Plan Review Details - Permit 18050859
| Plan Review Stops For Permit 18050859 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-28 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-28 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-09 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-09 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2018-08-09 07:31:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED | | | SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | 2. VALUE IS TOO LOW, FBC 109. PROVIDE A COPY OF THE | | | CONTRACT AND A COST BREAKDOWN. VALUE IS TO INCLUDE | | | LABOR, MATERIALS, OVERHEAD, PROFIT, DESIGN FEES. | | | | | | 3. OK | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-16 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2018-06-16 15:30:31 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED | | | SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | 2. VALUE IS TOO LOW, FBC 109. PROVIDE A COPY OF THE | | | CONTRACT AND A COST BREAKDOWN. VALUE IS TO INCLUDE | | | LABOR, MATERIALS, OVERHEAD, PROFIT, DESIGN FEES. | | | | | | 3. SHEET A0 STATES THIS IS A LEVEL I ALTERATION. AS | | | THERE IS RECONFIGURATION OF SPACE, THIS IS A LEVEL 2 | | | ALTERATION; REVISE, FBC EB 504. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-28 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-28 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-27 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-27 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2018-07-27 10:17:32 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30 (TEXT IN RISER DIAGRAM IS | | | ILLEGIBLE. PROVIDE CORRECTED RISER DIAGRAM WHERE ALL | | | INFORMATION IS LEGIBLE.) | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 (PANEL | | | SCHEDULES FOR EACH PANEL NOT PROVIDED, MUST HAVE EACH | | | PANEL SCHEDULE. CIRCUITS ARE NOT IDENTIFIED AS NEW OR | | | EXISTING, PROVIDE CORRECTION.) | | | 4. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE | | | OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC 109.3 | | | (THIS SHOULD BE FOR THE TOTAL OF THE JOB, NOT JUST | | | MECHANICAL AND ELECTRICAL. PROVIDE AS PREVIOUSLY | | | REQUESTED.) | | | | | | NEW COMMENTS: | | | | | | 5. LOAD CALCULATION PROVIDED FOR EACH PANEL SCHEDULE IS | | | THE TYPE OF CALCULATION USED FOR RESIDENTIAL | | | INSTALLATIONS. PROVIDE LOAD CALCULATION FOR SERVICE AND | | | EACH PANEL, INCLUDE EXISTING AND NEW LOADS TO CONFIRM | | | CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30 | | | 6. NOTE BELOW RISER DIAGRAM STATES THIS DESIGN IS BASED | | | ON 2008 ENERGY CONSERVATION, WHICH IS NOT THE CURRENT | | | CODE. PROVIDE CORRECTION. FBC PREFACE (SEE ABOVE) | | | 7. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 8. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | 9. PLAN SHOWS AN AIC CALCULATION THAT IS NOT COMPLETE. | | | AIC CALCULATION IS NOT REQUIRED UNLESS THERE IS SERVICE | | | EQUIPMENT BEING ADDED. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. WPB FBC 107.2.1; NEC 110.10 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-07 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-07 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2018-06-07 13:04:53 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SCOPE OF WORK IS NOT CLEAR ON PLAN. PROVIDE DETAILS | | | OF WORK TO BE COMPLETED. WPB FBC 107.2.1 | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30 | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | 4. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE | | | OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-07-09 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-05-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-21 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2018-05-23 13:07:33 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THERE ARE VARIOUS INCORRECT REFERENCED EDITIONS | | | INDICATED FOR THE VARIOUS FIRE CODES RELATED TO THIS | | | PROJECT. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2013 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2013 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2013 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2013 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION. | | | CLEAN AGENT SYSTEMS SHALL COMPLY WITH NFPA 2001, 2012 | | | EDITION. | | | COMMERCIAL COOKING SHALL COMPLY WITH NFPA 96, 2014 | | | EDITION. | | | | | | THOUGH THESE MAY NOT REPRESENT SIGNIFICANT IMPACT, | | | PLEASE ENSURE COMPLIANCE AS THESE CODES WILL BE USED TO | | | COMPLETE THE FIRE INSPECTIONS. | | | | | | | | | | | | 2) SHOULD THIS PERMIT BE REJECTED BY ANOTHER CITY | | | DEPARTMENT PERMIT REVIEW, PLEASE CORRECT THESE REFENCES | | | WITH REVISION CLOUDS AND RESUBMIT. | | | | | | | | | 3) PLEASE UPADTE YOUR RECORDS FOR FUTURE SUBMITTALS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-24 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-24 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2018-08-24 11:00:57 | GAS UNDER PERMIT 18080050 GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-08-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-07 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-07 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2018-08-07 12:45:38 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: PREVIOUS COMMENTS NOT COMPLIED | | | | | | 1. PLEASE SHOW THE SYSTEM PRESSURE ON THE RISER DIAGRAM | | | IT IS CONFUSING BECAUSE OF THE NUMBER OF REGULATORS | | | YOUR SHOWING, A SET OF REGULATORS ON THE TANKS ONE | | | BEFORE THE FIRST TEE, TWO AFTER THE TEE AND ONE AT EACH | | | APPLIANCE PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | YOUR SHOWING THREE DIFFERENT REGULATOR WHICH WOULD | | | THREE SYSTEM PRESSURES PLEASE SHOW THEM ON THE RISER | | | AND IF THE PRESSURE IS UNDER 2PSI INDICATE IN INCHES OF | | | WATER COLUMN. | | | | | | 2. PROVIDE MANUFACTURE SPECIFICATIONS FOR LP TANKS. PER | | | WPB AMEND TO FBC 107.2.1 IF YOU GOING TO SUBMIT THE | | | INFORMATION SPECIFICATION AND TANK DRAWING SETBACKS AND | | | SITE DRAWINGS UNDER A SEPARATE PERMIT REMOVE DRAWINGS | | | OF TANKS FROM THIS SET OF PLANS | | | | | | 4.SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS REGULATORS TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 5. CLEARLY SHOW THE CAPACITY OF LP TANK(S), TYPE OF | | | TANK (DOT OR ASME), THE DISTANCE OF THE TANK FROM THE | | | EXTERIOR BUILDING WALL AND ADJACENT PROPERTY LINES, THE | | | DISTANCE OF THE TANK FROM ALL SOURCES OF IGNITION, | | | OTHER CONTAINERS, BUILDINGS, AND THE LOCATION OF ANY | | | BUILDING OPENINGS BELOW THE RELIEF VALVE OF THE TANK | | | PER NFPA 58, TABLE 3-2.2.2. IF YOU GOING TO SUBMIT THE | | | INFORMATION SPECIFICATION AND TANK DRAWING SETBACKS AND | | | SITE DRAWINGS UNDER A SEPARATE PERMIT REMOVE DRAWINGS | | | OF TANKS FROM THIS SET OF PLANS | | | | | | | | | 6. CLEARLY INDICATE ON THE PLAN THE METHOD OF REQUIRED | | | PROTECTION FOR THE LP TANK AND APPURTENANCES PER NFPA | | | 58. AND THE TANK SHALL BE SECURELY ANCHORED TO | | | WITHSTAND 170 MPH ULT WIND LOAD PER THE FLORIDA | | | BUILDING CODE. IF YOU GOING TO SUBMIT THE INFORMATION | | | SPECIFICATION AND TANK DRAWING SETBACKS AND SITE | | | DRAWINGS UNDER A SEPARATE PERMIT REMOVE DRAWINGS OF | | | TANKS FROM THIS SET OF PLANS | | | | | | 7. FOR THE SIZING TABLE THE INFORMATION YOU PROVIDED IS | | | CONFUSING PLEASE CLARIFY, A) UNDER THE NOTES ON SHT P2 | | | YOU LIST TABLE 402.2 THERE IS NO TABLE UNDER THAT | | | SECTION, B) IF YOU GOING TO USE THE EQUATION METHOD 4-1 | | | SHOW THE EQUATIONS FOR EACH SIZE ON THE PLAN. C) | | | SECTIONS 402.4.1, 402.4.2, 402.4.2 ARE DIFFERENT SIZING | | | METHODS PLEASE CLARIFY WHICH ONE YOU ARE USING. IT | | | WOULD MAKE IT MUCH SIMPLER IF YOU JUST SPECIFIED THE | | | TABLE 402.4(25)(26)(27)(28) | | | | | | NEW COMMENT: | | | | | | 1. THE CONVECTION OVEN IS NOT SHOWN ON THE RISER | | | DIAGRAM PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-07 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-07 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2018-06-07 17:51:21 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE SHOW THE SYSTEM PRESSURE ON THE RISER DIAGRAM | | | IT IS CONFUSING BECAUSE OF THE NUMBER OF REGULATORS | | | YOUR SHOWING, A SET OF REGULATORS ON THE TANKS ONE | | | BEFORE THE FIRST TEE, TWO AFTER THE TEE AND ONE AT EACH | | | APPLIANCE PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. PROVIDE MANUFACTURE SPECIFICATIONS FOR LP TANKS. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE PLAN IS SHOWING 2 LP TANKS BUT THE NOTE ON THE | | | RISER IS LISTING 3 PLEASE CLARIFY. . PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 5. CLEARLY SHOW THE CAPACITY OF LP TANK(S), TYPE OF | | | TANK (DOT OR ASME), THE DISTANCE OF THE TANK FROM THE | | | EXTERIOR BUILDING WALL AND ADJACENT PROPERTY LINES, THE | | | DISTANCE OF THE TANK FROM ALL SOURCES OF IGNITION, | | | OTHER CONTAINERS, BUILDINGS, AND THE LOCATION OF ANY | | | BUILDING OPENINGS BELOW THE RELIEF VALVE OF THE TANK | | | PER NFPA 58, TABLE 3-2.2.2. | | | | | | 6. CLEARLY INDICATE ON THE PLAN THE METHOD OF REQUIRED | | | PROTECTION FOR THE LP TANK AND APPURTENANCES PER NFPA | | | 58. AND THE TANK SHALL BE SECURELY ANCHORED TO | | | WITHSTAND 170 MPH ULT WIND LOAD PER THE FLORIDA | | | BUILDING CODE. | | | | | | 7. I CANNOT VERIFY PIPE SIZINGOF THE SYSTEM PLEASE | | | CLARIFY THE FOLLOWING | | | A) SYSTEM PRESSURE | | | B) THE TABLE LISTED 402.4(2)(3)(20) ARE FOR NATURAL | | | GAS, IF SYSTEM IS LP GAS PROVIDE THOSE SIZING TABLES. | | | | | | 8. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-28 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-28 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-09 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-05 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-06-25 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-05-17 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-24 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-24 |
Time |
13:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-16 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-16 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2018-07-16 13:32:14 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18050859 | | | 7/16/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) COMMENT #6 FROM THE 1ST REVIEW STILL EXIST. THE | | | COMBUSTION AIR CALCULATIONS ARE NOT IN COMPLIANCE WITH | | | SECTION 304 FBC FG. SEE PREVIOUS COMMENT BELOW. | | | | | | 6) PROVIDE COMBUSTION AIR CALCULATIONS FOR ALL | | | GAS-FIRED COOKING APPLIANCES IN ACCORDANCE WITH SECTION | | | 304 FBC FG, AND INDICATE HOW THE COMBUSTION AIR WILL BE | | | PROVIDED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-01 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-05-31 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2018-06-01 07:48:01 | 1ST REVIEW FBC-2017 MECHANICAL | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-24 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-24 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-08-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-07 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-07 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2018-08-07 14:55:34 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. IF ALL FLOOR DRAIN ARE EXISTING WHAT IS THE TRAP | | | PRIMER DETAIL ON SHT P3 FOR ARE YOU ADDING OR REPLACING | | | TRAP PRIMERS TO EXITING FLOOR DRAIN PLEASE CLARIFY. PER | | | WPB AMEND TO FBC PL 407.2.1 | | | | | | 2. SHT. P3.0 ON THE TYPICAL DRAIN PIPING DETAIL IT | | | SHOWS A CHROME PTRAP AND PIPING AND A TAP TEE WHICH IS | | | CAST IRON IS THIS ACCURATE AS TO THE WAY THE HAND SINK | | | WILL BE PIPED. PER WPB AMEND TO FBC PL 407.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-07 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-07 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2018-06-07 17:45:03 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE A WATER AND SANITARY ISOMETRIC | | | DRAWING. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. ARE ALL THE FLOOR DRAINS EXISTING THERE ARE SOME | | | SHOWN ON SHT P-1.0 THAT DON'T INDICATE NEW OR EXISTING. | | | PLEASE CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE ONLY PLUMBING WORK APPEARS TO BE A NEW HAND SINK | | | IS THIS CORRECT PLEASE CLARIFY ON THE PLAN. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-06-25 |
|
|
Cont ID |
|
| Sent By |
AV |
Date |
2018-06-25 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2018-06-25 |
Time |
15:37 |
Sent To |
I |
|
| Notes |
|
|
|