Plan Review Details - Permit 18041270
Plan Review Stops For Permit 18041270
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-06-04 Cont ID  
Sent By shill Date 2018-06-04 Time 12:04 Rev Time 0.00
Received By shill Date 2018-06-04 Time 12:04 Sent To  
Notes
2018-06-04 12:04:45TILE FLOORING W/SUPERSIM90 UNDERLAYMENT PER TELEPHONE
 CONVERSATION WITH CONTRACTOR
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-05-22 Cont ID  
Sent By shill Date 2018-05-22 Time 10:58 Rev Time 0.00
Received By shill Date 2018-05-22 Time 10:58 Sent To  
Notes
2018-05-22 11:00:54****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE
 PROPOSED? PLEASE ADVISE VIA EMAIL. IF THE UNDERLAYMENT
 PRODUCT PROPOSED IS NOT ONE FOR WHICH WE HAVE TEST
 REPORTS ON FILE, THE FOLLOWING REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
 2. PROVIDE A CONTRACT OR COST BREAKDOWN FOR THIS
 PROJECT, FBC 109. VALUE IS TO INCLUDE LABOR, MATERIALS,
 OVERHEAD AND PROFIT, INCLUDING MATERIALS PROVIDED BY
 OTHERS.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-05-20 Cont ID  
Sent By jpearson Date 2018-05-20 Time 09:11 Rev Time 0.00
Received By jpearson Date 2018-05-20 Time 09:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-05-01 Cont ID  
Sent By scaldero Date 2018-05-01 Time 11:44 Rev Time 0.00
Received By scaldero Date 2018-05-01 Time 11:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-05-22 Cont ID  
Sent By shill Date 2018-05-22 Time 11:14 Rev Time 0.00
Received By shill Date 2018-04-27 Time 15:47 Sent To  
Notes
2018-04-30 15:47:27B19

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-05-10 Cont ID  
Sent By hmoser Date 2018-05-10 Time 11:15 Rev Time 0.00
Received By hmoser Date 2018-05-10 Time 11:13 Sent To  
Notes
2018-05-10 11:15:16CALLED CONTRACTOR NO AIR CONDITIONING WORK AT THIS
 TIME. HM.

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-05-22 Cont ID  
Sent By tklarge Date 2018-05-22 Time 11:12 Rev Time 0.00
Received By tklarge Date 2018-05-22 Time 11:12 Sent To  
Notes
***NONE***