| Plan Review Stops For Permit 18041299 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-02 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-02 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2018-07-02 09:45:14 | SHELL ONLY, |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-06-05 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-06-05 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2018-06-05 08:51:07 | SHELL ONLY, |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-18 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-05-18 |
Time |
19:14 |
Sent To |
|
|
| Notes |
| 2018-05-18 19:14:58 | SHELL ONLY, BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- PROVIDE ALL THE WIND DESIGN DATA AS REQUIRED BY SEC. | | | 1603.1.4 FBC. | | | | | | SEC. 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1.ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2.RISK CATEGORY. | | | 3.WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE THAN | | | ONE WIND EXPOSURE IS UTILIZED. | | | 4.APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5.DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF | | | (KN/M2). | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR THE NEW EXTERIOR DOOR #1. | | | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-06-28 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-06-28 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2018-06-28 09:12:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: OK SEE NOTE AND STAMP, SEE | | | COMMENTS BELOW. | | | | | | 1. OK | | | 2. OK | | | 3. PROVIDE AIC RATING OF NEW PANEL. NEC 110.3, 110.9 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 5. | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER, CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-06 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-06-06 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-06-05 |
Time |
15:01 |
Sent To |
P |
|
| Notes |
| 2018-06-06 09:19:22 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. OK | | | 2. RISER DIAGRAM SHOWS A NEW PANEL B, BUT THIS PANEL IS | | | NOT SHOWN ON THE PLAN. SHOW LOCATION OF ALL ELECTRICAL | | | PANELS ON PLAN. ALSO, PROVIDE PANEL SCHEDULE FOR PANEL | | | B WITH A LOAD CALCULATION. WPB FBC 107.2.1; NEC 215.5, | | | 220, 408.4 | | | 3. PROVIDE AIC RATING OF NEW PANEL. NEC 110.3, 110.9 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 5. PROVIDE GFCI PROTECTION FOR DRINKING FOUNTAIN. NEC | | | 422.52 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER, CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-09 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-09 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2018-05-09 13:44:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLANS MUST BE SUBMITTED AS 2 COMPLETE SETS ONE SET | | | IS MISSING THE MECHANICAL DRAWING BUT HAS 2 OF THE SAME | | | ELECTRICAL SHEETS IN THE SAME SET. PROVIDE CORRECTION. | | | WPB FBC 107.2.1 | | | 2. RISER DIAGRAM SHOWS A NEW PANEL B, BUT THIS PANEL IS | | | NOT SHOWN ON THE PLAN. SHOW LOCATION OF ALL ELECTRICAL | | | PANELS ON PLAN. ALSO, PROVIDE PANEL SCHEDULE FOR PANEL | | | B WITH A LOAD CALCULATION. WPB FBC 107.2.1; NEC 215.5, | | | 220, 408.4 | | | 3. PROVIDE AIC RATING OF NEW PANEL. NEC 110.3, 110.9 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 5. PROVIDE GFCI PROTECTION FOR DRINKING FOUNTAIN. NEC | | | 422.52 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-06-27 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-06-27 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-06-04 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-06-04 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-05-01 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-05-01 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2018-05-01 11:52:36 | PERMIT # 18041299 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | APPROVED WITH COMMENTS: | | | | | | 1) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | 2) PERMIT IS FOR SHELL ONLY. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-13 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-25 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-12 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-24 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-18 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-27 |
Time |
14:30 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-05-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-18 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-05-17 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-28 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-28 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-05-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-05-29 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-05-29 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2018-05-29 11:46:08 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18041299 | | | 5/29/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) WIND LOAD ENGINEERING IS REQUIRED FOR INSTALLATION | | | OF THE NEW 5-TON RTU- SECTION 301.15. PLEASE PROVIDE | | | THE DESIGN CRITERIA AND INSTALLATION DETAILS ON THE | | | PLAN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-05-09 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-05-09 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2018-05-09 17:14:43 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18041299 | | | 5/9/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS C-1 & 4.0M: MECHANICAL NOTES #1 & #5 ON C-1 | | | SEEM TO INDICATE (3) 5-TON AC SYSTEMS WILL BE | | | INSTALLED, HOWEVER THE PLAN SHOWS (2). | | | | | | 2) REPLACEMENT OF THE AC SYSTEMS ARE NOT EXACT SAME | | | SIZE REPLACEMENTS SO COOLING AND HEATING CALCULATIONS | | | ARE REQUIRED TO VERIFY ACCURATE SIZING- SECTION | | | C403.2.1 FBC-14 ENERGY CONSERVATION. | | | | | | 3) 4.0M: PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION | | | OF THE NEW ROOFTOP UNITS ON THE EXISTING CURBS. IF | | | USING CURB ADAPTERS PLEASE INCLDUE THEM IN THE DETAILS | | | AND SUBMIT SPECS- SECTION 301.15 FBC-17 MECHANICAL. | | | | | | 4) SHEET C-1, NOTE 3 & SHEET 4.0M: SHOW THE LOCATIONS | | | OF THE ROOFTOP HOODS AND PROVIDE CAPPING DETAILS. | | | | | | 5) 4.0M: DUCT SMOKE DETECTORS ARE REQUIRED IN THE | | | SUPPLY SYSTEMS OF THE NEW 5-TON RTU'S , UNLESS | | | MANUFACTURER'S SPECIFICATIONS INDICATE THE SYSTEMS | | | CANNOT PRODUCE OVER 2000 CFMS OF SUPPLY AIR- SECTION | | | 606.2.1. | | | | | | 6) ONE SET OF PLANS IS MISSING THE 4.0M SHEET. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-13 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-13 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-12 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-12 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2018-06-12 14:48:44 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED WITH | | | | | | 1. PLEASE PROVIDE WATER ISOMETRIC DRAWING. AMEND TO FBC | | | 107.3.5.1.3(3)(13) | | | | | | 2. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA PER FBC PL 416.5 | | | | | | 3. IS THE WATER HEATER EXISTING IF NEW PROVIDE | | | MANUFACTURE SPECS. PER AMEND TO FBC 107.2.1 | | | | | | NEW COMMENT THE NEW WATER FOUNTAIN SHALL CONNECT DOWN | | | STREAM OF THE BATHROOM GROUP. PER FBC PL 912.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-17 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-17 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2018-05-17 13:46:36 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE WATER ISOMETRIC DRAWING. AMEND TO FBC | | | 107.3.5.1.3(3)(13) | | | | | | 2. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA PER FBC PL 416.5 | | | | | | 3. IS THE WATER HEATER EXISTING IF NEW PROVIDE | | | MANUFACTURE SPECS. PER AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-07-12 |
Time |
09:58 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-07-02 |
Time |
10:28 |
Sent To |
P |
|
| Notes |
| 2018-07-12 09:58:48 | PROPOSED REPLACEMENT A/C IS SMALLER THAN EXISTING UNIT, | | | SO IT IS A LOWER PROFILE, REDUCING THE NON-CONFORMITY. | | | PAINT UNIT WITH SKY PATTERN AS SCREENING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-05-31 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-05-31 |
Time |
15:24 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-05-31 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2018-05-31 15:27:12 | FAILED | | | | | | 1) REPEAT COMMENT: RESOLUTION NO. 358-16 REQUIRES THAT | | | WITHIN VILLAGE COMMONS, ALL NEW MECHANICAL EQUIPMENT, | | | WHETHER GROUND OR ROOF MOUNTED, MUST BE SCREENED FROM | | | VIEW OF THE PUBLIC. PLEASE PROVIDE VERIFICATION THAT | | | THE NEW 5 TON ROOF MOUNTED RTU MEETS THIS REQUIREMENT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-05-15 |
Time |
10:50 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-05-15 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2018-05-15 10:50:11 | FAILED | | | | | | 1) RESOLUTION NO. 358-16 REQUIRES THAT WITHIN VILLAGE | | | COMMONS, ALL NEW MECHANICAL EQUIPMENT, WHETHER GROUND | | | OR ROOF MOUNTED, MUST BE SCREENED FROM VIEW OF THE | | | PUBLIC. PLEASE PROVIDE VERIFICATION THAT THE TWO NEW | | | ROOF MOUNTED RTU(S) MEET THIS REQUIREMENT. | | | | | | 2) SHEET 4.0M (ONLY ONE PROVIDED) DOES NOT SHOW THE | | | TENANT BAY THAT IS PART OF THIS PERMIT, BUT RATHER THE | | | ADJACENT TENANT BAY (PERMIT 18041305). ALL PERMITS MUST | | | SHOW ACCURATE LOCATION. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|