| Plan Review Stops For Permit 18050905 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-16 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-16 |
Time |
12:42 |
Sent To |
E |
|
| Notes |
| 2018-07-16 12:51:05 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-02 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-02 |
Time |
16:55 |
Sent To |
I |
|
| Notes |
| 2018-07-02 17:13:56 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-25 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-25 |
Time |
10:29 |
Sent To |
P |
|
| Notes |
| 2018-05-25 10:33:19 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-07-19 |
Time |
05:40 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-07-19 |
Time |
05:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-06-30 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-06-30 |
Time |
07:50 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-29 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-29 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-30 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-30 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2018-05-30 14:52:02 | THERE IS NO GAS ASSOCIATED WITH THIS POOL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-07-19 |
Time |
05:40 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-07-05 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2018-07-06 14:43:42 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-02 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-22 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2018-06-25 13:05:22 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-30 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-18 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-05-21 13:09:10 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-16 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-16 |
Time |
07:25 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-30 |
Time |
04:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-30 |
Time |
03:40 |
Sent To |
|
|
| Notes |
| 2018-06-30 04:15:10 | 1) THE TDH CALCULATIONS MUST INCCLUDE ALL THE SYSTEM | | | COMPONENTS IN THE PIPING SYSTEM INCLUDING THE FILTER. | | | THIS HAS NOT BEEN DONE.SUBMIT NEW TDH CALCULATIONS. | | | 2) IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS | | | SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL. THIS | | | IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE | | | TDH CALCULATIONS. | | | 3) INDICATE ON THE POOL PUMP SPECS WHICH PUMP IS BEING | | | INSTALLED. WPB AMEND. TO FBC SEC. 107.2.1. | | | 4) COMPILE ALL THE DOCUMENTS AND PLANS INTO TWO | | | COMPLETE SETS FOR REVIEW. WPB AMEND. TO FBC SEC. 107.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-30 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-30 |
Time |
13:46 |
Sent To |
I |
|
| Notes |
| 2018-05-30 14:49:58 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 ? 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER). | | | 2) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS FOR THE UNBLOCKABLE CHANNEL DRAIN. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 3) SUBMIT TWO COPIES OF THE MANUF. SPECIFICATIONS FOR | | | THE POOL PUMP. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-11 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-11 |
Time |
14:43 |
Sent To |
P |
|
| Notes |
| 2018-07-11 14:45:49 | FLOW RATE CORRECTION, SETBACK DIMENSIONS NOT AFFECTED. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-06-27 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-06-27 |
Time |
14:02 |
Sent To |
P |
|
| Notes |
| 2018-06-27 14:05:06 | NOTE - POOL EQUIPMENT SHALL BE 1' FROM SIDE PROPERTY | | | LINE AND AT LEAST 6' FROM REAR. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1442 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-05-23 |
Time |
|
Rev Time |
|
| Received By |
mcruz |
Date |
2018-05-23 |
Time |
|
Sent To |
PC |
|
| Notes |
| 2018-05-23 11:33:13 | NOTE - POOL EQUIPMENT SHALL BE 1' FROM SIDE PROPERTY | | | LINE AND AT LEAST 6' FROM REAR. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1442 | | | E-MAIL: [email protected] | | | |
|
|