| Plan Review Stops For Permit 18041372 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-05-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-29 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-29 |
Time |
10:10 |
Sent To |
E |
|
| Notes |
| 2018-05-29 10:23:15 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-14 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-14 |
Time |
13:54 |
Sent To |
I |
|
| Notes |
| 2018-05-14 15:40:12 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PROVIDE A STEEL REINFORCING DETAIL FOR THE POOL | | | STEPS. FBC 107.2.1 | | | | | | 2) THE POOL ALARMS ARE REQUIRED TO COMPLY WITH UL 2017, | | | NOT UL 2107. PLEASE CORRECT THE NOTE ON SHEET 3 OF THE | | | DRAWINGS. SEE FBC-R SECTION 4501.17.1.19. | | | | | | 3) ON OCTOBER 5, 2017, THE CITY OF WEST PALM BEACH | | | ADOPTED A (2) TWO FOOT FREEBOARD ABOVE THE BASE FLOOD | | | ELEVATION. ALTHOUGH THIS PROPERTY IS NOT LOCATED IN A | | | SPECIAL FLOOD HAZARD AREA, YOU SHOULD REVISE THE NOTE | | | ON SHEET 3 OF THE DRAWINGS FOR FUTURE SUBMITTAL | | | DOCUMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-30 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-30 |
Time |
07:49 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-10 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-10 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2018-05-10 15:18:36 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH | | | CODE. NEC 210.8, 215.5, 408.4; WPB FBC 107.3.5; FBC RE | | | E3706.2, E3902 | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2018-05-31 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-05-31 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-05-31 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2018-05-31 17:40:33 | NO GAS OR POOL HEATER OF ANY FUEL ON THIS PLAN. TLH |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-13 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-13 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2018-05-13 14:10:04 | SUBMIT MANUF. SPECS FOR THE POOL HEATER. THE PLANS ARE | | | UNCLEAR AS TO WHETHER THE HEATER IS GAS OR ELECTRIC. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-31 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-05-31 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-05-24 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2018-05-25 13:13:26 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-14 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-30 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2018-05-01 14:32:01 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-05-31 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-05-31 |
Time |
17:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-13 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-13 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2018-05-13 14:07:16 | 1) SUBMIT MANUF. SPECIFICATIONS FOR THE POOL HEATER. | | | THE POOL HEATER SHALL COMPLY WITH 2017 FBC-ENERGY CODE | | | SEC. R403.5.6.2 & TABLE C404.2.SHT. 5 - ANSI/APSP/ICC | | | 15 NOTES SEC.4.3.2. - THE 2017 FBC-ENERGY REQUIRES A | | | MINIMUM OF 82% MINIMU EFFICIENCY FOR GAS AND OIL FIRED | | | POOL HEATERS BUT THE NOTE STATES 78%. CLARIFY. | | | 2) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS AS REQUIRED | | | BY APSP-7 2013 SEC. 4.4.9, 4.4.9.1..THE MAXIMUM FLOW OF | | | THE PUMP FROM ITS PUMP CURVE IS NO LONGER ALLOWED TO BE | | | USED IN DETERMINING MAXIMUM SYSTEM FLOW RATE. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-04 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2018-05-04 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2018-05-04 |
Time |
16:32 |
Sent To |
I |
|
| Notes |
|
|