Plan Review Details - Permit 18050364
Plan Review Stops For Permit 18050364
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-06 Cont ID  
Sent By skennedy Date 2018-08-06 Time 11:15 Rev Time 0.00
Received By skennedy Date 2018-08-06 Time 11:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-07 Cont ID  
Sent By skennedy Date 2018-06-07 Time 14:06 Rev Time 0.00
Received By skennedy Date 2018-06-07 Time 13:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-07-30 Cont ID  
Sent By ppetty Date 2018-07-30 Time 09:33 Rev Time 0.00
Received By ppetty Date 2018-07-30 Time 09:27 Sent To  
Notes
2018-07-30 09:27:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: OK, SEE COMMENTS BELOW.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-06-22 Cont ID  
Sent By jleahy Date 2018-06-22 Time 16:52 Rev Time 0.00
Received By jleahy Date 2018-06-22 Time 16:05 Sent To  
Notes
2018-06-22 16:06:12SEE NOTES ON ELECTRICAL PAGE JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-05-23 Cont ID  
Sent By jpearson Date 2018-05-23 Time 14:56 Rev Time 0.00
Received By jpearson Date 2018-05-23 Time 07:54 Sent To  
Notes
2018-05-23 14:56:36CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL SERVICE NOTE 6 DOES NOT CORRECTLY
 IDENTIFY THE AREAS REQUIRING AFCI PROTECTION. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. PROVIDE CORRECTION. NEC
 210.12; FBC RE E3902.16
 2. ELECTRICAL SERVICE NOTE 15 STATES THAT LIGHTING IN
 CLOTHES CLOSETS SHALL COMPLY WITH NEC 4/10.8/D/1, WHICH
 DOESN?T EXIST. PROVIDE CORRECTION. NEC 410.16; FBC RE
 E4003.12
 3. ELECTRICAL SPECIFICATIONS NOTE 2 QUOTES THE 2011
 NEC, WHICH IS NOT THE CURRENT CODE. PROVIDE CORRECTION.
 FBC PREFACE (ALSO SEE CURRENT CODES ABOVE)
 4. SMOKE ALARM BLOCK NOTE QUOTES THE 2014 FBC, WHICH IS
 NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE
 (ALSO SEE CURRENT CODES ABOVE)
 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 6. RECEPTACLES IN STORAGE AREAS REQUIRE GFCI
 PROTECTION. PROVIDE CORRECTIOIN. NEC 210.8; FBC RE
 E3902.2
 7. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A
 TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST
 ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND
 NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE
 INSTALLED AT THE FRONT AND BACK OF THE DWELLING.
 PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7
 8. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C
 EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-06-05 Cont ID  
Sent By fmittner Date 2018-06-05 Time 10:29 Rev Time 0.00
Received By fmittner Date 2018-06-05 Time 10:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-08-06 Cont ID  
Sent By skennedy Date 2018-08-06 Time 11:51 Rev Time 0.00
Received By skennedy Date 2018-07-20 Time 09:54 Sent To  
Notes
2018-07-24 09:54:12R05

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-29 Cont ID  
Sent By thunt Date 2018-06-29 Time 15:28 Rev Time 0.00
Received By thunt Date 2018-06-25 Time 15:23 Sent To I
Notes
2018-06-26 15:23:21RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status P Date 2018-06-07 Cont ID  
Sent By skennedy Date 2018-06-07 Time 14:07 Rev Time 0.00
Received By skennedy Date 2018-05-08 Time 12:48 Sent To  
Notes
2018-05-09 12:49:00R11

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-05-22 Cont ID  
Sent By cmontell Date 2018-05-22 Time 14:50 Rev Time 0.00
Received By cmontell Date 2018-05-22 Time 14:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-08-06 Cont ID  
Sent By skennedy Date 2018-08-06 Time 11:51 Rev Time 0.00
Received By skennedy Date 2018-08-06 Time 11:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-06-29 Cont ID  
Sent By thunt Date 2018-06-29 Time 15:20 Rev Time 0.00
Received By thunt Date 2018-06-29 Time 15:20 Sent To  
Notes
2018-06-29 15:28:2706/29/2018 2ND PLUMBING REVIEW**DENIED**
  
 COMMENTS SUBMITTED BY PLUMBING CONTRACTOR MUST BE
 PLACED ONTO PLAN. ALSO SUBMITTAL DOCUMENTS ARE NOT
 PERMITTED TO BE IN PENCIL. FBC 107.3.5
  
 1) **CHANGES MUST BE MADE ON PLAN BY ARCHITECT OF
 RECORD**SANITARY ISOMETRIC IS SHOWING BATH #2 HAS 2 WET
 VENTED FIXTURES PASSED THE DRY VENT. ONLY 1 WET VENTED
 FIXTURE IS PERMITTED BEYOND THE DRY VENT. FBC R
 P3108.2.1
  
 2) **CHANGES MUST BE MADE ON PLAN BY ARCHITECT OF
 RECORD**PLUMBING NOTES LIST NEW COLD WATER PIPING TO BE
 PVC SCH 40. PVC IS ONLY PERMITTED OUTSIDE, UNDERGROUND
 AND SHALL TERMINATE AT OR BEFOR THE FULL OPEN VALVE AT
 THE ENTRANCE OF THE HOME. WATER DISTRIBUTION PIPING (
 INSIDE OF HOME) SHALL BE OF 1 OF THE MATERIALS OF
 PIPING LISTED IN TABLE FBC R P 2906.5
  
 3) **CHANGES MUST BE MADE ON PLAN BY ARCHITECT OF
 RECORD**PLUMBING NOTES LIST ALL SANITARY PIPING TO BE
 1/8" PER FOOT. NOT ALL PIPE SIZES ARE PERMITTED TO HAVE
 A MIN 1/8" PITCH AS IN TABLE FBC R P3005.4.2 PLEASE ADD
 COMMENT IN REGRADS TO SMALLER SIZES OR REMOVE NOTES ALL
 TOGETHER AS THIS IS A GENERAL MIN CODE REQUIREMENT THAT
 EVER PLUMBER SHOULD KNOW.
  
 4) NO RESPONCE**PROVIDE SPEC/ INSTALLATION MANUAL FOR
 THE WATER HEATER. ALSO PLEASE ADD NOTE TO THE WATER
 HEATER ON SHT. E1.0 AND SHT. A1.0 SHOWING MIN E.F WILL
 BE .97 E.F. PER YOUR R405-2017 FORM LIST THE WATER
 HEATER AS .97 E.F AND IS ABOVE THE MIN .95 E.F BUT
 SHOWING AS NEEDED FOR YOUR COMPLIANCE WITH THE
 R405-2017 FORM.
  
 5) **CHANGES MUST BE MADE ON PLAN BY ARCHITECT OF
 RECORD**PROVIDE RELIEF LINE AND PAN DRAIN DISCHARGE
 PIPING DETAIL SHOW HOW YOU ARE COMPLYING WITH FBC R
 P2804.6.1. RELIEF LINE SHALL DISCHARGE INTO THE ROOM OF
 THE WATER HEATER AND ARE NOT PERMITTED TO BE TRAPPED.
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-06 Cont ID  
Sent By thunt Date 2018-06-06 Time 15:39 Rev Time 0.00
Received By thunt Date 2018-06-06 Time 15:04 Sent To  
Notes
2018-06-06 15:54:3206/06/2018 1ST PLUMBING REVIEW**DENIED**
  
 1) SANITARY ISOMETRIC IS SHOWING BATH #2 HAS 2 WET
 VENTED FIXTURES PASSED THE DRY VENT. ONLY 1 WET VENTED
 FIXTURE IS PERMITTED BEYOND THE DRY VENT. FBC R
 P3108.2.1
  
 2) PLUMBING NOTES LIST NEW COLD WATER PIPING TO BE PVC
 SCH 40. PVC IS ONLY PERMITTED OUTSIDE, UNDERGROUND AND
 SHALL TERMINATE AT OR BEFOR THE FULL OPEN VALVE AT THE
 ENTRANCE OF THE HOME. WATER DISTRIBUTION PIPING (
 INSIDE OF HOME) SHALL BE OF 1 OF THE MATERIALS OF
 PIPING LISTED IN TABLE FBC R P 2906.5
  
 3) PLUMBING NOTES LIST ALL SANITARY PIPING TO BE 1/8"
 PER FOOT. NOT ALL PIPE SIZES ARE PERMITTED TO HAVE A
 MIN 1/8" PITCH AS IN TABLE FBC R P3005.4.2 PLEASE ADD
 COMMENT IN REGRADS TO SMALLER SIZES OR REMOVE NOTES ALL
 TOGETHER AS THIS IS A GENERAL MIN CODE REQUIREMENT THAT
 EVER PLUMBER SHOULD KNOW.
  
 4) PROVIDE SPEC/ INSTALLATION MANUAL FOR THE WATER
 HEATER. ALSO PLEASE ADD NOTE TO THE WATER HEATER ON
 SHT. E1.0 AND SHT. A1.0 SHOWING MIN E.F WILL BE .97
 E.F. PER YOUR R405-2017 FORM LIST THE WATER HEATER AS
 .97 E.F AND IS ABOVE THE MIN .95 E.F BUT SHOWING AS
 NEEDED FOR YOUR COMPLIANCE WITH THE R405-2017 FORM.
  
 5) PROVIDE RELIEF LINE AND PAN DRAIN DISCHARGE PIPING
 DETAIL SHOW HOW YOU ARE COMPLYING WITH FBC R P2804.6.1
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2018-06-07 Cont ID  
Sent By skennedy Date 2018-06-07 Time 14:07 Rev Time 0.00
Received By skennedy Date 2018-06-07 Time 14:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-06-05 Cont ID  
Sent By fmittner Date 2018-06-05 Time 10:29 Rev Time 0.00
Received By fmittner Date 2018-06-05 Time 10:29 Sent To  
Notes
***NONE***