Plan Review Details - Permit 18050972
Plan Review Stops For Permit 18050972
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-07-23 Cont ID  
Sent By rmcdouga Date 2018-07-23 Time 08:59 Rev Time 0.00
Received By rmcdouga Date 2018-07-23 Time 08:24 Sent To P
Notes
2018-07-23 08:25:09FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-20 Cont ID  
Sent By rmcdouga Date 2018-06-20 Time 10:26 Rev Time 0.00
Received By rmcdouga Date 2018-06-20 Time 10:26 Sent To I
Notes
2018-06-20 10:33:07FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-07-20 Cont ID  
Sent By jleahy Date 2018-07-20 Time 15:09 Rev Time 0.00
Received By jleahy Date 2018-07-20 Time 15:09 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-06-08 Cont ID  
Sent By jleahy Date 2018-06-08 Time 10:17 Rev Time 0.00
Received By jleahy Date 2018-06-08 Time 10:17 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-06-02 Cont ID  
Sent By tklarge Date 2018-06-02 Time 05:41 Rev Time 0.00
Received By tklarge Date 2018-06-02 Time 04:52 Sent To  
Notes
2018-06-02 05:41:28A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-08-08 Cont ID  
Sent By lcrespo Date 2018-08-08 Time 07:09 Rev Time 0.00
Received By lcrespo Date 2018-08-06 Time 13:51 Sent To  
Notes
2018-08-07 13:51:42RESUB ROUTED TO LCRESPO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-07-23 Cont ID  
Sent By lcrespo Date 2018-07-23 Time 15:19 Rev Time 0.00
Received By lcrespo Date 2018-07-11 Time 15:02 Sent To  
Notes
2018-07-12 15:02:22RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-20 Cont ID  
Sent By rmcdouga Date 2018-06-20 Time 10:29 Rev Time 0.00
Received By rmcdouga Date 2018-05-21 Time 13:33 Sent To  
Notes
2018-05-22 13:33:29ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-08-08 Cont ID  
Sent By lcrespo Date 2018-08-08 Time 07:25 Rev Time 0.00
Received By lcrespo Date 2018-08-08 Time 07:10 Sent To  
Notes
2018-08-08 07:26:3808/08/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-07-23 Cont ID  
Sent By lcrespo Date 2018-07-23 Time 15:18 Rev Time 0.00
Received By lcrespo Date 2018-07-23 Time 15:18 Sent To  
Notes
2018-07-23 15:18:5907/23/2018 1ST PLUMBING/POOL REVIEW **DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE DYNAMIC HEAD CALCULATIONS FOR THE MAXIMUM SYSTEM
 FLOW DOES NOT SHOW ALL FRICTION LOSS THROUGH ALL
 COMPONENTS, CHLORINATORS, HEATER, ETC., ON THE HAYWARD
 CALCULATOR CHART. ASSUME THE TOTAL FRICTION LOSS WOULD
 INCLUDE THE PIPE, FITTINGS (90-DEGREE FITTINGS, 45'S,
 TEES) AND ALSO VALVES AND FILTER. PLEASE CLARIFY, WPB
 AMENDMENT. TO FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-02 Cont ID  
Sent By tklarge Date 2018-06-02 Time 05:29 Rev Time 0.00
Received By tklarge Date 2018-06-02 Time 04:52 Sent To  
Notes
2018-06-02 05:36:431) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).
 2) SHT. 2 - VAC LINE DETAIL SHOWS THE VAC LINE AT 18
 INCHES MAIXXIMUM BELOW THE WATER LEVEL BUT THE NOT
 STATEES THAT THE VAC LINE SHALL NOT BE GREATER THAN 12
 INCHES BELOW THE MINIMUM WATER LEVEL PER ANSI /NSPI 5.
 ALSO, SEE NOTE ON SHT.1 THAT REFERS TO THE 18 INCHES
 BELOW THE WATER LEVEL PER ANSI/NSPI 5. THESE NOTES AND
 DETAIL ARE CONFLICTING. WHICH IS IT, 18 OR 12 INCHES?
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN
 DRAIN AND THE PUMP. WPB AMEND. TO FBC SEC. 107.2.1.
 4) REVISE GENERAL NOTE #8 TO REFER TO THE 2013 EDITION
 OF APSP 7.
 5) SUBMIT DOCUMENTATION THAT THE GAS POOL HEATER MEETS
 THE MINIMUM REQUIRED EFFFICIENCY AS REQUIRED BY THE
 2017 FBC-ENERGY SEC.R403.10.4.
  
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-07-18 Cont ID  
Sent By mcruz Date 2018-07-18 Time 11:34 Rev Time 0.00
Received By mcruz Date 2018-07-18 Time 11:33 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By mcruz Date 2018-05-25 Time   Rev Time  
Received By   Date 2018-05-25 Time   Sent To PC
Notes
2018-05-25 14:27:13ZONING REVIEW **FAILED**
  
 1) THE POOL EQIPMENT SHALL BE AT LEAST 8.5' FROM THE
 REAR PROPERTY LINE AND AT LEAST 6' FROM EAST PROPERTY
 LINE.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  