Plan Review Details - Permit 18050008
Plan Review Stops For Permit 18050008
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-01 Cont ID  
Sent By skennedy Date 2018-08-01 Time 15:21 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 14:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-06-05 Cont ID  
Sent By cthroop Date 2018-06-05 Time 17:12 Rev Time 0.00
Received By cthroop Date 2018-06-05 Time 17:01 Sent To  
Notes
2018-06-05 17:19:37BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CORRECT ADDRESS ON PLANS.
 2. PROVIDE 2ND COPY OF WINDOW PRODUCT APPROVALS.
 3. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS.
 4. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 5. SUBMIT ENERGY SUBMITTAL.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW SUBMITTALS.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
 FBC 107.3.5.1.6 ENERGY CALCULATIONS ? PROVIDE AN ENERGY
 SUBMITTAL COMPLIANT WITH FBC-E 103.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-01 Cont ID  
Sent By skennedy Date 2018-08-01 Time 14:43 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 14:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-05-23 Cont ID  
Sent By jpearson Date 2018-05-23 Time 08:56 Rev Time 0.00
Received By jpearson Date 2018-05-23 Time 07:55 Sent To  
Notes
2018-05-23 08:56:56CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE CORRECT ADDRESS ON PLAN. WPB FBC 107.2.1
 2. PROVIDE FLOOR PLAN OF ENTIRE RESIDENCE, SHOWING
 SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER CODE.
 SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE EXISTING
 OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC RE
 R314.3, R315.1; WPB FBC 107.2.1
 3. NOTE 18 DOES NOT MATCH THE CURRENT CODE FOR AFCI
 PROTECTION. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.12; FBC RE E3902.16
 4. NOTE 19 STATES THAT RECEPTACLES SHALL BE TAMPER
 RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT
 APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE
 CORRECTION. NEC 406.12; FBC RE E4002.14
 5. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 6. PLAN IS SHOWING AN OPTIONAL WP GFI RECEPTACLE. A
 GFCI PROTECTED OUTLET FOR SERVICING OF A/C EQUIPMENT IS
 REQUIRED PER CODE. PROVIDE CORRECTION. NEC 210.63; FBC
 RE E3901.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-01 Cont ID  
Sent By skennedy Date 2018-08-01 Time 15:35 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 14:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-06-05 Cont ID  
Sent By cthroop Date 2018-06-05 Time 17:19 Rev Time 0.00
Received By cthroop Date 2018-05-01 Time 10:01 Sent To I
Notes
2018-05-02 10:01:09R10

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-08-14 Cont ID  
Sent By skennedy Date 2018-08-14 Time 16:09 Rev Time 0.00
Received By skennedy Date 2018-08-14 Time 16:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-06-05 Cont ID  
Sent By cthroop Date 2018-06-05 Time 17:11 Rev Time 0.00
Received By cthroop Date 2018-06-05 Time 17:01 Sent To  
Notes
2018-06-05 17:12:01BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-08-14 Cont ID  
Sent By skennedy Date 2018-08-14 Time 16:10 Rev Time 0.00
Received By skennedy Date 2018-08-14 Time 16:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-08-01 Cont ID  
Sent By skennedy Date 2018-08-01 Time 15:24 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 15:24 Sent To  
Notes
2018-08-01 15:34:572ND REVIEW: FBC 2017 6TH ED. RESIDENTIAL
 2ND REVIEW FBC 2017 EXISTING BUILDING
  
 FBC 107 - PROVIDE AN HVAC EQUIPMENT SCHDULE OR
 EQUPIMENT SPECIFICATIONS.
  
 PROVIDE AN EQUIPMENT SIZING CALCULATION:
 R403.6.1 EQUIPMENT SIZING.
 HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN
 ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES, BASED ON BUILDING LOADS FOR THE
 DIRECTIONAL ORIENTATION OF THE BUILDING. THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH
 THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN
 CONDITIONS DESCRIBED IN SECTION R302.1. THIS CODE DOES
 NOT ALLOW DESIGNER SAFETY FACTORS, PROVISIONS FOR
 FUTURE EXPANSION OR OTHER FACTORS WHICH AFFECT
 EQUIPMENT SIZING. SYSTEM SIZING CALCULATIONS SHALL NOT
 INCLUDE LOADS CREATED BY LOCAL INTERMITTENT MECHANICAL
 VENTILATION SUCH AS STANDARD KITCHEN AND BATHROOM
 EXHAUST SYSTEMS.
  
 R403.6.1.1 COOLING EQUIPMENT CAPACITY.
 COOLING ONLY EQUIPMENT SHALL BE SELECTED SO THAT ITS
 TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED TOTAL
 LOAD, BUT NOT MORE THAN 1.15 TIMES GREATER THAN THE
 TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE
 SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE
 SIZE PROVIDED BY THE MANUFACTURER?S PRODUCT LINES. THE
 CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL
 NOT BE LESS THAN THE CALCULATED LATENT LOAD.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-05-17 Cont ID  
Sent By cmontell Date 2018-05-17 Time 14:38 Rev Time 0.00
Received By cmontell Date 2018-05-17 Time 14:37 Sent To  
Notes
2018-05-17 14:38:15NEED CORRECT ADDRESS ON PLANS
  
 CHRIS MONTELLO
 561-805-6733

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-10-18 Cont ID  
Sent By gjohnson Date 2018-10-18 Time 10:30 Rev Time 0.00
Received By gjohnson Date 2018-10-18 Time 10:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2018-08-01 Cont ID  
Sent By skennedy Date 2018-08-01 Time 14:16 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 14:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-06-05 Cont ID  
Sent By thunt Date 2018-06-05 Time 16:51 Rev Time 0.00
Received By thunt Date 2018-06-05 Time 16:51 Sent To  
Notes
2018-06-05 16:56:3606/05/2018 1ST PLUMBING REVIEW**DENIED**
  
 1) ADDRESS ON PLAN 361 COLONY ROAD IS INCORRECT. ACTUAL
 CORRECT ADDRESS AND PER PERMIT APPLICATION IS 361
 COLONIAL RD. FBC 107.2.1
  
 2) VALUE SEEMS LOW. PROVIDED SIGNED BONA FIDE CONTRACT.
 109.3BUILDING PERMIT VALUATIONS.
 THE APPLICANT FOR A PERMIT SHALL PROVIDE AN ESTIMATED
 PERMIT VALUE AT TIME OF APPLICATION. PERMIT VALUATIONS
 SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING MATERIALS
 AND LABOR, FOR WHICH THE PERMIT IS BEING ISSUED, SUCH
 AS ELECTRICAL, GAS, MECHANICAL, PLUMBING EQUIPMENT AND
 PERMANENT SYSTEMS. IF, IN THE OPINION OF THE BUILDING
 OFFICIAL, THE VALUATION IS UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE
 APPLICANT CAN SHOW DETAILED ESTIMATES TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FINAL BUILDING
 PERMIT VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 3) ACCESS TO WASHING MACHINE SHUT OFF VALVE SHALL
 REMAIN. FBC R P2903.9.3
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status N Date 2018-08-01 Cont ID  
Sent By skennedy Date 2018-08-01 Time 14:44 Rev Time 0.00
Received By skennedy Date 2018-08-01 Time 14:44 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By PG Date 2018-05-14 Time   Rev Time 0.00
Received By pgreilic Date 2018-05-11 Time 14:25 Sent To  
Notes
2018-05-14 16:18:431.) PLEASE CORRECT PROJECT ADDRESS ON ALL PLANS
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]