| Plan Review Stops For Permit 18041175 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-06 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-06 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-20 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-20 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2018-07-20 15:53:52 | SEE COMMENTS FROM 18041063 (MAIN HOUSE) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-22 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-22 |
Time |
09:56 |
Sent To |
I |
|
| Notes |
| 2018-06-22 12:55:37 | SEE REVIEW COMMENTS UNDER 18041063. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2018-05-14 16:13:12 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SOILS REPORT WITH ORIGINAL SIGNATURE AND | | | SEAL OF FLORIDA LICENSED PROFESSIONAL ENGINEER. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | 3. PROVIDE ICC-ES REPORT FOR ICYNENE INSULATION. SELECT | | | PRODUCT TO BE INSTALLED TO OBTAIN THE R-30 RATING PER | | | APPROVED PLANS. | | | R402.1.1 INSULATION AND FENESTRATION CRITERIA. | | | | | | 4. PROVIDE LANDINGS AT EXTERIOR DOORS AND STAIR | | | LANDINGS. | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE | | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | | MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE | | | DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE | | | PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT | | | VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT). | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-20 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-20 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2018-07-20 11:15:49 | APPROVED WITH PROVISO ON PLAN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-06-08 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-06-08 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2018-06-08 11:27:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 3. NOTE 16 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. ADDITIONALLY, | | | THIS IS NOT THE CURRENT CODE. PROVIDE CORRECTION. NEC | | | 406.12; FBC RE E4002.14 | | | 4. OK | | | 5. OK | | | 6. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 7. IS EXISTING SERVICE BEING USED AS IS, OR BEING | | | UPGRADED? PLAN DOES NOT SPECIFY. IF UPGRADING, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH PANEL | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, | | | 110.10 | | | 8. OK | | | 9. OK | | | 10. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 11. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 12. IDENTIFY ALL LOCATION OF ELECTRICAL PANELS ON PLAN. | | | FBC 107.2.1 | | | | | | DUE TO EXCESSIVE LACK OF INFORMATION ON ELECTRICAL | | | PLAN, FURTHER PLAN REVIEW COMMENTS ARE LIKELY. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER, CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-07 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-07 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2018-05-07 11:07:48 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 3. NOTE 16 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. ADDITIONALLY, | | | THIS IS NOT THE CURRENT CODE. PROVIDE CORRECTION. NEC | | | 406.12; FBC RE E4002.14 | | | 4. PROVIDE AN OUTLET FOR ANY WALL SPACE 24 INCHES OR | | | GREATER WHERE REQUIRED TO MEET WALL SPACING | | | REQUIREMENTS. PROVIDE CORRECTION. NEC 210.52; FBC RE | | | E3901.2.1 | | | 5. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | 6. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 7. IS EXISTING SERVICE BEING USED AS IS, OR BEING | | | UPGRADED? PLAN DOES NOT SPECIFY. IF UPGRADING, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH PANEL | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, | | | 110.10 | | | 8. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 9. GFCI PROTECTION IS REQUIRED FOR ALL OUTLETS IN | | | GARAGE, INCLUDING GARAGE DOOR OPENER. PROVIDE | | | CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 10. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 11. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 12. IDENTIFY ALL LOCATION OF ELECTRICAL PANELS ON PLAN. | | | FBC 107.2.1 | | | | | | DUE TO EXCESSIVE LACK OF INFORMATION ON ELECTRICAL | | | PLAN, FURTHER PLAN REVIEW COMMENTS ARE LIKELY. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-02 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-02 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-26 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-28 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2018-06-28 16:01:34 | R30 | | | *TRAVELLING WITH 18041063* |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-22 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-01 |
Time |
15:10 |
Sent To |
I |
|
| Notes |
| 2018-06-04 15:10:41 | R24 | | | **TRAVELLING WITH 18041063** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-23 |
Time |
14:29 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2018-05-14 16:14:21 | NO NOTES | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-05-02 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-05-02 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-26 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-26 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2018-07-26 13:46:43 | 07/26/18 DENIED GAS, PLUMBING APPROVED SENT TO | | | PROCESSING, LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-06-13 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-13 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2018-06-13 07:30:31 | 06/13/18 DENIED GAS, PLUMBING APPROVED PUT BACK IN | | | R24,LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-05-08 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-05-08 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2018-05-08 08:28:01 | 05/07/18 DEINIED BY PLUMBING AND COMENTS ON PERMIT | | | 18041063, LAC |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-06 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-06 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-22 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-22 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2018-06-22 10:00:21 | SEE COMMENTS ON 18041063. CT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-02 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-02 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|