| Plan Review Stops For Permit 18051199 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-15 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-19 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-22 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-22 |
Time |
14:42 |
Sent To |
I |
|
| Notes |
| 2018-06-22 14:56:01 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-15 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-19 |
Time |
11:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-08 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-08 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-06-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-02 |
Time |
06:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-02 |
Time |
05:43 |
Sent To |
|
|
| Notes |
| 2018-06-02 06:07:42 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-25 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-17 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2018-07-18 15:07:50 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-10 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-03 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2018-07-05 15:52:23 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-22 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-24 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2018-05-25 11:10:56 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-25 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-25 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2018-07-25 15:40:52 | 07/25/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | PLUMBING PLAN EXAMINER, LUIS A. CRESPO | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-10 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-10 |
Time |
11:38 |
Sent To |
I |
|
| Notes |
| 2018-07-10 13:16:00 | 1) THE TDH CALCULATIONS AND THE PUMP CURVE ARE BARELY | | | LEGIBLE ON PAGE 4. THE PUMP MODELS ARE ILLLEGIBLE. | | | SUBMIT A LEGIBLE POOL PUMP CURVE FOR REVIEW. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 2) THE CALCULATIONS SHOW A TDH OF 47.90 FT. TDH. THE | | | TDH OF THE PUMP CURVE FOR THE PUMP TO BE INSTALLED | | | APEARS TO SHOW THE PUMP CURVE STARTING AT 20 TDH.PLEASE | | | CLARIFY. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-02 |
Time |
06:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-02 |
Time |
05:43 |
Sent To |
|
|
| Notes |
| 2018-06-02 06:07:13 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER). | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN | | | DRAIN AND FOR THE PUMP. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-05-30 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-05-30 |
Time |
15:38 |
Sent To |
B |
|
| Notes |
| 2018-05-30 15:44:42 | NOTE - POOL EQUIPMENT SHALL BE AT LEAST 3.5 FEET FROM | | | SUIDE PROPERTY LINES. |
|
|