Plan Review Details - Permit 18051293
| Plan Review Stops For Permit 18051293 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-19 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-18 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-09-17 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-09-17 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-09-17 |
Time |
06:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-06-12 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-06-12 |
Time |
06:35 |
Sent To |
B |
|
| Notes |
| 2018-06-12 07:17:11 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. CITY PLACE APPROVAL STAMP OR LETTER OF APPROVAL FROM | | | CITY PLACE REQUIRED FOR SIGN. | | | | | | 2. DISCONNECT REQUIRED IN-SIGHT OF SIGN TO DISCONNECT | | | ALL UNGROUNDED CONDUCTORS BEFORE IT ENTERS SIGN. NEC | | | 600.6A (1) | | | | | | 3. ELECTRICAL SUB-PERMIT ASSOCIATED WITH SIGN | | | (#18051294) CAN NOT BE ISSUED TO A CONTRACTOR HOLDING | | | ONLY AN ES LICENSE SINCE PROPOSED PLAN SHOWS THE NEED | | | FOR ADDITIONAL ELECTRICAL WORK TO COMPLY WITH | | | DISCONNECT REQUIREMENTS OF NEC 600.6A(1) FOR SIGN. F.S. | | | 489 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2018-09-27 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2018-09-19 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2018-09-20 12:13:28 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-17 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-09-17 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-09-11 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2018-09-13 09:56:17 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-19 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-25 |
Time |
08:59 |
Sent To |
I |
|
| Notes |
| 2018-05-30 08:59:51 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2018-09-27 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2018-09-27 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-09-13 |
Time |
15:47 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-09-13 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2018-09-13 16:40:38 | FAILED | | | | | | THE PLANS APPROVED BY CITYPLACE SHOW A 6.45 SF SIGN | | | (WALL MOUNTED OVER DOOR). THE PERMIT PLANS SHOW A 17 SF | | | SIGN, WHICH IS LARGER THAN THE SIGN CITYPLACE HAS | | | APPROVED. ZONING STAFF CANNOT APPROVE A SIGN LARGER | | | THAN THE ONE APPROVED BY CITYPLACE. PLEASE PROVIDE A | | | REVISED APPROVAL FROM CITYPLACE FOR THE LARGER SIGN OR | | | PROVIDE THE PERMIT INFORMATION FOR THE SIZE OF THE SIGN | | | APPROVED BY CITYPLACE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-06-07 |
Time |
16:46 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2018-06-07 |
Time |
16:46 |
Sent To |
E |
|
| Notes |
| 2018-06-12 09:45:23 | FAILED | | | | | | THE CITYPLACE MANAGEMET STAMP IS REQUIRED ON THE PLANS. | | | | | | BOTH SIGNS ARE SMALLER THAN THE ONES THEY REPLACE. | | | | | | UPPER SIGN: 61.86 SF | | | | | | LOWER SIGN: 17 SF |
|
|
|