Plan Review Details - Permit 18050927
| Plan Review Stops For Permit 18050927 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-21 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-21 |
Time |
11:01 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-27 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-27 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2018-05-27 14:42:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED | | | SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID. | | | | | | 2. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER | | | SHEET, FBC 107. | | | | | | 3. THE ASSEMBLY SELECTED HAS A DESIGN PRESSURE | | | LIMITATION OF -52.5 WHICH DOES NOT MEET THE | | | REQUIREMENTS OF ZONES 2 AND 3. SEE GENERAL LIMITATION | | | #7 ON PAGE 4 OF 5, ENGINEERING REQUIRED. | | | | | | 4. A PRE INSPECTION IS REQUIRED PRIOR TO COMMENCEMENT. | | | INSPECTOR WILL VERIFY THAT SHEATHING IS IN GOOD | | | CONDITION, AND THAT ONLY ONE ROOF IS CURRENTLY | | | INSTALLED, FBC 107. IT IS CONTRACTOR'S RESPONSIBILITY | | | TO SCHEDULE THIS INSPECTION PRIOR TO COMMENCEMENT, | | | AFTER PERMIT IS ISSUED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-23 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-23 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-27 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-18 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2018-05-18 15:24:33 | ROUTED TO HISTORIC INBOX |
|
|
|