Plan Review Details - Permit 18050273
| Plan Review Stops For Permit 18050273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-23 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-23 |
Time |
07:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-07 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-07 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2018-06-07 17:58:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FROM PREVIOUS LIST: | | | | | | ON THE ROOF PRODUCT APPROVAL, INDICATE WHICH ASSEMBLY | | | IS PROPOSED. IF THE ASSEMBLY DESIGN PRESSURE DOES NOT | | | MEET THE DESIGN PRESSURES FOR ZONES 2 AND 3, | | | ENGINEERING FOR ENHANCED FASTENING IS REQUIRED. | | | | | | 2ND REVIEW, THE ASSEMBLY SELECTED DOES NOT MEET THE | | | DESIGN PRESSURE REQUIREMENT FOR ZONES 2 AND 3. PROVIDE | | | RAS117 CALCULATIONS (SEE GENERAL LIMITATION #7 ON THE | | | PRODUCT APPROVAL). | | | | | | OTHER PRODUCTS OK. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-09 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-09 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2018-05-09 12:51:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. ON THE ROOF PRODUCT APPROVAL, INDICATE WHICH | | | ASSEMBLY IS PROPOSED. IF THE ASSEMBLY DESIGN PRESSURE | | | DOES NOT MEET THE DESIGN PRESSURES FOR ZONES 2 AND 3, | | | ENGINEERING FOR ENHANCED FASTENING IS REQUIRED. | | | | | | OTHER PRODUCTS OK. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-06-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-23 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-18 |
Time |
14:09 |
Sent To |
I |
|
| Notes |
| 2018-06-19 14:10:14 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-07 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-04 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2018-06-05 11:11:15 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-09 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-07 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2018-05-08 10:47:09 | SUBMITTAL ROUTED TO SHILL |
|
|
|