| Plan Review Stops For Permit 18050512 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-20 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-20 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-03 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-03 |
Time |
14:11 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-13 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-11 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2018-06-13 08:48:06 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE APPEARS LOW FOR PROPOSED SCOPE OF WORK. | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. REFERENCE WALL TYPE W-3 ON PLAN PAGE A-2 - PROVIDE | | | INSULATION TYPE AND R-VALUE FOR EXTERIOR WALL INFILL. | | | 3. PROVIDE DEMENSIONS ON PROPOSED FLOOR PLANS. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 4. REFERENCE CONCRETE CURB DETAIL ON PLAN PAGE S-1. ANY | | | CHANGE TO DESIGN MUST BE REVIEWED AND APPROVED BY | | | DESINER OF RECORD. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 5. PROVIDE SITE PLAN. SHOW LOCATION OF BUILDING TO | | | OTHER STRUCTURES AND PROPERTY LINES. | | | FBC 107.3.5.3 ? PROVIDE A SITE PLAN TO DEMONSTRATE | | | SETBACKS AND BUILDING SEPARATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-02 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-02 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-06 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-06 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2018-06-06 13:49:15 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-1 | | | | | | SMOKE ALARM MISSING AT THE BOTTOM OF THE STAIRWAY FOR | | | THE SECOND FLOOR UNIT. ONE ON EACH LEVEL. | | | | | | R314.3 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | | LOCATIONS: | | | | | | 3.ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING | | | BASEMENTS AND HABITABLE ATTICS AND NOT INCLUDING CRAWL | | | SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR | | | DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN | | | INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE | | | ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR | | | THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL | | | IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. | | | | | | 4.SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET | | | (914 MM) HORIZONTALLY FROM THE DOOR OR OPENING OF A | | | BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS | | | WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY | | | SECTION R314.3. | | | | | | R314.3.1INSTALLATION NEAR COOKING APPLIANCES | | | . | | | SMOKE ALARMS SHALL NOT BE INSTALLED IN THE FOLLOWING | | | LOCATIONS UNLESS THIS WOULD PREVENT PLACEMENT OF A | | | SMOKE ALARM IN A LOCATION REQUIRED BY SECTION R314.3. | | | | | | 1.IONIZATION SMOKE ALARMS SHALL NOT BE INSTALLED LESS | | | THAN 20 FEET (6096 MM) HORIZONTALLY FROM A PERMANENTLY | | | INSTALLED COOKING APPLIANCE. | | | | | | 2.IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING | | | SWITCH SHALL NOT BE INSTALLED LESS THAN 10 FEET (3048 | | | MM) HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING | | | APPLIANCE. | | | | | | 3.PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED | | | LESS THAN 6 FEET (1828 MM) HORIZONTALLY FROM A | | | PERMANENTLY INSTALLED COOKING APPLIANCE | | | | | | KITCHEN OUTLET MISSING IN KITCHEN ON COUNTER NEXT TO | | | STOVE 12" OR LARGER. | | | | | | | | | PAGE E-2 | | | | | | OUTLET NEEDED ON FRONT AND REAR OF UNIT #4 OUTSIDE | | | | | | E3901.7 OUTDOOR OUTLETS. | | | NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY | | | ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE | | | INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH | | | DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL. | | | BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM | | | INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE | | | RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE | | | BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE | | | LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE | | | THE BALCONY, DECK, OR PORCH SURFACE. [210.52(E)] | | | | | | | | | PAGE E-3 | | | | | | LOAD CALCULATIONS SHOULD BE DONE IN ACCORDANCE WITH THE | | | CODE, YOU CAN NOT TAKE A DEMAND ON EACH UNIT AND THEN | | | JUST ADD THEM TOGETHER TO GET A TOTAL. | | | | | | 250.94 INTERSYSTEM BONDING SYSTEM REQUIRED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-13 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-13 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-05-21 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-18 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2018-05-21 10:14:37 | THE PLANS INDICATED THIS IS A DUPLEX, EXEMPT FROM FIRE | | | CODE REVIEW. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-20 |
Time |
04:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-20 |
Time |
04:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-08 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-08 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2018-06-08 08:19:27 | 1) SHT. A-1.1 - SHOW THE DISTANCE OF THE TANKLESS WATER | | | HEATERS FROM ALL OPERABLE WINDOWS, DOORS AND BUILDING | | | OPENINGS (INCLUDING SOFFIT VENTS). THE LOCATION OF THE | | | TANKLESS WATER HEATERS SHALL COMPLY WITH THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS. WPB AMEND. TO | | | FBC SEC. 107.2.1. | | | 2) SUBMIT TWO COPIES OF THE MANUFACTURER'S INSTALLATION | | | MANUAL FOR THE TANKLESS WATER HEATERS. WPB AMEND. TO | | | FBC SEC. 107.2.1. | | | 3) INDICATE ON THE PLAN IF THE FIREPLACE IS GAS OR | | | SOLIDD FUEL BURNING. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-07-19 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-07-19 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-23 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-23 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2018-05-23 13:54:41 | WINDOW PRODUCT/DETAILS NOT CLEAR....NEW WINDOWS SHALL | | | BE 6/1 SINGLE HUNG WOOD OR ALUMINUM, WHITE FRAME, CLEAR | | | GLASS. QUESTIONS CONTACT: FRIEDERIKE MITTNER, CITY | | | HISTORIC PRESERVATION PLANNER AT (561) 822-1457 OR | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-03 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-07-03 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-13 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-10 |
Time |
13:47 |
Sent To |
I |
|
| Notes |
| 2018-05-14 13:47:44 | C13 | | | **TRAVELLING TOGETHER - 18050512 & 18050513** |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2018-08-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-03 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-03 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2018-08-03 14:34:27 | NO NOTES |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-13 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-11 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-08-01 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-08-01 |
Time |
15:46 |
Sent To |
E |
|
| Notes |
| 2018-08-01 15:50:13 | PASS PROVISO | | | REFER TO SECTION R403.36 AIR HANDLING UNITS. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-07-25 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-07-25 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2018-07-25 15:00:21 | PASS PROVISO | | | REFER TO SECTION R403.3.6 AIR HANDLING UNITS | | | 2017 FLORIDA ENERGY CODE. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-11 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-11 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2018-06-11 09:38:10 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18050512 | | | UNITS 1 & 2 | | | 6/11/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEMS- SECTION 312.1 FBC M. | | | | | | 2) INDICATE HOW THE APARTMENTS ARE TO BE VENTILATED- | | | NATURALLY IN ACCORDANCE WITH SECTION 402 FBC M, OR | | | MECHANICALLY PER SECTION 403 FBC M. CHOOSE WHICHEVER | | | METHOD AND PROVIDE CALCULATIONS. | | | | | | 3) DESIGN CRITERIA: PROVIDE A LIST OF CURRENT CODES AND | | | STANDARDS USED IN THE DESIGN OF THE PROPOSED PROJECT. | | | | | | 4) INDICATE THE"CLASSIFICATION OF WORK" FOR THE | | | PROPOSED PROJECT IN ACCORDANCE WITH SECTIONS 502, 503, | | | 504, 505, 506, 507, 508, & 09 FBC EX. | | | | | | 5) SHEET M1: THE 2ND FLOOR AC CLOSET DOOR SHALL BE | | | NON-COMBUSTIBLE OR HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE | | | THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL | | | 723. | | | | | | 6) M1: THE PLANS INDICATE FIRE PLACES IN THE LIVING | | | ROOMS OF THE1ST AND 2ND FLOOR APARTMENTS. PROVIDE | | | COMPLETE INFOMATION ABOUT THESE UNITS- MAKES AND MODEL | | | NUMBERS, TYPE OF FUEL, COMBUSTION AIR, VENTING PLANS, | | | CLEARANCES TO COMBUSTIBLES ETC. MANUFACTURER'S | | | SPECIFICATIONS MUST BE SUBMITTED WITH APPROVAL STAMPS | | | BY THE EOR- SECTIONS 903 & 905 FBC M, AND SECTIONS 602, | | | 604, & 605 FBC FG. | | | | | | 7) M1: SUBMIT MANUFACTURER'S SPECIFICATION FOR THE | | | DRYER, RECIRCULATION HOOD, AND THE RANGE- SECTIONS | | | 504.1,505.1, & 917.1, FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-20 |
Time |
04:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-20 |
Time |
03:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-08 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-07 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2018-06-07 14:21:44 | 1) THE WATER SUPPLY VALVES FOR THE STACKABLE | | | WASHER/DRYER UNIT SHALL BE PROVIDED WITH ACCESS. 2017 | | | FBC-PLUMBING SEC.606.3. | | | 2) SHT. A-13 - SHOW THE WIDTH OF THE SHOWER IN UNIT #4 | | | ON THE FLOOR PLANS. THE SIZE OF THE SHOWER SHALL COMPLY | | | WITH 2017 FBCV-PLUMBING SEC. 417.4. | | | 3) SHOW THE FIXTURE CLEARANCES OF THE PLUMBING FIXTURES | | | IN ALL THE UNITS PER 2017 FBC-PLUMBING SEC.405. | | | 4) SUBMIT FIRESTOPPING DETAILS FOR ALL PIPE PENTRATIONS | | | THROUGH THE FLOOR TO THE 2ND FLOOR. | | | 5) THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING | | | FROM THE SOURCE OF HOT WATER TO THE FIXTURES THAT | | | REQUIRE HOT OR TEMPERED WATER SHALL NOT EXCEED 50 FEET | | | PER 2017 FBC-PLUMBING SEC.607.2. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-23 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-23 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|