIONALE, OR CONTACT ME TO DISCUSS. | | | | | | NOTE: | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-10-03 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-10-03 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-16 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-10-03 |
Time |
10:12 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-11-20 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-12 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-09-19 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-07-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-06 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2018-10-06 12:47:22 | PLAN STAMPED; $0 DUE | | | STAPLED TO APPLICATION | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-07-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-07-06 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-14 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2018-07-14 09:59:53 | IMPACT FEES OK; PLAN IS STAMPED AND $0 DUE | | | PRIOR TO ISSUANCE, VERIFY THAT THE STAMPED PLAN HAS NOT | | | BEEN REMOVED FROM THE PACKAGE | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-11-20 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-12 |
Time |
08:40 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-07-16 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-07-16 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2018-07-16 11:22:59 | PLAN DENIED | | | 1) REFER TO SECTION R 403.7.1 EQUIPMENT SIZING | | | 2017 FLORIDA ENERGY CODE | | | 2) REFER TO SECTION M 1401.3 EQUIPMENT AND | | | APPLIANCE SIZING 2017 RESIDENTIAL CODE | | | 3) SHOW THE LOCATION OF THE CONDENSATE LINE | | | ON THE PLAN. SECTION M1411.3 CONDENSATE | | | DISPOSAL. 2017 RESIDENTIAL CODE | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-07-06 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-07-06 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-10-06 |
Time |
12:53 |
Sent To |
M |
|
| Notes |
| 2018-10-06 12:54:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | | | | 1. A CERTAINTEED FLAT DECK NOA WAS PROVIDED, BUT | | | ASSEMBLY NOT SELECTED, SO THIS WAS NOT STAMPED. EITHER | | | INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED AND | | | PROVIDE RAS117 CALCULATIONS, IF APPLICABLE, OR REQUEST | | | THAT THIS BE DEFERRED. | | | | | | IF DEFERRED, THE FOLLOWING IS REQUIRED PRIOR TO ROOF | | | COMMENCEMENT: | | | | | | SUBMIT ROOF PERMIT APPLICATION WITH PRODUCT APPROVAL | | | INDICATE WHICH ASSEMBLY IS PROPOSED | | | DESIGNER OF RECORD TO REVIEW PRODUCT APPROVAL PRIOR TO | | | SUBMITTAL | | | PROVIDE RAS117 CALCULATIONS PREPARED BY A DESIGN | | | PROFESSIONAL IF REQUIRED | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-04 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-04 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-06-18 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-06-18 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-06-18 |
Time |
15:48 |
Sent To |
PC |
|
| Notes |
|
|