Plan Review Details - Permit 18041372
Plan Review Stops For Permit 18041372
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-05-29 Cont ID  
Sent By rmcdouga Date 2018-05-29 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2018-05-29 Time 10:10 Sent To E
Notes
2018-05-29 10:23:15FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-05-14 Cont ID  
Sent By rmcdouga Date 2018-05-14 Time 15:40 Rev Time 0.00
Received By rmcdouga Date 2018-05-14 Time 13:54 Sent To I
Notes
2018-05-14 15:40:12PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE A STEEL REINFORCING DETAIL FOR THE POOL
 STEPS. FBC 107.2.1
  
 2) THE POOL ALARMS ARE REQUIRED TO COMPLY WITH UL 2017,
 NOT UL 2107. PLEASE CORRECT THE NOTE ON SHEET 3 OF THE
 DRAWINGS. SEE FBC-R SECTION 4501.17.1.19.
  
 3) ON OCTOBER 5, 2017, THE CITY OF WEST PALM BEACH
 ADOPTED A (2) TWO FOOT FREEBOARD ABOVE THE BASE FLOOD
 ELEVATION. ALTHOUGH THIS PROPERTY IS NOT LOCATED IN A
 SPECIAL FLOOD HAZARD AREA, YOU SHOULD REVISE THE NOTE
 ON SHEET 3 OF THE DRAWINGS FOR FUTURE SUBMITTAL
 DOCUMENTS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-05-30 Cont ID  
Sent By jleahy Date 2018-05-30 Time 07:49 Rev Time 0.00
Received By jleahy Date 2018-05-30 Time 07:49 Sent To G
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-05-10 Cont ID  
Sent By jpearson Date 2018-05-10 Time 15:18 Rev Time 0.00
Received By jpearson Date 2018-05-10 Time 15:18 Sent To  
Notes
2018-05-10 15:18:36CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH
 CODE. NEC 210.8, 215.5, 408.4; WPB FBC 107.3.5; FBC RE
 E3706.2, E3902
 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2018-05-31 Cont ID  
Sent By thunt Date 2018-05-31 Time 17:40 Rev Time 0.00
Received By thunt Date 2018-05-31 Time 17:40 Sent To  
Notes
2018-05-31 17:40:33NO GAS OR POOL HEATER OF ANY FUEL ON THIS PLAN. TLH

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-05-13 Cont ID  
Sent By tklarge Date 2018-05-13 Time 14:09 Rev Time 0.00
Received By tklarge Date 2018-05-13 Time 14:09 Sent To  
Notes
2018-05-13 14:10:04SUBMIT MANUF. SPECS FOR THE POOL HEATER. THE PLANS ARE
 UNCLEAR AS TO WHETHER THE HEATER IS GAS OR ELECTRIC.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-05-31 Cont ID  
Sent By thunt Date 2018-05-31 Time 17:40 Rev Time 0.00
Received By thunt Date 2018-05-24 Time 13:13 Sent To  
Notes
2018-05-25 13:13:26RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-05-14 Cont ID  
Sent By rmcdouga Date 2018-05-14 Time 15:40 Rev Time 0.00
Received By rmcdouga Date 2018-04-30 Time 14:31 Sent To  
Notes
2018-05-01 14:32:01ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-05-31 Cont ID  
Sent By thunt Date 2018-05-31 Time 17:40 Rev Time 0.00
Received By thunt Date 2018-05-31 Time 17:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-05-13 Cont ID  
Sent By tklarge Date 2018-05-13 Time 14:07 Rev Time 0.00
Received By tklarge Date 2018-05-13 Time 13:32 Sent To  
Notes
2018-05-13 14:07:161) SUBMIT MANUF. SPECIFICATIONS FOR THE POOL HEATER.
 THE POOL HEATER SHALL COMPLY WITH 2017 FBC-ENERGY CODE
 SEC. R403.5.6.2 & TABLE C404.2.SHT. 5 - ANSI/APSP/ICC
 15 NOTES SEC.4.3.2. - THE 2017 FBC-ENERGY REQUIRES A
 MINIMUM OF 82% MINIMU EFFICIENCY FOR GAS AND OIL FIRED
 POOL HEATERS BUT THE NOTE STATES 78%. CLARIFY.
 2) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS AS REQUIRED
 BY APSP-7 2013 SEC. 4.4.9, 4.4.9.1..THE MAXIMUM FLOW OF
 THE PUMP FROM ITS PUMP CURVE IS NO LONGER ALLOWED TO BE
 USED IN DETERMINING MAXIMUM SYSTEM FLOW RATE.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-05-04 Cont ID  
Sent By ajones Date 2018-05-04 Time 16:32 Rev Time 0.00
Received By ajones Date 2018-05-04 Time 16:32 Sent To I
Notes
***NONE***