Plan Review Details - Permit 18060039
Plan Review Stops For Permit 18060039
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-12 Cont ID  
Sent By rmcdouga Date 2018-06-12 Time 09:35 Rev Time 0.00
Received By rmcdouga Date 2018-06-12 Time 07:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-07-09 Cont ID  
Sent By jpearson Date 2018-07-09 Time 12:45 Rev Time 0.00
Received By jpearson Date 2018-07-09 Time 12:45 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-06-18 Cont ID  
Sent By jpearson Date 2018-06-18 Time 17:14 Rev Time 0.00
Received By jpearson Date 2018-06-18 Time 17:14 Sent To I
Notes
2018-06-18 16:54:18CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE CHAPTER ONE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENT NOT ADDRESSED SATISFACTORILY. PREVIOUS
 COMMENTS THAT HAVE BEEN ADDRESSED SATISFACTORILY HAVE
 BEEN NOTED AS CORRECTED. ITEMS REMAINING HAVE FURTHER
 COMMENTS IN PARENTHESES. NEW COMMENTS FOLLOW THE
 PREVIOUS COMMENTS.
  
 1. LOCATION OF CU-2 IS NOT CLEAR. IS IT LOCATED ON
 ROOF, OR IN BASEMENT NEXT TO OTHER UNITS AS REVISION
 INDICATES? PROVIDE CORRECTION. WPB FBC 107.2.1
  
 NEW COMMENTS:
  
 2. LOAD CALCULATION PROVIDED IS NOT SUFFICIENT. IT
 SEEMS STRANGE THAT THE LOAD WOULD GO FROM THE 798 AMPS
 STATED ON ORIGINAL PLAN TO 590 AMPS ON THIS REVISION
 AFTER THE INSPECTOR NOTED THAT THERE IS ONLY A 600 AMP
 SERVICE THERE. PROVIDE A DETAILED LOAD CALCULATION FOR
 ALL LOADS. NEC 220; WPB FBC 107.2.1
 3. BASED ON DISCUSSION WITH INSPECTOR, IS SEEMS THERE
 IS A 600 AMP DISCONNECT FOR THIS SERVICE NOT SHOWN ON
 PLAN. PROVIDE ACCURATE RISER DIAGRAM SHOWING THE
 SERVICE LOCATION AND INCLUDE DESCRIPTION OF THE NUMBER
 OF MAINS FOR THE SERVICE. NEC 230.2, 230.71, 230.72;
 WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-06-12 Cont ID  
Sent By jpearson Date 2018-06-12 Time 11:59 Rev Time 0.00
Received By jpearson Date 2018-06-11 Time 17:09 Sent To I
Notes
2018-06-12 11:59:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE CHAPTER ONE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. LOCATION OF CU-2 IS NOT CLEAR. IS IT LOCATED ON
 ROOF, OR IN BASEMENT NEXT TO OTHER UNITS AS REVISION
 INDICATES? PROVIDE CORRECTION. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-06-06 Cont ID  
Sent By scaldero Date 2018-06-06 Time 09:45 Rev Time 0.00
Received By scaldero Date 2018-06-06 Time 09:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2018-07-09 Time   Rev Time 0.00
Received By rbrown Date 2018-07-06 Time 16:43 Sent To  
Notes
2018-07-06 16:44:16RESUB ROUTED TO JOHN PEARSON.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-06-18 Time   Rev Time 0.00
Received By lmarchan Date 2018-06-13 Time 11:48 Sent To  
Notes
2018-06-14 11:48:59RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2018-06-12 Time   Rev Time 0.00
Received By lmarchan Date 2018-06-01 Time 16:30 Sent To  
Notes
2018-06-04 16:30:25B33

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2018-07-09 Cont ID  
Sent By cpuell Date 2018-07-09 Time 14:15 Rev Time 0.00
Received By cpuell Date 2018-07-09 Time 14:15 Sent To  
Notes
2018-07-09 14:15:56CUSTOMER REMOVED THE MECHANICAL PAGES

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-06-12 Cont ID  
Sent By ccole Date 2018-06-12 Time 09:39 Rev Time 0.00
Received By ccole Date 2018-06-12 Time 07:47 Sent To  
Notes
2018-06-12 09:44:571ST REVIEW FBC-2014 MECHANICAL
 PERMIT #18060039
 MASTER #17010872
 6/12/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE FIFTH EDITION 2014
 FBC M- FLORIDA MECHANICAL CODE FIFTH EDITION 2014
 FBC EC- FLORIDA ENERGY CONSERVATION CODE FIFTH EDITION
 2014
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2014
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M0.1: THE OUTDOOR AIR CALCULATIONS INDICATE A
 NEW DOA-1 PRODUCING 170 CFMS OF O/A, HOWEVER THE DOA
 APPARENTLY HAS BEEN REPLACED WITH AHU-2 WHICH IS
 PRODUCING 300 CFMS OF O/A ACCORDING TO THE AIR BALANCE
 SCHEDULE- PLEASE CORRECT.
  
 2) M0.1: THE REVISED AC SCHEDULE INDICATES THE NEW
 AHU-2/CU-2 IS A 9.3 TON SPLIT SYSTEM WITH AN AIR
 HANDLER THAT IS PRODUCING ONLY 1200 CFMS OF SUPPLY AIR.
 A 9.3 TON SYSTEM WOULD TYPICALLY PRODUCE APPROXIMATELY
 4000 CFMS OF AIR IF THE AIR HANDLER WAS MATCHED
 PROPERLY WITH THE CONDENSER. PLEASE CLARIFY THE
 DISCREPANCIES HERE AND THE NEED FOR SUCH A LARGE SYSTEM
 WHEN THE
 CALCULATIONS ARE CALLING FOR SUCH A SMALL AMOUNT OF O/A
 AIR.
  
 3) M0.1 & M1.1: THE AIR BALANCE SCHEDULE INDICATES THE
 KITCHEN HOOD EXHAUST AT -300 CFMS, HOWEVER THE PLAN
 INDICATES -1500 CFMS- PLEASE CLARIFY.
  
 4) M1.1 & E1.1: CLARIFY THE LOCATION OF THE NEW AHU-2
 CONDENSERS. THEY ARE SHOWN AT THE SIDEWALK GRATE
 LOCATION ON THE MECHANICAL PLANS WHICH INDICATES THAT
 THEY MAY BE GOING UNDER THE SIDEWALK BY THE EXISTING
 CU-1. THERE IS ALSO AN ENLARGED DETAIL OF THE ROOF
 STANDS WHICH HAS A CLOUDED NOTE INDICATING " NEW
 CONDENSING UNIT FOR DOA"., HOWEVER NO UNITS ARE SHOWN
 IN THE
 CLOUD. THE ELECTRICAL PLAN HAS A SECTION CUT SHOWING
 THE CONDNENSERS OF THE EXISTING ROOF STAND SYSTEM.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-06-12 Cont ID  
Sent By gjohnson Date 2018-06-12 Time 11:47 Rev Time 0.00
Received By gjohnson Date 2018-06-12 Time 11:47 Sent To  
Notes
***NONE***