Plan Review Details - Permit 18051434
Plan Review Stops For Permit 18051434
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2018-08-27 Cont ID  
Sent By shill Date 2018-08-27 Time 14:11 Rev Time 0.00
Received By shill Date 2018-08-27 Time 14:11 Sent To  
Notes
2018-08-27 14:12:06UNIT A07
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2018-07-08 Cont ID  
Sent By shill Date 2018-07-08 Time 11:29 Rev Time 0.00
Received By shill Date 2018-07-08 Time 11:29 Sent To  
Notes
2018-07-08 11:29:18SEE BUILDING REVIEW
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-27 Cont ID  
Sent By shill Date 2018-08-27 Time 12:57 Rev Time 0.00
Received By shill Date 2018-08-27 Time 12:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-08 Cont ID  
Sent By shill Date 2018-07-08 Time 11:21 Rev Time 0.00
Received By shill Date 2018-07-08 Time 11:21 Sent To  
Notes
2018-07-08 11:29:00****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC 107, SHEET D1.0 AND OTHER PAGES INDICATE THAT
 WORK SHOWN ON THIS PLAN WILL BE DONE BY THE LANDLORD.
 WILL THIS BE A SEPARATE PERMIT WITH SEPARATE PLANS, OR
 A SEPARATE PERMIT UTILIZING THE PLAN SUBMITTED, OR WILL
 ALL WORK (INCLUDING LANDLORD WORK) BE COVERED UNDER
 THIS PERMIT? IT IS MY UNDERSTANDING THAT LANDLORD WANTS
 A SEPARATE PERMIT. IF THIS IS THE CASE, PLEASE REMOVE
 THE WORK TO BE COVERED UNDER THE LANDLORD'S PERMIT TO
 AVOID DISCREPANCIES.
  
 2. AS SOME WORK AFFECTS THE ADJACENT SPACE (SUCH AS
 INSTALLATION OF FRT PLYWOOD ON DEMISING WALL IN
 STOCKROOM), PROVIDE LANDLORD APPROVAL OF PERMIT
 DOCUMENTS, FBC 107.
  
 3. APPLICATION DOES NOT INCLUDE A SUITE NUMBER. FBC
 107, PROVIDE. A LOCATION PLAN WOULD BE HELPFUL TO
 ASSIGN CORRECT UNIT NUMBER IN OUR SYSTEM.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-27 Cont ID  
Sent By jpearson Date 2018-08-27 Time 13:47 Rev Time 0.00
Received By jpearson Date 2018-08-27 Time 13:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-07-12 Cont ID  
Sent By jpearson Date 2018-07-12 Time 15:36 Rev Time 0.00
Received By jpearson Date 2018-07-12 Time 15:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-08-03 Cont ID  
Sent By scaldero Date 2018-08-03 Time 11:05 Rev Time 0.00
Received By scaldero Date 2018-08-03 Time 10:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-06-04 Cont ID  
Sent By scaldero Date 2018-06-04 Time 11:08 Rev Time 0.00
Received By scaldero Date 2018-06-04 Time 10:01 Sent To  
Notes
2018-06-04 11:08:18PERMIT # 18051434
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FAILED COMMENTS:
  
 1) SHEET T1.1 EGRESS PLAN: STOCKROOM #2 IS CLASSIFIED
 AS A STORAGE OCCUPANCY. PER NFPA 101: CH 42 - TABLE
 42.2.5: THE MAXIMUM COMMON PATH OF TRAVEL IN A STORAGE
 OCCUPANCY IS 100 FEET.
  
 2) SHEET T1.1 EGRESS PLAN: PER NFPA 101, CH 42 -
 42.2.4.1: IN ORDINARY HAZARD STORAGE OCCUPANCIES, A
 SINGLE MEANS OF EGRESS SHALL BE PERMITTED FROM ANY
 STORY OR SECTION, PROVIDED THAT THE EXIT CAN BE REACHED
 WITHIN THE DISTANCE PERMITTED AS A COMMON PATH OF
 TRAVEL.
 BECAUSE THE COMMON PATH OF TRAVEL EXCEEDS 100 FEET, A
 SECOND MEANS OF EGRESS FROM STOCKROOM #2 IS REQUIRED.
  
 3) SHEET A1.1 FIXTURE PLAN: PLEASE PROVIDE DETAILS
 REGARDING HOW STORAGE WILL BE KEPT WITHIN STOCKROOM #2.
 PLEASE PROVIDE THE LAYOUT FOR ANY RACKS OR FIXTURES TO
 BE USED. PLEASE ALSO INCLUDE THE TYPE OF RACKS (FIXED,
 MOBILE, ETC.) AND THE MAXIMUM HEIGHT OF THE RACKS,
 INCLUDING STORAGE.
  
 4) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED BY EMAIL ([email protected])
 ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND
 APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT
 500 NORTH DIXIE HIGHWAY.
  
 5) ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A
 LOCK/UNLOCK INDICATOR.
  
 6) EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED
 WITH SIGNS OR STENCILING READING FIRE BARRIER-PROTECT
 ALL OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN
 HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE
 SPACED NOT MORE THAN 15 FEET ON CENTER.
  
 7) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN
 STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE
 MAINTAINED AT ALL TIMES.
  
 8) WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT
 SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED
 AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE
 MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM
 SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD
 INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY
 BE NEEDED.
  
 9) ALL TENANT SPACES FOR THE MARKETPLACE MUST BE TIED
 INTO THE MASTER FIRE ALARM PANEL FOR THE BUILDING. EACH
 TENANT SPACE WILL BE INTERCONNECTED AND UPON ACTIVATION
 OF AN ALARM IN ANY ONE SPACE, ALL SPACES WILL HAVE
 THEIR NOTIFICATION DEVICES ACTIVATE. AN FACP IN A
 TENANT SPACES WILL HAVE THE "RESET" AND "SILENCE"
 FUNCTIONS DEACTIVATED. RESET AND SILENCE OF AN ALARM IS
 LIMITED TO THE MASTER PANEL FOR THE BUILDING AND MAY
 ONLY BE DONE BY A LICENSED FIRE ALARM TECHNICIAN.
 SHOULD IT BE FOUND THAT TENANTS ARE ACCESSING THE
 PANELS IN THE TENANT SPACES AND/OR USING THE "RESET" OR
 "SILENCE" FUNCTIONS, THE OFFICE OF THE FIRE MARSHAL MAY
 REQUIRE THAT THE TENANT FACP BE REMOVED.
  
 10) PER APPROVED MASTER PLANS: MAIN FACP FOR THIS
 BUILDING IS TO BE THE ONLY PANEL TO NOTIFY THE FIRE
 DEPARMENT. NOTIFICATION WILL DESIGNATE SPECIFIC ADDRESS
 OF TENANT WHERE TROUBLE IS LOCATED. EACH BUILDING SHALL
 ALARM/EVACUATE ONLY THE SPACES IN THAT BUILDING (IE AN
 ALARM IN "B" WILL NOT EVACUATE ANY SPACE IN "A", "BII",
 OR "C". EACH TENANT SPACE FACP SHALL BE CONNECTED TO
 MAIN FACP FOR THIS BUILDING VIA MODULES. TENANT SYSTEM
 SHALL BE COMPATIBLE WITH NOTIFIER OR EQUAL APPROVED
 MAIN FACP/HARDWARE EACH FLOW/TAMPER SHALL BE ZONED SO
 THAT AN ALARM WILL SOUND FOR EACH BUILDING SEPARATELY.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-27 Cont ID  
Sent By skennedy Date 2018-08-27 Time 13:58 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 07:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-23 Cont ID  
Sent By tklarge Date 2018-07-23 Time 12:54 Rev Time 0.00
Received By lmarchan Date 2018-06-01 Time 15:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-06-29 Cont ID  
Sent By ccole Date 2018-06-29 Time 15:58 Rev Time 0.00
Received By ccole Date 2018-06-29 Time 15:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2018-08-27 Cont ID  
Sent By skennedy Date 2018-08-27 Time 13:58 Rev Time 0.00
Received By skennedy Date 2018-08-27 Time 13:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-07-23 Cont ID  
Sent By tklarge Date 2018-07-23 Time 12:53 Rev Time 0.00
Received By tklarge Date 2018-07-23 Time 12:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2018-08-27 Cont ID  
Sent By shill Date 2018-08-27 Time 14:40 Rev Time 0.00
Received By shill Date 2018-08-27 Time 14:40 Sent To  
Notes
2018-08-27 14:41:22SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PROVISO:
  
 1. THE COMCHECK IS NOT A DIGITALLY SIGNED AND SEALED
 ORIGINAL, FS471.
  
 PLEASE SEND TO ME VIA EMAIL.
  
 ***8/31/18 RECEIVED VIA EMAIL, FORWARDED TO PROJECTDOX
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2018-08-27 Cont ID  
Sent By shill Date 2018-08-27 Time 13:16 Rev Time 0.00
Received By shill Date 2018-08-27 Time 12:35 Sent To  
Notes
2018-08-27 13:16:27SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE COMCHECK IS NOT A DIGITALLY SIGNED AND SEALED
 ORIGINAL, FS471.
  
 PLEASE SEND TO ME VIA EMAIL.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-07-11 Cont ID  
Sent By shill Date 2018-07-11 Time 10:08 Rev Time 0.00
Received By shill Date 2018-07-11 Time 10:08 Sent To  
Notes
2018-07-08 11:29:54SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE COMCHECK IS NOT A DIGITALLY SIGNED AND SEALED
 ORIGINAL, FS471. TO AVOID A 2ND ELECTRICAL REVIEW, A
 SIGNED AND SEALED ORIGINAL DOCUMENT MAY BE SENT TO ME
 VIA EMAIL IF ELECTRICAL PASSES REVIEW. IF ELECTRICAL
 FAILS REVIEW, PLEASE UPLOAD A SIGNED AND SEALED
 ORIGINAL WHEN RESUBMITTING.
  
 2. OTHER DOCUMENTS HAVE SIGNATURE & SEAL WHICH COMPLY
 WITH FS471 AND FS481. NEW DOCUMENTS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-08-22 Cont ID  
Sent By eschneid Date 2018-08-22 Time 16:47 Rev Time 0.25
Received By eschneid Date 2018-08-22 Time 16:27 Sent To  
Notes
2018-08-22 16:47:04 
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-06-12 Cont ID  
Sent By eschneid Date 2018-06-12 Time 12:30 Rev Time 1.00
Received By eschneid Date 2018-06-12 Time 12:30 Sent To  
Notes
2018-06-12 14:37:14FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) PLEASE PROVIDE EITHER THE PALM BEACH OUTLETS
 MANAGEMENT APPROVAL STAMP ON THE PLANS OR A LETTER FROM
 THE PALM BEACH OUTLETS MANAGEMENT THAT APPROVED THE
 SPECIFIC PLANS SUBMITTED.
  
 2) SHEET D1.0 STATES THAT THE NEW STOREFRONT SYSTEM AND
 DOORS ARE TO BE SUPPLIED AND INSTALLED BY THE LANDLORD
 UNDER A SEPARATE PERMIT. NO PERMIT HAS BEEN SUBMITTED
 FOR THESE ITEMS. THE STOREFRONT PERMIT NEEDS TO BE
 SUBMITTED PRIOR TO ZONING APPROVAL OF THIS PERMIT.
  
 3) SHEET D1.0 STATES THAT THERE WILL BE LANDSCAPE
 REMOVED FROM THE EXTERIOR OF THE STORE. LANDSCAPE MAY
 NOT BE REMOVED WITHOUT PRIOR APPROVAL OF THE CITY
 PLANNING DIVISION, WHICH HAS NOT OCCURRED. EITHER THE
 NOTE NEEDS TO BE REMOVED FROM THE PLANS, WITH NO
 LANDSCAPE BEING REMOVED, OR THE LANDLORD NEEDS TO
 SECURE APPROVAL FROM THE PLANNING DIVISION FOR
 LANDSCAPE REMOVAL PRIOR TO ZONING APPROVAL OF THIS
 PERMIT.
  
 4) SHEET D1.0 STATES THAT THE "EXISTING SHOPPING CART
 RACK" WILL BE REMOVED. THIS IS NOT A SHOPPING CART
 RACK, BUT RATHER REQUIRED BICYCLE PARKING FOR THE PALM
 BEACH OUTLETS. THESE MAY NOT BE REMOVED AND THE NOTE
 MUST BE REMOVED FROM THE PLAN.
  
 5) MERCHANDISE IS NOT PERMITTED TO BE DISPLAYED OUTSIDE
 OF THE STORE. THE WIRE CAGES (LF-13B) SHOWN ON SHEET
 A1.1 MUST BE REMOVED.
  
 6) SIGNAGE IS REVIEWED UNDER SEPARATE PERMITTING TO
 VERIFY COMPLIANCE WITH THE PALM BEACH OUTLET
 ALLOWANCES. THE WINDOW SIGN FASTENERS SHOWN ON SHEET
 A3.1 ARE THE SIGN BRACKETS AND MUST BE REMOVED FROM
 THIS SET OF PLANS.
  
 7) THE EYELETS FOR THE "GRAND OPENING" ARE TO BE
 INCLUDED UNDER THAT SIGN PERMIT AND NOT AS PART OF THIS
 PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]
  
  