| Plan Review Stops For Permit 18050987 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-20 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-20 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-22 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-22 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-01-02 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-01-02 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2018-09-02 13:09:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. SEE PLUMBING COMMENTS. | | | | | | 2. FBC A 904, PROVIDE A DETAIL FOR THE SALES COUNTER. | | | | | | OLD SHEETS APPEAR TO HAVE BEEN REMOVED. LOCATION OF | | | SALES COUNTER NOT CLEAR, SO APPROACH CANNOT BE | | | VERIFIED. THE DETAIL PROVIDED LACKS DIMENSION TO SHOW | | | TOE AND KNEE CLEARANCE. SEE REQUIREMENTS FOR CHECK | | | WRITING SURFACES AND SALES COUNTERS, FBC A 904, 306. | | | | | | NEW COMMENT: | | | | | | 3. FBC 107, RETURN OLD SETS WHICH WERE REMOVED. DO NOT | | | REMOVE PLANS FROM THE DEPARTMENT. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-15 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2018-06-16 13:41:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. SEE PLUMBING ACCESSIBILITY COMMENTS WHICH ARE | | | APPLICABLE FOR BUILDING REVIEW, FBC ACCESIBILITY. | | | | | | 2. FBC A 904, PROVIDE A DETAIL FOR THE SALES COUNTER. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-21 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-21 |
Time |
07:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-15 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-15 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2018-06-15 10:17:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT ON ROOF PER | | | CODE. NEC 210.63 | | | 2. PROVIDE SHOW WINDOW OUTLETS PER NEC 210.62 | | | 3. PANEL SCHEDULE SHOWS A 120/208 SERVICE AND SERVICE | | | CALCULATION IS FOR 3 PHASE. RISER DIAGRAM SHOWS WIRING | | | FOR A SINGLE PHASE SERVICE. PROVIDE CLARIFICATION AND | | | CORRECTIONS AS NEEDED. NEC 215.5; WPB FBC 107.2.1 | | | 4. NOTE UNDER PANEL SCHEDULE STATES THAT ALL 15 AND 20 | | | AMP BREAKERS SHALL BE AFCI PROTECTED, WHICH IS NOT A | | | CODE REQUIREMENT FOR THIS INSTALLATION. PLEASE CLARIFY | | | AND/OR CORRECT. WPB FBC 107.2.1 | | | 5. SOME LIGHTING IS SHOWN WITHOUT THE AUTOMATIC CONTROL | | | REQUIRED. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING | | | CONTROLS STIPULATED IN THE FBC ENERGY CODE. FBC EC | | | C405.2 | | | 6. PLUMBING COMMENTS STATE THAT A WATER FOUNTAIN IS | | | REQUIRED. PROVIDE GFCI PROTECTION FOR DRINKING | | | FOUNTAIN. THE GFCI DEVICE MUST BE READILY ACCESSIBLE. | | | NEC 422.5, 422.52 | | | 7. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 8. PLAN SHOWS 2 DIFFERENT LOAD CALCULATIONS, ONE IN A | | | BLOCK NOTE AND ONE IN PANEL SCHEDULE. PROVIDE ACCURATE | | | LOAD CALCULATION INCLUDING ALL LOADS. WATER HEATER IS A | | | CONTINUOUS LOAD. NEC 220, 422.13 | | | 9. PROVIDE LIGHT FIXTURE SCHEDULE. PROVIDE CHART OF | | | INTERIOR LIGHTING POWER ALLOWANCES EXPRESSED IN WATTAGE | | | PER THE FBC ENERGY CODE IN RELATION TO THE WATTAGE OF | | | THE CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH | | | CODE. FBC EC C405.4.2; WPB FBC 107.2.1 | | | 10. SIGN CONTROLLER IS REQUIRED TO HAVE A DISCONNECT | | | WITHIN SIGHT OF THE CONTROLLER. PROVIDE CORRECTION. NEC | | | 600.6(A)(3) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-08 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2019-03-08 10:02:18 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF | | | THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE | | | INCLUDING THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND | | | ALL OTHER APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE ENSURE COMPLIANCE | | | | | | | | | | | | 2) THIS APPROVAL IS FOR THE BUILDING REMODEL ONLY. THE | | | PROPOSED NEW GAS PUMPS AND PROPOSED NEW CANOPY SHALL BE | | | UNDER SEPARATE PERMITS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-08-08 |
Time |
12:15 |
Sent To |
I |
|
| Notes |
| 2018-08-09 15:44:57 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF | | | THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE | | | INCLUDING THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND | | | ALL OTHER APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE ENSURE COMPLIANCE | | | | | | | | | | | | 2) THIS APPROVAL IS FOR THE BUILDING REMODEL ONLY. THE | | | PROPOSED NEW GAS PUMPS AND PROPOSED NEW CANOPY SHALL BE | | | UNDER SEPARATE PERMITS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-05-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-24 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2018-05-25 08:18:40 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF | | | THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE | | | INCLUDING THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND | | | ALL OTHER APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE ENSURE COMPLIANCE | | | | | | | | | | | | 2) THIS APPROVAL IS FOR THE BUILDING REMODEL ONLY. THE | | | PROPOSED NEW GAS PUMPS AND PROPOSED NEW CANOPY SHALL BE | | | UNDER SEPARATE PERMITS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-20 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-19 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-03-22 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-02-28 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-11 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-11-29 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-03 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-21 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-22 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-22 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2019-03-22 15:58:07 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED | | | | | | RECEIVED PALM BEACH COUNTY IMPACT FEE RECEIPT AND | | | STAMPED SET OF PLANS. | | | TRACKING NUMBER: MU-2019-002368-0000 | | | RECEIPT NUMBER: 2019-0220-353 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-01-02 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-01-02 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2019-01-02 15:49:08 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-16 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2018-06-16 13:31:03 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED | | | 561-233-5025 FOR MORE INFORMATION | | | | | | AFTER ALL OTHER PLAN REVIEWS HAVE PASSED, CHECK OUT ONE | | | SET OF PLANS TO TAKE TO PALM BEACH COUNTY. THE PLAN | | | STAMPED BY PALM BEACH COUNTY AND THE RECEIPT SHOWING | | | THAT FEES DUE WERE PAID, IF APPLICABLE, ARE TO BE | | | SUBMITTED TO THE BUILDING DIVISION. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-23 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-23 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-07 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-07 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2018-06-07 12:15:37 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18050987 | | | 6/7/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GARAGE AREA OF THE EXISTING BUILDING IS | | | UNDERGOING A CHANGE OF OCCUPANCY FROM STORAGE TO | | | MERCANTILE, AND THEREFORE MUST BE IN COMPLIANCE WITH | | | THE FBC-17 ENERGY CONSERVATION CODE. REFER TO SECTION | | | C505.1 AND SUBMIT AN ENERGY COMPLIANCE FORM IN | | | ACCORDANCE WITH SECTIOMN C101.5.1 FBC EC. | | | | | | 2) M-2: THE SUBMITTED AC CALCULATIONS ARE INDICATING | | | 75,136 BTUH OF HEATING REQUIRED WHICH EQUATES TO 22 KW, | | | HOWEVER ONLY A 15 KW HEAT STRIP IS BEING PROVIDED PER | | | THE SCHEDULE. | | | | | | 3) M-2: A DUCT SMOKE DETECTOR IS REQUIRED IN THE SUPPLY | | | DUCT OF AHU-1- SECTION 606.2.1 FBC M. | | | | | | 4) M-1: INDICATE HOW THE THREADED RODS SUPPORTING AHU-1 | | | ARE TO BE ATTACHED TO THE CONCRETE CEILING. | | | | | | 5) M-1 & M-2: THE DUCT HANGING DETAILS ARE FOR | | | RECTANGULAR DUCT HOWEVER THE PLAN SHOWS ROUND TO BE | | | INSTALLED- PLEASE REVISE THE DETAILS. | | | | | | 6) M-1: SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADENOA | | | FOR THE CONDENSER STAND. ALL SUBMITTALS MUST BEAR THE | | | APPROVAL STAMP OF THE ENGINEER OF RECORD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-06 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-06 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2019-08-06 11:42:17 | PLUMBING COMMEMTS: APPROVED | | | PROVISO | | | SEE FLORIDA SEPTIC, INC. GREASE INTERCEPTOR SPEC SHEET | | | ATTACHED TO PLAN PAGE P-2, REDLINED COMMENTS AND | | | FURNISH AND INSTALL PRODUCT TO COMPLY WITH WPB PUD | | | GS-7. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-15 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-15 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2019-03-15 10:06:51 | PLUMBING 3RD REVIEW**DENIED**FL ST 553.80 (B)2B WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1) 3RD REQUEST. PROVIDE FULL AND COMPLETE MANUFACTURES | | | INSTALLATION SPECIFICATION FOR THE GREASE INTERCEPTOR. | | | PROPERLY SIZE INTERCEPTOR EITHER TO CHAPTER 10 OF THE | | | PBC PLUMBING CODE OR TO FLORIDA ADMIN CODE (F.A.C) | | | 64E-6. YOUR SIZING ON SHT P-2 BASED ON TABLE 604.3 IS | | | INCORRECT. GPM IS BASED ON WHAT THE 3 COMPARTMENT SINK | | | IS ABLE TO DISCHARGE ALL AT ONCE NOT WHAT THE MIN GPM/ | | | PRESSURE OF A FAUCET IS SUPPOSE TO BY. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-248-2703 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-08 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-08 |
Time |
08:49 |
Sent To |
Z |
|
| Notes |
| 2019-01-08 11:25:27 | CODES IN EFFECT | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 3RD REVIEW: DENIED | | | PLUMBING COMMENTS | | | | | | 1. THE DIMENSION FROM THE SIDE WALL TO THE CENTER OF | | | THE TOILET READS 18" MIN WHICH IS NOT CODE COMPLIANT | | | THE CODE IS 16" MIN - 18" MAX. THIS WAS REVISED AND | | | CLOUDED ON P-2 BUT MUST ALSO BE CORRECTED ON THE ADA | | | TOILET DETAIL ON A-1 PER WPB FBC 107.2.1. | | | 2. 2ND REQUEST: PROVIDE THE MANUFACTURE SPECIFICATIONS | | | INCLUDING DETAILAND INSTALLATION GUIDE FOR THE GREASE | | | INTERCEPTOR PER WPB FBC 107.2.1. PLEASE CONTACT JEFF | | | ODOMS @ 561-822-2172 OR [email protected] AT THE WPB | | | UTILITIES DEPARTMENT WITH QUESTIONS. | | | 3. LOOKING AT ALL OF THE PLANS IT IS UNCLEAR WHETHER OR | | | NOT THE GREASE INTERCEPTOR WILL BE IN AN AREA SUBJECT | | | TO VEHICULAR TREAFFIC. PLEASE CLARIFY ON THE PLANS PER | | | WPB FBC 107.2.1, AND IF NECCESARY PROVIDE TRAFFIC | | | BEARING LID AND INCLUDE IN SPEC/DETAIL PER WPB FBC | | | 107.2.1. | | | 3. RE: THREE COMPARTMENT SINK; | | | A. ON THE SANITARY ISOMETRIC, IDENTIFY THE OPEN | | | RECEPTACLE (IE. WASTE )PER WPB FPC 107.2.1 AND PROVIDE | | | A TRAP FOR THE SAME RECEPTACLE PER FBC PL 1002.1. THE | | | GREASE INTERCEPTOR DOES NOT CONSTITUTE A TRAP FOR | | | FIXTURES AS LAID OUT IN FBC PL 1002.1 (2). | | | B. THE DETAIL FOR THE 3 COMPARTMENT SINK SHOWS A FLOOR | | | DRAIN. CHANGE DESCRIPTION TO WASTE RECEPTACLE TO COMPLY | | | WITH THE REQUIREMENTS OF FBC PL 802.3. | | | C. THE DETAIL FOR THE 3 COMPARTMENT SINK SHOWS THE | | | INDIRECT WASTE TRAPPED. THE TRAP IS NOT REQUIRED AS THE | | | INDIRECT WASTE CONFORMS TO THE GUIDELINES NOTED IN FBC | | | PL 802.2. | | | D. THE DETAIL FOR THE 3 COMPARTMENT SINK DESCRIBES THE | | | FIXTURE AS "SINK". CHANGE DESCRIPTION TO "SINK | | | COMPARTMENT" TO COMPLY WITH THE REQUIREMENTS OF FBC PL | | | 802.1.1 | | | E. RECONCILE THE THREE COMPARTMENT SINK WASTE PIPE ON | | | THE ISOMETRIC WITH THE DETAIL FOR THE 3 COMP. SINK | | | INDIRECT WASTE PER WPB FBC 107.2.1. | | | 4. RE: 4" TWO WAY CLEANOUT FOR THE REQUIRED SAMPLING | | | POINT FOR GREASE INTERCEPTOR; | | | A. ON THE SANITARY ISOMETRIC, SIZE THE GREASE | | | INTERCETOR EFFLUENT PIPING 4" TO ACCOMMODATE THE 4" TWO | | | WAY CLEANOUT PROVIDED AS A SAMPLING POINT PER FBC PL | | | 704.2 AND 706.2. | | | B. REMOVE THE WORDS "WITH CAP ON BOTTOM &" FROM THE | | | SAMPLING POINT NOTES PER WPB FBC 107.2.1. | | | 5. RE: WATER FOUNTAIN; | | | A. ADD THE WATER FOUNTAIN TO THE FIXTURE SCHEDULE | | | NOTING COMPLIANCE WITH FBC ACC SECTIONS 211 AND 602 PER | | | WPB FBC 107.2.1. | | | B. SHOW THE WATER FOUNTAIN ON THE A-3 PROPOSED FLOOR | | | PLAN NOTING COMPLIANCE WITH FBC ACC SECTIONS 211 AND | | | 602 PER WPB FBC 107.2.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-30 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-29 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2018-08-30 11:29:17 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE DIMENSION FROM THE SIDE WALL TO THE CENTER OF | | | THE TOILET READS 18" MIN WHICH IS NOT CODE COMPLIANT | | | THE CODE IS 16" MIN - 18" MAX PLEASE CLARIFY ON THE | | | PLAN. PER FBC ACC 604.2 | | | | | | 2. ON THE GREASE INTERCEPTOR SIZING CALCULATION YOU | | | LISTED A TABLE THAT IS USED FOR SIZING SANITARY PIPING | | | BY USING DRAINAGE FIXTURE UNITS IT'S CONFUSING BECAUSE | | | THE CODE USES GALLONS PER-MINUTE IN TABLE FBC PL | | | 1003.3.4.1 MOST SMALLER GREASE INTERCEPTORS LIKE THIS | | | ONE USE THE PDI METHOD 8.3.2, THE CALCULATIONS NEED TO | | | INCLUDE THE GPM OF THE FIXTURE, FLOW THROUGH THE | | | INTERCEPTOR AND THE GREASE RETENTION OF THE | | | INTERCEPTOR. PER WPB AMEND TO FBC 107.2.1 AND FBC PL | | | 1003.2 | | | | | | 3. THE 3 COMP SINK SHALL BE INDIRECT DRAINED PER FBC PL | | | 802.1 THE PLAN SHOWS A DETAIL OF THE INDIRECT WASTE BUT | | | THE ISOMETRIC SHOW A DIRECT CONNECTION IT SHOULD SHOW | | | THE FLOOR SINK ON THE HORIZONTAL DRAIN BEING VENTED BY | | | THE HAND SINK PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 4.PROVIDE THE MANUFACTURE SPECIFICATIONS AND | | | INSTALLATION GUIDE FOR THE GREASE INTERCEPTOR. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 5. THE SAMPLING PORT SHALL NOT HAVE SUMP BELOW IT A 4" | | | TWO WAY CLEAN OUT OR PRE MANUFACTURED SAMPLING PORT | | | SHALL BE USED. PER WPB UTILITIES DEPT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-14 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-14 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2018-06-14 16:35:10 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE SHOW COMPLIANCE FOR THE LAVATORY IN THE | | | BATHEOOM PER FBC ACC 606.2 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR | | | A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2. SHT. A-1 THE ADA TOILET ROOM DETAIL SHOWS THE DOOR | | | SWING IN THE FLOOR PLAN SHOWS IT SWING OUT PLEASE | | | CLARIFY. PER FBC ACC 603.2.3 | | | | | | 3. A WATER FOUNTAIN IS REQUIRED THE EXCEPTION IS ONLY | | | FOR OCCUPANCY'S LIC AS RESTAURANT OR OCCUPANT LOADS15 | | | OR UNDER. PER FBC PL TABLE 403.1 AND 410.2, 410.4 | | | | | | 4. A GREASE INTERCEPTOR IS REQUIRED FOR THR 3 | | | COMPARTMENT SINK AND SERVICE SINK. PER FBC PL 1003.3.1 | | | AND WPB UTILITIES DEPARTMENT FOR QUESTIONS PLEASE | | | CONTACT JEFF ODOMS @ 561-822-2172 OR [email protected] | | | | | | 5. THE TOILET IS NOT VENTED NORMALLY IT WOULD BE VENTED | | | BY THE LAVATORY. PER FBC PL 901.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-08-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-08-19 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
| 2019-08-19 16:24:28 | ****CONDITIONALLY APPROVED**** | | | | | | 1.) PRIOR TO ISSUANCE OF C.O. A LANDSCAPE PERMIT MUST | | | BE SUBMITTED | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-03-14 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2019-03-14 12:29:18 | 1.) PLAN SHOWS NO SPACE ALLOCATED FOR LANDSCAPE BUFFERS | | | ALONG BROADWAY, AS HAS BEEN DISCUSSED EXTENSIVELY. SHOW | | | A 5 FOOT LANDSCAPE BUFFER WITH CURBING (WITH THE | | | EXCEPTION OF THE CURB CUTS) AS DISCUSSED. CONTACT FOR | | | QUESTIONS. | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-01-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-01-11 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2019-01-11 09:46:54 | PLEASE INCLUDE WRITTEN RESPONSES WITH NEXT SUBMITTAL | | | | | | 1.) PLANS STILL SHOW EXPANSION OF CANOPY AND AN | | | ADDITIONAL FUELING STATION. REVISE PLANS TO OMIT THIS, | | | OR PURSUE CLASS B SPECIAL USE PERMIT AS DISCUSSED | | | SEVERAL TIMES. | | | 2.) LANDSCAPE PERMIT REQUIRED. CONTACT RAY CARANCI, | | | LANDSCAPE PLANNER, AT 561-822-1462 TO DISCUSS PREFERRED | | | SPECIES ALONG BROADWAY | | | 3.) PROVIDE A BIKE RACK ON SITE | | | 4.) PROVIDE CITY STANDARD DETAILS FOR PARKING SPACES | | | AND BIKE RACK | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-08-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-08-22 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2018-08-22 15:38:22 | | | | ****REPEAT COMMENTS**** - PLEASE INCLUDE WRITTEN | | | RESPONSES WITH NEXT SUBMITTAL | | | | | | | | | SEC. 94-515. - NONCONFORMING STRUCTURES. | | | | | | 1.) ALTERATION, EXTENSION, ENLARGEMENT, OR EXPANSION OF | | | NONCONFORMING STRUCTURE . NO ALTERATION, EXTENSION, | | | ENLARGEMENT, OR EXPANSION OF A NONCONFORMING STRUCTURE | | | WHICH INCREASES ITS NONCOMPLIANCE WITH THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS SHALL BE PERMITTED. A | | | NONCONFORMING STRUCTURE MAY BE ENLARGED OR EXPANDED | | | ONLY IN COMPLIANCE WITH THE REGULATIONS OF THIS | | | CHAPTER. ANY NONCONFORMING STRUCTURE MAY BE ALTERED TO | | | DECREASE ITS NONCONFORMITY, OR INCREASE ITS COMPLIANCE, | | | WITH THE CURRENT REGULATIONS. ADDITIONAL SITE FEATURES | | | MAY BE PERMITTED PROVIDED SUCH EXPANSION CONFORMS TO | | | THE REGULATIONS. NOTHING IN THIS SUBSECTION SHALL | | | PROHIBIT THE BUILDING OFFICIAL OR THE FIRE MARSHAL FROM | | | ORDERING THE COMPLIANCE WITH ALL APPLICABLE BUILDING | | | CONSTRUCTION AND LIFE SAFETY RELATED CODES. | | | | | | 2.) REPAIRS AND MAINTENANCE OF NONCONFORMING STRUCTURES | | | . ROUTINE REPAIRS AND MAINTENANCE OF NONCONFORMING | | | STRUCTURES OR FIXTURES, WIRING OR PLUMBING AND THE | | | REPAIR OR REPLACEMENT OF ROOFS SHALL BE PERMITTED | | | REGARDLESS OF COST. MAJOR REPAIRS, RENOVATION OR | | | RESTORATION IN AN AMOUNT NOT TO EXCEED 50 PERCENT OF | | | THE CURRENT ASSESSED VALUE OF THE NONCONFORMING | | | STRUCTURE, AS DETERMINED BY THE RECORDS OF THE PALM | | | BEACH COUNTY PROPERTY APPRAISER, MAY BE CARRIED OUT IN | | | ANY 12 MONTH PERIOD, PROVIDED THAT SUCH WORK DOES NOT | | | INCREASE THE NONCONFORMITY. THIS PROVISION SHALL NOT | | | APPLY TO NONCONFORMING YET CONTRIBUTING OR INDIVIDUALLY | | | DESIGNATED HISTORIC STRUCTURES WITHIN A HISTORIC | | | DISTRICT. | | | | | | 3.) PERMIT INDICATES THAT THE VALUE OF THE PROPOSED | | | RENOVATIONS/REPAIRS EXCEED THE 50 PERCENT THRESHOLD AS | | | OUTLINED ABOVE, SITE WILL NEED TO BE BROUGHT INTO | | | COMPLIANCE WITH THE CITY'S ZLDRS, SPECIFICALLY | | | LANDSCAPE BUFFERS, TERMINAL ISLANDS, PARKING, BIKE | | | RACKS, AND DRIVE AISLES. INCLUDE CITY STANDARD DETAILS | | | FOR STRIPING AND BIKE RACKS ON SITE PLAN. | | | | | | | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
PG |
Date |
2018-06-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-05-30 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2018-06-01 10:44:45 | | | | SEC. 94-515. - NONCONFORMING STRUCTURES. | | | | | | 1.) ALTERATION, EXTENSION, ENLARGEMENT, OR EXPANSION OF | | | NONCONFORMING STRUCTURE . NO ALTERATION, EXTENSION, | | | ENLARGEMENT, OR EXPANSION OF A NONCONFORMING STRUCTURE | | | WHICH INCREASES ITS NONCOMPLIANCE WITH THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS SHALL BE PERMITTED. A | | | NONCONFORMING STRUCTURE MAY BE ENLARGED OR EXPANDED | | | ONLY IN COMPLIANCE WITH THE REGULATIONS OF THIS | | | CHAPTER. ANY NONCONFORMING STRUCTURE MAY BE ALTERED TO | | | DECREASE ITS NONCONFORMITY, OR INCREASE ITS COMPLIANCE, | | | WITH THE CURRENT REGULATIONS. ADDITIONAL SITE FEATURES | | | MAY BE PERMITTED PROVIDED SUCH EXPANSION CONFORMS TO | | | THE REGULATIONS. NOTHING IN THIS SUBSECTION SHALL | | | PROHIBIT THE BUILDING OFFICIAL OR THE FIRE MARSHAL FROM | | | ORDERING THE COMPLIANCE WITH ALL APPLICABLE BUILDING | | | CONSTRUCTION AND LIFE SAFETY RELATED CODES. | | | | | | 2.) REPAIRS AND MAINTENANCE OF NONCONFORMING STRUCTURES | | | . ROUTINE REPAIRS AND MAINTENANCE OF NONCONFORMING | | | STRUCTURES OR FIXTURES, WIRING OR PLUMBING AND THE | | | REPAIR OR REPLACEMENT OF ROOFS SHALL BE PERMITTED | | | REGARDLESS OF COST. MAJOR REPAIRS, RENOVATION OR | | | RESTORATION IN AN AMOUNT NOT TO EXCEED 50 PERCENT OF | | | THE CURRENT ASSESSED VALUE OF THE NONCONFORMING | | | STRUCTURE, AS DETERMINED BY THE RECORDS OF THE PALM | | | BEACH COUNTY PROPERTY APPRAISER, MAY BE CARRIED OUT IN | | | ANY 12 MONTH PERIOD, PROVIDED THAT SUCH WORK DOES NOT | | | INCREASE THE NONCONFORMITY. THIS PROVISION SHALL NOT | | | APPLY TO NONCONFORMING YET CONTRIBUTING OR INDIVIDUALLY | | | DESIGNATED HISTORIC STRUCTURES WITHIN A HISTORIC | | | DISTRICT. | | | | | | 3.) PERMIT INDICATES THAT THE VALUE OF THE PROPOSED | | | RENOVATIONS/REPAIRS EXCEED THE 50 PERCENT THRESHOLD AS | | | OUTLINED ABOVE, SITE WILL NEED TO BE BROUGHT INTO | | | COMPLIANCE WITH THE CITY'S ZLDRS, SPECIFICALLY | | | LANDSCAPE BUFFERS, TERMINAL ISLANDS, PARKING, BIKE | | | RACKS, AND DRIVE AISLES. INCLUDE CITY STANDARD DETAILS | | | FOR STRIPING AND BIKE RACKS ON SITE PLAN. | | | | | | | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|