Plan Review Details - Permit 18050277
Plan Review Stops For Permit 18050277
Review Stop AD ADDRESSING
Rev No 4 Status P Date 2020-02-24 Cont ID  
Sent By cpuell Date 2020-02-24 Time 13:28 Rev Time 0.00
Received By cpuell Date 2020-02-19 Time 13:28 Sent To  
Notes
2020-02-19 13:29:20ADDRESS STABLISHED AS 2022 BANYAN RESORT WAY BY MORIO &
 SHILL

Review Stop AD ADDRESSING
Rev No 3 Status P Date 2019-03-22 Cont ID  
Sent By dbattles Date 2019-03-22 Time 08:38 Rev Time 0.00
Received By dbattles Date 2019-03-22 Time 08:38 Sent To  
Notes
2019-03-22 08:39:05ADDRESS UPDATED
 2020 BANYAN RESORT WAY

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2019-01-14 Cont ID  
Sent By dbattles Date 2019-01-14 Time 09:56 Rev Time 0.00
Received By dbattles Date 2018-12-13 Time 13:21 Sent To  
Notes
2018-12-13 13:21:341. AN ADDRESS WILL NEED TO BE ESTABLISHED FOR THIS
 STRUCTURE.
 PLEASE CALL MICHAEL ORIO BY PHONE AT 561-494-1080, OR
 BY E-MAIL [email protected]
  
 2. UPON ADDRESS ASSIGNMENT, PLEASE UPLOAD COVER SHEET
 WITH NEW ADDRESS ON IT.
  
 COMMENT BY:
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
 COMMERCIAL BUILDING INSPECTOR BN7557
  
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2018-06-20 Cont ID  
Sent By shill Date 2018-06-20 Time 13:11 Rev Time 0.00
Received By shill Date 2018-06-20 Time 13:11 Sent To  
Notes
2018-06-20 13:14:40ADDRESS ON THE PLAN IS NOT IN OUR RECORDS (1998
 LACELEAF COURT).
  
 CONTACT:
  
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-09-17 Cont ID  
Sent By dbattles Date 2019-09-17 Time 07:42 Rev Time 0.00
Received By dbattles Date 2019-09-17 Time 07:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-03-22 Cont ID  
Sent By dbattles Date 2019-03-22 Time 08:57 Rev Time 0.00
Received By dbattles Date 2019-03-22 Time 08:41 Sent To  
Notes
2019-03-22 08:56:15PROVISOS:
 1) SUBMITTAL FOR ALL FENESTRATION (WINDOW, DOORS,
 LOUVERS)
 2) ROOFING PRODUCT APPROVALS SUBMITTED WITH SUB PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-12-13 Cont ID  
Sent By dbattles Date 2018-12-13 Time 13:21 Rev Time 0.00
Received By dbattles Date 2018-12-12 Time 12:47 Sent To  
Notes
2019-01-14 10:10:07UPON ADDRESS ASSIGNMENT, PLEASE UPLOAD COVER SHEET WITH
 NEW ADDRESS ON IT.
  
 COMMENT BY:
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
 COMMERCIAL BUILDING INSPECTOR BN7557
  
2018-12-13 13:24:56****CORRECTIONS****
 W.P.B. PERMIT: 18050277
  
 1ST REVIEW
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 2ND REVIEW: DECEMBER 12, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. OK
  
 2 A1.0.04, HOW OCCPUANT LOAD OF 106 WAS DETERMINED IS
 NOT CLEAR.
 2ND REVIEW:
 A) 2-2 SHEET A-0.0.02 BUILDING OCCUPANY TABLE DOESN?T
 MATCH OCCUPANT LOAD TABLE 1004.1.2.
 B) REQUIRED FIXTURE TABLE STATES A-3 OCCUPANCY, BUT IT
 SHOULD BE A-2. PLEASE ADJUST TO MATCH BUILDING CODE
 DATA.
 C) OCCUPANCY USED FOR REQUIRED FIXTURES SHOULD MATCH
 THE BUILDING OCCUPANCY CURRENTLY IT SAY 166 PERSONS FOR
 PLUMBING COUNT AND 106 FOR BUILDING OCCUPANCY.
 D) THE AMOUNT OF FIXTURES PROVIDED DOESN?T MATCH WHAT
 SHOWS IN PLAN VIEW ON SHEET A-1.0.05 AND PLUMBING
 SHEETS.
 PLEASE MATCH NUMBERS OF FIXTURE PROVIDED.
 E) REVIEW BUILDING OCCUPANCY AND USE FUNCTIONS FROM
 TABLE 1004.1.2 TO DETERMINE THE OCCUPANT LOAD [FBC
 1004.6]MULTIPLE OCCUPANCIES
 EXAMPLE:
 A) 200 GROSS - KITCHENS COMMERCIAL I SEE THE INTERIOR
 COMMERCIAL KITCHEN AS APPROX. 400 SQ. PLUS THE OUTSIDE
 SERVING CAN BE INCLUDED.
 B) 300 GROSS ? STORAGE. THE SECTION BEHIND THE KITCHEN
 IS ABOUT 1574 SQ. FT
  
 C) 15 GROSS ? UNCONCENTRATED TABLES AND CHAIRS. THE
 OUTSIDE EATING CAN BE JUST THE AREA FROM BARS EDGE TO
 ROOFS EDGE.
 PLEASE UPDATE SO AREAS ARE CLEAR
 SQ. FOOTAGE UNDER AIR, SQ. FOOTAGE FOR OUTDOOR EATING
 AND TOTAL SQ. FOOTAGE.
  
 3. OK
  
 4. OK
  
 5. OK
  
 6. OK
  
 NEW COMMENTS:
 7. REMOVE SHEET AGA A-1.0.0.01 SITE PLAN SINCE SHEET
 AGA A.0.0.05 IS THE APPROVED SITE PLAN. SHEETS AGA
 A1.0.02 AND AGA A1.0.03 MAY NOT BE NEEDED IN THE SET
 EITHER.
  
 8. SHEET A-1.0.04 INFORMATION ON SHEET IS NOT SHOWING
 UP. PLEASE RE-LOAD THE SHEET WITH INTENDED CONTENT.
  
 9. [FBC ENERGY C401.2]APPLICATION.
 COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE
 FOLLOWING:
 1.THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, EXCLUDING
 SECTION 9.4.1.1(G) OF THE STANDARD.
 2.THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN
 ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH
 SECTION C406 AND TENANT SPACES SHALL COMPLY WITH
 SECTION C406.1.1.
 3.THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404,
 C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING
 ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT
 OF THE STANDARD REFERENCE DESIGN BUILDING.
 NO ENERGY CALCULATIONS WERE FOUND IN SUPPORTING
 DOCUMENTS.
 PLEASE UPLOAD THE ENERGY CALCULATIONS (LOAD
 CALCULATIONS WERE PROVIDED)
  
 10. SOME WALLTYPES ON FLOOR PLAN A-1.0.05 DON?T MATCH
 WITH WALL TYPES LISTED ON A-6.0.00
 VERIFY ALL WALL TYPES TO MATCH
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-27 Cont ID  
Sent By shill Date 2018-06-27 Time 06:53 Rev Time 0.00
Received By shill Date 2018-06-19 Time 06:43 Sent To  
Notes
2018-06-27 06:53:20****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC B TABLES 705.2, 705.8, PROJECT DATA SHEET STATES
 THAT THE DISTANCE TO OTHER STRUCTURES IS OVER 30'.
 REVISE SITE PLAN TO SHOW DISTANCE TO ASSUMED PROPERTY
 LINE BETWEEN THE PERGOLA, GAZEBO, OR IS INTENT TO
 UTILIZE EXCEPTION (FBC B 705.2 EXCEPTION)? REVISE PLAN
 TO SHOW COMPLIANCE.
  
 2 A1.0.04, HOW OCCPUANT LOAD OF 106 WAS DETERMINED IS
 NOT CLEAR.
  
 3. FBC 109, VALUE IS TO INCLUDE ALL LABOR, MATERIALS,
 OVERHEAD, PROFIT, DESIGN FEES; EVERYTHING EXCEPT FOR
 LAND. SOME ITEMS ON THE PLAN ARE SHOWN "BY OWNER"; IF
 THESE ITEMS ARE PERMANENTLY INSTALLED, THEY ARE TO BE
 INCLUDED IN PERMIT VALUE. WHEN RESUBMITTING, PROVIDE
 THE CORRECT VALUE AND PAY PLAN REVIEW FEES ON CORRECTED
 VALUE.
  
 NOTE THAT REVIEWS BY ALL TRADES MAY NOT HAVE BEEN DONE
 AT THIS TIME PENDING PAYMENT OF PLAN REVIEW FEES.
  
 4. A5.0.00, ROOM FINISH WALLS FOR BATHROOMS ARE SHOWN
 AS GYP/PAINT; SEE FBC B 1210.2.1, 1210.2.2, REVISE PLAN
 TO SHOW COMPLIANCE.
  
 5. A7.0.01 IS TOO LIGHT TO READ; PLEASE ADJUST, FBC
 107.
  
 6. FBC 107, WILL THIS BUILDING BE SPRINKLERED?
 CONFLICTING INFORMATION ON PLANS; SEE FIRE REVIEW.
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2019-03-18 Cont ID  
Sent By jpearson Date 2019-03-18 Time 15:09 Rev Time 0.00
Received By jpearson Date 2019-03-18 Time 13:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-11-29 Cont ID  
Sent By jpearson Date 2018-11-29 Time 13:17 Rev Time 0.00
Received By jpearson Date 2018-11-29 Time 13:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-08-22 Cont ID  
Sent By jpearson Date 2018-08-22 Time 15:36 Rev Time 0.00
Received By jpearson Date 2018-08-22 Time 15:36 Sent To  
Notes
2018-08-22 15:36:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PANEL PH1 SHOULD BE RATED FOR CORROSIVE ENVIRONMENT.
 PROVIDE CORRECTION. NEC 110.28
 2. PROVIDE PANEL SCHEDULE FOR PH1. WPB FBC 107.2.1; NEC
 210.19, 210.20, 215.2, 408.4
 3. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES
 EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN
 RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2
 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL TO CONFIRM THE STATED AIC RATING OF THE SERVICE
 EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9,
 110.10
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-06-15 Cont ID  
Sent By jpearson Date 2018-06-15 Time 16:39 Rev Time 0.00
Received By jpearson Date 2018-06-15 Time 16:39 Sent To  
Notes
2018-06-15 16:28:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. PLAN
 REVIEW NOT COMPLETED AT THIS TIME. CONTRACTOR MUST
 SUBMIT PROPER VALUE FOR LABOR AND MATERIALS AND PAY THE
 PROPER PLAN REVIEW FEE PRIOR TO PLAN REVIEW. WPB FBC
 109.1, 109.2, 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2018-12-11 Cont ID  
Sent By RRossano Date 2018-12-11 Time   Rev Time 0.00
Received By rrossano Date 2018-12-11 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-06-27 Cont ID  
Sent By shill Date 2018-06-27 Time 06:53 Rev Time 0.00
Received By shill Date 2018-06-27 Time 06:53 Sent To  
Notes
2018-06-27 06:54:10CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-02-28 Cont ID  
Sent By pleduc Date 2019-02-28 Time   Rev Time 0.00
Received By pleduc Date 2019-02-28 Time 13:17 Sent To  
Notes
2019-02-28 13:29:39THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) FIRE SPRINKLER PROTECTION DOCUMENTS REMAIN WITH THIS
 SUBMITTAL AND CONTRADICT THE RESPONSE COMMENTS
 REAGARDING THE SYSTEM NOT BEING REQUIRED.
  
 IF FIRE PROTECTION IS NOT A PART OF THE SUBMITTAL THOSE
 PALN SHEETS SHALL EITHER BE REMOVED/DELETED OR MARKED
 NOT APPLICABLE IN SOME WAY ON A REVISION SUBMITTAL.
  
 PLEASE MAKE THE NECESSARY REVISONS TO THE FIRE
 PROTECTION SHEETS PRIOR TO FINAL FIRE INSPECTIONS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2018-08-03 Cont ID  
Sent By scaldero Date 2018-08-03 Time 10:25 Rev Time 0.00
Received By scaldero Date 2018-08-03 Time 10:25 Sent To  
Notes
2018-08-03 10:25:52THIS IS A DUPLICATE ENTRY.
 PLAN REVIEWED AND FAILED ON 5/22/18 BY P. LEDUC.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-05-22 Cont ID  
Sent By pleduc Date 2018-05-22 Time   Rev Time 0.00
Received By pleduc Date 2018-05-17 Time 17:05 Sent To  
Notes
2018-05-22 13:23:51THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET A 0.0.02 - THERE IS A NOTE, UNDER BUIOLDING
 CODE DATA, INDICATING "TYPE VB NONSPRINKLERED" YET
 THERE A FIRE PROTECTION DOCUMENTS SHOWING FIRE
 SPRINKLERS.
  
 PLEASE CORRECT OR JUSTIFY.
  
  
  
 2) SHEET A 0.0.02 - UNDER "PROJECTS COMPONENTS,
 BUILDING OCCUPANCY" TABLE THERE ARE NO FIGURES ENTERED
 INTO THE COLUMNS LABLED "FACTOR OR PERSONS".
  
  
 PLEASE CORRECT
  
  
  
 3) SHEET FP 0.0.00 - UNDER THE SECTION "FIRE PROTECTION
 FLOW TEST DATA" THERE ARE NO FIGURES ENTERED INTO AREAS
 INDICATED. THESE FIGURES ARE REQUIRED TO PROVIDE
 ADAQUATE WATER SUPPLY AND SYSTEM DEMANDS.
  
 PLEASE CORRECT.
  
  
  
 4) SHEET FP 0.0.00 - UNDER THE SECTION " DESIGN
 CRITERIA" STORAGE, MECH/ELECT. ROOMS, ORDINARY HAZARD
 GRUOP 1 IS INDICATED. HOWEVER, ON SHEET FP 1.3.01 THERE
 ARE NO HEASD INDICATED IN THE ELECTRICAL ROOM.
  
 PER NFPA 13
  
 8.15.11 ELECTRICAL EQUIPMENT.
 8.15.11.1 UNLESS THE REQUIREMENTS OF 8.15.11.3 ARE MET,
 SPRINKLER
 PROTECTION SHALL BE REQUIRED IN ELECTRICAL EQUIPMENT
 ROOMS.
 8.15.11.2 HOODS OR SHIELDS INSTALLED TO PROTECT
 IMPORTANT
 ELECTRICAL EQUIPMENT FROM SPRINKLER DISCHARGE SHALL BE
 NONCOMBUSTIBLE.
 8.15.11.3 SPRINKLERS SHALL NOT BE REQUIRED IN
 ELECTRICAL EQUIPMENT
 ROOMS WHERE ALL OF THE FOLLOWING CONDITIONS ARE MET:
 (1) THE ROOM IS DEDICATED TO ELECTRICAL EQUIPMENT ONLY.
 (2) ONLY DRY-TYPE ELECTRICAL EQUIPMENT IS USED.
 (3) EQUIPMENT IS INSTALLED IN A 2-HOUR FIRE-RATED
 ENCLOSURE
 INCLUDING PROTECTION FOR PENETRATIONS.
 (4) NO COMBUSTIBLE STORAGE IS PERMITTED TO BE STORED IN
 THE
 ROOM.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY.
  
  
  
 5) SHEET 1.3.01 - THERE APPEARS TO BE NO SPRINKLER HEAD
 COVERAGE IN THE FRONT PORCH BAR AREA.
  
 PER NFPA 13
  
 8.15.1.2.18 SOFFITS, EAVES, OVERHANGS, AND DECORATIVE
 FRAME
 ELEMENTS. SPRINKLERS SHALL BE PERMITTED TO BE OMITTED
 FROM
 WITHIN COMBUSTIBLE SOFFITS, EAVES, OVERHANGS, AND
 DECORATIVE
 FRAME ELEMENTS THAT ARE CONSTRUCTED IN ACCORDANCE WITH
 8.15.1.2.18.1 THROUGH 8.15.1.2.18.4.
 8.15.1.2.18.1 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS,
 AND DECORATIVE
 FRAME ELEMENTS SHALL NOT EXCEED 4 FT 0 IN. (1.2 M) IN
 WIDTH.
 8.15.1.2.18.2 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS,
 AND DECORATIVE
 FRAME ELEMENTS SHALL BE DRAFTSTOPPED, WITH A MATERIAL
 EQUIVALENT TO THAT OF THE SOFFIT, INTO VOLUMES NOT
 EXCEEDING 160 FT3
 (4.5 M3).
 8.15.1.2.18.3 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS,
 AND DECORATIVE
 FRAME ELEMENTS SHALL BE SEPARATED FROM THE INTERIOR OF
 THE BUILDING BY WALLS OR ROOFS OF NONCOMBUSTIBLE OR
 LIMITEDCOMBUSTIBLE
 CONSTRUCTION.
 8.15.1.2.18.4 COMBUSTIBLE SOFFITS, EAVES, OVERHANGS,
 AND DECORATIVE
 FRAME ELEMENTS SHALL HAVE NO OPENINGS OR UNPROTECTED
 PENETRATIONS DIRECTLY INTO THE BUILDING.
  
 PLEASE REVIEW AND PROVIDE HEAD COVERAGE OR JUSTIFY WITH
 SPECIFIC FIRE CODE DETAILS.
  
  
  
 6) THERE ARE NO INDICATIONS OF HOW THIS FIRE SPRINKLER
 SYSTEM WILL BE MONITORED AND WHERE THE FACP WILL BE
 LOCATED.
  
 PLEASE REVIEW AND PROVIDE DETAILS.
  
  
  
 7) THERE ARE NO INDICATIONS OF THE INSTALL OF THE
 KITCHEN HOOD AND/OR FIRE SUPPRESSION SYSTEM.
  
 THE KITCHEN HOOD AND FIRE SUPPRESSION SHALL BE
 SUBMITTED UNDER SEPARATE SHOP DRAWINGS EACH IN
 COMPLIANCE WITH NFPA 96 & 2001.
  
 PLEASE PROVIDE AND APPLICABLE NOTE OF ACKNOWLEDGMENT
 AND COMPLIANCE.
  
  
  
 8) THERE IS A CHLORINE STORAGE ROOM THAT DOES APPEAR TO
 BE PROTECTED PER THE REQUIREMENT.
  
 PER NFPA 101, CHAPTER 12 NEW ASSEMBLY OCCUPANCIES
  
 12.3.2 PROTECTION FROM HAZARDS.
 12.3.2.1 SERVICE EQUIPMENT, HAZARDOUS OPERATIONS OR
 PROCESSES, AND STORAGE FACILITIES.
 12.3.2.1.2 ROOMS OR SPACES FOR THE STORAGE, PROCESSING,
 OR USE OF
 MATERIALS SPECIFIED IN 12.3.2.1.2(1) THROUGH (3) SHALL
 BE PROTECTED
 IN ACCORDANCE WITH ONE OF THE FOLLOWING:
 (1) SEPARATION FROM THE REMAINDER OF THE BUILDING BY
 FIRE BARRIERS
 HAVING A MINIMUM 1-HOUR FIRE RESISTANCE RATING OR
 PROTECTION
 OF SUCH ROOMS BY AUTOMATIC EXTINGUISHING SYSTEMS AS
 SPECIFIED IN SECTION 8.7 IN THE FOLLOWING AREAS:
 (C) ROOMS OR SPACES USED FOR THE STORAGE OF HAZARDOUS
 MATERIALS OR FLAMMABLE OR COMBUSTIBLE LIQUIDS IN
 QUANTITIES DEEMED HAZARDOUS BY RECOGNIZED STANDARDS
  
 PLEASE REVIEW AND CORRECT WITH SPECIFIC DETAILS.
  
  
 9) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 10) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2019-03-21 Cont ID  
Sent By jesmith Date 2019-03-21 Time 13:47 Rev Time 0.00
Received By jesmith Date 2019-03-21 Time 09:50 Sent To  
Notes
2019-03-21 13:47:47GAS APPROVED

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2018-12-27 Cont ID  
Sent By jesmith Date 2018-12-27 Time 16:15 Rev Time 0.00
Received By jesmith Date 2018-12-27 Time 15:03 Sent To  
Notes
2018-12-27 16:14:54CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2012
 5TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2014 5TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2014 5TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2014 5TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2014 5TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 2ND REVIEW
  
 GAS COMMEMTS: DENIED
  
 1.THERE ARE TWO GAS RISERS SHTS P-3.1.01 AND P-3.3.00
 PLEASE CLARIFY PER WPB FBC 107.2.1
 NOTE: P-3.1.01 NATURAL GAS RISER DIAGRAM IS INCOMPLETE
 AND THE CORRECTED DRAWING WITH CALCULATIONS ARE ON
 P-3.3.00
 PLEASE CORRECT AND/ OR DELETE AS REQUIRED PER WPB FBC
 107.2.1
 2. GAS EQUIPMENT ITEMS 2013 AND 2014 SPEC SHEET MBTU
 REQUIREMENTS ARE GREATER THAN THAT CALLED OUT ON
 P-3.3.00. PLEASE CORRECT AS NECESSARY PER WPB FBC
 107.2.1
 PROVIDE GAS EQUIPMENT SCHEDULE LISTING ITEMS 2011
 THROUGH 2014 WITH DESCRIPTION , GWH-1 W/DESCRIPTION AND
 MBTU DEMAND FOR EACH.
 3. SPECIFY 2ND STAGE REGULATORS COMPLYING WITH ANSI
 Z21.80 AND CALL OUT VENT ELIMINATORS OR VENTS AS
 REQUIRED PER WPB FBC 107.2.1. IF VENTS ARE REQUIRED
 SHOW ROUTING, SIZING AND TERMINATION WITH DETAIL ON THE
 PLAN PER WPB FBC 107.2.1
 4. 2ND REQUEST; SUBMIT CALCULATIONS FOR COMBUSTION AIR
 PER THE FBC FG 304.1
 5. SHOW LOCATION OF DIRECT VENT AND EXHAUST VENT
 TERMINALS WHERE THEY PENETRATE THE EXTERIOR WALL ON THE
 PLUMBING FLOOR PLAN P-1.3.03 IN ACCORDANCE WITH FBC FG
 502 THROUGH 505 PER WPB FBC 107.2.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-06-23 Cont ID  
Sent By gjohnson Date 2018-06-23 Time 11:15 Rev Time 0.00
Received By gjohnson Date 2018-06-23 Time 11:15 Sent To  
Notes
2018-06-23 11:40:551ST REVIEW: FBC 2017 6TH EDITION
  
 GAS COMMENTS:
  
 1. THERE ARE TWO GAS RISERS SHTS P.3.1.00 AND P.3.2.00
 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 2. A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE
 THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER
 PRESSURE THAN THE SUPPLY PRESSURE. LINE GAS PRESSURE
 REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSI
 Z21.80. ACCESS SHALL BE PROVIDED TO PRESSURE
 REGULATORS. PRESSURE REGULATORS SHALL BE PROTECTED FROM
 PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR
 OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION. PLEASE SHOW ON RISER ALONG WITH SHUT OFF
 VALVES AND SEDIMENT TRAPS. FBC FG 410.1, 408.4, 409.1
  
 3. GAS NOTE #4 STATES 3" DIRECT VENT THE RISER SHOWS 2"
 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017
 FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR
 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES
 DRYERS).
  
 5. SUBMIT A DETAIL SHOWING THE TYPE OF VENT, LOCATION,
 SIZE, TERMINATION POINT, HEIGHT ABOVE THE ROOF AND
 ANCHORING DETAILS OF THE GAS VENT(S) PER 2017 FBC-FUEL
 GAS SECS. 502 THRU 505 OR 2017 FBC-RES. SEC.G2426
 THROUGH G2439.
  
 6. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT AND
 REGULATORS TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54,
 NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND
 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES
 SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS
 FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT
 THE TIME OF INSPECTION. FGC SEC.305.1, FBC-RES.
 SEC.G2408.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-09-17 Cont ID  
Sent By dbattles Date 2019-09-17 Time 07:42 Rev Time 0.00
Received By dbattles Date 2019-08-22 Time 15:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-04-06 Cont ID  
Sent By shill Date 2019-04-06 Time 07:16 Rev Time 0.00
Received By shill Date 2019-02-19 Time 09:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-02 Cont ID  
Sent By lmarchan Date 2019-01-02 Time 15:51 Rev Time 0.00
Received By lmarchan Date 2018-10-29 Time 13:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-11 Cont ID  
Sent By lmarchan Date 2018-09-11 Time 08:10 Rev Time 0.00
Received By lmarchan Date 2018-05-08 Time 08:17 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2021-01-05 Cont ID  
Sent By shill Date 2021-01-05 Time 10:13 Rev Time 0.00
Received By shill Date 2021-01-05 Time 10:13 Sent To  
Notes
2021-01-05 10:13:30OK PER EMAIL FROM WILLIE SWOOPE
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2020-12-21 Cont ID  
Sent By shill Date 2020-12-21 Time 11:58 Rev Time 0.00
Received By shill Date 2020-12-21 Time 11:58 Sent To  
Notes
2020-12-21 11:58:26PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-04-06 Cont ID  
Sent By shill Date 2019-04-06 Time 07:15 Rev Time 0.00
Received By shill Date 2019-04-06 Time 07:15 Sent To  
Notes
2019-04-06 07:16:13****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
  
 IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-06-19 Cont ID  
Sent By shill Date 2018-06-19 Time 06:44 Rev Time 0.00
Received By shill Date 2018-06-19 Time 06:44 Sent To  
Notes
2018-06-19 06:44:57****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
 THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING
 THAT FEES DUE, IF APPLICABLE, PROVIDED.
  
 AFTER ALL OTHER REVIEWS HAVE PASSED, PRINT OUT ONE SET
 OF PLANS TO TAKE TO THE COUNTY.
  
 561-233-5025 FOR MORE INFORMATION
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-03-26 Cont ID  
Sent By ccole Date 2019-03-26 Time 10:40 Rev Time 0.00
Received By ccole Date 2019-03-26 Time 10:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-11-26 Cont ID  
Sent By ccole Date 2018-11-26 Time 13:56 Rev Time 0.00
Received By ccole Date 2018-11-26 Time 10:29 Sent To  
Notes
2018-11-26 14:42:362ND REVIEW FBC-2017 MECHANICAL
 PERMIT #18050277
 11/26/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A-1.0.05, A-2.0.02, A-5.0.01, A-6.0.00, & M-1.3.01:
 THE EXTERIOR DOORS AND INTERIOR DOORS ENCLOSING THE
 POOL EQUIPMENT STORAGE AND ELECTRICAL ROOMS SHALL BE
 FIRE-RATED PER SECTION 707.6 FBC B. ( CORRECTED
 ARCHITECTURAL PLANS NOW SHOW THE EXTERIOR WALLS TO BE
 3HR FIRE-RATED). FIRE DAMPERS SHALL BE PROVIDED FOR THE
 MAKEUP AIR LOUVERS ON THE EAST WALLS, AND FOR THE AC-1
 OUTDOOR AIR INTAKE LOUVER, THE FOOD PREP EXHAUST
 OUTLET, AND THE EXHAUST HOOD MAKEUP AIR INLET- SECTION
 607.5.2 FBC M.
  
 2) SHEET M-1.3.01: THE STAINLESS STEEL EXHAUST DUCKWORK
 IN THE POOL EQUIPMENT STORAGE ROOM IS NOT IN COMPLIANCE
 WITH SECTION 510.9 FBC M WHICH REQUIRES THE DUCT TO BE
 G90 GALVANIZED OR NON-METALLIC MATERIALS THAT EXHIBIT A
 FLAME SPREAD/SMOKE-DEVELOPED INDEX OF 25/50.
  
 3) M-1.3.01: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR
 EF-1 WITH AN APPROVAL STAMP BY THE ENGINEER OF RECORD.
 THE SPECS SHALL INDICATE THE FAN HAS BEEN TESTED FOR
 USE IN CONVEYING CORROSIVE OR HAZARDOUS EXHAUST FUMES-
 SECTION 304.1 FBC M. A) CLARIFY THE LOCATION OF THE
 FAN- ABOVE OR BELOW THE CEILING. IF LOCATED ABOVE THE
 CEILING PROVIDE AN ACCESS PANEL FOR SERVICE AND
 REPLACEMENT- SECTION 306.1 FBC M.
  
 4) A-2.0.02 & M-1.3.01: AS INDICATED BY NOTE #6 ON
 M-1.3.01 PLEASE SHOW THE EXACT LOCATION OF THE EF-1
 EXHAUST OUTLET TO VERIFY COMPLIANCE WITH SECTION
 501.3.1(2) FBC M. (PLEASE NOTE THIS OUTLET SHALL NOT BE
 PROTECTED WITH A FIRE DAMPER- SECTION 510.6.7 FBC M).
  
 5) M-1.3.01: COMMENT #3(E) FROM THE 1ST TREVIEW STILL
 EXISTS- PLEASE SUBMIT SPECS FOR THE CHEMICAL TANKS IN
 THE POOL EQUIPMENT STORAGE ROOM.
  
 6) COMMENT #2 FROM THE 1ST REVIEW REQUESTING EVIDENCE
 OF ENERGY EFFICIENCY COMPLIANCE WAS NOT ADDRESSED- THE
 PROPOSED BUILDING SHALL BE IN COMPLIANCE WITH THE FBC
 EC. REFER TO SECTIONS C101.2 -SCOPE AND C401.2
 APPLICATION (COMPLIANCE PATHS). PROVIDE A COMPLIANCE
 SUBMITTAL C101.5.1- COMPLIANCE MATERIALS.
  
 7) COMMENT #6 FROM THE 1ST REVIEW STILL EXISTS. IF THE
 REQUESTED WIND LOAD ENGINEERING IS TO BE A DEFERRED
 SUBMITTAL PLEASE INDICATE THAT ON THE CORRECTED PLANS,
 OR IN THE RESPONSE NARRATIVE.
  
 8) COMMENT #8 FROM THE 1ST REVIEW HAS NOT BEEN
 COMPLETELY ADDRESSED. WHEN USING A MECHANICAL
 VENTILATION SYSTEM TO PROVIDE COMBUSTION AIR, THE
 SYSTEM SHALL PROVIDE THE SPECIFIED COMBUSTION RATE IN
 ADDITION TO THE REQUIRED VENTILATION AIR- SECTION
 304.9.3 FBC FG. BASED ON THE AIR BALANCE CALCULATION ON
 M-1.3.01, IT APPEARS THAT ALL VENTILATION AIR FROM AC-1
 WILL BE UTILIZED AS MAKEUP AIR FOR THE EXHAUST SYSTEMS.
  
 9) M-1.3.01: THE LOCATION OF THE MAKEUP AIR OPENING FOR
 THE EXHAUST HOOD SHALL BE A MINIMUM 3' AWAY FROM THE
 FOOD PREP EXHAUST OUTLET- SECTION 501.3.1 (3) FBC M.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-06-11 Cont ID  
Sent By ccole Date 2018-06-11 Time 11:52 Rev Time 0.00
Received By ccole Date 2018-06-11 Time 09:49 Sent To  
Notes
2018-06-11 12:01:181ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18050277
 6/11/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SEPARATE PERMITS ARE REQUIRED FOR THE COMMERCIAL
 KITCHEN HOOD, THE FIRE SUPRESSION SYSTEM, AND THE
 WALKIN FOOD STORAGE AND KEG COOLERS. PLEASE PLACE
 ADVISORY NOTES ON THE PLANS.
  
 2) THE PROPOSED BUILDING SHALL BE IN COMPLIANCE WITH
 THE FBC EC. REFER TO SECTIONS C101.2 -SCOPE AND C401.2
 APPLICATION (COMPLIANCE PATHS). PROVIDE A COMPLIANCE
 SUBMITTAL C101.5.1- COMPLIANCE MATERIALS,
  
 2) SHEET M-1.3.01: PROVIDE EXHAUST VENTILATION
 CALCULATIONS FOR THE TOILET ROOMS, AND THE POOL
 EQUIPMENT AND CHEMICAL STORAGE ROOMS- TABLE 403.3.1 AND
 SECTION 510.2. FBC M
  
 3) M-1.3.01, POOL EQP/STORAGE ROOM: A) INDICATE HOW
 MAKEUP AIR IS BEING PROVIDED TO THE ROOM- SECTION
 510.6.5 FBC M B) CLARIFY HOW THE SYSTEM WILL OPERATE-
 CONTINUOUSLY OR INTERMITTENTLY. C) INDICATE THE TYPE OF
 EXHAUST DUCTWORK TO BE INSTALLED- SECTION 510.9. D) THE
 EXHAUST OUTLET APPEARS TO BE WITHIN 10' OF THE DOORS TO
 THE ROOM AND NOT IN COMPLIANCE WITH SECTION 501.3.1(2)
 FBC M. SHOW ALL REQUIRED CLEARANCE DISTANCE
 MEASUREMENTS ON THE PLAN. E) SUBMIT SPECIFICATIONS FOR
 THE CHEMICAL STORAGE TANKS AND EMBOLDEN THE PRINT ON
 THE TANK SYSMBOLS TO CLEARLY SHOW THE CHEMICAL NAME AND
 GALLON CONTENT- TABLE 414.2.5(1) FBC B.
  
 4) M-0.0.01: PROVIDE AIR BALANCE CALCULATIONS FOR THE
 KITCHEN- SECTION 508.1.2 FBC M
  
 5) M-1.3.01: PROVIDE A DUCT SMOKE DETECTOR ON THE
 SUPPLY TRUNK OF AC-1- SECTION 606.2.1
  
 6) M-1.3.01: PROVIDE WIND LOAD ENGINEERING FOR
 INSTALLATION OF CU-1 & CU-2- SECTION 301.15 FBC M.
  
 7) K-1.4: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL
 GAS-FIRED COOKING EQUIPMENT- SECTION 623.1 FBC FG.
  
 8) M-0.0.01: PROVIDE COMBUSTION AIR CALCULATIONS FOR
 THE GAS-FIRED COOKING APPLIANCES- SECTION 304 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2019-09-16 Cont ID  
Sent By gjohnson Date 2019-09-16 Time 17:05 Rev Time 0.00
Received By gjohnson Date 2019-09-13 Time 10:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2019-03-21 Cont ID  
Sent By jesmith Date 2019-03-21 Time 13:59 Rev Time 0.00
Received By jesmith Date 2019-03-21 Time 09:49 Sent To  
Notes
2019-03-21 13:59:37CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 3RD REVIEW
 PLUMBING COMMEMTS: DENIED
 1. RE: A-0.0.02; REVISE FIXTURE BREAKDOWN TO REFLECT
 2017 FBC PL 403 AS REQUIRED BY WPB FBC 107.2.1. ARCH
 A-0.0.02 STILL NOT CORRECTED.
 2. RE: A-2.0.03; ALL REFERENCE TO 2014 CODES SHALL BE
 REVISED TO READ 2017 PER WPB FBC 107.2.1. PLUMBING
 P0.0.00 OK; ARCH A2.0.03 STILL NOT CORRECTED. ADDED
 8/22//2019, PER CONVERSATION WITH STACEY, REFERENCE ON
 A-2.0.03 WAS NOT FOUND. CORRECTION WAS MADE ON A-.0.01.
 IF UPON REVIEW OF RESUBMITTED PLANS, THE REFERENCE IS
 STILL FOUND WE WILL REDLINE IT ON THE PLANS TO CONFORM.
 3. RE: P-3.0.00; SANITARY PIPING FROM TOILET ROOM
 TOILET BATTERY SHALL NOT DISCHARGE INTO THE COMBINATION
 WASTE AND VENT BRANCH PER FBC PL 915.1. CONNECT AT A
 POINT DOWNSTREAM OF THE COMBINATION WASTE AND VENT
 BRANCH. P-1.3.1.01 FLOOR PLAN HAS BEEN CORRECTED BUT
 P-3.0.00 RISER DIAGRAM HAS NOT. PLEASE CORRECT PER WPB
 FBC 107.2.1.
 4. RE: P-3.1.00; PER WPB FBC 107.2.1 PLEASE PROVIDE
 CALULATIONS FOR SIZING OF GREASY WASTE SYSTEM.
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN
 ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-12-27 Cont ID  
Sent By jesmith Date 2018-12-27 Time 14:20 Rev Time 0.00
Received By jesmith Date 2018-12-20 Time 15:02 Sent To  
Notes
2018-12-27 14:20:02CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2012
 5TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2014 5TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2014 5TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2014 5TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2014 5TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 2ND REVIEW
  
 PLUMBING COMMEMTS: DENIED
  
  
 1. RE: A-0.0.02; REVISE FIXTURE BREAKDOWN TO REFLECT
 2017 FBC PL 403 AS REQUIRED BY WPB FBC 107.2.1
 2. 2ND REQUEST; A-0.0.02 THE PLUMBING FIXTURE BREAKDOWN
 IS LISTED FOR THE TENNIS CLUB HOUSE PLEASE PROVIDE A
 BREAKDOWN FOR THE WATERSIDE BAR, THE POOL AND
 SURROUNDING AREA ALONG WITH A SITE PLAN THAT SHOWS THE
 OCCUPANT LOAD FOR EACH AREA. THE FIXTURE COUNT SHALL
 COMPLY WITH FBC PL TABLE 403.1 ADDITION INFORMATION
 REQUIRED PER WPB FBC 107.2.1 NOTE; ARCHITECT DID NOT
 ADDRESS CONCERNS FOR THE POOL AND SURROUNDING AREAS AS
 REQUESTED.
 3. RE: A-2.0.03; ALL REFERENCE TO 2014 CODES SHALL BE
 REVISED TO READ 2017 PER WPB FBC 107.2.1
 4. 2ND REQUEST:
 RE: P-0.0.00; THE PLUMBING SPEC UNDER THE PIPE HANGER
 SPACING SCHEDULE SHALL COMPLY WITH FBC PL TABLE 308.5.
  GIVE EXTRA CONSIDERATION TO COPPER TUBING.
 5. 2ND REQUEST: RE; P-0.0.01 + P-3.3.00 THE SCHEDULE
 FOR THE WATER HEATER, EXPANSION TANK AND RECIRCULATION
 PUMP DO NOT MATCH PLEASE CLARIFY AND PROVIDE
 MANUFACTURE SPECIFICATION. PER WPB AMEND TO FBC 107.2.1
 SEE FOLLOWING AND CLARIFY PER WPB FBC 107.2.1
 A. EXPANSION TANK P-0.0.00=ET-1, P-3.3.00 &
 P-3.4.00=EX-1.
 B. SCHEDULES FOR HOT WATER RECIRCULATING PUMP(S) ON
 P-3.4.00 AND P-0.0.00 DO NOT MATCH.
 C. SCHEDULES FOR GAS WATER HEATER ON P-3.4.00 AND
 P-0.0.00 DO NOT MATCH.
 D. SCHEDULES FOR MIXING VALVE ON P-3.4.00 AND P-0.0.00
 DO NOT MATCH.
 6. 2ND REQUEST: PLEASE SHOW TRAP PRIMERS ON THE FLOOR
 DRAIN ON THE ISOMETRIC DRAWING. PER FBC PL 1002.4.1
 IN LIEU OF SHOWING THE TRAP PRIMERS PROVIDE A NOTE ON
 P-3.0.00 RISER DIAGRAM STATING ?PROVIDE TRAP PRIMERS
 FOR ALL FLOOR DRAINS; SEE P-4.1.00, DETAILS 5 & 6?
 7. IT APPEARS THAT THE ORIGINAL DOMESTIC WATER RISER
 DIAGRAM P-3.1.00 NOW CONTAINS THE GREASY WASTE
 ISOMETRIC AND GREASE INTERCEPTOR CALCULATIONS.
 A. 2ND REQUEST: ON THE WATER ISOMETRIC PLEASE SIZE THE
 BRANCH PIPING FOR THE GANG BATHROOMS. 107.3.5.1.3(13)
 OK. SHOWN ON P-3.2.00 (SEE NOTES BELOW CONCERNING
 CONFUSION OF PDF TITLES)
 B. 2ND REQUEST; PLEASE PROVIDE PIPING DETAILS FOR THE
 WATER FILTERS BNB-2, BNB-2.1 AND 2015.1.
 107.3.5.1.3(13)
 C. 2ND REQUEST; PLEASE PROVIDE BACKFLOW DEVICES FOR THE
 WATER FILTER, ICE MACHINE, BEVERAGE DISPENSERS AND
 COFFEE MAKERS. PER FBC PL 608.3 , 608.16.1, 608.16.10
 NOTE 3 ON P-1.3.03 DOES NOT SEEM TO ADDRESS THIS ISSUE.
 D. TO SUMMARIZE, WATER RISER ISOMETRIC FOR THE PROJECT
 SHALL SHOW ALL REQUIRED VALVES, BACKFLOW PREVENTERS,
 WATER HAMMER ARRESTORS AND OTHER PERTINENT DEVICES PER
 WPB FBC 107.2.1
 ADDITIONAL COMMENTS
 1 .RE: P-3.0.00; SANITARY PIPING FROM TOILET ROOM
 TOILET BATTERY SHALL NOT DISCHARGE INTO THE COMBINATION
 WASTE AND VENT BRANCH PER FBC PL 915.1. CONNECT AT A
 POINT DOWNSTREAM OF THE COMBINATION WASTE AND VENT
 BRANCH. CORRECT ON P-1.3.01 TO REFLECT THE SAME.
 2. RE: P-0.0.01; FIXTURE SCHEDULE L-1 AND L-2, CALL FOR
 TMV PER FBC 416.5 AND SPECIFY PER WPB WPC 107.2.1
 3. RE: P-4.1.00; DETAIL FOR SENSOR FAUCET CONNECTION,
 SPECIFY TMV PER WPB WPC 107.2.1
 4. RE: P-4.0.00; DETAILS 5 & 6 FLUSHING FLOOR DRAINS.
 WHERE ARE THESE BEING USED? SHOW ON FLOOR PLAN AND
 SCHEDULE, SPECIFY CODE COMPLIANT FLUSH VALVE. IF NOT
 PART OF PROJECT THEN DELETE THE DETAILS. WPB FBC
 107.2.1
 5. RE: P-3.3.00, P-3.4.00; WATER HEATER DETAILS ARE
 CONFLICTING. RECONCILE THE DETAILS TO MATCH EACH OTHER
 PER WPB FBC 107.2.1. PLEASE NOTE THE SCHEMATIC DETAIL
 #1 ON P-3.4.00 IS CONFUSING. THE ISOMETRIC DETAIL #2 ON
 P-3.4.00 IS VERY BUSY AND THERE ARE A NUMBER OF ENDS
 THAT ARE NOT IDENTIFIED. DIFFERENT DETAILS HAVE
 DIFFERENT QUANTITIY OF HOT WATER RECIRCULATION PUMPS.
 THERE IS DIFFERENT INFO FOR EXPANSION TANK.
 THE VENTING AND COMBUSTION AIR FOR THE WATER HEATER IS
 DIFFERENT IN DIFFERENT DETAILS.
 SPECIAL NOTES:
 P-3.3.00 ENLARGED WATER HEATING SYSTEM IS ACTUALLY THE
 PLUMBING NATURAL GAS RISER DIAGRAM
 P-3.2.00 NATURAL GAS RISER DIAGRAM IS ACTUALLY THE
 PLUMBING DOMESTIC WATER RISER DIAGRAM
 P-3.1.00 PLUMBING DOMESTIC WATER RISER DIAGRAM IS
 ACTUALLY THE PLUMBING GREASE WASTE DRAINAGE RISER
 DIAGRAM
 P-3.1.01 NATURAL GAS RISER DIAGRAM IS INCOMPLETE AND
 THE CORRECTED DRAWING AND CALCULATIONS ARE ON P-3.3.00
 PLEASE CORRECT AND OR DELETE AS REQUIRED PER WPB FBC
 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-23 Cont ID  
Sent By gjohnson Date 2018-06-23 Time 08:00 Rev Time 0.00
Received By gjohnson Date 2018-06-22 Time 11:00 Sent To  
Notes
2018-06-23 11:14:331ST REVIEW: FBC 2017 6TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. A.0.0.02 THE PLUMBING FIXTURE BREAKDOWN IS
 LISTED FOR THE TENNIS CLUB HOUSE PLEASE PROVIDE A
 BREAKDOWN FOR THE WATERSIDE BAR, THE POOL AND
 SURROUNDING AREA ALONG WITH A SITE PLAN THAT SHOWS THE
 OCCUPANT LOAD FOR EACH AREA. THE FIXTURE COUNT SHALL
 COMPLY WITH FBC PL TABLE 403.1 ADDITION INFORMATION
 REQUIRED PER WPB AMEND TO FBC 107.2.1
  
 2. SHT. A.2.0.03 SHOW CLEAR FLOOR SPACE FOR ACCESSIBLE
 TOILETS AND SHOW DIMENSIONS ON ALL ACCESSIBLE CLEAR
 FLOOR FOR ALL FIXTURES. PER WPB AMEND TO FBC 107.2.1
 FBC ACC 604.3.1, 602.2, 605.3, 606.2
  
 3. SHT. A.7.0.01 THE DIMENSIONS ON THE DETAILS ARE
 EXTREMELY LIGHT AND HARD TO READ PLEASE DARKEN ALL
 DIMENSIONS. PER WPB AMEND TO FBC 107.2.1
  
 4. SHT. P.0.0.00 THE PLUMBING SPEC 1.2, 1.6, 4.1 SHALL
 REFLECT THE CURRENT CODE FBC PL 2017 6TH EDITION
  
 5. SHT. P.0.0.00 THE PLUMBING SPEC UNDER THE PIPE
 HANGER SPACING SCHEDULE SHALL COMPLY WITH FBC PL TABLE
 308.5
  
 6. PROVIDE A SITE PLAN SHOWING THE GREASE INTERCEPTOR
 AND PIPING DETAIL. PER WPB AMEND TO FBC 107.2.1,
 107.3.5.1.3(11)
  
 7. PROVIDE SIZING CALCULATION FOR THE GREASE
 INTERCEPTOR. PER WPB AMEND TO FBC 107.2.1,
 107.3.5.1.3(11)
  
 8. SHT. P.0.0.01 + P.3.3.00 THE SCHEDULE FOR THE WATER
 HEATER, EXPANSION TANK AND RECIRCULATION PUMP DO NOT
 MATCH PLEASE CLARIFY AND PROVIDE MANUFACTURE
 SPECIFICATION. PER WPB AMEND TO FBC 107.2.1
  
 9. SHT. P.3.3.00 DETAILS #3 + 35 APPEAR TO BE DIFFERENT
 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 10. PLEASE EXPAND THE SANITARY ISOMETRIC AND SEPARATE
 THE SANITARY FROM THE GREASE. 107.3.5.1.3(13)
  
 11. PLEASE SHOW TRAP PRIMERS ON THE FLOOR DRAIN ON THE
 ISOMETRIC DRAWING. PER FBC PL 1002.4.1
  
 12. THE PLUMBING FIXTURES IN THE BAR AREA SHALL ALSO
 DISCHARGE TO THE GREASE SYSTEM. PER FBC 1003.3.1 AND
 WEST PALM BEACH, FLORIDA - CODE OF ORDINANCES SEC.
 90-125.(7) SEC. 90-126.(7)
  
 13. THE HAND SINK IN THE KITCHEN DOES NOT APPEAR TO BE
 ON THE ISOMETRIC PLEASE CLARIFY. 107.3.5.1.3(13)
  
 14. ON THE WATER ISOMETRIC PLEASE SIZE THE BRANCH
 PIPING FOR THE GANG BATHROOMS. 107.3.5.1.3(13)
  
 15. PLEASE PROVIDE PIPING DETAILS FOR THE WATER FILTERS
 BNB-2, BNB-2.1 AND 2015.1. 107.3.5.1.3(13)
  
 16. PLEASE PROVIDE BACKFLOW DEVISES FOR THE WATER
 FILTER, ICE MACHINE, BEVERAGE DISPENSERS AND COFFEE
 MAKERS. PER FBC PL 608.3 , 608.16.1, 608.16.10
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2019-03-22 Cont ID  
Sent By dbattles Date 2019-03-22 Time 08:52 Rev Time 0.00
Received By dbattles Date 2019-03-22 Time 08:52 Sent To  
Notes
2019-03-22 08:52:47PROVIDE ROOFING PRODUCT APPROVALS WITH SUB PERMIT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2019-09-17 Cont ID  
Sent By dbattles Date 2019-09-17 Time 07:42 Rev Time 0.00
Received By dbattles Date 2019-09-17 Time 07:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-03-22 Cont ID  
Sent By dbattles Date 2019-03-22 Time 08:41 Rev Time 0.00
Received By dbattles Date 2019-03-22 Time 08:41 Sent To  
Notes
2019-03-26 10:56:05MECH SHEETS GOOD.
2019-03-18 13:37:11ELECTRICAL SHEETS OK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2018-12-13 Cont ID  
Sent By dbattles Date 2018-12-13 Time 13:25 Rev Time 0.00
Received By dbattles Date 2018-12-12 Time 13:21 Sent To  
Notes
2018-12-13 13:25:31NEW SHEETS WILL NEED TO BE REVIEWED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-06-19 Cont ID  
Sent By shill Date 2018-06-19 Time 06:51 Rev Time 0.00
Received By shill Date 2018-06-19 Time 06:44 Sent To  
Notes
2018-06-19 06:51:48SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. DIGITAL SIGNATURES/SEALS (PLAN PAGES) ARE IN
 ACCORDANCE WITH FS 471, FS 481 AS NOTED. NEW SHEETS
 SUBMITTED IN THE NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. LOAD CALCS S&S (IN SUPPORTING DOCUMENTS FOLDER) IS
 NOT DIGITALLY SIGNED AND SEALED.
  
 3. STRUCTURAL CALCS (IN SUPPORTING DOCUMENTS FOLDER) OK
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2019-04-03 Cont ID  
Sent By jroach Date 2019-04-03 Time 16:05 Rev Time 0.00
Received By jroach Date 2019-04-03 Time 16:05 Sent To  
Notes
2019-04-03 16:06:37PROVISOS:
  
 1. THE SCOPE OF THIS PERMIT REVIEW IS LIMITED TO THE
 ?WATER SIDE BAR.? SEPARATE PERMITS REQUIRED FOR
 FENCING, LANDSCAPING, IRRIGATION, ETC.
  
 2. THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED
 DEVELOPMENT SHALL BE SUBJECT TO ALL DEVELOPMENT ORDER
 CONDITIONS AND DESIGN GUIDELINES, AS OUTLINED IN
 RESOLUTION NO. 307-17, APPROVED ON NOVEMBER 20, 2017,
 AND AS MAY BE AMENDED.
 _______________________________________________________
 _____________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 P: 561.822.1448 | E: [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2018-11-29 Cont ID  
Sent By jroach Date 2018-11-29 Time 15:53 Rev Time 0.00
Received By jroach Date 2018-11-29 Time 15:53 Sent To  
Notes
2018-11-29 15:53:35ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 09.10.2018
 PERMIT NO.: 18050277
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THESE MODIFICATIONS WILL REQUIRE A MINOR AMENDMENT
 TO THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED
 DEVELOPMENT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-09-10 Cont ID  
Sent By JR Date 2018-09-10 Time 11:07 Rev Time 0.00
Received By jroach Date 2018-09-10 Time 11:07 Sent To  
Notes
2018-09-10 11:09:25ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 09.10.2018
 PERMIT NO.: 18050277
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PURSUANT TO MEETINGS WITH THE DEVELOPER, ARCHITECT,
 ETC. ON 9/4 /AND 9/7, DETAILS ARE TO BE PROVIDED
 REGARDING THE REAR OF THE PROPOSED STRUCTURE, THE
 SCREENING OF EQUIPMENT, ENHANCEMENT OF ARCHITECTURE,
 ETC. THESE MODIFICATIONS WILL REQUIRE A MINOR AMENDMENT
 TO THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED
 DEVELOPMENT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH