Plan Review Details - Permit 18051393
| Plan Review Stops For Permit 18051393 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2018-06-06 |
|
|
Cont ID |
|
| Sent By |
hhall |
Date |
2018-06-06 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
hhall |
Date |
2018-06-06 |
Time |
13:23 |
Sent To |
I |
|
| Notes |
| 2018-06-06 13:39:28 | 8" WATER MAIN IN SWALE (SEE INCLUDED ASBUILT) | | | ADDRESS ZONING COMMENTS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-07-18 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-07-10 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2018-07-11 15:33:59 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-06 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-06-06 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-05-30 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2018-05-31 15:03:09 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-17 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-17 |
Time |
09:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-06-05 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-06-05 |
Time |
11:20 |
Sent To |
ENG |
|
| Notes |
| 2018-06-05 11:24:01 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) INDICATE ON SURVEYS WIDTH OF EXISTING AND PROPOSED | | | DRIVEWAYS. TWO DRIVEWAYS ON A LOT MUST BE TOTAL 20 FEET | | | AND ACCESS FOR CIRCULAR DRIVEWAYS SHALL BE 10 FEET WIDE | | | EACH, SEE ENCLOSED ILLUSTRATION FOR YOUR REFERENCE. | | | 2) INDICATE THE SETBACK FROM THE PROPOSED DRIVEWAY TO | | | THE SIDE PROPERTY LINE, SHOULD BE AT LEAST 3 FEET. | | | 3) ENSURE FRONT YARD MEETS LANDSCAPING REQUIREMENTS, | | | WHEREBY, THE LESSER OF 1,000 SQUARE FEET OR 75 PERCENT | | | OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH LIVING | | | PLANT MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, | | | HEDGES, VINES OR TREES). | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
|