Plan Review Details - Permit 18041111
| Plan Review Stops For Permit 18041111 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-14 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-14 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2018-07-14 12:49:48 | DETAIL & SCOPE IS ON PERMIT 18030126 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-22 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-22 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2018-05-22 16:12:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, PROVIDE A DETAIL FOR THE ENLARGED | | | EXTERIOR OPENING (SINGLE DOOR TO DOUBLE DOOR); INCLUDE | | | WIND DESIGN CRITERIA (MINIMUM 170MPH EXPOSURE C). | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-07-26 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-07-26 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2018-07-26 14:59:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: OK, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED | | | 8. CORRECTED. | | | 9. CORRECTED | | | | | | NEW COMMENTS: | | | | | | 10. CORRECTED | | | 11. CORRECTED | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-29 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-29 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2018-06-29 12:56:38 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. ANY MODIFICATION OF BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED. PROVIDE CORRECTION. NEC 210.12; FBC RE | | | E3902.16 (AFCI NOTE PROVIDED DOES NOT COVER ALL AREAS | | | THAT REQUIRE AFCI PROTECTION AS NOTED ABOVE. PROVIDE | | | CORRECTION.) | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | RE R314.3, R315.1; WPB FBC 107.2.1 (SMOKE ALARMS MUST | | | BE INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3(4), NFPA | | | 72:29.8.3.4) | | | 8. CORRECTED. | | | 9. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 (ONE OF THE BATHROOMS SHOWS ONLY ONE | | | GFCI RECEPTACLE, BUT THERE ARE TWO BASINS. THE | | | RECEPTACLE SHOWN IS NOT WITHIN THREE FEET OF THE SECOND | | | BASIN. PROVIDE CORRECTION.) | | | | | | NEW COMMENTS: | | | | | | 10. RECEPTALCE FOR GARAGE DOOR OPENER REQUIRES GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.2 | | | 11. PANEL SCHEDULE SHOWS ONLY ONE SMALL APPLIANCE | | | CIRCUIT. A MINIMUM OF TWO SMALL APPLIANCE CIRCUITS ARE | | | REQUIRED FOR KITCHEN COUNTER RECEPTACLES. PROVIDE | | | CORRECTION. NEC 210.11(C)(1); FBC RE E3703.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-17 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-17 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2018-05-17 13:57:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 2. ANY MODIFICATION OF BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED. PROVIDE CORRECTION. NEC 210.12; FBC RE | | | E3902.16 | | | 3. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 4. PROVIDE RECEPTACLE OUTLETS IN KITCHEN SPACED PER | | | CODE. RECEPTACLES IN KITCHEN REQUIRE GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.6 | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 6. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | | FBC RE E3903.3 | | | 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | RE R314.3, R315.1; WPB FBC 107.2.1 | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 9. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-07-26 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-07-25 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2018-07-26 14:31:39 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-18 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-26 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-22 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-24 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-07-16 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-07-16 |
Time |
14:39 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-05-08 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-05-08 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2018-05-08 13:50:02 | MECHANCIAL PLAN REVIEW FAIL | | | | | | NO MECHANICAL PLANS | | | | | | 1- [A]107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHERE APPROVED BY THE | | | BUILDING OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-18 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-17 |
Time |
14:21 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-05-21 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-05-21 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
|