| Plan Review Stops For Permit 18050248 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-30 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-30 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-30 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-30 |
Time |
17:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-27 |
Time |
19:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-27 |
Time |
19:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-21 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-21 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-25 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-25 |
Time |
10:46 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-06-27 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-06-27 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-05-11 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-05-11 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2018-05-11 11:34:25 | PERMIT # 18050248 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | APPROVED WITH COMMENTS: | | | | | | 1) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | 2) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN BACK | | | OF HOUSE TO ENSURE EGRESS PATH REQUIREMENTS ARE | | | MAINTAINED AT ALL TIMES. | | | | | | 3) PROVIDE A K-TYPE PORTABLE FIRE EXTINGUISHER AND | | | ASSOCIATED SIGNAGE IN KITCHEN AREA. | | | | | | 4) KITCHEN HOOD SUPPRESSION SYSTEM SHALL BE TIED INTO | | | THE BUILDING FIRE ALARM SYSTEM TO INITIATE A GENERAL | | | FIRE ALARM CONDITION. | | | | | | 5) DEEP FAT FRYERS SHALL BE EQUIPPED WITH A SEPARATE | | | HIGH-LIMIT CONTROL IN ADDITION TO THE ADJUSTABLE | | | THERMOSTAT TO SHUT OFF FUEL OR ENERGY WHEN THE FAT | | | TEMPERATURE REACHES 475F DEGREES AT 1-INCH BELOW THE | | | SURFACE. | | | | | | 6) COOKING OPERATIONS PRODUCING SMOKE OR GREASE-LADEN | | | VAPORS SHALL BE PROTECTED WITH A CLASS I MECHANICAL | | | EXHAUST HOOD EQUIPPED WITH AN AUTOMATIC WET-CHEMICAL | | | FIRE SUPPRESSION SYSTEM. | | | | | | 7) SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO | | | THE FIRE ALARM AND SPRINKLER SYSTEM. | | | | | | | | | SUE ELLEN CALDERON | | | ASST. FIRE MARSHAL | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-02 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-02 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-07-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-06 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-06 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2018-07-06 07:24:37 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | GAS COMMENTS: IT APPEARS THAT NONE OF THE GAS COMMENTS | | | WERE ADDRESSED AND NO RESPONSE LETTER A RESPONSE LETTER | | | WILL HELP EXPEDITE THE REVIEW PROCESS. | | | | | | 1. PLEASE SHOW THE 1" BRANCH FOR NEW TANKLESS WATER | | | HEATER ON THE RISER DIAGRAM WITH THE BTU LOAD. PER WPB | | | AMEND TO FBC (9) | | | | | | 2. DRIP LEGS REQUIRED PLEASE SHOW THEM ON THE RISER . | | | PER FBC FG 408.4 | | | | | | 3. PLEASE SHOW THE LENGTH OF EACH CUT SECTION OF PIPE. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PROVIDE THE TOTAL LENGTH FROM THE METER TO THE STEP | | | DOWN REGULATOR 2PSI TO .5PSI SHOW ON THE RISER ALSO. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. SHT. P2.1 THE NOTE FOR THE GAS IS STATING A SYSTEM | | | OF LESS THAN 2PSI .5 PRESSURE DROP BUT IT LIST TABLE | | | 402.4(5) WHICH IS 2PSI PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 6. SHOW SIZE ON PIPING FROM METER TO FIRST REGULATOR. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 8. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | NEW COMMENT | | | | | | 1. SHT. P2.1 UNDER WATER PLAN KEYED NOTES #4 THE | | | CONTRACTOR SHALL RUN A NEW GAS LINE TO A HVAC EQUIPMENT | | | ON THE ROOF PLEASE SHOW ON THE GAS ISOMETRIC DRAWING | | | AND INCLUDE IN TOTAL BTU LOAD. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. PROVIDE ANY EXISTING BTU LOAD ON EXISTING GAS SYSTEM | | | SHOW ON GAS ISO. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-05 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-05 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2018-06-05 16:20:45 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | GAS COMMENTS: | | | | | | 1. PLEASE SHOW THE 1" BRANCH FOR NEW TANKLESS WATER | | | HEATER ON THE RISER DIAGRAM WITH THE BTU LOAD. PER WPB | | | AMEND TO FBC (9) | | | | | | 2. DRIP LEGS REQUIRED PLEASE SHOW THEM ON THE RISER . | | | PER FBC FG 408.4 | | | | | | 3. PLEASE SHOW THE LENGTH OF EACH CUT SECTION OF PIPE. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PROVIDE THE TOTAL LENGTH FROM THE METER TO THE STEP | | | DOWN REGULATOR 2PSI TO .5PSI SHOW ON THE RISER ALSO. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. SHT. P2.1 THE NOTE FOR THE GAS IS STATING A SYSTEM | | | OF LESS THAN 2PSI .5 PRESSURE DROPBUT IT LIST TABLE | | | 402.4(5) WHICH IS 2PSI PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 6. SHOW SIZE ON PIPING FROM METER TO FIRST REGULATOR. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 8. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-02 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-18 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2018-07-30 09:11:59 | 7/30 TO GJ DESK | | | | | 2018-07-26 18:37:10 | 7/26 ON SH DESK | | | | | 2018-07-19 15:10:52 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-07-16 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-06-14 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-05 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-04 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-07-12 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-07-12 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2018-07-12 12:49:17 | HOOD PERMIT NEEDED | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-17 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-05-17 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-05-17 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2018-05-17 13:29:37 | NEED SEPRATE PERMIT, SEALED DRAWING AND PERMIT FOR HOOD | | | PLAN NOT REVIEWED | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-02 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-02 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-07-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-06 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-05 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2018-07-06 07:13:25 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: DOES NOT APPEAR THAT ANY OF THE | | | PLUMBING COMMENTS WERE ADDRESSED AND THERE WAS NO | | | RESPONSE LETTER, A RESPONSE LETTER WILL HELP EXPEDITE | | | REVIEW PROCESS. | | | | | | 1. PLEASE PROVIDE WATER ISOMETRIC FOR ALL NEW WATER | | | PIPING. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. PROVIDE MANUFACTURE SPECIFICATIONS FOR THE WATER | | | FILTER AND CARBONATOR. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. A BACK FLOW IS REQUIRED FOR ICE MACHINE, WATER | | | FILTER AND CARBINATOR, DRINK MACHINES AND COFFEE | | | MAKERS. PER FBC PL 608.3 , 608.16.1 , 608.16.10 | | | | | | 4. TRAP PRIMERS ARE REQUIRED AT ALL NEW FLOOR DRAINS. | | | PER FBC PL 1002.4.1 | | | | | | NEW COMMENT: | | | | | | 1. PROVIDE SANITARY ISOMETRIC FOR THE DROP IN HAND SINK | | | 4.55. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-05 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-04 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2018-06-05 14:52:47 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE WATER ISOMETRIC FOR ALL NEW WATER | | | PIPING. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. PROVIDE MANUFACTURE SPECIFICATIONS FOR THE WATER | | | FILTER AND CARBONATOR. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. A BACK FLOW IS REQUIRED FOR ICE MACHINE, WATER | | | FILTER AND CARBINATOR, DRINK MACHINES AND COFFEE | | | MAKERS. PER FBC PL 608.3 , 608.16.1 , 608.16.10 | | | | | | 4. TRAP PRIMERS ARE REQUIRED AT ALL NEW FLOOR DRAINS. | | | PER FBC PL 1002.4.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-05-15 |
Time |
12:09 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-05-15 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|