Plan Review Details - Permit 18050987
Plan Review Stops For Permit 18050987
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2019-08-20 Cont ID  
Sent By pvalenti Date 2019-08-20 Time 14:40 Rev Time 0.00
Received By pvalenti Date 2019-08-20 Time 14:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-03-22 Cont ID  
Sent By pvalenti Date 2019-03-22 Time 15:58 Rev Time 0.00
Received By pvalenti Date 2019-03-22 Time 15:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-01-02 Cont ID  
Sent By shill Date 2019-01-02 Time 15:35 Rev Time 0.00
Received By shill Date 2019-01-02 Time 15:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-09-02 Cont ID  
Sent By shill Date 2018-09-02 Time 13:08 Rev Time 0.00
Received By shill Date 2018-09-02 Time 13:02 Sent To  
Notes
2018-09-02 13:09:44****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. SEE PLUMBING COMMENTS.
  
 2. FBC A 904, PROVIDE A DETAIL FOR THE SALES COUNTER.
  
 OLD SHEETS APPEAR TO HAVE BEEN REMOVED. LOCATION OF
 SALES COUNTER NOT CLEAR, SO APPROACH CANNOT BE
 VERIFIED. THE DETAIL PROVIDED LACKS DIMENSION TO SHOW
 TOE AND KNEE CLEARANCE. SEE REQUIREMENTS FOR CHECK
 WRITING SURFACES AND SALES COUNTERS, FBC A 904, 306.
  
 NEW COMMENT:
  
 3. FBC 107, RETURN OLD SETS WHICH WERE REMOVED. DO NOT
 REMOVE PLANS FROM THE DEPARTMENT.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 13:34 Rev Time 0.00
Received By shill Date 2018-06-15 Time 15:37 Sent To  
Notes
2018-06-16 13:41:51****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. SEE PLUMBING ACCESSIBILITY COMMENTS WHICH ARE
 APPLICABLE FOR BUILDING REVIEW, FBC ACCESIBILITY.
  
 2. FBC A 904, PROVIDE A DETAIL FOR THE SALES COUNTER.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-21 Cont ID  
Sent By jpearson Date 2018-08-21 Time 07:01 Rev Time 0.00
Received By jpearson Date 2018-08-21 Time 07:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-06-15 Cont ID  
Sent By jpearson Date 2018-06-15 Time 10:17 Rev Time 0.00
Received By jpearson Date 2018-06-15 Time 08:56 Sent To  
Notes
2018-06-15 10:17:43CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C
 EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT ON ROOF PER
 CODE. NEC 210.63
 2. PROVIDE SHOW WINDOW OUTLETS PER NEC 210.62
 3. PANEL SCHEDULE SHOWS A 120/208 SERVICE AND SERVICE
 CALCULATION IS FOR 3 PHASE. RISER DIAGRAM SHOWS WIRING
 FOR A SINGLE PHASE SERVICE. PROVIDE CLARIFICATION AND
 CORRECTIONS AS NEEDED. NEC 215.5; WPB FBC 107.2.1
 4. NOTE UNDER PANEL SCHEDULE STATES THAT ALL 15 AND 20
 AMP BREAKERS SHALL BE AFCI PROTECTED, WHICH IS NOT A
 CODE REQUIREMENT FOR THIS INSTALLATION. PLEASE CLARIFY
 AND/OR CORRECT. WPB FBC 107.2.1
 5. SOME LIGHTING IS SHOWN WITHOUT THE AUTOMATIC CONTROL
 REQUIRED. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING
 CONTROLS STIPULATED IN THE FBC ENERGY CODE. FBC EC
 C405.2
 6. PLUMBING COMMENTS STATE THAT A WATER FOUNTAIN IS
 REQUIRED. PROVIDE GFCI PROTECTION FOR DRINKING
 FOUNTAIN. THE GFCI DEVICE MUST BE READILY ACCESSIBLE.
 NEC 422.5, 422.52
 7. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
 8. PLAN SHOWS 2 DIFFERENT LOAD CALCULATIONS, ONE IN A
 BLOCK NOTE AND ONE IN PANEL SCHEDULE. PROVIDE ACCURATE
 LOAD CALCULATION INCLUDING ALL LOADS. WATER HEATER IS A
 CONTINUOUS LOAD. NEC 220, 422.13
 9. PROVIDE LIGHT FIXTURE SCHEDULE. PROVIDE CHART OF
 INTERIOR LIGHTING POWER ALLOWANCES EXPRESSED IN WATTAGE
 PER THE FBC ENERGY CODE IN RELATION TO THE WATTAGE OF
 THE CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH
 CODE. FBC EC C405.4.2; WPB FBC 107.2.1
 10. SIGN CONTROLLER IS REQUIRED TO HAVE A DISCONNECT
 WITHIN SIGHT OF THE CONTROLLER. PROVIDE CORRECTION. NEC
 600.6(A)(3)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-03-08 Cont ID  
Sent By pleduc Date 2019-03-08 Time   Rev Time 0.00
Received By pleduc Date 2019-03-08 Time 10:01 Sent To  
Notes
2019-03-08 10:02:18THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
  
 PLEASE ENSURE COMPLIANCE
  
  
  
 2) THIS APPROVAL IS FOR THE BUILDING REMODEL ONLY. THE
 PROPOSED NEW GAS PUMPS AND PROPOSED NEW CANOPY SHALL BE
 UNDER SEPARATE PERMITS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-08-09 Cont ID  
Sent By pleduc Date 2018-08-09 Time   Rev Time 0.00
Received By pleduc Date 2018-08-08 Time 12:15 Sent To I
Notes
2018-08-09 15:44:57THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
  
 PLEASE ENSURE COMPLIANCE
  
  
  
 2) THIS APPROVAL IS FOR THE BUILDING REMODEL ONLY. THE
 PROPOSED NEW GAS PUMPS AND PROPOSED NEW CANOPY SHALL BE
 UNDER SEPARATE PERMITS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-05-25 Cont ID  
Sent By pleduc Date 2018-05-25 Time   Rev Time 0.00
Received By pleduc Date 2018-05-24 Time 16:34 Sent To  
Notes
2018-05-25 08:18:40THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
  
 PLEASE ENSURE COMPLIANCE
  
  
  
 2) THIS APPROVAL IS FOR THE BUILDING REMODEL ONLY. THE
 PROPOSED NEW GAS PUMPS AND PROPOSED NEW CANOPY SHALL BE
 UNDER SEPARATE PERMITS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2019-08-20 Cont ID  
Sent By pvalenti Date 2019-08-20 Time 14:41 Rev Time 0.00
Received By pvalenti Date 2019-07-19 Time 13:47 Sent To  
Notes
2019-07-22 13:47:32B24

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-03-22 Cont ID  
Sent By cpuell Date 2019-03-22 Time 16:07 Rev Time 0.00
Received By cpuell Date 2019-02-28 Time 15:23 Sent To  
Notes
2019-03-01 15:23:58B24

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-01-11 Cont ID  
Sent By cpuell Date 2019-01-11 Time 14:37 Rev Time 0.00
Received By cpuell Date 2018-11-29 Time 14:56 Sent To  
Notes
2018-11-30 14:56:19B20

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-09-02 Cont ID  
Sent By shill Date 2018-09-02 Time 13:10 Rev Time 0.00
Received By shill Date 2018-08-03 Time 10:58 Sent To  
Notes
2018-08-07 10:58:30B06

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 13:41 Rev Time 0.00
Received By shill Date 2018-05-21 Time 14:23 Sent To  
Notes
2018-05-22 14:23:14B01

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2019-03-22 Cont ID  
Sent By pvalenti Date 2019-03-22 Time 15:54 Rev Time 0.00
Received By pvalenti Date 2019-03-22 Time 15:54 Sent To  
Notes
2019-03-22 15:58:07PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED
  
 RECEIVED PALM BEACH COUNTY IMPACT FEE RECEIPT AND
 STAMPED SET OF PLANS.
 TRACKING NUMBER: MU-2019-002368-0000
 RECEIPT NUMBER: 2019-0220-353

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-01-02 Cont ID  
Sent By shill Date 2019-01-02 Time 15:48 Rev Time 0.00
Received By shill Date 2019-01-02 Time 15:48 Sent To  
Notes
2019-01-02 15:49:08PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 13:30 Rev Time 0.00
Received By shill Date 2018-06-16 Time 13:30 Sent To  
Notes
2018-06-16 13:31:03IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED
 561-233-5025 FOR MORE INFORMATION
  
 AFTER ALL OTHER PLAN REVIEWS HAVE PASSED, CHECK OUT ONE
 SET OF PLANS TO TAKE TO PALM BEACH COUNTY. THE PLAN
 STAMPED BY PALM BEACH COUNTY AND THE RECEIPT SHOWING
 THAT FEES DUE WERE PAID, IF APPLICABLE, ARE TO BE
 SUBMITTED TO THE BUILDING DIVISION.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-08-23 Cont ID  
Sent By ccole Date 2018-08-23 Time 12:18 Rev Time 0.00
Received By ccole Date 2018-08-23 Time 12:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-06-07 Cont ID  
Sent By ccole Date 2018-06-07 Time 11:37 Rev Time 0.00
Received By ccole Date 2018-06-07 Time 11:35 Sent To  
Notes
2018-06-07 12:15:371ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18050987
 6/7/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GARAGE AREA OF THE EXISTING BUILDING IS
 UNDERGOING A CHANGE OF OCCUPANCY FROM STORAGE TO
 MERCANTILE, AND THEREFORE MUST BE IN COMPLIANCE WITH
 THE FBC-17 ENERGY CONSERVATION CODE. REFER TO SECTION
 C505.1 AND SUBMIT AN ENERGY COMPLIANCE FORM IN
 ACCORDANCE WITH SECTIOMN C101.5.1 FBC EC.
  
 2) M-2: THE SUBMITTED AC CALCULATIONS ARE INDICATING
 75,136 BTUH OF HEATING REQUIRED WHICH EQUATES TO 22 KW,
 HOWEVER ONLY A 15 KW HEAT STRIP IS BEING PROVIDED PER
 THE SCHEDULE.
  
 3) M-2: A DUCT SMOKE DETECTOR IS REQUIRED IN THE SUPPLY
 DUCT OF AHU-1- SECTION 606.2.1 FBC M.
  
 4) M-1: INDICATE HOW THE THREADED RODS SUPPORTING AHU-1
 ARE TO BE ATTACHED TO THE CONCRETE CEILING.
  
 5) M-1 & M-2: THE DUCT HANGING DETAILS ARE FOR
 RECTANGULAR DUCT HOWEVER THE PLAN SHOWS ROUND TO BE
 INSTALLED- PLEASE REVISE THE DETAILS.
  
 6) M-1: SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADENOA
 FOR THE CONDENSER STAND. ALL SUBMITTALS MUST BEAR THE
 APPROVAL STAMP OF THE ENGINEER OF RECORD.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2019-08-06 Cont ID  
Sent By jesmith Date 2019-08-06 Time 11:42 Rev Time 0.00
Received By jesmith Date 2019-08-06 Time 11:41 Sent To  
Notes
2019-08-06 11:42:17PLUMBING COMMEMTS: APPROVED
 PROVISO
 SEE FLORIDA SEPTIC, INC. GREASE INTERCEPTOR SPEC SHEET
 ATTACHED TO PLAN PAGE P-2, REDLINED COMMENTS AND
 FURNISH AND INSTALL PRODUCT TO COMPLY WITH WPB PUD
 GS-7.

Review Stop P PLUMBING
Rev No 4 Status F Date 2019-03-15 Cont ID  
Sent By thunt Date 2019-03-15 Time 10:06 Rev Time 0.00
Received By thunt Date 2019-03-15 Time 08:31 Sent To  
Notes
2019-03-15 10:06:51PLUMBING 3RD REVIEW**DENIED**FL ST 553.80 (B)2B WITH
 RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
 1) 3RD REQUEST. PROVIDE FULL AND COMPLETE MANUFACTURES
 INSTALLATION SPECIFICATION FOR THE GREASE INTERCEPTOR.
 PROPERLY SIZE INTERCEPTOR EITHER TO CHAPTER 10 OF THE
 PBC PLUMBING CODE OR TO FLORIDA ADMIN CODE (F.A.C)
 64E-6. YOUR SIZING ON SHT P-2 BASED ON TABLE 604.3 IS
 INCORRECT. GPM IS BASED ON WHAT THE 3 COMPARTMENT SINK
 IS ABLE TO DISCHARGE ALL AT ONCE NOT WHAT THE MIN GPM/
 PRESSURE OF A FAUCET IS SUPPOSE TO BY.
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 [email protected]
 561-248-2703

Review Stop P PLUMBING
Rev No 3 Status F Date 2019-01-08 Cont ID  
Sent By jesmith Date 2019-01-08 Time 11:25 Rev Time 0.00
Received By jesmith Date 2019-01-08 Time 08:49 Sent To Z
Notes
2019-01-08 11:25:27CODES IN EFFECT
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 3RD REVIEW: DENIED
 PLUMBING COMMENTS
  
 1. THE DIMENSION FROM THE SIDE WALL TO THE CENTER OF
 THE TOILET READS 18" MIN WHICH IS NOT CODE COMPLIANT
 THE CODE IS 16" MIN - 18" MAX. THIS WAS REVISED AND
 CLOUDED ON P-2 BUT MUST ALSO BE CORRECTED ON THE ADA
 TOILET DETAIL ON A-1 PER WPB FBC 107.2.1.
 2. 2ND REQUEST: PROVIDE THE MANUFACTURE SPECIFICATIONS
 INCLUDING DETAILAND INSTALLATION GUIDE FOR THE GREASE
 INTERCEPTOR PER WPB FBC 107.2.1. PLEASE CONTACT JEFF
 ODOMS @ 561-822-2172 OR [email protected] AT THE WPB
 UTILITIES DEPARTMENT WITH QUESTIONS.
 3. LOOKING AT ALL OF THE PLANS IT IS UNCLEAR WHETHER OR
 NOT THE GREASE INTERCEPTOR WILL BE IN AN AREA SUBJECT
 TO VEHICULAR TREAFFIC. PLEASE CLARIFY ON THE PLANS PER
 WPB FBC 107.2.1, AND IF NECCESARY PROVIDE TRAFFIC
 BEARING LID AND INCLUDE IN SPEC/DETAIL PER WPB FBC
 107.2.1.
 3. RE: THREE COMPARTMENT SINK;
 A. ON THE SANITARY ISOMETRIC, IDENTIFY THE OPEN
 RECEPTACLE (IE. WASTE )PER WPB FPC 107.2.1 AND PROVIDE
 A TRAP FOR THE SAME RECEPTACLE PER FBC PL 1002.1. THE
 GREASE INTERCEPTOR DOES NOT CONSTITUTE A TRAP FOR
 FIXTURES AS LAID OUT IN FBC PL 1002.1 (2).
 B. THE DETAIL FOR THE 3 COMPARTMENT SINK SHOWS A FLOOR
 DRAIN. CHANGE DESCRIPTION TO WASTE RECEPTACLE TO COMPLY
 WITH THE REQUIREMENTS OF FBC PL 802.3.
 C. THE DETAIL FOR THE 3 COMPARTMENT SINK SHOWS THE
 INDIRECT WASTE TRAPPED. THE TRAP IS NOT REQUIRED AS THE
 INDIRECT WASTE CONFORMS TO THE GUIDELINES NOTED IN FBC
 PL 802.2.
 D. THE DETAIL FOR THE 3 COMPARTMENT SINK DESCRIBES THE
 FIXTURE AS "SINK". CHANGE DESCRIPTION TO "SINK
 COMPARTMENT" TO COMPLY WITH THE REQUIREMENTS OF FBC PL
 802.1.1
 E. RECONCILE THE THREE COMPARTMENT SINK WASTE PIPE ON
 THE ISOMETRIC WITH THE DETAIL FOR THE 3 COMP. SINK
 INDIRECT WASTE PER WPB FBC 107.2.1.
 4. RE: 4" TWO WAY CLEANOUT FOR THE REQUIRED SAMPLING
 POINT FOR GREASE INTERCEPTOR;
 A. ON THE SANITARY ISOMETRIC, SIZE THE GREASE
 INTERCETOR EFFLUENT PIPING 4" TO ACCOMMODATE THE 4" TWO
 WAY CLEANOUT PROVIDED AS A SAMPLING POINT PER FBC PL
 704.2 AND 706.2.
 B. REMOVE THE WORDS "WITH CAP ON BOTTOM &" FROM THE
 SAMPLING POINT NOTES PER WPB FBC 107.2.1.
 5. RE: WATER FOUNTAIN;
 A. ADD THE WATER FOUNTAIN TO THE FIXTURE SCHEDULE
 NOTING COMPLIANCE WITH FBC ACC SECTIONS 211 AND 602 PER
 WPB FBC 107.2.1.
 B. SHOW THE WATER FOUNTAIN ON THE A-3 PROPOSED FLOOR
 PLAN NOTING COMPLIANCE WITH FBC ACC SECTIONS 211 AND
 602 PER WPB FBC 107.2.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-08-30 Cont ID  
Sent By gjohnson Date 2018-08-30 Time 09:51 Rev Time 0.00
Received By gjohnson Date 2018-08-29 Time 12:40 Sent To  
Notes
2018-08-30 11:29:172ND REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE DIMENSION FROM THE SIDE WALL TO THE CENTER OF
 THE TOILET READS 18" MIN WHICH IS NOT CODE COMPLIANT
 THE CODE IS 16" MIN - 18" MAX PLEASE CLARIFY ON THE
 PLAN. PER FBC ACC 604.2
  
 2. ON THE GREASE INTERCEPTOR SIZING CALCULATION YOU
 LISTED A TABLE THAT IS USED FOR SIZING SANITARY PIPING
 BY USING DRAINAGE FIXTURE UNITS IT'S CONFUSING BECAUSE
 THE CODE USES GALLONS PER-MINUTE IN TABLE FBC PL
 1003.3.4.1 MOST SMALLER GREASE INTERCEPTORS LIKE THIS
 ONE USE THE PDI METHOD 8.3.2, THE CALCULATIONS NEED TO
 INCLUDE THE GPM OF THE FIXTURE, FLOW THROUGH THE
 INTERCEPTOR AND THE GREASE RETENTION OF THE
 INTERCEPTOR. PER WPB AMEND TO FBC 107.2.1 AND FBC PL
 1003.2
  
 3. THE 3 COMP SINK SHALL BE INDIRECT DRAINED PER FBC PL
 802.1 THE PLAN SHOWS A DETAIL OF THE INDIRECT WASTE BUT
 THE ISOMETRIC SHOW A DIRECT CONNECTION IT SHOULD SHOW
 THE FLOOR SINK ON THE HORIZONTAL DRAIN BEING VENTED BY
 THE HAND SINK PLEASE CLARIFY. PER WPB AMEND TO FBC
 107.2.1
  
 4.PROVIDE THE MANUFACTURE SPECIFICATIONS AND
 INSTALLATION GUIDE FOR THE GREASE INTERCEPTOR. PER WPB
 AMEND TO FBC 107.2.1
  
 5. THE SAMPLING PORT SHALL NOT HAVE SUMP BELOW IT A 4"
 TWO WAY CLEAN OUT OR PRE MANUFACTURED SAMPLING PORT
 SHALL BE USED. PER WPB UTILITIES DEPT.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-14 Cont ID  
Sent By gjohnson Date 2018-06-14 Time 15:51 Rev Time 0.00
Received By gjohnson Date 2018-06-14 Time 12:45 Sent To  
Notes
2018-06-14 16:35:101ST REVIEW: FBC 2017 6TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW COMPLIANCE FOR THE LAVATORY IN THE
 BATHEOOM PER FBC ACC 606.2 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR
 A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 2. SHT. A-1 THE ADA TOILET ROOM DETAIL SHOWS THE DOOR
 SWING IN THE FLOOR PLAN SHOWS IT SWING OUT PLEASE
 CLARIFY. PER FBC ACC 603.2.3
  
 3. A WATER FOUNTAIN IS REQUIRED THE EXCEPTION IS ONLY
 FOR OCCUPANCY'S LIC AS RESTAURANT OR OCCUPANT LOADS15
 OR UNDER. PER FBC PL TABLE 403.1 AND 410.2, 410.4
  
 4. A GREASE INTERCEPTOR IS REQUIRED FOR THR 3
 COMPARTMENT SINK AND SERVICE SINK. PER FBC PL 1003.3.1
 AND WPB UTILITIES DEPARTMENT FOR QUESTIONS PLEASE
 CONTACT JEFF ODOMS @ 561-822-2172 OR [email protected]
  
 5. THE TOILET IS NOT VENTED NORMALLY IT WOULD BE VENTED
 BY THE LAVATORY. PER FBC PL 901.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 5 Status P Date   Cont ID  
Sent By   Date 2019-08-19 Time   Rev Time 0.00
Received By pgreilic Date 2019-08-19 Time 16:23 Sent To B
Notes
2019-08-19 16:24:28****CONDITIONALLY APPROVED****
  
 1.) PRIOR TO ISSUANCE OF C.O. A LANDSCAPE PERMIT MUST
 BE SUBMITTED
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]
  
  

Review Stop Z ZONING
Rev No 4 Status F Date   Cont ID  
Sent By   Date 2019-03-14 Time   Rev Time 0.00
Received By pgreilic Date 2019-03-14 Time 12:20 Sent To  
Notes
2019-03-14 12:29:181.) PLAN SHOWS NO SPACE ALLOCATED FOR LANDSCAPE BUFFERS
 ALONG BROADWAY, AS HAS BEEN DISCUSSED EXTENSIVELY. SHOW
 A 5 FOOT LANDSCAPE BUFFER WITH CURBING (WITH THE
 EXCEPTION OF THE CURB CUTS) AS DISCUSSED. CONTACT FOR
 QUESTIONS.
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 3 Status F Date   Cont ID  
Sent By   Date 2019-01-11 Time   Rev Time 0.00
Received By pgreilic Date 2019-01-11 Time 09:44 Sent To  
Notes
2019-01-11 09:46:54PLEASE INCLUDE WRITTEN RESPONSES WITH NEXT SUBMITTAL
  
 1.) PLANS STILL SHOW EXPANSION OF CANOPY AND AN
 ADDITIONAL FUELING STATION. REVISE PLANS TO OMIT THIS,
 OR PURSUE CLASS B SPECIAL USE PERMIT AS DISCUSSED
 SEVERAL TIMES.
 2.) LANDSCAPE PERMIT REQUIRED. CONTACT RAY CARANCI,
 LANDSCAPE PLANNER, AT 561-822-1462 TO DISCUSS PREFERRED
 SPECIES ALONG BROADWAY
 3.) PROVIDE A BIKE RACK ON SITE
 4.) PROVIDE CITY STANDARD DETAILS FOR PARKING SPACES
 AND BIKE RACK
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2018-08-22 Time   Rev Time 0.00
Received By pgreilic Date 2018-08-22 Time 15:37 Sent To  
Notes
2018-08-22 15:38:22 
 ****REPEAT COMMENTS**** - PLEASE INCLUDE WRITTEN
 RESPONSES WITH NEXT SUBMITTAL
  
  
 SEC. 94-515. - NONCONFORMING STRUCTURES.
  
 1.) ALTERATION, EXTENSION, ENLARGEMENT, OR EXPANSION OF
 NONCONFORMING STRUCTURE . NO ALTERATION, EXTENSION,
 ENLARGEMENT, OR EXPANSION OF A NONCONFORMING STRUCTURE
 WHICH INCREASES ITS NONCOMPLIANCE WITH THE ZONING AND
 LAND DEVELOPMENT REGULATIONS SHALL BE PERMITTED. A
 NONCONFORMING STRUCTURE MAY BE ENLARGED OR EXPANDED
 ONLY IN COMPLIANCE WITH THE REGULATIONS OF THIS
 CHAPTER. ANY NONCONFORMING STRUCTURE MAY BE ALTERED TO
 DECREASE ITS NONCONFORMITY, OR INCREASE ITS COMPLIANCE,
 WITH THE CURRENT REGULATIONS. ADDITIONAL SITE FEATURES
 MAY BE PERMITTED PROVIDED SUCH EXPANSION CONFORMS TO
 THE REGULATIONS. NOTHING IN THIS SUBSECTION SHALL
 PROHIBIT THE BUILDING OFFICIAL OR THE FIRE MARSHAL FROM
 ORDERING THE COMPLIANCE WITH ALL APPLICABLE BUILDING
 CONSTRUCTION AND LIFE SAFETY RELATED CODES.
  
 2.) REPAIRS AND MAINTENANCE OF NONCONFORMING STRUCTURES
 . ROUTINE REPAIRS AND MAINTENANCE OF NONCONFORMING
 STRUCTURES OR FIXTURES, WIRING OR PLUMBING AND THE
 REPAIR OR REPLACEMENT OF ROOFS SHALL BE PERMITTED
 REGARDLESS OF COST. MAJOR REPAIRS, RENOVATION OR
 RESTORATION IN AN AMOUNT NOT TO EXCEED 50 PERCENT OF
 THE CURRENT ASSESSED VALUE OF THE NONCONFORMING
 STRUCTURE, AS DETERMINED BY THE RECORDS OF THE PALM
 BEACH COUNTY PROPERTY APPRAISER, MAY BE CARRIED OUT IN
 ANY 12 MONTH PERIOD, PROVIDED THAT SUCH WORK DOES NOT
 INCREASE THE NONCONFORMITY. THIS PROVISION SHALL NOT
 APPLY TO NONCONFORMING YET CONTRIBUTING OR INDIVIDUALLY
 DESIGNATED HISTORIC STRUCTURES WITHIN A HISTORIC
 DISTRICT.
  
 3.) PERMIT INDICATES THAT THE VALUE OF THE PROPOSED
 RENOVATIONS/REPAIRS EXCEED THE 50 PERCENT THRESHOLD AS
 OUTLINED ABOVE, SITE WILL NEED TO BE BROUGHT INTO
 COMPLIANCE WITH THE CITY'S ZLDRS, SPECIFICALLY
 LANDSCAPE BUFFERS, TERMINAL ISLANDS, PARKING, BIKE
 RACKS, AND DRIVE AISLES. INCLUDE CITY STANDARD DETAILS
 FOR STRIPING AND BIKE RACKS ON SITE PLAN.
  
  
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By PG Date 2018-06-01 Time   Rev Time 0.00
Received By pgreilic Date 2018-05-30 Time 12:32 Sent To  
Notes
2018-06-01 10:44:45 
 SEC. 94-515. - NONCONFORMING STRUCTURES.
  
 1.) ALTERATION, EXTENSION, ENLARGEMENT, OR EXPANSION OF
 NONCONFORMING STRUCTURE . NO ALTERATION, EXTENSION,
 ENLARGEMENT, OR EXPANSION OF A NONCONFORMING STRUCTURE
 WHICH INCREASES ITS NONCOMPLIANCE WITH THE ZONING AND
 LAND DEVELOPMENT REGULATIONS SHALL BE PERMITTED. A
 NONCONFORMING STRUCTURE MAY BE ENLARGED OR EXPANDED
 ONLY IN COMPLIANCE WITH THE REGULATIONS OF THIS
 CHAPTER. ANY NONCONFORMING STRUCTURE MAY BE ALTERED TO
 DECREASE ITS NONCONFORMITY, OR INCREASE ITS COMPLIANCE,
 WITH THE CURRENT REGULATIONS. ADDITIONAL SITE FEATURES
 MAY BE PERMITTED PROVIDED SUCH EXPANSION CONFORMS TO
 THE REGULATIONS. NOTHING IN THIS SUBSECTION SHALL
 PROHIBIT THE BUILDING OFFICIAL OR THE FIRE MARSHAL FROM
 ORDERING THE COMPLIANCE WITH ALL APPLICABLE BUILDING
 CONSTRUCTION AND LIFE SAFETY RELATED CODES.
  
 2.) REPAIRS AND MAINTENANCE OF NONCONFORMING STRUCTURES
 . ROUTINE REPAIRS AND MAINTENANCE OF NONCONFORMING
 STRUCTURES OR FIXTURES, WIRING OR PLUMBING AND THE
 REPAIR OR REPLACEMENT OF ROOFS SHALL BE PERMITTED
 REGARDLESS OF COST. MAJOR REPAIRS, RENOVATION OR
 RESTORATION IN AN AMOUNT NOT TO EXCEED 50 PERCENT OF
 THE CURRENT ASSESSED VALUE OF THE NONCONFORMING
 STRUCTURE, AS DETERMINED BY THE RECORDS OF THE PALM
 BEACH COUNTY PROPERTY APPRAISER, MAY BE CARRIED OUT IN
 ANY 12 MONTH PERIOD, PROVIDED THAT SUCH WORK DOES NOT
 INCREASE THE NONCONFORMITY. THIS PROVISION SHALL NOT
 APPLY TO NONCONFORMING YET CONTRIBUTING OR INDIVIDUALLY
 DESIGNATED HISTORIC STRUCTURES WITHIN A HISTORIC
 DISTRICT.
  
 3.) PERMIT INDICATES THAT THE VALUE OF THE PROPOSED
 RENOVATIONS/REPAIRS EXCEED THE 50 PERCENT THRESHOLD AS
 OUTLINED ABOVE, SITE WILL NEED TO BE BROUGHT INTO
 COMPLIANCE WITH THE CITY'S ZLDRS, SPECIFICALLY
 LANDSCAPE BUFFERS, TERMINAL ISLANDS, PARKING, BIKE
 RACKS, AND DRIVE AISLES. INCLUDE CITY STANDARD DETAILS
 FOR STRIPING AND BIKE RACKS ON SITE PLAN.
  
  
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]