Plan Review Details - Permit 18051500
Plan Review Stops For Permit 18051500
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2018-06-11 Cont ID  
Sent By tklarge Date 2018-06-11 Time 06:55 Rev Time 0.00
Received By tklarge Date 2018-06-11 Time 06:26 Sent To I
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-06-04 Cont ID  
Sent By tklarge Date 2018-06-04 Time 10:32 Rev Time 0.00
Received By tklarge Date 2018-06-04 Time 06:25 Sent To I
Notes
2018-06-04 10:32:021) THERE IS A REFERENCE ON THE GAS PLAN TO SIZING TABLE
 402.4 (28). THIS TABLE IS FOR SIZING LP GAS, NOT
 NATURAL GAS. SUBMIT THE CORRECT TABLE.
 2) SHOW THE DISTANCE OF THE TANKLESS WATER HEATERS IN
 RELATION TO WINDOWS, DOORS AND OTHER BUILDING OPENINGS.
 THE TANKLESS WATER HEATER SHALL BE LOCATED A MINIMUM OF
 4 FEET FROM ANY OPERABLE WINDOW OR DOOR.
 3) THE GAS POOL HEATER SHALL HAVE A MINIMUM THERMAL
 EFFICIENCY OF 82% PER 2017 FBC-ENERGY
 SEC.R403.10.4.SUBMIT DOCUMENTATION THAT THE POOL HEATER
 MEETS THIS CRITERIA.
 NOTE: A HOOD WILL BE REQUIRED OVER THE GRILL. 2017
 FBCR-SEC. G2406.3.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-11 Cont ID  
Sent By tklarge Date 2018-06-11 Time 06:55 Rev Time 0.00
Received By tklarge Date 2018-06-06 Time 11:29 Sent To  
Notes
2018-06-07 11:29:34RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-04 Cont ID  
Sent By tklarge Date 2018-06-04 Time 10:46 Rev Time 0.00
Received By tklarge Date 2018-05-31 Time 11:27 Sent To  
Notes
2018-06-01 11:27:53PLUMB <5K