| Plan Review Stops For Permit 18051383 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-27 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-27 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-24 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-19 |
Time |
15:29 |
Sent To |
I |
|
| Notes |
| 2018-09-24 08:00:49 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOF COVERING. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-05 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-05 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2018-06-05 09:17:17 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. APPLIANCES APPEAR TO BE LOCATED OUTSIDE STRUCTURE. | | | APPLIANCES TO BE LISTED FOR EXTERIOR USE. PROVIDE | | | MANUFACTURERS INSTALLATION INSTRUCTIONS. | | | 2. APPLIANCES TO BE INSTALLED ON STABLE SURFACE. SHOW | | | TYPE OF FLOORING APPLIANCES WILL BE SET ON. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-31 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-31 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-04 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-04 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-24 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-05 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-30 |
Time |
16:06 |
Sent To |
I |
|
| Notes |
| 2018-05-31 16:06:50 | REVISION ROUTED TO GJOHNSON |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-27 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-27 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-13 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-13 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2018-09-13 11:37:45 | 1ST REVIEW FBC-2017 MECHANICAL | | | REVISION #18051383 | | | MASTER #17061198 | | | 9/13/18 | | | | | | | | | CODES IN EFFECT: | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) MAKEUP AIR IS REQUIRED FOR THE DRYER EXHAUST IN THE | | | NEW LAUNDRY ROOM- SECTION 504.6 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | HTTPS://WWW.SURVEYMONKEY.COM/R/WESTPALMBEACHCONSTRUCTIO | | | NSERVICES | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-27 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-27 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-09-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-19 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-19 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2018-09-19 08:29:13 | 2ND REVIEW: FBC 2014 5TH EDITION | | | PERMIT 18051383 | | | PLUMBING COMMENTS | | | | | | ONLY ONE SHEET 3.1 WAS SUBMITTED. WHEN RESUBMITTING, | | | PROVIDE A 2ND SET. | | | | | | PROVISO | | | | | | 1. PLAN SHT. 3.1 ADD 4; THE HORIZONTAL BRANCH DRAINS | | | FOR THE WASHING MACHINES SHALL BE 3" PER MANUFACTURE | | | SPECIFICATION FOR STUDOR VENT FOR A WASHING MACHINE AS | | | RED LINED ON THE SANITARY ISOMETRIC. | | | 2. CONTRACTORS COPY PLAN SHT. 3.1 ADD 4. WAS NOT | | | INCLUDED IN SUBMITTAL PACKAGE. A SCANNED COPY OF THE | | | AFFECTED RED LINED PORTION OF THE PLAN HAS BEEN | | | ATTACHED TO CONTRACTOR'S PLAN SHEET 2.1 FOR | | | CONTRACTOR'S USE. CONTRACTOR SHALL OBTAIN A SCANNED | | | COPY OF FULL RED LINED PLAN SHEET THROUGH THE BUILDING | | | DEPARTMENT FOR A FEE. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6715 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-04 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-04 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2018-06-04 11:59:12 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. 2.1 ON THE APPROVED SET OF PLANS IT SHOWS AN | | | EXISTING STORAGE ROOM IN THE LOCATION OF THE NEW | | | STACKABLE WASHERS AND DRYERS THE REVISED SHEET DOES NOT | | | SHOW EXISTING STORAGE PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 2. SHT. 2.1 THE NEW WASHERS AND DRYERS APPEAR TO BE ON | | | THE EXTERIOR OF THE BUILDING THE APPLIANCE SHALL BE | | | RATED FOR USE ON EXTERIOR AND IN DAMP LOCATIONS PLEASE | | | PROVIDE MANUFACTURE SPECIFICATIONS SHOWING THAT THEY | | | ARE APPROVED FOR THIS USE. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. SHT. 3.1 THE FIXTURE BRANCH DRAINS FOR THE WASHING | | | MACHINES SHALL BE 3" PER MANUFACTURE SPECIFICATION FOR | | | STUDOR VENT FOR A WASHING MACHINE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|