Plan Review Details - Permit 18051174
| Plan Review Stops For Permit 18051174 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2019-10-04 16:12:36 | SOIL REPORT RECEIVED AND ADDED TO RECORD FILE. 10/4/19 | | | DB | | 2018-09-12 12:56:49 | PROVISOS: | | | | | | A. ENGINEERED TRUSS DRAWINGS REQUIRED AT INSPECTION | | | B. SEPARATE PERMITS REQUIRED FOR DEMO, FENCING, WALLS | | | C. STAIR ENGINEERING IS TO BE REVIEWED BY DESIGNER OF | | | RECORD AND SUBMITTED TO BUILDING DIVISION FOR REVIEW | | | PRIOR TO INSTALLATION. | | | D. OWNER TO PROVIDE SOILS REPORT PRIOR TO FOUNDATION | | | WORK. | | | AS DISCUSSED WITH S.H AND D.B. THE OLD HOUSE NEEDS TO | | | BE DEMOED BEFORE THE SOILS REPORT CAN BE DONE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-29 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-27 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2018-06-29 10:42:11 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18051174 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 110.9] DETAIL 4-A9 WAS PROVIDED (SITE WALL). I | | | WAS UNABLE TO LOCATE PROPOSED LOCATION (C1, A1), PLEASE | | | ADVISE WHERE THIS CAN BE FOUND OR ADD TO PLAN. IF IT IS | | | NEAR THE PROPERTY LINE, SHOW LOCATION OF FOOTING | | | RELATIVE TO THE PROPERTY LINE. TYPICALLY AN ECCENTRIC | | | FOOTER IS REQUIRED FOR SITE WALL. | | | | | | IF A SITE (RETAINING) WALL IS NOT PROPOSED, REVISE C1 | | | TO SHOW PROPOSED GRADES AND GRADES ON ADJACENT PARCEL | | | TO SHOW HOW WATER WILL BE DIRECTED TO DRAIN TO STORM | | | DRAIN AT FRONT OF PROPERTY OR SWALE TO THE REAR RATHER | | | THAN ADJACENT PARCEL. | | | | | | 2.[FBC R401.3]SITE DRAINAGE TO PROVIDE 2% SLOPE FOR | | | IMPERVIOUS SURFACES WITHIN 10' OF THE FOUNDATION. | | | | | | 3.[FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING | | | CAPACITY AS REFERENCED ON SHEET S4. | | | | | | 4.[FBC 107] PROVIDE CUT SHEET FOR ICYNENE WITH THE TYPE | | | SELECTED TO ESTABLISH THICKNESS NEEDED TO MEET REQUIRED | | | R-VALUE. | | | | | | 5.[FBC R302.9.1 & R302.9.2]ADD NOTE TO SHEET A9 THAT | | | FINISHES SHALL HAVE A FLAME SPEAD INDEX OF NOT GREATER | | | THAN 200 AND SMOKE DEVELOPED INDEX OF NOT GREATER THAN | | | 400. | | | | | | 6.[FBC R506.2.3]S-1 SHOWS CORRECT VAPOR BARRIER, BUT | | | SHEET A9 SHOWS CONFLICTING NUMBERS. PLEASE ADJUST SHEET | | | A-9 TO MATCH SHEET S-1. | | | | | | 7.[FBC R506.2.4] ADD NOTE ON SHEET S1 FOR CONTRACTION | | | JOINTS TO COMPLY WITH ACI 332 OR APPROVED INDUSTRY | | | STANDARD. | | | | | | 8.[R302.6]NOTE ON A-2 CALLS OUT TYPE X DRYWALL ON | | | CEILING IN GARAGE. TO AVOID FIELD/INSPECTION ISSUES, IT | | | IS SUGGESTED TO CALL OUT TYPE X DRYWALL ON SECTION 1/A9 | | | TO MATCH. | | | | | | 9.[FBC 107.3.5.3]UPDATE SHEET S4 STRUCTURAL NOTES TO | | | REFERENCE FBC 2017 6TH EDITION IN LINE JUST BELOW CODES | | | AND STANDARDS. | | | | | | 10.[FBC 107.3.5.3]PROVIDE LINTEL SCHEDULE FOR EACH | | | WINDOW/DOOR WHERE LINTEL IS TO BE PROVIDED. THIS IS TO | | | ESTABLISH MINIMUM BEARING TO MATCH N.O.A. 17-0821.18. | | | | | | 11.[FBC R703.4]PROVIDE TYPE OF WINDOW/DOOR FLASHING TO | | | BE USED TO MEET REQUIREMNETS OF R703.4 | | | | | | 12.[FBC R302.11]ADD FIREBLOCKING TO DETAIL SHEET A9 ON | | | TYPICAL WALL SECTIONS. | | | | | | 13.[FBC R407.2]ADD NOTE THAT THAT STATES HOW STEEL | | | COLUMNS WILL MEET PRTECTION REQUIREMENTS IN R407.2 | | | | | | 14.[R302.12]UPDATE DRAFTSTOPPING NOTE ON SHEET A8 TO | | | SAY R302.12 INSTEAD OF R301.12. ALSO, COPY/PASTE THIS | | | NOTE TO SHEET S2 WHERE FLOOR TRUSSES ARE ARE SHOWN IN | | | PLAN VIEW. | | | | | | 15.[FBC R311.3 & R311.3.1]EGRESS LANDING SHALL NOT BE | | | LESS THAN 1 1/2" LOWER THAN THE TOP OF THRESHOLD.SHOW | | | DIMENSION OF LANDING IN RELATIONSHIP TO FINISHED FLOOR | | | ON SHEET A8 AND S1. | | | | | | 16.[FBC R310]PROVIDE DETAIL OF HOW DECO RAILS AT EGRESS | | | WINDOWS MEET EGRESS REQUIREMENTS. | | | | | | 17.[FBC 107.2.1]PROVIDE NOTICE OF ACCEPTANCE(N.O.A) | | | THAT IS NOT EXPIRED FOR N.O.A. 17-1212.2A AND N.O.A. | | | 17-1212.09. | | | | | | 18. [FBC 107, FBC R 301] THE SHINGLE PRODUCT APPROVAL | | | IS OK | | | FOR THE FLAT DECK, THE ASSEMBLY PROPOSED AND | | | ENGINEERING FOR ZONES 2 & 3, IF APPLICABLE, IS | | | REQUIRED. | | | | | | ALTERNATIVELY, THIS MAY BE PROVIDED AT TIME OF ROOF SUB | | | PERMIT APPLICATION UPON REQUEST. | | | | | | 19. [FBC 109], A VALUATION ADJUSTMENT HAS BEEN DONE PER | | | ICC TABLES: | | | $945,112.55 UNDER AIR (7979 SQ. FT. X 118.45) | | | $80,065.00 UNDER ROOF (1675 SQ. FT. X 47.80) | | | 1,025,177.50 TOTAL EVALUATION | | | | | | 20. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING | | | PROVISOS: | | | | | | A. ENGINEERED TRUSS DRAWINGS REQUIRED AT INSPECTION | | | B. SEPARATE PERMITS REQUIRED FOR DEMO, FENCING, WALLS | | | SITE WALLS AND POOL. | | | C. STAIR ENGINEERING IS TO BE REVIEWED BY DESIGNER OF | | | RECORD AND SUBMITTED TO BUILDING DIVISION FOR REVIEW | | | PRIOR TO INSTALLATION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-16 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-16 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-30 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-30 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2018-08-30 09:08:52 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. RISER SHOWS A METER CAN FEEDING A MLO PANEL (PANEL | | | A) AND THE GENERATOR TRANSFER SWITCH (MUST BE SERVICE | | | RATED. FIRST FLOOR PLAN SHOWS A METER WITH A MAIN | | | DISCONNECT ON CORNER OF GARAGE WITH THE PANELS AND | | | TRANSFER SWITCH INSIDE. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. NEC 215.5; WPB FBC 107.2.1 (PLAN SHOWS A | | | METER CAN WITH A CT CAN, WHICH IS NOT TYPICAL IN A | | | RESIDENTIAL INSTALLATION. PERHAPS THIS IS A TRANSFER | | | SWITCH, SINCE IT SHOWS A CONDUIT FROM THE GENERATOR? | | | THE GENERATOR WOULD NOT TIE IN TO A CT CAN. FURTHER | | | CLARIFICATION AND/OR CORRECTION NEEDED FOR RISER. FROM | | | METER CAN TO FIRST MEANS OF DISCONNECT, THERE WOULD NOT | | | BE AN EQUIPMENT GROUNDING CONDUCTOR (EGC). AFTER THE | | | FIRST MEANS, THERE SHOULD BE AN EGC IN EACH CONDUIT.) | | | 6. IF METER FEEDS DIRECTLY TO PANEL A, THIS PANEL IS | | | REQUIRED TO HAVE A MAIN BREAKER. PROVIDE CORRECTION. | | | PROVIDE INDICATION THAT TRANSFER SWITCH IS SERVICE | | | RATED. NEC 110.3, 230.70; FBC RE E3601.6 (COMMENT IS | | | RELATED TO COMMENT 5, WITH FURTHER CORRECTION THIS WILL | | | PROBABLY BE ADDRESSED.) | | | 7. CORRECTED. | | | 8.CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED. | | | 12. WITH THE EXCEPTION OF THE CABANA BATH, PLAN DOES | | | NOT SHOW THE 20 AMP CIRCUIT REQUIRED FOR BATHROOM | | | RECEPTACLE OUTLETS. A MINIMUM OF ONE 20 AMPERE BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. | | | PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | | (POSSIBLY CIRCUITS 18 AND 20 IN PANEL A?, BUT THIS IS | | | NOT SHOWN AS BATHROOM GFCI.) | | | 13. CLOSET LIGHTS ARE SHOWS AS STANDARD RECESS LIGHTS | | | OR A CHANDELIER J-BOX. PER CODE: LIGHTING WITH OPEN OR | | | PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES OR | | | LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 (THESE | | | LIGHTS ARE STILL SHOWN AS STANDARD RECESS LIGHTS, AND | | | SOME ARE SHOWN DIRECTLY OVER THE STORAGE SPACE, WHICH | | | IS A VIOLATION FOR MOST TYPES OF LIGHTS. CORRECTION IS | | | NEEDED.) | | | 14. CORRECTED. | | | 15. CORRECTED. | | | 16. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET | | | OF EACH ROOM USED FOR SLEEPING PURPOSES. PROVIDE SMOKE | | | ALARM ON EACH STORY OF THE DWELLING. SMOKE ALARMS MUST | | | BE INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1; NFPA 72:29.8.3.4 (SYMBOL USED IS NOT IN LEGEND | | | AND APPEARS TO BE A SMOKE ALARM ONLY, AS IT DOES NOT | | | HAVE AN "SD" INSIDE THE SYMBOL. A CARBON MONOXIDE ALARM | | | IS REQUIRED WITHIN 10 FEET OF EACH ROOM USED FOR | | | SLEEPING PURPOSES. PROVIDE CORRECTION.) | | | 17. PROVIDE GFCI PROTECTED RECEPTACLE ON BALCONIES. NEC | | | 210.52(E); FBC RE E3901.7 (BALCONIES THAT CAN BE | | | ACCESSED FROM THE INTERIOR OF THE HOME, EVEN IF YOU | | | CAN'T WALK OUT ONTO THE BALCONY, MUST HAVE A RECEPTACLE | | | OUTLET. THE WEST ELEVATION IS MISSING THIS. PROVIDE | | | CORRECTION.) | | | 18. CORRECTED. | | | 19. CORRECTED. | | | 20. CORRECTED. | | | 21. CORRECTED. | | | 22. CORRECTED. | | | 23. PROVIDE AIC RATING OF SERVICE DISCONNECT, TRANSFER | | | SWITCH, AND PANELS. NEC 110.3, 110.9 (NOT SHOWN ON | | | PANEL SCHEDULES, MUST BE RATED TO MEET OR EXCEED AIC | | | CALCULATION PROVIDED.) | | | 24. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 25. NOW THAT THE ROOMS ARE IDENTIFIED ON THE PLAN, I | | | SEE THERE IS A STORAGE AREA (ROOM 103) AND A WORKSHOP | | | (ROOM 119). THESE AREAS SHOULD HAVE GFCI PROTECTED | | | OUTLETS. NEC 210.8(A)(2); FBC RE E3902.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-29 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-08-29 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-08-29 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2018-08-29 09:01:25 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. LOAD CALCULATION SHOWS 40,434 WATTS HVAC LOAD, BUT | | | THE PANEL SCHEDULES ONLY SHOW THREE SYSTEMS. PROVIDE | | | CLARIFICATION AND/OR CORRECTION. NEC 215.5, 220; FBC RE | | | E3602.2; WPB FBC 107.2.1 | | | 5. RISER SHOWS A METER CAN FEEDING A MLO PANEL (PANEL | | | A) AND THE GENERATOR TRANSFER SWITCH (MUST BE SERVICE | | | RATED. FIRST FLOOR PLAN SHOWS A METER WITH A MAIN | | | DISCONNECT ON CORNER OF GARAGE WITH THE PANELS AND | | | TRANSFER SWITCH INSIDE. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. NEC 215.5; WPB FBC 107.2.1 | | | 6. IF METER FEEDS DIRECTLY TO PANEL A, THIS PANEL IS | | | REQUIRED TO HAVE A MAIN BREAKER. PROVIDE CORRECTION. | | | PROVIDE INDICATION THAT TRANSFER SWITCH IS SERVICE | | | RATED. NEC 110.3, 230.70; FBC RE E3601.6 | | | 7. SERVICE CONDUCTORS FROM METER CAN TO PANELS IS SHOWN | | | AS # 2/0 WIRE TO A 200 AMP PANEL. WIRE SIZES FROM NEC | | | 310.15(B)(7), OR FBC RE E3603.1, CAN ONLY BE USED WHEN | | | THE SERVICE CONDUCTOR SUPPLIES 100% OF THE LOAD. SINCE | | | THIS IS NOT THE CASE, PROVIDE CORRECTED WIRE SIZE FROM | | | METER CAN TO PANELS, RATED FOR THE 200 AMPS SPECIFIED. | | | NEC 310.15(B)(7) AND (B)(16); FBC RE E3603.1, E3705.1 | | | 8. PLAN SHOWS AHU?S BEING FED WITH #6 WIRE ON A 60 AMP | | | BREAKER. #6 ROMEX WIRE, WHICH IS TYPICAL IN RESIDENTIAL | | | WIRING, IS NOT RATED FOR 60 AMPS. PROVIDE CORRECTION. | | | NEC 334.80; FBC RE E3705.4.4 | | | 9. OK | | | 10. OK | | | 11. PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC | | | 210.8(D); FBC RE E3902.10 | | | 12. WITH THE EXCEPTION OF THE CABANA BATH, PLAN DOES | | | NOT SHOW THE 20 AMP CIRCUIT REQUIRED FOR BATHROOM | | | RECEPTACLE OUTLETS. A MINIMUM OF ONE 20 AMPERE BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. | | | PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | | 13. CLOSET LIGHTS ARE SHOWS AS STANDARD RECESS LIGHTS | | | OR A CHANDELIER J-BOX. PER CODE: LIGHTING WITH OPEN OR | | | PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES OR | | | LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 14. OK | | | 15. OK | | | 16. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET | | | OF EACH ROOM USED FOR SLEEPING PURPOSES. PROVIDE SMOKE | | | ALARM ON EACH STORY OF THE DWELLING. SMOKE ALARMS MUST | | | BE INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1; NFPA 72:29.8.3.4 | | | 17. PROVIDE GFCI PROTECTED RECEPTACLE ON BALCONIES. NEC | | | 210.52(E); FBC RE E3901.7 | | | 18. OK | | | 19. OK | | | 20. OK | | | 21. OK | | | 22. OK | | | 23. OK | | | 24. OK | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-19 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-18 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2018-06-19 18:14:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE NEC SPECIFIED FOR DESIGN ON SHEET A1 DOES NOT | | | EXIST. PROVIDE CORRECTION. FBC PREFACE (ALSO SEE | | | CURRENT CODES ABOVE) | | | 2. THE LOAD CALCULATION FOR THE WHOLE HOUSE SHOWS A | | | LOAD OF 4200 WATTS FOR FOUR SMALL APPLIANCE CIRCUITS. A | | | MINIMUM OF 1500 WATTS OR EACH SMALL APPLIANCE CIRCUIT | | | MUST BE INCLUDED. PROVIDE CORRECTION. NEC 220.52; FBC | | | RE E3602.2 | | | 3. WHOLE HOUSE LOAD CALCULATION SHOWS A LOAD FOR | | | ELECTRIC RANGE AS 1500 WATTS. AN ELECTRIC RANGE MUST BE | | | CALCULATED AT A MINIMUM OF 8000 WATTS AND HAVE A BRANCH | | | CIRCUIT WITH A MINIMUM RATING OF 40 AMPERES. PROVIDE | | | CORRECTION. NEC 210.21(B)(4); FBC RE E3702.9 | | | 4. LOAD CALCULATION SHOWS 40,434 WATTS HVAC LOAD, BUT | | | THE PANEL SCHEDULES ONLY SHOW THREE SYSTEMS. PROVIDE | | | CLARIFICATION AND/OR CORRECTION. NEC 215.5, 220; FBC RE | | | E3602.2; WPB FBC 107.2.1 | | | 5. RISER SHOWS A METER CAN FEEDING A MLO PANEL (PANEL | | | A) AND THE GENERATOR TRANSFER SWITCH (MUST BE SERVICE | | | RATED. FIRST FLOOR PLAN SHOWS A METER WITH A MAIN | | | DISCONNECT ON CORNER OF GARAGE WITH THE PANELS AND | | | TRANSFER SWITCH INSIDE. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. NEC 215.5; WPB FBC 107.2.1 | | | 6. IF METER FEEDS DIRECTLY TO PANEL A, THIS PANEL IS | | | REQUIRED TO HAVE A MAIN BREAKER. PROVIDE CORRECTION. | | | PROVIDE INDICATION THAT TRANSFER SWITCH IS SERVICE | | | RATED. NEC 110.3, 230.70; FBC RE E3601.6 | | | 7. SERVICE CONDUCTORS FROM METER CAN TO PANELS IS SHOWN | | | AS # 2/0 WIRE TO A 200 AMP PANEL. WIRE SIZES FROM NEC | | | 310.15(B)(7), OR FBC RE E3603.1, CAN ONLY BE USED WHEN | | | THE SERVICE CONDUCTOR SUPPLIES 100% OF THE LOAD. SINCE | | | THIS IS NOT THE CASE, PROVIDE CORRECTED WIRE SIZE FROM | | | METER CAN TO PANELS, RATED FOR THE 200 AMPS SPECIFIED. | | | NEC 310.15(B)(7) AND (B)(16); FBC RE E3603.1, E3705.1 | | | 8. PLAN SHOWS AHU?S BEING FED WITH #6 WIRE ON A 60 AMP | | | BREAKER. #6 ROMEX WIRE, WHICH IS TYPICAL IN RESIDENTIAL | | | WIRING, IS NOT RATED FOR 60 AMPS. PROVIDE CORRECTION. | | | NEC 334.80; FBC RE E3705.4.4 | | | 9. BREAKER FOR POOL PUMP AND JACUZZI TUB REQUIRED TO BE | | | GFCI PROTECTED. PROVIDE CORRECTION. NEC 680.21(C), | | | 680.43(A)(3), 680.71; FBC RE E4203.1.3, E4209.1 | | | 10. BE ADVISED THAT THE GENERATOR AND SWIMMING POOL ARE | | | NOT INCLUDED IN THE SCOPE OF THIS PLAN REVIEW. PROVIDE | | | A BLOCK NOTE INDICATING THE REQUIRED SEPARATE PERMITS | | | AND PLAN SUBMITTALS FOR THESE SYSTEMS. WPB FBC 105.1, | | | 107.2.1 | | | 11. PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC | | | 210.8(D); FBC RE E3902.10 | | | 12. WITH THE EXCEPTION OF THE CABANA BATH, PLAN DOES | | | NOT SHOW THE 20 AMP CIRCUIT REQUIRED FOR BATHROOM | | | RECEPTACLE OUTLETS. A MINIMUM OF ONE 20 AMPERE BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. | | | PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | | 13. CLOSET LIGHTS ARE SHOWS AS STANDARD RECESS LIGHTS | | | OR A CHANDELIER J-BOX. PER CODE: LIGHTING WITH OPEN OR | | | PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES OR | | | LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 14. SOME LIGHTING OVER BATHTUBS OR SHOWERS ARE SHOWS AS | | | STANDARD LIGHTS OR A CHANDELIER J-BOX. NO PARTS OF | | | CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, OR | | | CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK, PENDANTS, OR | | | CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED WITHIN | | | A ZONE MEASURED 3 FEET HORIZONTALLY AND 8 FEET | | | VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER | | | STALL THRESHOLD. LIGHTING IN BATHTUB OR SHOWER AREAS | | | SHALL BE SUITABLE FOR DAMP LOCATIONS. PROVIDE | | | CORRECTION. NEC 410.10(D); FBC RE E4003.11 | | | 15. IDENTIFY ROOMS ON ELECTRICAL PLAN. WPB FBC 107.2.1 | | | 16. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET | | | OF EACH ROOM USED FOR SLEEPING PURPOSES. PROVIDE SMOKE | | | ALARM ON EACH STORY OF THE DWELLING. SMOKE ALARMS MUST | | | BE INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1; NFPA 72:29.8.3.4 | | | 17. PROVIDE GFCI PROTECTED RECEPTACLE ON BALCONIES. NEC | | | 210.52(E); FBC RE E3901.7 | | | 18. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE. PROVIDE CORRECTION. NEC 210.8; FBC | | | RE E3902.2 | | | 19. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | 20. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 21. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 22. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | EACH PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 23. PROVIDE AIC RATING OF SERVICE DISCONNECT, TRANSFER | | | SWITCH, AND PANELS. NEC 110.3, 110.9 | | | 24. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-06-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-21 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-21 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2018-06-21 07:54:45 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC. | | | G2413.4.1, G2413.4.2. | | | | | | 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING | | | | | | (IF APPLICABLE) FOR EACH PIPE SIZE. WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 3. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 4. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 FBC-RES. | | | SEC. G 2413.4.1, G2413.4.2. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 OR 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE OF VENT, LOCATION, | | | SIZE, TERMINATION POINT, HEIGHT ABOVE THE ROOF AND | | | ANCHORING DETAILS OF THE GAS VENT(S) PER 2017 FBC-FUEL | | | GAS SECS. 502 THRU 505 OR 2017 FBC-RES. SEC.G2426 | | | THROUGH G2439. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAPACITY OF LP | | | TANK(S), TYPE OF TANK (DOT OR ASME), THE DISTANCE OF | | | THE TANK FROM THE EXTERIOR BUILDING WALL AND ADJACENT | | | PROPERTY LINES, THE DISTANCE OF THE TANK FROM ALL | | | SOURCES OF IGNITION, OTHER CONTAINERS, BUILDINGS, AND | | | THE LOCATION OF ANY BUILDING OPENINGS BELOW THE RELIEF | | | VALVE OF THE TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE LP TANK IS | | | ABOVE GROUND OR BELOW GROUND, AND SHOW THE METHOD OF | | | REQUIRED PROTECTION FOR THE LP TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK IS BELOW GROUND IT SHALL BE | | | ANCHORED PER NFPA 58 SEC.3-2.2.7 (H). IF ABOVE GROUND, | | | THE TANK SHALL BE SECURELY ANCHORED TO WITHSTAND 170 | | | MPH ULT WIND LOAD PER THE FLORIDA BUILDING CODE. | | | | | | 12. EMERGENCY HOOD SHUT DOWN SHUT OFF VALVE SHALL BE | | | BELOW THE CEILING. THE MANUAL SHUTOFF VALVE SHALL BE | | | UPSTREAM. UNION TO BE DOWN STREAM OF MANUAL VALVE. | | | SECS. 10.4, 10.5 OF NFPA 96-08. | | | | | | 13. INDICATE ON THE PLAN IF THE TANKLESS WATER HEATER | | | IS THE ONLY GAS APPLIANCE ON THIS SYSTEM? IF NOT, | | | SUBMIT A COMPLETE GAS RISER SHOWING ALL PIPE SIZES, | | | TYPE OF PIPE, THE DEVELOPED LENGTH TO THE FURTHEST GAS | | | OUTLET, THE BTU LOAD OF EACH APPLIANCE, THE PSI OF THE | | | SYSTEM, THE TYPE OF GAS AND THE TOTAL BTU LOAD ON THE | | | SYSTEM. THESE REQUIREMENTS ALSO APPLY TO A NEW GAS | | | SYSTEM. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-16 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-16 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2018-10-12 15:35:08 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-09-21 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-08-10 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-29 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-24 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2018-09-12 13:04:12 | CUSTOMER SPOKE TO S.H. AND D.B. ABOUT THE COMMENTS AND | | | PLAM BEACH COUNTY HAD NO ADDITIONAL FEES DUE TO | | | EXISTING SQ. FOOTAGE EXCEEDING PROPOSED. | | | PLANS ARE STAMPED FROM PBC. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-29 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-22 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2018-06-29 07:44:30 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES DUE, IF APPLICABLE, PROVIDED. | | | | | | AFTER ALL OTHER REVIEWS HAVE PASSED, CHECK OUT ONE SET | | | OF PLANS TO TAKE TO THE COUNTY. | | | | | | 561-233-5025 FOR MORE INFORMATION | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-20 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-09-20 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-09-20 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-06-13 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-06-12 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2018-06-13 09:10:56 | PLAN DENIED | | | 1) REFER TO SECTION R 403.3.6 AIR HANDLING UNITS | | | 2017 FLORIDA ENERGY CODE. | | | 2) REFER TO SECTION M 1503.4 MAKE UP AIR. PROVIDE | | | MANUFACTURES SPECIFICATIONS ON KITCHEN HOOD. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | HMOSER @ WPB.ORG | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-16 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-16 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2018-10-16 16:08:44 | 3RD REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: APPROVED | | | | | | PROVISO | | | | | | 1. RE: PLAN SHEET P3; SANITARY ISOMETRIC | | | A. KITCHEN 224 SINK: PROVIDE AIR ADMITTANCE VALVE | | | CONNECTING ABOVE THE TRAP WEIR OF THE FIXTURE PER FBC | | | RES SECTION P3114. | | | B. RED LINED ON THE PLAN TO CLARIFY. | | | 2. RE: PLAN SHEET P3; PLUMBING NOTES | | | A. NOTE 11 REGARDING AC CONDENSATE SYSTEM(S); SEE M.2 | | | MECHANICAL PLAN FOR SIZE AND ROUTING. INSULATE IN | | | INTERIOR SPACES. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-11 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-11 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2018-09-11 12:31:32 | 2ND REVIEW: FBC 2017 6TH EDITION | | | PERMIT 18051174 | | | PLUMBING COMMENTS: | | | | | | 1. RE: PLAN SHEET P3; | | | A. SHOW TRAP ON ALL UNDERFLOOR FIXTURE DRAINS, IE. | | | BATHTUBS AND SHOWERS, UNLESS FIXTURE IS INTEGRALLY | | | TRAPPED, IE. WATER CLOSETS. FBC WPB AMEND 107.2.1, FBC | | | RES P3201.2 | | | B. OVAL SYMBOLS AT END OF HORIZONTAL PIPING FOR WATER | | | CLOSETS AND DISHWASHERS ARE CONFUSING. PROVIDE VERTICAL | | | EXTENSION AT END OF WATER CLOSET HORIZONTAL AND PLACE | | | OVAL SYMBOL AT TOP PER FBC WPB AMEND 107.2.1. | | | DISHWASHER IS TO CONNECT TO SINK TAILPIECE ABOVE TRAP, | | | NOT DOWNSTREAM OF TRAP PER FBC RES P2717.2 | | | C. IDENTIFY ALL FIXTURES ON SANITARY ISOMETRIC. | | | D. SIZE ALL VENTS, FIXTURE DRAINS, FIXTURE BRANCHES, | | | STACKS, BUILDING DRAIN AND BRANCHES OF THE BUILDING | | | DRAIN. FBC WPB AMEND 107.2.1 | | | 2. RE: PLAN SHEET P3; PLUMBING NOTES | | | A. NOTE 1; CHANGE THE WORDS "ALL APPLICABLE CODES" TO | | | "THE 2017 FBC RESIDENTIAL CODE AND CITY OF WEST PALM | | | BEACH AMENDMENTS TO 2017 FBC". FBC WPB AMEND 107.2.1 | | | B. NOTE 11 REQUIRES PLUMBING CONTRACTOR TO PROVIDE | | | COMPLETE CONDENSATION SYSTEM. PROVIDE PIPING LAYOUT ON | | | FLOOR PLAN AND PIPING RISER DIAGRAM TO INCLUDE SIZING | | | AND DISPOSITION OF CLEAR WASTE. PROVIDE TRAP DETAIL AND | | | TERMINAL DETAIL, IE. DRYWELL. PROVIDE SPEC FOR | | | INSULATION IN THE INDOOR SPACES. FBC WPB AMEND 107.2.1 | | | C. NOTE 14: THE USE OF AIR CHAMBERS IS NOT AN | | | ACCEPTABLE METHOD FOR PREVENTION OF WATER HAMMER; | | | PROVIDE WATER HAMMER ARRESTORS IN ACCORDANCE WITH | | | MANUFACTURER'S INSTRUCTIONS. FBC RES P903.5 | | | D. ADD NOTE: SHOWER CONTROL VALVE(S) SHALL BE PRESSURE | | | BALANCED PB,THERMOSTATIC MIXING (TM) OR COMBINATION | | | PB/TM VALVE TYPES WITH HIGH TEMPERATURE LIMITING STOP. | | | 2017 FBC RES 2708.4 | | | E. ADD NOTE: AN ACCESSIBLE TEMPERATURE LIMITING DEVICE | | | REQUIRED ON HOT WATER TO BATHTUB VALVE(S) IS REQUIRED. | | | 2017 FBC RES 2713.3 | | | 3. GROUND FLOOR WASHING MACHINE | | | A. P3 SANITARY ISOMETRIC: PROVIDE AAV OR AN INDIVIDUAL | | | VENT WASHING MACHINE FIXTURE DRAIN WHICH MAY REVENT TO | | | HALF BATH VENT STACK ABOVE FLOOD LEVEL RIM OF THE | | | FIXTURES. FBC RES P3101.2.1 | | | B. P1 FLOOR PLAN: THE WASHING MACHINE ON THE FIRST | | | FLOOR SHALL CONNECT DOWN STREAM OF THE HALF BATHROOM | | | GROUP. PER FBC RES P3108.1. COORDINATE WITH SANITARY | | | ISOMETRIC ON P3. | | | 4. BATH(S)209/210: | | | A. P3 SANITARY ISOMETRIC; URINAL IS A WALL DISCHARGE | | | FIXTURE. IT CANNOT CONNECT HORIZONTALLY TO HORIZONTAL | | | FIXTURE BRANCH. PROVIDE AAV OR AN INDIVIDUAL VENT ABOVE | | | VERTICAL WASTE PIPE WHICH MAY REVENT TO BATH VENT STACK | | | ABOVE FLOOD LEVEL RIM OF THE FIXTURES. FBC RES | | | P3101.2.1 | | | B. P1 SECOND FLOOR PLAN IS CONFUSING. HORIZONTAL | | | DRAINAGE BRANCH TO 210 BT AND SHOWER IS NOT SHOWN; | | | HORIZONTAL PIPING FOR 209/210 DOES NOT MATCH ISOMETRIC | | | ON P3. FBC WPB AMEND 107.2.1 | | | 5. BATH 228 | | | A. P3: A FIXTURE IS MISSING ON SANITARY ISOMETRIC. | | | PLEASE CLARIFY. FBC WPB AMEND 107.2.1 | | | B. P1: BATHTUB AND WATER CLOSET FIXTURE DRAINS SHOWN | | | CONNECTING TO EACH OTHER BEFORE CONNECTING TO(WET)VENT. | | | MUST CONNECT INDEPENDENTLY TO VENT FBC RES 3108.1; | | | FIXTURE DRAIN LENGTH TRAP TO VENT TO BE IN ACCORDANCE | | | WITH FBC RES TABLE P3105.1. | | | C. P1 PLAN VIEW PIPING AND P3 SANITARY ISOMETRIC DO NOT | | | MATCH. PLEASE CLARIFY. | | | 6. LAUNDRY RM 202: P1 SECOND FLOOR PLAN IS CONFUSING. | | | HORIZONTAL FIXTURE DRAIN FROM WASHING MACHINE SOIL | | | STACK TO IS NOT SHOWN; DOES NOT MATCH ISOMETRIC ON P3. | | | PLEASE CLARIFY. FBC WPB AMEND 107.2.1 | | | 7. CABANA BATH 123: P1 AND P3; HORIZONTAL FIXTURE DRAIN | | | FROM OUTDOOR KITCHEN SINK MUST CONNECT DOWNSTREAM FROM | | | CABANA BATH WET VENT, NOT AT THE JUNCTION. FBC RES | | | P3108.1 | | | 8. HER BATH 217: P1 PLAN VIEW PIPING AND P3 SANITARY | | | ISOMETRIC DO NOT MATCH. HORIZONTAL PIPING FROM LAV AND | | | SHOWER TO SOIL STACK NOT SHOWN ON P1. PLEASE CLARIFY; | | | NOTE THAT PIPING IN ACCORDANCE WITH THE DRAINAGE FLOW | | | SHOWN ON P3 MEETS THE REQUIREMENTS OF | | | P3108.1(HORIZONTAL WET VENTING)WITHOUT THE NEED OF THE | | | INDIVIDUAL VENTS SHOWN AT THE WATER CLOSET AND BATHTUB. | | | 9. HALF BATH RM 120/WORKSHOP 119 SINK: WORKSHOP SINK TO | | | CONNECT DOWNSTREAM OF HALF BATH. FBC RES P3108.1. SHOW | | | ON P1 AND P3. FBC WPB AMEND 107.2.1 | | | 10. KITCHEN 224 SINK: NOTE LOCATION OF WASTE STACK FROM | | | BELOW AND SHOW ANY UNDERFLOOR HORIZONTAL PIPING | | | REQUIRED ON SECOND FLOOR PLAN P1. P1 AND P3 TO MATCH. | | | FBC WPB AMEND 107.2.1 | | | P1 PLAN VIEW PIPING AND P3 SANITARY ISOMETRIC DO NOT | | | MATCH. PLEASE CLARIFY. | | | 11. RE; P2 WATER DISTRIBUTION PLAN. SHOW BRANCH PIPING | | | IN 1ST FLOOR CEILING TO RISERS TO SECOND FLOOR. PLEASE | | | SIZE ALL RUNOUTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-20 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-20 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2018-06-20 17:11:39 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. E3 THE WASHING MACHINE ON THE FIRST FLOOR SHALL | | | CONNECT DOWN STREAM OF THE HALF BATHROOM GROUP. PER FBC | | | RES P3108.4 | | | | | | 2. THE KITCHEN SINK IN ROOM 115 SHALL BE VENTED BY AN | | | AAV OR THE VENT SHALL RUN UP TO SECOND FLOOR ABOVE | | | FLOOD LEVEL RIM OF THE FIXTURES BEFORE REVENTING INTO | | | THE VENT STACK. PER FBC RES P3101.2.1 | | | | | | 3. THE HALF BATHROOM #120 SHALL BE VENTED SEPARATELY | | | FROM THE UPSTAIRS KITCHEN AND CONNECT TO THE HORIZONTAL | | | BUILDING DRAIN NOT THE SOIL STACK. PER FBC RES | | | P3101.2.1 , P3108.4 | | | | | | 4. THE SINK IN THE WORK SHOP SHALL CONNECT TO THE | | | BUILDING DRAIN DOWN STREAM OF THE HALF BATHROOM. | | | P3108.4 | | | | | | 5. PLEASE PROVIDE PLUMBING FLOOR PLAN INCLUDING WATER | | | AND SANITARY TO DETERMINE CODE COMPLIANCE OF PLUMBING | | | SYSTEM DESIGN. PER WPB AMEND TO FBC 107.2.1 | | | | | | 6. UNDER WORK DESCRIPTION ON PERMIT APPLICATION IT | | | STATES A 14X 35 FIBERGLASS POOL PROVIDE PLANS OR REMOVE | | | FROM WORK DESCRIPTION. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2018-09-12 12:59:17 | PRODUCT APPROVALS WERE SUBMITTED AND APPROVED. | | | THE ROOFING SUB CONTRACTOR WILL SUPPLY ENGINEERING FOR | | | ROOF ZONES AND MODIFIED NAILING AS NEEDED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-29 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-22 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2018-06-29 07:43:54 | SEE BUILDING REVIEW | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-08-21 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-21 |
Time |
16:43 |
Sent To |
PC |
|
| Notes |
| 2018-08-21 16:43:36 | PASSED WITH PROVISOS: OVERHANG SHALL NOT ENCROACH MORE | | | THAN 3' INTO A SETBACK. A/C PAD SHALL BE AT LEAST 6' | | | FRONT SIDE PROPERTY LINE. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2018-06-14 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-06-14 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2018-06-14 16:16:47 | PASSED WITH PROVISOS: OVERHANG SHALL NOT ENCROACH MORE | | | THAN 3' INTO A SETBACK. A/C PAD SHLL BE AT LEAST 6' | | | FROMT SIDE PROPERTY LINE. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
|