Plan Review Details - Permit 18041162
| Plan Review Stops For Permit 18041162 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-14 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-14 |
Time |
17:22 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-10 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-10 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-13 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-13 |
Time |
14:14 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-04 |
Time |
03:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-04 |
Time |
03:16 |
Sent To |
I |
|
| Notes |
| 2018-06-04 03:54:50 | 1) SHOW THE DISTANCE FROM THE OUTLET OF THE GAS METER | | | TO THE INLET OF THE MP REGULATOR FOR THE EXISTING | | | INTERIOR LOAD ON THAT SECTION.2017 FBC-FUEL GAS SEC. | | | 402.4.1. | | | 2) LIST THE EXISTING GAS FIXTURES ON THE PLAN AND THE | | | CORRESPONDING BTU LOAD FOR EACH APPLIANCE. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 3) SHOW THE DISTANCE FROM THE OUTLET OF THE MP | | | REGULATOR TO THE MOST REMOTE OUTLET ON THE INTERIOR | | | SECTION OF THE SYSTEM.2017 FBC-FUEL GAS SEC.402.4.1. | | | THE EXISTING GAS PLANS ON FILE AT THE CITY SHOW THE | | | MOST REMMOTE OUTLET AT 83 FEET FROM THE METER. CLARIFY. | | | 4) THE SHUTOFF VALVE ON THE EXISTING PIPING TO THE | | | INTERIOR SHALL BE LOCATED IMMEDIATELY AHEAD OF THE | | | REGULATOR PER 2017 FBC-FUEL GAS SEC. 409.4. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-13 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-13 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2018-05-13 12:43:23 | | | | 1) SHOW THE TYPE OF PIPE AND PIPE SIZE AT THE OUTLET OF | | | THE 2 PSI METER . WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) SHOW THE PIPE SIZE OF THE SECTION OF PIPE TO THE | | | REGULATOR SERVING THE EXISTING GAS LOAD.WPB AMEND. TO | | | FBC SEC. 107.2.1. | | | 3) SHOW THE TYPE OF PIPE AND PIPE SIZE DOWNSTREAM OF | | | THE REGULATOR FOR THE EXISTING GAS LOADS AND NOTE THE | | | DISTANCE FROM THIS REGULATOR TO THE FURTHEST OUTLET ON | | | THAT SYSTEM.WPB AMEND. TO FBC SEC. 107.2.1. | | | 4) A LISTED SHUTOFF VALVE IS REQUIRED IMMEDIATELY AHEAD | | | OF THE MP REGULATOR FOR THE EXISTING LOADS.. 2017 FBCR | | | SEC. G2420.4. | | | 5) SPECIFY ON THE GAS DRAWING HOW THE 3/4 INCH | | | GALVANIZED IS GOING TO BE INSTALLED. ABOVE-GROUND | | | PIPING OUTDOORS SHALL COMPLY WITH 2017 FBCR | | | SEC.G2415.9, G2415.11. | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE FLEX | | | CONNECTOR FOR THE GENERATOR. THE FLEX CONNECTOR SHALL | | | BE APPROVED TO FLOW THE MAXIMUM BTU LOAD FOR THE | | | GENERATOR. 2017 FBCR SEC. G2422.1 (8). | | | 7) THE SEDIMENT TRAP AS DRAWN DOES NOT COMPLY WITH 2017 | | | FBCR SEC.G2419.4. | | | 8) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION SHEETS FOR THE REGULATORS. REGULATORS | | | INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE | | | APPROVED FOR OUTDOOR INSTALLATION. 2017 FBCR | | | SEC.G2421.1, FBC-FUEL GAS SEC. 410.1. | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-06-04 |
Time |
03:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-29 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2018-05-30 14:01:44 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-14 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-25 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2018-04-26 13:31:10 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2018-05-02 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2018-05-02 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
|