Plan Review Details - Permit 18050079
Plan Review Stops For Permit 18050079
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-06-07 Cont ID  
Sent By cthroop Date 2018-06-07 Time 11:07 Rev Time 0.00
Received By cthroop Date 2018-06-04 Time 16:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-06-14 Cont ID  
Sent By jpearson Date 2018-06-14 Time 14:35 Rev Time 0.00
Received By jpearson Date 2018-06-14 Time 14:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-05-22 Cont ID  
Sent By jpearson Date 2018-05-22 Time 15:30 Rev Time 0.00
Received By jpearson Date 2018-05-22 Time 12:15 Sent To  
Notes
2018-05-22 15:30:55CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE PANEL FOR PANEL LA. NEC 225.31,
 225.32
 2. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A
 BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH
 CIRCUIT. NEC 250.32; FBC RE3607.3
 3. NOTE 1 ON SHEETS E-2 AND E-3 DOES NOT ADDRESS THE
 AFCI REQUIREMENTS PER THE 2014 NEC. ALL BRANCH CIRCUITS
 THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE
 OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING
 ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. PROVIDE CORRECTION. NEC
 210.12; FBC RE E3902.16
 4. NOTE 2 ON SHEETS E-2 AND E-3 STATES THAT RECEPTACLES
 SHALL BE TR PER THE 2011 NEC, WHICH IS NOT THE CURRENT
 CODE. PROVIDE CORRECTION. FBC PREFACE.
 5. RISER DIAGRAM SHOWS THE PANELS AS 10K AIC RATED,
 WHILE THE PANEL SCHEDULES SHOWS THEM AS 22K AIC RATED.
 CORRECT DISCREPANCY. WPB FBC 107.2.1
 6. GFCI PROTECTION IS REQUIRED FOR ALL OUTLETS IN
 GARAGE INCLUDING THE GARAGE DOOR OPENER. PROVIDE
 CORRECTION. NEC 210.8; FBC RE E3902.2
 7. GFCI RECEPTACLES IN GARAGE ARE SHOWN ON THE SAME
 CIRCUIT AS ITEMS LOCATED OUTSIDE OF GARAGE. PROVIDE
 CORRECTION. NEC 210.52(G)(1); FBC RE E3901.9
 8. PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC
 210.8(D); FBC RE E3902.10
 9. LIGHTING OVER TUB/SHOWERS APPEARS TO BE A STANDARD
 RECESS LIGHT. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL
 BE SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC
 410.10(D); FBC RE E4003.11
 10. PROVIDE GFCI WEATHER PROOF RECEPTACLE ON BALCONY
 AND TERRARE AREAS. NEC 210.52(E); FBC RE E3901.7
 11. BREAKER FOR POOL PUMP REQUIRED TO BE GFCI
 PROTECTED. PROVIDE CORRECTION. NEC 680.21(C); FBC RE
 E4203.1.3
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2018-06-04 Cont ID  
Sent By gjohnson Date 2018-06-04 Time 16:43 Rev Time 0.00
Received By gjohnson Date 2018-06-04 Time 16:17 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-05-15 Cont ID  
Sent By fmittner Date 2018-05-15 Time 14:00 Rev Time 0.00
Received By fmittner Date 2018-05-15 Time 14:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-13 Cont ID  
Sent By cthroop Date 2018-06-13 Time 15:32 Rev Time 0.00
Received By cthroop Date 2018-06-12 Time 13:06 Sent To I
Notes
2018-06-13 13:06:40IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-07 Cont ID  
Sent By cthroop Date 2018-06-07 Time 11:07 Rev Time 0.00
Received By cthroop Date 2018-05-01 Time 11:32 Sent To I
Notes
2018-05-02 11:32:35R22

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-06-13 Cont ID  
Sent By cthroop Date 2018-06-13 Time 15:32 Rev Time 0.00
Received By cthroop Date 2018-06-13 Time 15:32 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-06-07 Cont ID  
Sent By cthroop Date 2018-06-07 Time 10:51 Rev Time 0.00
Received By cthroop Date 2018-06-04 Time 16:49 Sent To  
Notes
2018-06-07 11:07:01BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-05-21 Cont ID  
Sent By hmoser Date 2018-05-21 Time 13:50 Rev Time 0.00
Received By hmoser Date 2018-05-21 Time 10:09 Sent To  
Notes
2018-05-21 13:50:28PLAN PASS PROVISO
 1) PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR
 THE
 KITCHEN HOOD AT FIRST INSPECTION. PER SECTION M1503.4
 2017 RESIDENTIAL CODE.
 2) REVISION OR LETTER FROM ENGINEER REQUIRED MISSING
 RETURN AIR
 IN THE DINING ROOM. HAVE LETTER OR REVISION AT FIRST
 INSPECTION.
 SECTION M1602.3 RESIDENTIAL CODE 2017
  
 PLAM REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-06-04 Cont ID  
Sent By gjohnson Date 2018-06-04 Time 16:17 Rev Time 0.00
Received By gjohnson Date 2018-06-04 Time 10:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2018-06-07 Cont ID  
Sent By cthroop Date 2018-06-07 Time 11:07 Rev Time 0.00
Received By cthroop Date 2018-06-04 Time 16:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-05-15 Cont ID  
Sent By fmittner Date 2018-05-15 Time 14:00 Rev Time 0.00
Received By fmittner Date 2018-05-15 Time 14:00 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved