| Plan Review Stops For Permit 18050255 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-13 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-13 |
Time |
14:53 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-14 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-14 |
Time |
11:18 |
Sent To |
I |
|
| Notes |
| 2018-08-14 12:21:12 | INCREASED VALUE TO $75,000.00 CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-12 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-12 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2018-05-12 10:37:44 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE APPEARS LOW FOR PROPOSED SCOPE OF WORK. | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-13 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-13 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-28 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-28 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2018-08-28 10:24:31 | ONLY ONE COMPLETE SET OF PLANS DATED 8/23/18 NEED TYWO | | | SETS AS A MINIMUM. | | | | | | VALUE OF WORK IS TO INCLUDE THE COST OF THE MATERIAL, | | | GENERATOR AND TRANSFER SWITCH. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-14 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-14 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2018-08-14 10:25:37 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | COMMENT #1 PANEL "G" NOT DONE NO AIC RATING SHOWN | | | | | | COMMENT #2 NO CALCLUATION SHOWN ON DRAWINGS FAULT | | | CURRENT CALC NO SHOWN | | | | | | COMMENT #9 NO SIZE ON PULL BOX | | | | | | COMMENT #10 NO GROUNDING DETAIL SHOWN | | | | | | COMMENT #11 NO CONTRACT SUBMITTED, PERMIT VALUE WILL BE | | | BASED ON $75,000. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-10 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-10 |
Time |
11:27 |
Sent To |
FIRE |
|
| Notes |
| 2018-05-10 11:26:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9 | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 3. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 4. PROVIDE RATED VOLTAGE OF SYSTEM ON PLAN. WPB FBC | | | 107.2.1; NEC 110.4 | | | 5. PROVIDE LOAD CALCULATION FOR SERVICE TO CONFIRM | | | CAPACITY OF GENERATOR IS ADEQUATE. NEC 215.2, 220, | | | 408.30, 702.4 | | | 6. PROVIDE SIGNS FOR GENERATOR IN COMPLIANCE WITH NEC | | | 702.6. | | | 7. PROVIDE EQUIPMENT GROUNDING CONDUCTOR IN CONDUITS | | | FROM TRANSFER SWITCH TO INTERIOR PANEL. INCLUDE | | | DIRECTION TO SEPARATE GROUNDS AND NEUTRALS AT THE | | | ORIGINAL MAIN, WHICH WILL NOW BE A SUB-PANEL. NEC | | | 250.122 | | | 8. PROVIDE PANEL SCHEDULE FOR ANY NEW CIRCUITS THAT | | | WILL BE ADDED FOR GENERATOR LIGHTING, BLOCK HEATER, | | | ETC. WPB FBC 107.2.1; NEC 215.2, 408.4 | | | 9. PULL BOX MUST BE SIZED PER NEC 314.28(A)(2). PROVIDE | | | CORRECTION. | | | 10. PROVIDE DETAIL OF GROUNDING ELECTRODE SYSTEM AND | | | ATTACHMENT TO MAIN SERVICE, WHICH WILL NOW BE THE | | | TRANSFER SWITCH. NEC 250.50, 250.53, 250.64 | | | 11. VALUE SPECIFIED ON PERMIT APPLICATION APPEARS LOW. | | | PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE OF | | | WORK, TO INCLUDE ALL MATERIALS AND LABOR. FBC 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-09-13 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-09-13 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2018-09-13 15:05:04 | PER SCALDERON |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-31 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-31 |
Time |
13:56 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-05-11 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-05-11 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-09-13 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-08-29 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2018-08-30 15:06:32 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-28 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-23 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2018-08-27 11:51:28 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-14 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-07-20 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2018-07-24 09:39:11 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-12 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-04 |
Time |
13:09 |
Sent To |
I |
|
| Notes |
| 2018-05-07 13:09:27 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-09-06 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-09-06 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-09-06 |
Time |
10:26 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-27 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-27 |
Time |
09:03 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
M. Cruz |
Date |
2018-05-09 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2018-05-09 |
Time |
|
Sent To |
B |
|
| Notes |
|
|