| Plan Review Stops For Permit 18050501 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-13 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-13 |
Time |
13:46 |
Sent To |
I |
|
| Notes |
| 2018-06-13 14:35:10 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA. | | | THE POOL EQUIPMENT IS REQUIRED TO BE LOCATED AT OR | | | ABOVE THE FINISH FLOOR ELEVATION OF THE DWELLING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-22 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-22 |
Time |
09:48 |
Sent To |
E |
|
| Notes |
| 2018-05-22 09:58:56 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ADDRESS ON THE PLANS, 112 POTTER ROAD, DOES NOT | | | MATCH THE ADDRESS LISTED ON THE APPLICATION, 120 POTTER | | | ROAD. FBC 107.2.1 | | | | | | 2) NOTE: FBC-R4501.19 FINAL INSPECTION. FINAL | | | ELECTRICAL AND BARRIER CODE INSPECTION SHALL BE | | | COMPLETED PRIOR TO FILLING THE POOL WITH WATER. | | | | | | 3) THE PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (AE FLOOD ZONE). THE POOL EQUIPMENT SHALL BE | | | ELEVATED TO OR ABOVE THE FINISH FLOOR ELEVATION OF THE | | | LIVING SPACE OF THE DWELLING UNIT. FBC-R322 | | | | | | 4) SUBMIT TWO SETS OF THE MANUFACTURER'S SPECIFICATIONS | | | AND PRODUCT LISTING THAT SHOWS COMPLIANCE WITH UL 2017 | | | FOR THE WINDOW AND DOOR ALARMS. FBC 107.2.1.2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-13 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-13 |
Time |
12:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-29 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-29 |
Time |
10:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-06-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-06 |
Time |
06:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-06 |
Time |
06:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-05-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-19 |
Time |
05:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-19 |
Time |
05:16 |
Sent To |
|
|
| Notes |
| 2018-05-19 05:18:32 | 1) THE ADDRESS ON THE GAS PLAN IS 112 POTTER RD, AND | | | THE ADDRESS FOR THE POOL IS 120 RD. CLARIFY. | | | 2) SUBMIT A CLEAR AND LEGIBLE GAS RISER FOR REVIEW.PIPE | | | SIZES, TYPE OF PIPE AND SOME DISTANCES ARE ILLEGBLE AND | | | A COMPREHENSIVE REVIEW COULD NOT BE DONE DUE TO THE | | | PRINTING BEING EXTREMELY DIFFICULT TO READ. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 3) SHOW THE EHD OF 1/2 INCH CSST. WPB AMEND. TO FBC | | | SEC. 107.2.1. | | | 4) CLEARLY SHOW THE LENGTHS OF ALL CUT SECTIONS OF | | | PIPE. 2017 FBCR SEC.G2413.4.1, G2413.4.2. | | | 5) MANUF. SPECS FOR ALL APPLIANCES & EQUIPMENT SHALL BE | | | SUBMITTED FOR REVIEW. 2017 FBCR SEC. G2404.3. | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2017 FGC SEC.410.1, 2017 FBC-RES. SEC. | | | G2421.1. | | | 7) SHOW THE SIZE OF THE BRANCH LINES TO THE POOL HEATER | | | AND THE GENERATOR. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-13 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-07 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2018-06-08 14:11:18 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-29 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-10 |
Time |
11:26 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-11 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-06-11 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-06-11 |
Time |
18:46 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-19 |
Time |
05:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-19 |
Time |
04:12 |
Sent To |
|
|
| Notes |
| 2018-05-19 05:15:52 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS PER 2013 | | | APSP-7 SEC. 4.4.9.THE TDH CALCULATIONS SHALL BE THE | | | TOTAL FRICTION LOSS OF ALL SYSTEM COMPONENTS EXCEPT THE | | | PUMP. THE MAXIMUM FLOW OF THE PUMP FROM THE PUMP CURVE | | | CAN NO LONGER BE USED TO DETEREMINE MAXIMUM SYSTEM FLOW | | | RATE. | | | 2) WHY HAS A SURVEY FOR LOT 30 BEEN SUBMITTED? CLARIFY. | | | 3) SHT. 2 OF 2 - GENERAL NOTES - PLEASE REVISE NOTE #8 | | | - THE 2013 EDITION OF APSP 7 IS IN EFFECT, NOT 2006. | | | THIS ALSO OCCURS IN NOTE #16. | | | 4) GENERAL NOTE #15 REFERS TO THE 2014 FBC.REVISE TO | | | 2017 FBC. | | | 5) AN REDUCED PRESSURE ZONE BACKFLOW DEVICE IS REQUIRED | | | AT THE WATER METER AND A PRESSURE VACUUM BREAKER | | | BACKFLOW DEVICE IS REQUIRED ON THE AUTOFILL PER CITY OF | | | WPB CROSS CONNECTION CONTROL MANUAL & FBC-PLUMBING | | | SEC.608 & TABLE 608.1. | | | 6) THE VACUUM LINE SHALL BE EQUIPPED WITH A VALVE TO | | | REMAIN IN THE CLOSED POSITION WHEN NOT IN USE. APSP 7 | | | SEC.4.6. | | | 7) | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-11 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-06-11 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-06-11 |
Time |
11:25 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-29 |
Time |
10:05 |
Rev Time |
|
| Received By |
|
Date |
2018-05-16 |
Time |
|
Sent To |
B |
|
| Notes |
| 2018-05-16 09:24:02 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) INDICATE ON SURVEY THE SETBACK FROM POOL EQUIPMENT | | | TO ADJACENT PROPERTY LINE AND CONFIGURATION OF PROPOSED | | | POOL AND SETBACKS FROM TO POOL TO PROPERTY LINES. | | | CURRENTLY, INFORMATION IS ON DIFFERRENT DOCUMENTS. | | | 2) IS THE PROPOSED POOL FOR 112 POTTER RD.? THE | | | APPLICATION INDICATES IT'S FOR 120 POTTER RD. AND | | | SURVEYS OF 120 POTTER WERE INCLUDED WITH SUBMITTAL, | | | PLEASE CLARIFY. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | 561-822-1442 | | | [email protected] | | | |
|
|