| Plan Review Stops For Permit 18050277 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
P |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-02-24 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-02-19 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2020-02-19 13:29:20 | ADDRESS STABLISHED AS 2022 BANYAN RESORT WAY BY MORIO & | | | SHILL |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-22 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2019-03-22 08:39:05 | ADDRESS UPDATED | | | 2020 BANYAN RESORT WAY |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-14 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-13 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2018-12-13 13:21:34 | 1. AN ADDRESS WILL NEED TO BE ESTABLISHED FOR THIS | | | STRUCTURE. | | | PLEASE CALL MICHAEL ORIO BY PHONE AT 561-494-1080, OR | | | BY E-MAIL [email protected] | | | | | | 2. UPON ADDRESS ASSIGNMENT, PLEASE UPLOAD COVER SHEET | | | WITH NEW ADDRESS ON IT. | | | | | | COMMENT BY: | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | THE CITY OF WEST PALM BEACH | | | BUILDING PLANS EXAMINER PX4191 | | | COMMERCIAL BUILDING INSPECTOR BN7557 | | | | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-20 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-20 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2018-06-20 13:14:40 | ADDRESS ON THE PLAN IS NOT IN OUR RECORDS (1998 | | | LACELEAF COURT). | | | | | | CONTACT: | | | | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-17 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-22 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2019-03-22 08:56:15 | PROVISOS: | | | 1) SUBMITTAL FOR ALL FENESTRATION (WINDOW, DOORS, | | | LOUVERS) | | | 2) ROOFING PRODUCT APPROVALS SUBMITTED WITH SUB PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-13 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-12 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2019-01-14 10:10:07 | UPON ADDRESS ASSIGNMENT, PLEASE UPLOAD COVER SHEET WITH | | | NEW ADDRESS ON IT. | | | | | | COMMENT BY: | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | THE CITY OF WEST PALM BEACH | | | BUILDING PLANS EXAMINER PX4191 | | | COMMERCIAL BUILDING INSPECTOR BN7557 | | | | | 2018-12-13 13:24:56 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18050277 | | | | | | 1ST REVIEW | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 2ND REVIEW: DECEMBER 12, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. OK | | | | | | 2 A1.0.04, HOW OCCPUANT LOAD OF 106 WAS DETERMINED IS | | | NOT CLEAR. | | | 2ND REVIEW: | | | A) 2-2 SHEET A-0.0.02 BUILDING OCCUPANY TABLE DOESN?T | | | MATCH OCCUPANT LOAD TABLE 1004.1.2. | | | B) REQUIRED FIXTURE TABLE STATES A-3 OCCUPANCY, BUT IT | | | SHOULD BE A-2. PLEASE ADJUST TO MATCH BUILDING CODE | | | DATA. | | | C) OCCUPANCY USED FOR REQUIRED FIXTURES SHOULD MATCH | | | THE BUILDING OCCUPANCY CURRENTLY IT SAY 166 PERSONS FOR | | | PLUMBING COUNT AND 106 FOR BUILDING OCCUPANCY. | | | D) THE AMOUNT OF FIXTURES PROVIDED DOESN?T MATCH WHAT | | | SHOWS IN PLAN VIEW ON SHEET A-1.0.05 AND PLUMBING | | | SHEETS. | | | PLEASE MATCH NUMBERS OF FIXTURE PROVIDED. | | | E) REVIEW BUILDING OCCUPANCY AND USE FUNCTIONS FROM | | | TABLE 1004.1.2 TO DETERMINE THE OCCUPANT LOAD [FBC | | | 1004.6]MULTIPLE OCCUPANCIES | | | EXAMPLE: | | | A) 200 GROSS - KITCHENS COMMERCIAL I SEE THE INTERIOR | | | COMMERCIAL KITCHEN AS APPROX. 400 SQ. PLUS THE OUTSIDE | | | SERVING CAN BE INCLUDED. | | | B) 300 GROSS ? STORAGE. THE SECTION BEHIND THE KITCHEN | | | IS ABOUT 1574 SQ. FT | | | | | | C) 15 GROSS ? UNCONCENTRATED TABLES AND CHAIRS. THE | | | OUTSIDE EATING CAN BE JUST THE AREA FROM BARS EDGE TO | | | ROOFS EDGE. | | | PLEASE UPDATE SO AREAS ARE CLEAR | | | SQ. FOOTAGE UNDER AIR, SQ. FOOTAGE FOR OUTDOOR EATING | | | AND TOTAL SQ. FOOTAGE. | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. OK | | | | | | NEW COMMENTS: | | | 7. REMOVE SHEET AGA A-1.0.0.01 SITE PLAN SINCE SHEET | | | AGA A.0.0.05 IS THE APPROVED SITE PLAN. SHEETS AGA | | | A1.0.02 AND AGA A1.0.03 MAY NOT BE NEEDED IN THE SET | | | EITHER. | | | | | | 8. SHEET A-1.0.04 INFORMATION ON SHEET IS NOT SHOWING | | | UP. PLEASE RE-LOAD THE SHEET WITH INTENDED CONTENT. | | | | | | 9. [FBC ENERGY C401.2]APPLICATION. | | | COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING: | | | 1.THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, EXCLUDING | | | SECTION 9.4.1.1(G) OF THE STANDARD. | | | 2.THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN | | | ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH | | | SECTION C406 AND TENANT SPACES SHALL COMPLY WITH | | | SECTION C406.1.1. | | | 3.THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404, | | | C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING | | | ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT | | | OF THE STANDARD REFERENCE DESIGN BUILDING. | | | NO ENERGY CALCULATIONS WERE FOUND IN SUPPORTING | | | DOCUMENTS. | | | PLEASE UPLOAD THE ENERGY CALCULATIONS (LOAD | | | CALCULATIONS WERE PROVIDED) | | | | | | 10. SOME WALLTYPES ON FLOOR PLAN A-1.0.05 DON?T MATCH | | | WITH WALL TYPES LISTED ON A-6.0.00 | | | VERIFY ALL WALL TYPES TO MATCH | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-27 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-19 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2018-06-27 06:53:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B TABLES 705.2, 705.8, PROJECT DATA SHEET STATES | | | THAT THE DISTANCE TO OTHER STRUCTURES IS OVER 30'. | | | REVISE SITE PLAN TO SHOW DISTANCE TO ASSUMED PROPERTY | | | LINE BETWEEN THE PERGOLA, GAZEBO, OR IS INTENT TO | | | UTILIZE EXCEPTION (FBC B 705.2 EXCEPTION)? REVISE PLAN | | | TO SHOW COMPLIANCE. | | | | | | 2 A1.0.04, HOW OCCPUANT LOAD OF 106 WAS DETERMINED IS | | | NOT CLEAR. | | | | | | 3. FBC 109, VALUE IS TO INCLUDE ALL LABOR, MATERIALS, | | | OVERHEAD, PROFIT, DESIGN FEES; EVERYTHING EXCEPT FOR | | | LAND. SOME ITEMS ON THE PLAN ARE SHOWN "BY OWNER"; IF | | | THESE ITEMS ARE PERMANENTLY INSTALLED, THEY ARE TO BE | | | INCLUDED IN PERMIT VALUE. WHEN RESUBMITTING, PROVIDE | | | THE CORRECT VALUE AND PAY PLAN REVIEW FEES ON CORRECTED | | | VALUE. | | | | | | NOTE THAT REVIEWS BY ALL TRADES MAY NOT HAVE BEEN DONE | | | AT THIS TIME PENDING PAYMENT OF PLAN REVIEW FEES. | | | | | | 4. A5.0.00, ROOM FINISH WALLS FOR BATHROOMS ARE SHOWN | | | AS GYP/PAINT; SEE FBC B 1210.2.1, 1210.2.2, REVISE PLAN | | | TO SHOW COMPLIANCE. | | | | | | 5. A7.0.01 IS TOO LIGHT TO READ; PLEASE ADJUST, FBC | | | 107. | | | | | | 6. FBC 107, WILL THIS BUILDING BE SPRINKLERED? | | | CONFLICTING INFORMATION ON PLANS; SEE FIRE REVIEW. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-18 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-18 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-29 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-29 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-22 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-22 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2018-08-22 15:36:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PANEL PH1 SHOULD BE RATED FOR CORROSIVE ENVIRONMENT. | | | PROVIDE CORRECTION. NEC 110.28 | | | 2. PROVIDE PANEL SCHEDULE FOR PH1. WPB FBC 107.2.1; NEC | | | 210.19, 210.20, 215.2, 408.4 | | | 3. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, | | | 110.10 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-15 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-15 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2018-06-15 16:28:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. PLAN | | | REVIEW NOT COMPLETED AT THIS TIME. CONTRACTOR MUST | | | SUBMIT PROPER VALUE FOR LABOR AND MATERIALS AND PAY THE | | | PROPER PLAN REVIEW FEE PRIOR TO PLAN REVIEW. WPB FBC | | | 109.1, 109.2, 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
2018-12-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2018-12-11 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-27 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-27 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2018-06-27 06:54:10 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-02-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2019-02-28 13:29:39 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) FIRE SPRINKLER PROTECTION DOCUMENTS REMAIN WITH THIS | | | SUBMITTAL AND CONTRADICT THE RESPONSE COMMENTS | | | REAGARDING THE SYSTEM NOT BEING REQUIRED. | | | | | | IF FIRE PROTECTION IS NOT A PART OF THE SUBMITTAL THOSE | | | PALN SHEETS SHALL EITHER BE REMOVED/DELETED OR MARKED | | | NOT APPLICABLE IN SOME WAY ON A REVISION SUBMITTAL. | | | | | | PLEASE MAKE THE NECESSARY REVISONS TO THE FIRE | | | PROTECTION SHEETS PRIOR TO FINAL FIRE INSPECTIONS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2018-08-03 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-08-03 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-08-03 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2018-08-03 10:25:52 | THIS IS A DUPLICATE ENTRY. | | | PLAN REVIEWED AND FAILED ON 5/22/18 BY P. LEDUC. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-05-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-17 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2018-05-22 13:23:51 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET A 0.0.02 - THERE IS A NOTE, UNDER BUIOLDING | | | CODE DATA, INDICATING "TYPE VB NONSPRINKLERED" YET | | | THERE A FIRE PROTECTION DOCUMENTS SHOWING FIRE | | | SPRINKLERS. | | | | | | PLEASE CORRECT OR JUSTIFY. | | | | | | | | | | | | 2) SHEET A 0.0.02 - UNDER "PROJECTS COMPONENTS, | | | BUILDING OCCUPANCY" TABLE THERE ARE NO FIGURES ENTERED | | | INTO THE COLUMNS LABLED "FACTOR OR PERSONS". | | | | | | | | | PLEASE CORRECT | | | | | | | | | | | | 3) SHEET FP 0.0.00 - UNDER THE SECTION "FIRE PROTECTION | | | FLOW TEST DATA" THERE ARE NO FIGURES ENTERED INTO AREAS | | | INDICATED. THESE FIGURES ARE REQUIRED TO PROVIDE | | | ADAQUATE WATER SUPPLY AND SYSTEM DEMANDS. | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 4) SHEET FP 0.0.00 - UNDER THE SECTION " DESIGN | | | CRITERIA" STORAGE, MECH/ELECT. ROOMS, ORDINARY HAZARD | | | GRUOP 1 IS INDICATED. HOWEVER, ON SHEET FP 1.3.01 THERE | | | ARE NO HEASD INDICATED IN THE ELECTRICAL ROOM. | | | | | | PER NFPA 13 | | | | | | 8.15.11 ELECTRICAL EQUIPMENT. | | | 8.15.11.1 UNLESS THE REQUIREMENTS OF 8.15.11.3 ARE MET, | | | SPRINKLER | | | PROTECTION SHALL BE REQUIRED IN ELECTRICAL EQUIPMENT | | | ROOMS. | | | 8.15.11.2 HOODS OR SHIELDS INSTALLED TO PROTECT | | | IMPORTANT | | | ELECTRICAL EQUIPMENT FROM SPRINKLER DISCHARGE SHALL BE | | | NONCOMBUSTIBLE. | | | 8.15.11.3 SPRINKLERS SHALL NOT BE REQUIRED IN | | | ELECTRICAL EQUIPMENT | | | ROOMS WHERE ALL OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE ROOM IS DEDICATED TO ELECTRICAL EQUIPMENT ONLY. | | | (2) ONLY DRY-TYPE ELECTRICAL EQUIPMENT IS USED. | | | (3) EQUIPMENT IS INSTALLED IN A 2-HOUR FIRE-RATED | | | ENCLOSURE | | | INCLUDING PROTECTION FOR PENETRATIONS. | | | (4) NO COMBUSTIBLE STORAGE IS PERMITTED TO BE STORED IN | | | THE | | | ROOM. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | | | | 5) SHEET 1.3.01 - THERE APPEARS TO BE NO SPRINKLER HEAD | | | COVERAGE IN THE FRONT PORCH BAR AREA. | | | | | | PER NFPA 13 | | | | | | 8.15.1.2.18 SOFFITS, EAVES, OVERHANGS, AND DECORATIVE | | | FRAME | | | ELEMENTS. SPRINKLERS SHALL BE PERMITTED TO BE OMITTED | | | FROM | | | WITHIN COMBUSTIBLE SOFFITS, EAVES, OVERHANGS, AND | | | DECORATIVE | | | FRAME ELEMENTS THAT ARE CONSTRUCTED IN ACCORDANCE WITH | | | 8.15.1.2.18.1 THROUGH 8.15.1.2.18.4. | | | 8.15.1.2.18.1 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS, | | | AND DECORATIVE | | | FRAME ELEMENTS SHALL NOT EXCEED 4 FT 0 IN. (1.2 M) IN | | | WIDTH. | | | 8.15.1.2.18.2 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS, | | | AND DECORATIVE | | | FRAME ELEMENTS SHALL BE DRAFTSTOPPED, WITH A MATERIAL | | | EQUIVALENT TO THAT OF THE SOFFIT, INTO VOLUMES NOT | | | EXCEEDING 160 FT3 | | | (4.5 M3). | | | 8.15.1.2.18.3 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS, | | | AND DECORATIVE | | | FRAME ELEMENTS SHALL BE SEPARATED FROM THE INTERIOR OF | | | THE BUILDING BY WALLS OR ROOFS OF NONCOMBUSTIBLE OR | | | LIMITEDCOMBUSTIBLE | | | CONSTRUCTION. | | | 8.15.1.2.18.4 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS, | | | AND DECORATIVE | | | FRAME ELEMENTS SHALL HAVE NO OPENINGS OR UNPROTECTED | | | PENETRATIONS DIRECTLY INTO THE BUILDING. | | | | | | PLEASE REVIEW AND PROVIDE HEAD COVERAGE OR JUSTIFY WITH | | | SPECIFIC FIRE CODE DETAILS. | | | | | | | | | | | | 6) THERE ARE NO INDICATIONS OF HOW THIS FIRE SPRINKLER | | | SYSTEM WILL BE MONITORED AND WHERE THE FACP WILL BE | | | LOCATED. | | | | | | PLEASE REVIEW AND PROVIDE DETAILS. | | | | | | | | | | | | 7) THERE ARE NO INDICATIONS OF THE INSTALL OF THE | | | KITCHEN HOOD AND/OR FIRE SUPPRESSION SYSTEM. | | | | | | THE KITCHEN HOOD AND FIRE SUPPRESSION SHALL BE | | | SUBMITTED UNDER SEPARATE SHOP DRAWINGS EACH IN | | | COMPLIANCE WITH NFPA 96 & 2001. | | | | | | PLEASE PROVIDE AND APPLICABLE NOTE OF ACKNOWLEDGMENT | | | AND COMPLIANCE. | | | | | | | | | | | | 8) THERE IS A CHLORINE STORAGE ROOM THAT DOES APPEAR TO | | | BE PROTECTED PER THE REQUIREMENT. | | | | | | PER NFPA 101, CHAPTER 12 NEW ASSEMBLY OCCUPANCIES | | | | | | 12.3.2 PROTECTION FROM HAZARDS. | | | 12.3.2.1 SERVICE EQUIPMENT, HAZARDOUS OPERATIONS OR | | | PROCESSES, AND STORAGE FACILITIES. | | | 12.3.2.1.2 ROOMS OR SPACES FOR THE STORAGE, PROCESSING, | | | OR USE OF | | | MATERIALS SPECIFIED IN 12.3.2.1.2(1) THROUGH (3) SHALL | | | BE PROTECTED | | | IN ACCORDANCE WITH ONE OF THE FOLLOWING: | | | (1) SEPARATION FROM THE REMAINDER OF THE BUILDING BY | | | FIRE BARRIERS | | | HAVING A MINIMUM 1-HOUR FIRE RESISTANCE RATING OR | | | PROTECTION | | | OF SUCH ROOMS BY AUTOMATIC EXTINGUISHING SYSTEMS AS | | | SPECIFIED IN SECTION 8.7 IN THE FOLLOWING AREAS: | | | (C) ROOMS OR SPACES USED FOR THE STORAGE OF HAZARDOUS | | | MATERIALS OR FLAMMABLE OR COMBUSTIBLE LIQUIDS IN | | | QUANTITIES DEEMED HAZARDOUS BY RECOGNIZED STANDARDS | | | | | | PLEASE REVIEW AND CORRECT WITH SPECIFIC DETAILS. | | | | | | | | | 9) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 10) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-03-21 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-03-21 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2019-03-21 13:47:47 | GAS APPROVED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-27 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-27 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2018-12-27 16:14:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2012 | | | 5TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2014 5TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2014 5TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2014 5TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2014 5TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW | | | | | | GAS COMMEMTS: DENIED | | | | | | 1.THERE ARE TWO GAS RISERS SHTS P-3.1.01 AND P-3.3.00 | | | PLEASE CLARIFY PER WPB FBC 107.2.1 | | | NOTE: P-3.1.01 NATURAL GAS RISER DIAGRAM IS INCOMPLETE | | | AND THE CORRECTED DRAWING WITH CALCULATIONS ARE ON | | | P-3.3.00 | | | PLEASE CORRECT AND/ OR DELETE AS REQUIRED PER WPB FBC | | | 107.2.1 | | | 2. GAS EQUIPMENT ITEMS 2013 AND 2014 SPEC SHEET MBTU | | | REQUIREMENTS ARE GREATER THAN THAT CALLED OUT ON | | | P-3.3.00. PLEASE CORRECT AS NECESSARY PER WPB FBC | | | 107.2.1 | | | PROVIDE GAS EQUIPMENT SCHEDULE LISTING ITEMS 2011 | | | THROUGH 2014 WITH DESCRIPTION , GWH-1 W/DESCRIPTION AND | | | MBTU DEMAND FOR EACH. | | | 3. SPECIFY 2ND STAGE REGULATORS COMPLYING WITH ANSI | | | Z21.80 AND CALL OUT VENT ELIMINATORS OR VENTS AS | | | REQUIRED PER WPB FBC 107.2.1. IF VENTS ARE REQUIRED | | | SHOW ROUTING, SIZING AND TERMINATION WITH DETAIL ON THE | | | PLAN PER WPB FBC 107.2.1 | | | 4. 2ND REQUEST; SUBMIT CALCULATIONS FOR COMBUSTION AIR | | | PER THE FBC FG 304.1 | | | 5. SHOW LOCATION OF DIRECT VENT AND EXHAUST VENT | | | TERMINALS WHERE THEY PENETRATE THE EXTERIOR WALL ON THE | | | PLUMBING FLOOR PLAN P-1.3.03 IN ACCORDANCE WITH FBC FG | | | 502 THROUGH 505 PER WPB FBC 107.2.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-23 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-23 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2018-06-23 11:40:55 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | GAS COMMENTS: | | | | | | 1. THERE ARE TWO GAS RISERS SHTS P.3.1.00 AND P.3.2.00 | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE | | | THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER | | | PRESSURE THAN THE SUPPLY PRESSURE. LINE GAS PRESSURE | | | REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSI | | | Z21.80. ACCESS SHALL BE PROVIDED TO PRESSURE | | | REGULATORS. PRESSURE REGULATORS SHALL BE PROTECTED FROM | | | PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR | | | OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. PLEASE SHOW ON RISER ALONG WITH SHUT OFF | | | VALVES AND SEDIMENT TRAPS. FBC FG 410.1, 408.4, 409.1 | | | | | | 3. GAS NOTE #4 STATES 3" DIRECT VENT THE RISER SHOWS 2" | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | 5. SUBMIT A DETAIL SHOWING THE TYPE OF VENT, LOCATION, | | | SIZE, TERMINATION POINT, HEIGHT ABOVE THE ROOF AND | | | ANCHORING DETAILS OF THE GAS VENT(S) PER 2017 FBC-FUEL | | | GAS SECS. 502 THRU 505 OR 2017 FBC-RES. SEC.G2426 | | | THROUGH G2439. | | | | | | 6. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT AND | | | REGULATORS TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FGC SEC.305.1, FBC-RES. | | | SEC.G2408.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-22 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-06 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-19 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-01-02 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-10-29 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-09-11 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-05-08 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-01-05 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-01-05 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2021-01-05 10:13:30 | OK PER EMAIL FROM WILLIE SWOOPE | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-12-21 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-12-21 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2020-12-21 11:58:26 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-06 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-06 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2019-04-06 07:16:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-19 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-19 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2018-06-19 06:44:57 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES DUE, IF APPLICABLE, PROVIDED. | | | | | | AFTER ALL OTHER REVIEWS HAVE PASSED, PRINT OUT ONE SET | | | OF PLANS TO TAKE TO THE COUNTY. | | | | | | 561-233-5025 FOR MORE INFORMATION | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-26 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-26 |
Time |
10:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-11-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-26 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-26 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2018-11-26 14:42:36 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18050277 | | | 11/26/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A-1.0.05, A-2.0.02, A-5.0.01, A-6.0.00, & M-1.3.01: | | | THE EXTERIOR DOORS AND INTERIOR DOORS ENCLOSING THE | | | POOL EQUIPMENT STORAGE AND ELECTRICAL ROOMS SHALL BE | | | FIRE-RATED PER SECTION 707.6 FBC B. ( CORRECTED | | | ARCHITECTURAL PLANS NOW SHOW THE EXTERIOR WALLS TO BE | | | 3HR FIRE-RATED). FIRE DAMPERS SHALL BE PROVIDED FOR THE | | | MAKEUP AIR LOUVERS ON THE EAST WALLS, AND FOR THE AC-1 | | | OUTDOOR AIR INTAKE LOUVER, THE FOOD PREP EXHAUST | | | OUTLET, AND THE EXHAUST HOOD MAKEUP AIR INLET- SECTION | | | 607.5.2 FBC M. | | | | | | 2) SHEET M-1.3.01: THE STAINLESS STEEL EXHAUST DUCKWORK | | | IN THE POOL EQUIPMENT STORAGE ROOM IS NOT IN COMPLIANCE | | | WITH SECTION 510.9 FBC M WHICH REQUIRES THE DUCT TO BE | | | G90 GALVANIZED OR NON-METALLIC MATERIALS THAT EXHIBIT A | | | FLAME SPREAD/SMOKE-DEVELOPED INDEX OF 25/50. | | | | | | 3) M-1.3.01: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | | EF-1 WITH AN APPROVAL STAMP BY THE ENGINEER OF RECORD. | | | THE SPECS SHALL INDICATE THE FAN HAS BEEN TESTED FOR | | | USE IN CONVEYING CORROSIVE OR HAZARDOUS EXHAUST FUMES- | | | SECTION 304.1 FBC M. A) CLARIFY THE LOCATION OF THE | | | FAN- ABOVE OR BELOW THE CEILING. IF LOCATED ABOVE THE | | | CEILING PROVIDE AN ACCESS PANEL FOR SERVICE AND | | | REPLACEMENT- SECTION 306.1 FBC M. | | | | | | 4) A-2.0.02 & M-1.3.01: AS INDICATED BY NOTE #6 ON | | | M-1.3.01 PLEASE SHOW THE EXACT LOCATION OF THE EF-1 | | | EXHAUST OUTLET TO VERIFY COMPLIANCE WITH SECTION | | | 501.3.1(2) FBC M. (PLEASE NOTE THIS OUTLET SHALL NOT BE | | | PROTECTED WITH A FIRE DAMPER- SECTION 510.6.7 FBC M). | | | | | | 5) M-1.3.01: COMMENT #3(E) FROM THE 1ST TREVIEW STILL | | | EXISTS- PLEASE SUBMIT SPECS FOR THE CHEMICAL TANKS IN | | | THE POOL EQUIPMENT STORAGE ROOM. | | | | | | 6) COMMENT #2 FROM THE 1ST REVIEW REQUESTING EVIDENCE | | | OF ENERGY EFFICIENCY COMPLIANCE WAS NOT ADDRESSED- THE | | | PROPOSED BUILDING SHALL BE IN COMPLIANCE WITH THE FBC | | | EC. REFER TO SECTIONS C101.2 -SCOPE AND C401.2 | | | APPLICATION (COMPLIANCE PATHS). PROVIDE A COMPLIANCE | | | SUBMITTAL C101.5.1- COMPLIANCE MATERIALS. | | | | | | 7) COMMENT #6 FROM THE 1ST REVIEW STILL EXISTS. IF THE | | | REQUESTED WIND LOAD ENGINEERING IS TO BE A DEFERRED | | | SUBMITTAL PLEASE INDICATE THAT ON THE CORRECTED PLANS, | | | OR IN THE RESPONSE NARRATIVE. | | | | | | 8) COMMENT #8 FROM THE 1ST REVIEW HAS NOT BEEN | | | COMPLETELY ADDRESSED. WHEN USING A MECHANICAL | | | VENTILATION SYSTEM TO PROVIDE COMBUSTION AIR, THE | | | SYSTEM SHALL PROVIDE THE SPECIFIED COMBUSTION RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR- SECTION | | | 304.9.3 FBC FG. BASED ON THE AIR BALANCE CALCULATION ON | | | M-1.3.01, IT APPEARS THAT ALL VENTILATION AIR FROM AC-1 | | | WILL BE UTILIZED AS MAKEUP AIR FOR THE EXHAUST SYSTEMS. | | | | | | 9) M-1.3.01: THE LOCATION OF THE MAKEUP AIR OPENING FOR | | | THE EXHAUST HOOD SHALL BE A MINIMUM 3' AWAY FROM THE | | | FOOD PREP EXHAUST OUTLET- SECTION 501.3.1 (3) FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-06-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-11 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-11 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2018-06-11 12:01:18 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18050277 | | | 6/11/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SEPARATE PERMITS ARE REQUIRED FOR THE COMMERCIAL | | | KITCHEN HOOD, THE FIRE SUPRESSION SYSTEM, AND THE | | | WALKIN FOOD STORAGE AND KEG COOLERS. PLEASE PLACE | | | ADVISORY NOTES ON THE PLANS. | | | | | | 2) THE PROPOSED BUILDING SHALL BE IN COMPLIANCE WITH | | | THE FBC EC. REFER TO SECTIONS C101.2 -SCOPE AND C401.2 | | | APPLICATION (COMPLIANCE PATHS). PROVIDE A COMPLIANCE | | | SUBMITTAL C101.5.1- COMPLIANCE MATERIALS, | | | | | | 2) SHEET M-1.3.01: PROVIDE EXHAUST VENTILATION | | | CALCULATIONS FOR THE TOILET ROOMS, AND THE POOL | | | EQUIPMENT AND CHEMICAL STORAGE ROOMS- TABLE 403.3.1 AND | | | SECTION 510.2. FBC M | | | | | | 3) M-1.3.01, POOL EQP/STORAGE ROOM: A) INDICATE HOW | | | MAKEUP AIR IS BEING PROVIDED TO THE ROOM- SECTION | | | 510.6.5 FBC M B) CLARIFY HOW THE SYSTEM WILL OPERATE- | | | CONTINUOUSLY OR INTERMITTENTLY. C) INDICATE THE TYPE OF | | | EXHAUST DUCTWORK TO BE INSTALLED- SECTION 510.9. D) THE | | | EXHAUST OUTLET APPEARS TO BE WITHIN 10' OF THE DOORS TO | | | THE ROOM AND NOT IN COMPLIANCE WITH SECTION 501.3.1(2) | | | FBC M. SHOW ALL REQUIRED CLEARANCE DISTANCE | | | MEASUREMENTS ON THE PLAN. E) SUBMIT SPECIFICATIONS FOR | | | THE CHEMICAL STORAGE TANKS AND EMBOLDEN THE PRINT ON | | | THE TANK SYSMBOLS TO CLEARLY SHOW THE CHEMICAL NAME AND | | | GALLON CONTENT- TABLE 414.2.5(1) FBC B. | | | | | | 4) M-0.0.01: PROVIDE AIR BALANCE CALCULATIONS FOR THE | | | KITCHEN- SECTION 508.1.2 FBC M | | | | | | 5) M-1.3.01: PROVIDE A DUCT SMOKE DETECTOR ON THE | | | SUPPLY TRUNK OF AC-1- SECTION 606.2.1 | | | | | | 6) M-1.3.01: PROVIDE WIND LOAD ENGINEERING FOR | | | INSTALLATION OF CU-1 & CU-2- SECTION 301.15 FBC M. | | | | | | 7) K-1.4: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL | | | GAS-FIRED COOKING EQUIPMENT- SECTION 623.1 FBC FG. | | | | | | 8) M-0.0.01: PROVIDE COMBUSTION AIR CALCULATIONS FOR | | | THE GAS-FIRED COOKING APPLIANCES- SECTION 304 FBC FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-16 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-13 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-03-21 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-03-21 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2019-03-21 13:59:37 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 3RD REVIEW | | | PLUMBING COMMEMTS: DENIED | | | 1. RE: A-0.0.02; REVISE FIXTURE BREAKDOWN TO REFLECT | | | 2017 FBC PL 403 AS REQUIRED BY WPB FBC 107.2.1. ARCH | | | A-0.0.02 STILL NOT CORRECTED. | | | 2. RE: A-2.0.03; ALL REFERENCE TO 2014 CODES SHALL BE | | | REVISED TO READ 2017 PER WPB FBC 107.2.1. PLUMBING | | | P0.0.00 OK; ARCH A2.0.03 STILL NOT CORRECTED. ADDED | | | 8/22//2019, PER CONVERSATION WITH STACEY, REFERENCE ON | | | A-2.0.03 WAS NOT FOUND. CORRECTION WAS MADE ON A-.0.01. | | | IF UPON REVIEW OF RESUBMITTED PLANS, THE REFERENCE IS | | | STILL FOUND WE WILL REDLINE IT ON THE PLANS TO CONFORM. | | | 3. RE: P-3.0.00; SANITARY PIPING FROM TOILET ROOM | | | TOILET BATTERY SHALL NOT DISCHARGE INTO THE COMBINATION | | | WASTE AND VENT BRANCH PER FBC PL 915.1. CONNECT AT A | | | POINT DOWNSTREAM OF THE COMBINATION WASTE AND VENT | | | BRANCH. P-1.3.1.01 FLOOR PLAN HAS BEEN CORRECTED BUT | | | P-3.0.00 RISER DIAGRAM HAS NOT. PLEASE CORRECT PER WPB | | | FBC 107.2.1. | | | 4. RE: P-3.1.00; PER WPB FBC 107.2.1 PLEASE PROVIDE | | | CALULATIONS FOR SIZING OF GREASY WASTE SYSTEM. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-27 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-20 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2018-12-27 14:20:02 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2012 | | | 5TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2014 5TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2014 5TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2014 5TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2014 5TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW | | | | | | PLUMBING COMMEMTS: DENIED | | | | | | | | | 1. RE: A-0.0.02; REVISE FIXTURE BREAKDOWN TO REFLECT | | | 2017 FBC PL 403 AS REQUIRED BY WPB FBC 107.2.1 | | | 2. 2ND REQUEST; A-0.0.02 THE PLUMBING FIXTURE BREAKDOWN | | | IS LISTED FOR THE TENNIS CLUB HOUSE PLEASE PROVIDE A | | | BREAKDOWN FOR THE WATERSIDE BAR, THE POOL AND | | | SURROUNDING AREA ALONG WITH A SITE PLAN THAT SHOWS THE | | | OCCUPANT LOAD FOR EACH AREA. THE FIXTURE COUNT SHALL | | | COMPLY WITH FBC PL TABLE 403.1 ADDITION INFORMATION | | | REQUIRED PER WPB FBC 107.2.1 NOTE; ARCHITECT DID NOT | | | ADDRESS CONCERNS FOR THE POOL AND SURROUNDING AREAS AS | | | REQUESTED. | | | 3. RE: A-2.0.03; ALL REFERENCE TO 2014 CODES SHALL BE | | | REVISED TO READ 2017 PER WPB FBC 107.2.1 | | | 4. 2ND REQUEST: | | | RE: P-0.0.00; THE PLUMBING SPEC UNDER THE PIPE HANGER | | | SPACING SCHEDULE SHALL COMPLY WITH FBC PL TABLE 308.5. | | | GIVE EXTRA CONSIDERATION TO COPPER TUBING. | | | 5. 2ND REQUEST: RE; P-0.0.01 + P-3.3.00 THE SCHEDULE | | | FOR THE WATER HEATER, EXPANSION TANK AND RECIRCULATION | | | PUMP DO NOT MATCH PLEASE CLARIFY AND PROVIDE | | | MANUFACTURE SPECIFICATION. PER WPB AMEND TO FBC 107.2.1 | | | SEE FOLLOWING AND CLARIFY PER WPB FBC 107.2.1 | | | A. EXPANSION TANK P-0.0.00=ET-1, P-3.3.00 & | | | P-3.4.00=EX-1. | | | B. SCHEDULES FOR HOT WATER RECIRCULATING PUMP(S) ON | | | P-3.4.00 AND P-0.0.00 DO NOT MATCH. | | | C. SCHEDULES FOR GAS WATER HEATER ON P-3.4.00 AND | | | P-0.0.00 DO NOT MATCH. | | | D. SCHEDULES FOR MIXING VALVE ON P-3.4.00 AND P-0.0.00 | | | DO NOT MATCH. | | | 6. 2ND REQUEST: PLEASE SHOW TRAP PRIMERS ON THE FLOOR | | | DRAIN ON THE ISOMETRIC DRAWING. PER FBC PL 1002.4.1 | | | IN LIEU OF SHOWING THE TRAP PRIMERS PROVIDE A NOTE ON | | | P-3.0.00 RISER DIAGRAM STATING ?PROVIDE TRAP PRIMERS | | | FOR ALL FLOOR DRAINS; SEE P-4.1.00, DETAILS 5 & 6? | | | 7. IT APPEARS THAT THE ORIGINAL DOMESTIC WATER RISER | | | DIAGRAM P-3.1.00 NOW CONTAINS THE GREASY WASTE | | | ISOMETRIC AND GREASE INTERCEPTOR CALCULATIONS. | | | A. 2ND REQUEST: ON THE WATER ISOMETRIC PLEASE SIZE THE | | | BRANCH PIPING FOR THE GANG BATHROOMS. 107.3.5.1.3(13) | | | OK. SHOWN ON P-3.2.00 (SEE NOTES BELOW CONCERNING | | | CONFUSION OF PDF TITLES) | | | B. 2ND REQUEST; PLEASE PROVIDE PIPING DETAILS FOR THE | | | WATER FILTERS BNB-2, BNB-2.1 AND 2015.1. | | | 107.3.5.1.3(13) | | | C. 2ND REQUEST; PLEASE PROVIDE BACKFLOW DEVICES FOR THE | | | WATER FILTER, ICE MACHINE, BEVERAGE DISPENSERS AND | | | COFFEE MAKERS. PER FBC PL 608.3 , 608.16.1, 608.16.10 | | | NOTE 3 ON P-1.3.03 DOES NOT SEEM TO ADDRESS THIS ISSUE. | | | D. TO SUMMARIZE, WATER RISER ISOMETRIC FOR THE PROJECT | | | SHALL SHOW ALL REQUIRED VALVES, BACKFLOW PREVENTERS, | | | WATER HAMMER ARRESTORS AND OTHER PERTINENT DEVICES PER | | | WPB FBC 107.2.1 | | | ADDITIONAL COMMENTS | | | 1 .RE: P-3.0.00; SANITARY PIPING FROM TOILET ROOM | | | TOILET BATTERY SHALL NOT DISCHARGE INTO THE COMBINATION | | | WASTE AND VENT BRANCH PER FBC PL 915.1. CONNECT AT A | | | POINT DOWNSTREAM OF THE COMBINATION WASTE AND VENT | | | BRANCH. CORRECT ON P-1.3.01 TO REFLECT THE SAME. | | | 2. RE: P-0.0.01; FIXTURE SCHEDULE L-1 AND L-2, CALL FOR | | | TMV PER FBC 416.5 AND SPECIFY PER WPB WPC 107.2.1 | | | 3. RE: P-4.1.00; DETAIL FOR SENSOR FAUCET CONNECTION, | | | SPECIFY TMV PER WPB WPC 107.2.1 | | | 4. RE: P-4.0.00; DETAILS 5 & 6 FLUSHING FLOOR DRAINS. | | | WHERE ARE THESE BEING USED? SHOW ON FLOOR PLAN AND | | | SCHEDULE, SPECIFY CODE COMPLIANT FLUSH VALVE. IF NOT | | | PART OF PROJECT THEN DELETE THE DETAILS. WPB FBC | | | 107.2.1 | | | 5. RE: P-3.3.00, P-3.4.00; WATER HEATER DETAILS ARE | | | CONFLICTING. RECONCILE THE DETAILS TO MATCH EACH OTHER | | | PER WPB FBC 107.2.1. PLEASE NOTE THE SCHEMATIC DETAIL | | | #1 ON P-3.4.00 IS CONFUSING. THE ISOMETRIC DETAIL #2 ON | | | P-3.4.00 IS VERY BUSY AND THERE ARE A NUMBER OF ENDS | | | THAT ARE NOT IDENTIFIED. DIFFERENT DETAILS HAVE | | | DIFFERENT QUANTITIY OF HOT WATER RECIRCULATION PUMPS. | | | THERE IS DIFFERENT INFO FOR EXPANSION TANK. | | | THE VENTING AND COMBUSTION AIR FOR THE WATER HEATER IS | | | DIFFERENT IN DIFFERENT DETAILS. | | | SPECIAL NOTES: | | | P-3.3.00 ENLARGED WATER HEATING SYSTEM IS ACTUALLY THE | | | PLUMBING NATURAL GAS RISER DIAGRAM | | | P-3.2.00 NATURAL GAS RISER DIAGRAM IS ACTUALLY THE | | | PLUMBING DOMESTIC WATER RISER DIAGRAM | | | P-3.1.00 PLUMBING DOMESTIC WATER RISER DIAGRAM IS | | | ACTUALLY THE PLUMBING GREASE WASTE DRAINAGE RISER | | | DIAGRAM | | | P-3.1.01 NATURAL GAS RISER DIAGRAM IS INCOMPLETE AND | | | THE CORRECTED DRAWING AND CALCULATIONS ARE ON P-3.3.00 | | | PLEASE CORRECT AND OR DELETE AS REQUIRED PER WPB FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-23 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-22 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2018-06-23 11:14:33 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A.0.0.02 THE PLUMBING FIXTURE BREAKDOWN IS | | | LISTED FOR THE TENNIS CLUB HOUSE PLEASE PROVIDE A | | | BREAKDOWN FOR THE WATERSIDE BAR, THE POOL AND | | | SURROUNDING AREA ALONG WITH A SITE PLAN THAT SHOWS THE | | | OCCUPANT LOAD FOR EACH AREA. THE FIXTURE COUNT SHALL | | | COMPLY WITH FBC PL TABLE 403.1 ADDITION INFORMATION | | | REQUIRED PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT. A.2.0.03 SHOW CLEAR FLOOR SPACE FOR ACCESSIBLE | | | TOILETS AND SHOW DIMENSIONS ON ALL ACCESSIBLE CLEAR | | | FLOOR FOR ALL FIXTURES. PER WPB AMEND TO FBC 107.2.1 | | | FBC ACC 604.3.1, 602.2, 605.3, 606.2 | | | | | | 3. SHT. A.7.0.01 THE DIMENSIONS ON THE DETAILS ARE | | | EXTREMELY LIGHT AND HARD TO READ PLEASE DARKEN ALL | | | DIMENSIONS. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. SHT. P.0.0.00 THE PLUMBING SPEC 1.2, 1.6, 4.1 SHALL | | | REFLECT THE CURRENT CODE FBC PL 2017 6TH EDITION | | | | | | 5. SHT. P.0.0.00 THE PLUMBING SPEC UNDER THE PIPE | | | HANGER SPACING SCHEDULE SHALL COMPLY WITH FBC PL TABLE | | | 308.5 | | | | | | 6. PROVIDE A SITE PLAN SHOWING THE GREASE INTERCEPTOR | | | AND PIPING DETAIL. PER WPB AMEND TO FBC 107.2.1, | | | 107.3.5.1.3(11) | | | | | | 7. PROVIDE SIZING CALCULATION FOR THE GREASE | | | INTERCEPTOR. PER WPB AMEND TO FBC 107.2.1, | | | 107.3.5.1.3(11) | | | | | | 8. SHT. P.0.0.01 + P.3.3.00 THE SCHEDULE FOR THE WATER | | | HEATER, EXPANSION TANK AND RECIRCULATION PUMP DO NOT | | | MATCH PLEASE CLARIFY AND PROVIDE MANUFACTURE | | | SPECIFICATION. PER WPB AMEND TO FBC 107.2.1 | | | | | | 9. SHT. P.3.3.00 DETAILS #3 + 35 APPEAR TO BE DIFFERENT | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 10. PLEASE EXPAND THE SANITARY ISOMETRIC AND SEPARATE | | | THE SANITARY FROM THE GREASE. 107.3.5.1.3(13) | | | | | | 11. PLEASE SHOW TRAP PRIMERS ON THE FLOOR DRAIN ON THE | | | ISOMETRIC DRAWING. PER FBC PL 1002.4.1 | | | | | | 12. THE PLUMBING FIXTURES IN THE BAR AREA SHALL ALSO | | | DISCHARGE TO THE GREASE SYSTEM. PER FBC 1003.3.1 AND | | | WEST PALM BEACH, FLORIDA - CODE OF ORDINANCES SEC. | | | 90-125.(7) SEC. 90-126.(7) | | | | | | 13. THE HAND SINK IN THE KITCHEN DOES NOT APPEAR TO BE | | | ON THE ISOMETRIC PLEASE CLARIFY. 107.3.5.1.3(13) | | | | | | 14. ON THE WATER ISOMETRIC PLEASE SIZE THE BRANCH | | | PIPING FOR THE GANG BATHROOMS. 107.3.5.1.3(13) | | | | | | 15. PLEASE PROVIDE PIPING DETAILS FOR THE WATER FILTERS | | | BNB-2, BNB-2.1 AND 2015.1. 107.3.5.1.3(13) | | | | | | 16. PLEASE PROVIDE BACKFLOW DEVISES FOR THE WATER | | | FILTER, ICE MACHINE, BEVERAGE DISPENSERS AND COFFEE | | | MAKERS. PER FBC PL 608.3 , 608.16.1, 608.16.10 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-22 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2019-03-22 08:52:47 | PROVIDE ROOFING PRODUCT APPROVALS WITH SUB PERMIT. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-17 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-17 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-22 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2019-03-26 10:56:05 | MECH SHEETS GOOD. | | 2019-03-18 13:37:11 | ELECTRICAL SHEETS OK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-13 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-12 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2018-12-13 13:25:31 | NEW SHEETS WILL NEED TO BE REVIEWED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-19 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-19 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2018-06-19 06:51:48 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DIGITAL SIGNATURES/SEALS (PLAN PAGES) ARE IN | | | ACCORDANCE WITH FS 471, FS 481 AS NOTED. NEW SHEETS | | | SUBMITTED IN THE NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. LOAD CALCS S&S (IN SUPPORTING DOCUMENTS FOLDER) IS | | | NOT DIGITALLY SIGNED AND SEALED. | | | | | | 3. STRUCTURAL CALCS (IN SUPPORTING DOCUMENTS FOLDER) OK | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-04-03 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-04-03 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2019-04-03 16:06:37 | PROVISOS: | | | | | | 1. THE SCOPE OF THIS PERMIT REVIEW IS LIMITED TO THE | | | ?WATER SIDE BAR.? SEPARATE PERMITS REQUIRED FOR | | | FENCING, LANDSCAPING, IRRIGATION, ETC. | | | | | | 2. THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED | | | DEVELOPMENT SHALL BE SUBJECT TO ALL DEVELOPMENT ORDER | | | CONDITIONS AND DESIGN GUIDELINES, AS OUTLINED IN | | | RESOLUTION NO. 307-17, APPROVED ON NOVEMBER 20, 2017, | | | AND AS MAY BE AMENDED. | | | _______________________________________________________ | | | _____________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-11-29 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-11-29 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2018-11-29 15:53:35 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.10.2018 | | | PERMIT NO.: 18050277 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THESE MODIFICATIONS WILL REQUIRE A MINOR AMENDMENT | | | TO THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED | | | DEVELOPMENT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-10 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-09-10 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-09-10 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2018-09-10 11:09:25 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.10.2018 | | | PERMIT NO.: 18050277 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO MEETINGS WITH THE DEVELOPER, ARCHITECT, | | | ETC. ON 9/4 /AND 9/7, DETAILS ARE TO BE PROVIDED | | | REGARDING THE REAR OF THE PROPOSED STRUCTURE, THE | | | SCREENING OF EQUIPMENT, ENHANCEMENT OF ARCHITECTURE, | | | ETC. THESE MODIFICATIONS WILL REQUIRE A MINOR AMENDMENT | | | TO THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED | | | DEVELOPMENT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|