| Plan Review Stops For Permit 18051099 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-26 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-26 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-09 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-09 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-05 |
Time |
06:23 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-10-05 |
Time |
06:08 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-24 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-06-24 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-06-24 |
Time |
07:41 |
Sent To |
B |
|
| Notes |
| 2018-06-24 07:46:18 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER PLAN PROVIDED IS | | | INSUFFICIENT. FS 471.003(2)(H); 471.025; WPB FBC | | | 107.2.1, 107.3.5 | | | CONDUIT SIZE FROM BUILDING TO SIGN MONUMENT? WIRE SIZE? | | | OVERCURRENT PROTECTION? PANEL THAT FEEDS SIGN? | | | | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-06-05 |
Time |
06:03 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-06-05 |
Time |
05:59 |
Sent To |
B |
|
| Notes |
| 2018-06-05 06:02:44 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO ELECTRICAL PLAN SUBMITTED FOR REVIEW. PROVIDE | | | ELECTRICAL PLAN FOR REVIEW, SIGNED AND SEALED BY A | | | LICENSED DESIGN PROFESSIONAL OR THE ELECTRICAL | | | CONTRACTOR QUALIFIER. FS 471.003(2)(H); 471.025; WPB | | | FBC 107.2.1, 107.3.5 | | | | | | 2. THESE ARE PRINTED COPIES OF DIGITALLY SIGNED PLANS. | | | PRINTED COPIES OF DIGITALLY SIGNED PLANS ARE NOT | | | CONSIDERED SIGNED AND SEALED. SUBMIT ELECTRICAL PLAN | | | DIGITALLY IF DIGITALLY SIGNED OR SUBMIT PAPER PLANS | | | SIGNED AND SEALED. ELECTRICAL PLAN IS REQUIRED TO BE | | | DESIGNED AND SIGNED/SEALED BY A DESIGN PROFESSIONAL OR | | | THE ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE | | | CORRECTION. FS 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-05 |
Time |
06:23 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-09-27 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2018-09-28 15:16:10 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-06-26 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-06-13 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2018-06-14 10:48:11 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-09 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-23 |
Time |
13:17 |
Sent To |
I |
|
| Notes |
| 2018-05-24 13:18:09 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-03 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-03 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-06-19 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-05-30 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-05-30 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2018-05-30 10:51:28 | ZONING REVIEW **FAILED** | | | | | | 1) IS THIS SIGN REPLAOING EXISTING LOW FREE STANDING | | | SIGN FOR THE LORD'S PACE? THE CODE ALLOW ONE FREE | | | STANDING SIGN PER BUSINESS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] | | | |
|
|