Plan Review Details - Permit 18051235
| Plan Review Stops For Permit 18051235 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-28 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-28 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-15 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-15 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2019-02-15 09:26:21 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ADVISORY: | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW | | | | | | THE FOLLOWING COMMENTS HAVE NOT BEEN ADDRESSED FROM | | | PREVIOUS REVIEWS. | | | | | | | | | 1. OK. | | | | | | 2. [FBC R301]PROVIDE 2 COPIES OF SURVEY THAT WILL | | | INDICATE THE UTILITY EASEMENT ON THE SOUTH SIDE OF | | | PROPERTY. IF ANY PART OF NEW GARAGE ENCROACHES INTO THE | | | EASEMENT THEN MOVE GARAGE LOCATION ACCORDINGLY OR | | | OBTAIN EASEMENT CONSENTS FROM EASEMENT HOLDERS. | | | 2-4. SURVEY NOT PROVIDED. | | | | | | 3-9. OK. | | | | | | 10. [FBC R301.1.2]PROVIDE NOTICE OF APPROVAL(N.O.A.) | | | FOR ALL WINDOWS, DOORS AND GARAGE DOORS. IF ANY GLAZING | | | IS NON-IMPACT RATED THEM PROVIDE PROPOSED PROTECTION | | | AND ATTACHMNET AS OUTLINED IN R301.1.2. | | | 10-4. NO PRODUCT APPROVALS SUBMITTED. SINCE NO COMMENT | | | RESPONSE SHEET PROVIDED I DON?T KNOW IF THEY ARE TO BE | | | DEFFERED. PROVIDE APPROVALS, OR INDICATE THAT THEY ARE | | | TO BE DEFFERED. | | | | | | 11-15 OK. | | | | | | 16. [FBC 107.2.1]PROVIDE PRODUCT APPROVALS FOR ROOFING | | | MATERIALS. FOR THE FLAT ROOF, INDICATE ASSEMBLY | | | PROPOSED AND PROVIDE ENGINEERING IF ASSEMBLY DOES NOT | | | MEET THE DESIGN PRESSURES FOR ZONES 2 & 3. | | | 16-4. NO PRODUCT APPROVALS SUBMITTED. SINCE NO COMMENT | | | RESPONSE SHEET PROVIDED I DON?T KNOW IF THEY ARE TO BE | | | DEFFERED. PROVIDE APPROVALS, OR INDICATE THAT THEY ARE | | | TO BE DEFFERED. | | | | | | | | | 17-18. OK. | | | | | | 19. FLORIDA STATUTE 481, DOCUMENTS PREPARED BY AN | | | ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. | | | 19-3. ONLY PAGE A101 IS SIGNED/SEALED BY ARCHITECT. | | | 19-4. ONLY ONE SET OF ARCHITECTURAL DRAWINGS PROVIDED. | | | ALL OTHER PLAN SHEETS ARE SIGNED AND SEALED. PROVIDE | | | SECOND SET OF ARCHITECTURALS, SIGNED AND SEALED. | | | | | | | | | 20-21. OK. | | | | | | 22. OK | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-11 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2019-01-11 15:37:39 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ADVISORY: | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW | | | | | | THE FOLLOWING COMMENTS HAVE NOT BEEN ADDRESSED FROM | | | PREVIOUS REVIEWS. | | | | | | | | | 1. OK. | | | | | | 2. [FBC R301]PROVIDE 2 COPIES OF SURVEY THAT WILL | | | INDICATE THE UTILITY EASEMENT ON THE SOUTH SIDE OF | | | PROPERTY. IF ANY PART OF NEW GARAGE ENCROACHES INTO THE | | | EASEMENT THEN MOVE GARAGE LOCATION ACCORDINGLY OR | | | OBTAIN EASEMENT CONSENTS FROM EASEMENT HOLDERS. | | | 2-3. SURVEY NOT PROVIDED. | | | | | | 3-9. OK. | | | | | | 10. [FBC R301.1.2]PROVIDE NOTICE OF APPROVAL(N.O.A.) | | | FOR ALL WINDOWS, DOORS AND GARAGE DOORS. IF ANY GLAZING | | | IS NON-IMPACT RATED THEM PROVIDE PROPOSED PROTECTION | | | AND ATTACHMNET AS OUTLINED IN R301.1.2. | | | 10-3. NO PRODUCT APPROVALS SUBMITTED. SINCE NO COMMENT | | | RESPONSE SHEET PROVIDED I DON?T KNOW IF THEY ARE TO BE | | | DEFFERED. PROVIDE APPROVALS, OR INDICATE THAT THEY ARE | | | TO BE DEFFERED. | | | | | | 11-15 OK. | | | | | | 16. [FBC 107.2.1]PROVIDE PRODUCT APPROVALS FOR ROOFING | | | MATERIALS. FOR THE FLAT ROOF, INDICATE ASSEMBLY | | | PROPOSED AND PROVIDE ENGINEERING IF ASSEMBLY DOES NOT | | | MEET THE DESIGN PRESSURES FOR ZONES 2 & 3. | | | 16-3. NO PRODUCT APPROVALS SUBMITTED. SINCE NO COMMENT | | | RESPONSE SHEET PROVIDED I DON?T KNOW IF THEY ARE TO BE | | | DEFFERED. PROVIDE APPROVALS, OR INDICATE THAT THEY ARE | | | TO BE DEFFERED. | | | | | | | | | 17-18. OK. | | | | | | 19. FLORIDA STATUTE 481, DOCUMENTS PREPARED BY AN | | | ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. | | | 19-3. ONLY PAGE A101 IS SIGNED/SEALED BY ARCHITECT. | | | | | | 20-21. OK. | | | | | | 22. FBC 107, SEPARATE PERMITS ARE REQUIRED; ONE PERMIT | | | FOR THE MAIN HOUSE, ONE PERMIT FOR THE GARAGE. PROVIDE | | | VALUE FOR EACH. | | | 22-3 COMMENT NOT ADDRESSED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-22 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-22 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2018-08-22 16:45:35 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18051235 | | | REVIEWED: AUGUST 22, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC EB = FBC EXISTING BUILDING | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. OK. | | | | | | 2. [FBC R301]PROVIDE 2 COPIES OF SURVEY THAT WILL | | | INDICATE THE UTILITY EASEMENT ON THE SOUTH SIDE OF | | | PROPERTY. IF ANY PART OF NEW GARAGE ENCROACHES INTO THE | | | EASEMENT THEN MOVE GARAGE LOCATION ACCORDINGLY OR | | | OBTAIN EASEMENT CONSENTS FROM EASEMENT HOLDERS. | | | 2-2. SURVEY NOT PROVIDED. | | | | | | 3-9. OK. | | | | | | 10. [FBC R301.1.2]PROVIDE NOTICE OF APPROVAL(N.O.A.) | | | FOR ALL WINDOWS, DOORS AND GARAGE DOORS. IF ANY GLAZING | | | IS NON-IMPACT RATED THEM PROVIDE PROPOSED PROTECTION | | | AND ATTACHMNET AS OUTLINED IN R301.1.2. | | | 10-2. NO PRODUCT APPROVALS SUBMITTED. SINCE NO COMMENT | | | RESPONSE SHEET PROVIDED I DON?T KNOW IF THEY ARE TO BE | | | DEFFERED. PROVIDE APPROVALS, OR INDICATE THAT THEY ARE | | | TO BE DEFFERED. | | | | | | 11-15 OK. | | | | | | 16. [FBC 107.2.1]PROVIDE PRODUCT APPROVALS FOR ROOFING | | | MATERIALS. FOR THE FLAT ROOF, INDICATE ASSEMBLY | | | PROPOSED AND PROVIDE ENGINEERING IF ASSEMBLY DOES NOT | | | MEET THE DESIGN PRESSURES FOR ZONES 2 & 3. | | | 16-2. NO PRODUCT APPROVALS SUBMITTED. SINCE NO COMMENT | | | RESPONSE SHEET PROVIDED I DON?T KNOW IF THEY ARE TO BE | | | DEFFERED. PROVIDE APPROVALS, OR INDICATE THAT THEY ARE | | | TO BE DEFFERED. | | | | | | | | | 17-18. OK. | | | | | | 19. FLORIDA STATUTE 481, DOCUMENTS PREPARED BY AN | | | ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. | | | 19-2. ONLY PAGE A101 IS SIGNED/SEALED BY ARCHITECT. | | | | | | 20-21. OK. | | | | | | 22. FBC 107, SEPARATE PERMITS ARE REQUIRED; ONE PERMIT | | | FOR THE MAIN HOUSE, ONE PERMIT FOR THE GARAGE. PROVIDE | | | VALUE FOR EACH. | | | 22-2 COMMENT NOT ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-28 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-28 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2018-06-28 17:04:19 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18051235 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. INFO ONLY - [FL. STATUTE 713.13]FILE NOTICE OF | | | COMMENCEMENT(N.O.C) WITH THE CLERK OF THE COURT AND | | | PROVIDE CERTIFIED COPY TO WPB BUILDING DEPARTMENT PRIOR | | | TO SCHEDULING FIRST INSPECTION. THE N.O.C. MUST BE | | | SIGNED BY THE OWNER.(REQUIRED FOR VALUE OF $2500 AND | | | ABOVE FOR IMPROVEMENTS TO REAL PROPERTY). | | | | | | 2. [FBC R301]PROVIDE 2 COPIES OF SURVEY THAT WILL | | | INDICATE THE UTILITY EASEMENT ON THE SOUTH SIDE OF | | | PROPERTY. IF ANY PART OF NEW GARAGE ENCROACHES INTO THE | | | EASEMENT THEN MOVE GARAGE LOCATION ACCORDINGLY OR | | | OBTAIN EASEMENT CONSENTS FROM EASEMENT HOLDERS. | | | | | | 3. [FBC 107.3.5.3]FINISHED FLOOR ELEVATION NEEDS TO BE | | | ESTABLISHED. | | | | | | 4. [FBC R401.3] PROVIDE DRAINAGE PLAN FOR NEW GARAGE | | | AND ANY NEW IMPERVIOUS SURFACES TO SHOW COMPLIANCE WITH | | | R401.3 | | | USE ESTABLISHED FINISHED FLOOR ELEVATION OF GARAGE AS | | | BASIS OF DESIGN TO SHOW HOW WATER GETS TO THE STREET | | | STORM DRAIN. | | | | | | 5. [FBC 107.3.5.3]SHEET A203 AT THE BOTTOM OF PAGE IS | | | LABELED NORTH, BUT IT IS SOUTH ELEVATION. | | | | | | 6. [FBC 107.3.5.3]MULTIPLE SHEETS REFER TO SEE | | | STRUCTURAL SHEET, BUT THERE IS NO STRUCTURAL SHEET. | | | PLEASE PROVIDE STRUCTURAL AS COMMENTS TO FOLLOW ARE | | | REQUESTING ADDITIONAL STRUCTURAL INFORMATION. | | | | | | 7. [FBC R401.4]PROVIDE DESIGN CRITERIA FOR NEW GARAGE | | | INCLUDING SOIL REPORT, BEARING CAPACITY, WIND DESIGN | | | CRITERIA. | | | | | | 8. [FBC R301.2.1]PROVIDE DESIGN PRESSURES NEEDED FOR | | | WINDOWS, DOORS, GARAGE DOOR, CLADDING AND COMPONENTS. | | | | | | 9. [FBC R703.4]PROVIDE TYPE OF WINDOW/DOOR FLASHING TO | | | BE USED TO MEET REQUIREMNETS OF R703.4 | | | | | | 10. [FBC R301.1.2]PROVIDE NOTICE OF APPROVAL(N.O.A.) | | | FOR ALL WINDOWS, DOORS AND GARAGE DOORS. IF ANY GLAZING | | | IS NON-IMPACT RATED THEM PROVIDE PROPOSED PROTECTION | | | AND ATTACHMNET AS OUTLINED IN R301.1.2. | | | | | | IF ITEMS PROPOSED ARE NOT KNOWN AT THIS TIME, THEY MAY | | | BE DEFERRED. | | | | | | FBC 107, ALL PRODUCT APPROVALS ARE TO BE REVIEWED BY | | | DESIGN PROFESIONAL PRIOR TO SUBMITTAL. | | | STAMP EACH N.O.A AS REVIEWED, OR PROVIDE ONE REVIEW | | | SHEET LISTING ALL PRODUCT APPROVALS REVIEWED AND | | | APPROVED. | | | | | | 11. [FBC 107.3.5.3]PROVIDE DETAILS OF HOW NEW OVERHANGS | | | AND PORCH ARE CONNECTED TO EXISTING AND HOW THEY MEET | | | WIND LOAD DESIGN CRITERIA. CALL OUT EXISTING STEEL | | | COLUMNS AND FOOTERS AND DETAIL HOW THEY MEET DESIGN | | | CRITERIA FOR UPLIFT AND GRAVITY LOADS. IF APPLICABLE | | | PROVIDE PAD DETAILS AND POST CONNECTIONS. | | | | | | 12. [FBC EX807.4]PROVIDE MEANS THAT WERE USED TO | | | DETERMINE INTERIOR WALLS TO BE DEMOLISHED ARE NON-LOAD | | | BEARING, AND PROVIDE BACK-UP TO SUPPORT FINDINGS. | | | | | | 13. [FBC 107.3.5.3]PROVIDE STRUCTURAL DETAILS OF MAIN | | | HOUSE INTERIOR CEILING MODIFICATIONS AS INDICATED ON | | | A103. | | | | | | 14. [FBC R602.5]PROVIDE DETAIL OF PROPOSED PARTION AND | | | INFILL. LIST MATERIALS, SPACING AND CONNECTIONS. | | | | | | 15. [FBC 107.3.5.3]PROVIDE ROOF PLAN FOR NEW GARAGE TO | | | ROOF SLOPE AND SCUPPER LOCATIONS. THE DETAIL ON SHEET | | | A501 SHOULD COMPLIMENT THE ROOF PLAN. LABLE CONNECTORS | | | TO BE USED IN DETAILS AND SECTIONS PROVIDED. | | | | | | 16. [FBC 107.2.1]PROVIDE PRODUCT APPROVALS FOR ROOFING | | | MATERIALS. FOR THE FLAT ROOF, INDICATE ASSEMBLY | | | PROPOSED AND PROVIDE ENGINEERING IF ASSEMBLY DOES NOT | | | MEET THE DESIGN PRESSURES FOR ZONES 2 & 3. | | | | | | THIS MAY BE DEFERRED UPON REQUEST AND SUBMITTED WITH | | | THE ROOF PERMIT APPLICATION PRIOR TO INSTALLATION. | | | | | | 17. [FBC R308.1]SHOWER ENCLOSURES TO COMPLY WITH SAFETY | | | GLASS STANDARDS IN FBC R308.1 | | | | | | 18. [FBC R702.4.2]PROVIDE TILE BACKER IN SHOWER | | | COMPARTMENTS THAT COMPLY WITH TABLE R702.4.2. | | | | | | 19. FLORIDA STATUTE 481, DOCUMENTS PREPARED BY AN | | | ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. | | | | | | 20. A PORTION OF THE FIRST PAGE WAS CROSSED OFF; ONLY | | | THE ARCHITECT CAN ALTER THE PLAN, FS481. | | | | | | 21. A101 REFERS TO INCORRECT GOVERNING CODE; REVISE TO | | | FBC 2017 RESIDENTIAL. | | | | | | 22. FBC 107, SEPARATE PERMITS ARE REQUIRED; ONE PERMIT | | | FOR THE MAIN HOUSE, ONE PERMIT FOR THE GARAGE. PROVIDE | | | VALUE FOR EACH. | | | | | | | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | PLEASE PROVIDE TWO IDENTICAL COPIES OF ALL ITEMS | | | SUBMITTED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-15 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-15 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-11 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2019-01-11 16:18:17 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE EQUIPMENT GROUNDING CONDUCTOR BETWEE MAIN | | | PANEL AND GARAGE SUB-PANEL. PER FBC R E3607.3.1 | | | E3607.3.1 EQUIPMENT GROUNDING CONDUCTOR. | | | | | | AN EQUIPMENT GROUNDING CONDUCTOR AS DESCRIBED IN | | | SECTION E3908 SHALL BE RUN WITH THE SUPPLY CONDUCTORS | | | AND CONNECTED TO THE BUILDING OR STRUCTURE | | | DISCONNECTING MEANS AND TO THE GROUNDING ELECTRODE(S). | | | THE EQUIPMENT GROUNDING CONDUCTOR SHALL BE USED FOR | | | GROUNDING OR BONDING OF EQUIPMENT, STRUCTURES OR FRAMES | | | REQUIRED TO BE GROUNDED OR BONDED. THE EQUIPMENT | | | GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH | | | SECTION E3908.12. ANY INSTALLED GROUNDED CONDUCTOR | | | SHALL NOT BE CONNECTED TO THE EQUIPMENT GROUNDING | | | CONDUCTOR OR TO THE GROUNDING ELECTRODE(S). [250.32(B) | | | AND TABLE 250.122] | | | | | | 2. PROVIDE AVAILABLE FAULT CURRENT FROM FPL. | | | AIC RATING OF SERVICE DISCONNECT AND PANEL | | | FBC R E3606.3AVAILABLE SHORT-CIRCUIT CURRENT. | | | SERVICE EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM | | | FAULT CURRENT AVAILABLE AT ITS SUPPLY TERMINALS, BUT | | | NOT LESS THAN 10,000 AMPERES. (110.9) | | | | | | SEPERATE PERMIT REQUIRED FOR DETACHED GARAGE | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-14 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-14 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2018-08-14 16:15:41 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | | | | NEW COMMENTS: | | | | | | 5. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 | | | 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 8. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC | | | 109.3 | | | 9. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | | R314.3(4), NFPA 72:29.8.3.4 | | | 10. PLAN IS NOT SIGNED BY THE DESIGN PROFESSIONAL. A | | | COPY OF THE ENGINEERS SIGNATURE IS NOT ACCEPTABLE. WPB | | | FBC 107.1 AND 107.2; SECTION 61G15-23.005 FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-22 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2018-06-22 11:12:02 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | RE R314.3, R315.1; WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-06-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-25 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-25 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2018-06-25 14:28:10 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-01-04 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-01-04 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-07-30 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-07-30 |
Time |
15:01 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-06-12 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-06-12 |
Time |
15:31 |
Sent To |
I |
|
| Notes |
| 2018-06-12 15:33:56 | 6/12/2018 - HISTORIC PRESERVATION BOARD APPROVAL (HPB | | | 18-07) PER THE FEBRUARY 28, 2018 MEETING. DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-15 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-11 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2019-02-12 11:10:53 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-11 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-18 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-04 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-04 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-28 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-24 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-15 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-15 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-11 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2019-01-11 15:42:54 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DESIGN PROFESSIONAL SHALL SIGN AND SEAL PLAN. | | | | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | FBC 107.1 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, | | | INTERIOR DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER | | | LEGALLY REGISTERED UNDER THE LAWS OF THIS STATE | | | REGULATING THE PRACTICE OF ARCHITECTURE OR INTERIOR | | | DESIGN AS PROVIDED FOR IN CHAPTER 481, FLORIDA | | | STATUTES, PART I, OR LANDSCAPE ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. | | | | | | SEPERATE PERMIT REQUIRED FOR DETACHED GARAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-08-06 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-08-06 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-06-20 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-06-20 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-15 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-15 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-11 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2019-01-11 16:21:41 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DESIGN PROFESSIONAL SHALL SIGN AND SEAL PLAN. | | | | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | FBC 107.1 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, | | | INTERIOR DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER | | | LEGALLY REGISTERED UNDER THE LAWS OF THIS STATE | | | REGULATING THE PRACTICE OF ARCHITECTURE OR INTERIOR | | | DESIGN AS PROVIDED FOR IN CHAPTER 481, FLORIDA | | | STATUTES, PART I, OR LANDSCAPE ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. | | | | | | 2. SEPERATE PERMIT REQUIRED FOR DETACHED GARAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-02 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-02 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-04 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2018-09-04 08:46:26 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE SANITARY ISOMETRIC DRAWING. PER WPB AMEND TO | | | FBC 107.3.5.3(12) | | | | | | 2. PROVIDE NOTE: THE VALVES FOR THE STACKABLE WASHING | | | MACHINE SHALL BE ACCESSIBLE. PER FBC RES P2903.9.3 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-25 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-25 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2018-06-25 14:27:17 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE SANITARY ISOMETRIC DRAWING. PER WPB AMEND TO | | | FBC 107.3.5.3(12) | | | | | | 2. THE VALVES FOR THE STACKABLE WASHING MACHINE SHALL | | | BE ACCESSIBLE. PER FBC RES P2903.9.3 | | | | | | 3. THE TANKLESS HEATER SHALL BE MOUNTED A MINIMUM OF 4' | | | FROM ANY OPENINGS IN THE BUILDING. ANSI Z223.1 NFPA 54 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
N |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-28 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-28 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2019-02-28 11:05:01 | NO ROOFING ON PLANS FOR THE MAIN HOUSE RENOVATIONS. | | | THE GARAGE (19020474) WILL HAVE ROOFING SUB PERMIT. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-15 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-15 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2019-02-15 10:30:28 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM | | | COMPONENTS. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-11 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2019-01-11 15:28:34 | PLEASE SEE COMMENTS UNDER BLDG. REVIEW. CT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-04 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-04 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2018-09-04 08:49:44 | NO ROOF INFORMATION PROVIDED; SEE BUILDING REVIEW | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-28 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-28 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2018-06-28 17:05:12 | NO ROOF INFORMATION PROVIDED; SEE BUILDING REVIEW | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-01-04 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-01-04 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-07-30 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-07-30 |
Time |
15:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-06-12 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-06-12 |
Time |
15:31 |
Sent To |
HIST |
|
| Notes |
|
|
|