| Plan Review Stops For Permit 18051202 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-17 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-17 |
Time |
07:07 |
Sent To |
I |
|
| Notes |
| 2018-07-17 07:09:29 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | THE POOL IS LOCATED IN A SPECIAL FLOOD HAZARD AREA. THE | | | POOL EQUIPMENT IS REQUIRED TO BE AT OR ABOVE THE | | | HABITABLE FLOOR ELEVATION OF THE DWELLING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-22 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-22 |
Time |
11:22 |
Sent To |
I |
|
| Notes |
| 2018-06-22 11:39:26 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | THE POOL IS LOCATED IN A SPECIAL FLOOD HAZARD AREA. THE | | | POOL EQUIPMENT IS REQUIRED TO BE AT OR ABOVE THE | | | HABITABLE FLOOR ELEVATION OF THE DWELLING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-08 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-08 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-06-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-03 |
Time |
04:22 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-03 |
Time |
04:22 |
Sent To |
|
|
| Notes |
| 2018-06-03 04:22:53 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-17 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-06 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2018-07-09 14:15:50 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-22 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-24 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2018-05-25 11:09:33 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-17 |
Time |
05:11 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-17 |
Time |
04:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-03 |
Time |
04:22 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-03 |
Time |
04:00 |
Sent To |
|
|
| Notes |
| 2018-06-03 04:18:19 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER). | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN | | | DRAIN AND THE PUMP. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-12 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-12 |
Time |
14:37 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-05-31 |
Time |
09:16 |
Sent To |
B |
|
| Notes |
| 2018-05-31 10:06:55 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) INDICATE SETBACK FROM POOL EQUIPMENT TO REAR | | | PROPERTY LINE. MUST BE AT 11 FEET. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | 561-822-1442 | | | [email protected] |
|
|