Plan Review Details - Permit 18050484
| Plan Review Stops For Permit 18050484 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-05-31 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-07 |
Time |
19:13 |
Sent To |
|
|
| Notes |
| 2018-05-31 15:11:03 | CLICKED ON THE BUIDING LINE BY MISTAKE JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-21 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-21 |
Time |
09:56 |
Sent To |
I |
|
| Notes |
| 2018-06-22 10:12:05 | CHANGED STATUS TO NR AND REMOVED ELECTRICAL SHEETS FROM | | | THIS REVISION PER EMAIL FROM EOR. | | | | | | | | | | | 2018-06-21 09:56:38 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE BLOCK NOTE THAT FIRE PUMP WILL BE UNDER | | | SEPARATE PERMIT. WPB FBC 105.1, 107.2.1 | | | 2. PROVIDE CORRECTED LOAD CALCULATION WITH ADDITION OF | | | FIRE PUMP LOAD. NEC 220; WPB FBC 107.2.1, 107.3.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-31 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-31 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2018-05-31 15:10:00 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-DEW-02A | | | | | | CLOUDED AREA AT BOTTOM SHOWING FP NEED TO KNOW WHAT | | | CIRCUITS ARE NEEDED AND SIZES AND WHERE FED FROM. | | | | | | | | | PAGE E-DEW-15A | | | | | | SHOW LOCATION OF FIRE PUMP IN BUILDING. THE BLOWUP OF | | | THE ROOM DOES NOT SHOW WHERE IT IS LOCATED. | | | | | | FIRE PUMP SKID AS A DESCRIPTION IS NOT ACCEPTABLE WHAT | | | SIZE IS THE PUMP DOES IT HAVE AND CONTROLLER IF SO | | | SUBMIT ALL PAPER WORK SHOWING LISTINGS FOR ALL FIRE | | | PUMP EQUIPMENT. | | | | | | SOURCES OF POWER ARE THESE FROM FPL CITY DOES NOT | | | ACCEPT FPL AS A RELIABLE SOURCE. | | | | | | HOW DO THE FEEDS ENTER THE BUILDING?? UNDERGROUND? WHAT | | | TYPE OF PIPE? SIZE OF CONDUCTORS? | | | | | | | | | REVISION SHOWS NO ADDED VALUE FOR THE FIRE PUMP AND | | | CONTROLLER PLEASE ADD TO NEXT REVISION. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO | | | PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM ALONG | | | WITH THE CITY RESUBMITTAL FORM. ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE OR VOID THE PREVIOUSLY REVIEWED | | | SHEETS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-05-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-05-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-18 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-22 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-15 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2018-06-18 15:55:19 | RESUB OF REVISION ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-07 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-10 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-05-23 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-05-23 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
|