Plan Review Details - Permit 18050129
| Plan Review Stops For Permit 18050129 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-23 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-23 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2018-06-23 08:38:03 | VERIFIED SIGNATURES ON PAPER PLANS FOR DIGITAL | | | SUBMITTAL. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-05-22 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-22 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2018-05-22 10:15:57 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. PAGE S0.2 WIND DIAGRAM DOES NOT INCLUDE A FLAT ROOF, | | | AND PRESSURES ON THAT PAGE ARE TOO LOW FOR A FLAT ROOF. | | | CLARIFY LOCATION WHERE THE CERTAINTEED MODIFIED IS | | | PROPOSED, FBC 107, FBC B 1609. | | | | | | 2. THE ASSEMBLY PROPOSED (#11, PAGE 7 OF 10) FOR THE | | | SLOPE ROOF UNDERLAYMENT HAS A LIMITATION OF -75PSF; | | | SHEETS S0.2 REQUIRES -97.56 FOR THE OVERHANG ZONE. | | | | | | 3. THE ENGINEER'S REVIEW STAMP COVERS SOME OF THE | | | INFORMATION ON THE AC STAND ENGINEERING; PROVIDE A | | | CLEAN COPY. | | | | | | 4. AC STAND, INDICATE WHICH OPTION IS PROPOSED. ALSO | | | PROVIDE INFORMATION REGARDING THE UNIT TO SHOW | | | COMPLIANCE WITH FBC B 1510.10 (CLEARANCE). | | | | | | 5. EUROWALL, INDICATE WHICH PANEL WIDTH IS PROPOSED, | | | FBC B 1609. DP IS TO COMPLY WITH DESIGN PRESSURES | | | SPECIFIED ON SHEET S0.2. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-23 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-18 |
Time |
09:19 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-22 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-03 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2018-06-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-23 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-23 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2018-06-20 09:19:51 | HARD COPIES ROUTED TO SHILL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-22 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-22 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2018-05-22 10:22:39 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. CURB DETAIL AND CALCULATIONS PREPARED BY BOWDOIN G | | | HUTCHINSON, PE IS NOT DIGITALLY SIGNED AND SEALED. | | | PROVIDE A PAPER ORIGINAL, FS471 OR A DIGITALLY SIGNED | | | AND SEALED DOCUMENT. | | | | | | 2. ROOF CALCS PREPARED BY ALBERTO CARDONA, PE IS NOT | | | DIGITALLY SIGNED AND SEALED. PROVIDE A PAPER ORIGINAL, | | | FS471 OR A DIGITALLY SIGNED AND SEALED DOCUMENT. | | | | | | 3. AC STAND ENGINEERING PREPARED BY DENIS K. SOLANO, PE | | | ARE NOT DIGITALLY SIGNED AND SEALED. PROVIDE A PAPER | | | ORIGINAL, FS471 OR A DIGITALLY SIGNED AND SEALED | | | DOCUMENT. | | | | | | |
|
|
|