Plan Review Details - Permit 18051202
Plan Review Stops For Permit 18051202
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-07-17 Cont ID  
Sent By rmcdouga Date 2018-07-17 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2018-07-17 Time 07:07 Sent To I
Notes
2018-07-17 07:09:29FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  
 THE POOL IS LOCATED IN A SPECIAL FLOOD HAZARD AREA. THE
 POOL EQUIPMENT IS REQUIRED TO BE AT OR ABOVE THE
 HABITABLE FLOOR ELEVATION OF THE DWELLING.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-22 Cont ID  
Sent By rmcdouga Date 2018-06-22 Time 11:39 Rev Time 0.00
Received By rmcdouga Date 2018-06-22 Time 11:22 Sent To I
Notes
2018-06-22 11:39:26FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  
 THE POOL IS LOCATED IN A SPECIAL FLOOD HAZARD AREA. THE
 POOL EQUIPMENT IS REQUIRED TO BE AT OR ABOVE THE
 HABITABLE FLOOR ELEVATION OF THE DWELLING.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-06-08 Cont ID  
Sent By jleahy Date 2018-06-08 Time 17:02 Rev Time 0.00
Received By jleahy Date 2018-06-08 Time 17:02 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-06-03 Cont ID  
Sent By tklarge Date 2018-06-03 Time 04:22 Rev Time 0.00
Received By tklarge Date 2018-06-03 Time 04:22 Sent To  
Notes
2018-06-03 04:22:53A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-07-17 Cont ID  
Sent By rmcdouga Date 2018-07-17 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2018-07-06 Time 14:15 Sent To  
Notes
2018-07-09 14:15:50RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-22 Cont ID  
Sent By rmcdouga Date 2018-06-22 Time 11:40 Rev Time 0.00
Received By rmcdouga Date 2018-05-24 Time 11:09 Sent To  
Notes
2018-05-25 11:09:33ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-07-17 Cont ID  
Sent By tklarge Date 2018-07-17 Time 05:11 Rev Time 0.00
Received By tklarge Date 2018-07-17 Time 04:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-03 Cont ID  
Sent By tklarge Date 2018-06-03 Time 04:22 Rev Time 0.00
Received By tklarge Date 2018-06-03 Time 04:00 Sent To  
Notes
2018-06-03 04:18:191) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN
 DRAIN AND THE PUMP. WPB AMEND. TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-07-12 Cont ID  
Sent By mcruz Date 2018-07-12 Time 14:39 Rev Time 0.00
Received By mcruz Date 2018-07-12 Time 14:37 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By mcruz Date 2018-05-31 Time 09:16 Sent To B
Notes
2018-05-31 10:06:55ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) INDICATE SETBACK FROM POOL EQUIPMENT TO REAR
 PROPERTY LINE. MUST BE AT 11 FEET.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 561-822-1442
 [email protected]