 |
Plan Review Details - Permit 18041063
| Plan Review Stops For Permit 18041063 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-06 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-06 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-20 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-20 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2018-07-20 15:49:53 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18041063 & 18041175 (MAIN HOUSE AND | | | GARAGE) | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1.OK | | | | | | 2.DRAINAGE PLAN PROVIDED NEEDS TO SHOW NUMERIC CHANGES | | | IN ELEVATION THAT MEET REQUIRMENTS IN R401.3 | | | [FBC 107.3.5.3]LOWEST FINISHED FLOOR ELEVATION NEEDS TO | | | BE ESTABLISHED SINCE IT IS NOT ON SURVEY OR PLANS. | | | PIPING FROM SCUPPERS IS NOT REQUIRED IF GRADE WILL | | | PROVIDE PROPER DRAINAGE. IF PIPING IS USED WE NEED TO | | | SEE HOW IT IS PITCHED AND HOW IT RELEASES TO THE | | | STREET. | | | 2-2. NO ELEVATIONS WERE PROVIDED. PLEASE ESTABLISH THE | | | LOWEST FLOOR ELEVATION AND SUPPLY ELEVATIONS THAT WILL | | | HELP US DETERMINE IF YOU ARE MEETING DRAINAGE | | | REQUIREMENTS. THE EAST PROPERTY LINE, THE LOWEST FLOOR, | | | THE TOP OF WALL, THE SIDEWALK AND THE STREET DRAIN | | | WOULD BE A GOOD STARTING POINT. ALL ELEVATIONS SHOULD | | | BE IN NAVD88. | | | | | | 3-09 OK | | | | | | 10.[ENERGY (RE402.1.2]THE ENERGY CALCS PROVIDED SHOW | | | THE WALLS TO BE RATED AT R-14 WITH INT INSULATION. HOW | | | WILL THIS R-RATING BE ACHIEVED AND PROVIDE THE | | | DOCUMENTATION OF THE PRODUCT. ADJUST PLANS AND ENERGY | | | CALCULATIONS TO MATCH. | | | 10-2. THE INSULATION SPEC PROVIDED WOULD NOT BE ABLE TO | | | ACHIEVE THE R-VALUE INDICATED IN THE ENERGY | | | CALCULATIONS. PLEASE UPDATE THE ENERGY CALCULATIONS TO | | | BE BASED ON WHAT WILL BE PROVIDED FOR WALL R-VALUE. | | | | | | 11-18 OK | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF ADDITIONAL MATERIALS REQUESTED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-22 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-22 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2018-06-22 12:52:49 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC R = FBC RESIDENTIAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.OK | | | | | | 2.DRAINAGE PLAN PROVIDED NEEDS TO SHOW NUMERIC CHANGES | | | IN ELEVATION THAT MEET REQUIRMENTS IN R401.3 | | | [FBC 107.3.5.3]LOWEST FINISHED FLOOR ELEVATION NEEDS TO | | | BE ESTABLISHED SINCE IT IS NOT ON SURVEY OR PLANS. | | | PIPING FROM SCUPPERS IS NOT REQUIRED IF GRADE WILL | | | PROVIDE PROPER DRAINAGE. IF PIPING IS USED WE NEED TO | | | SEE HOW IT IS PITCHED AND HOW IT RELEASES TO THE | | | STREET. | | | | | | 3.THE REPORT PROVIDED IS GOOD, BUT PLEASE CHOOSE ONLY | | | ONE TYPE OF ICYNENE. IT IS EITHER CLASSIC OR CLASSIC | | | PLUS BECAUSE THEY REQUIRE DIFFERENT THICKNESS TO | | | ACHIEVE R-30. | | | | | | NEW COMMENTS BELOW FROM FULL REVIEW: | | | | | | 4.[FBC R301]CHANGE ADDRESS ON SURVEY TO SAY 620 PARK | | | PLACE ON BOTH SURVEY SHEETS. THE SURVEYOR PUT 618 ON | | | THE SHEET SHOWING HOUSE LAYOUT. | | | | | | 5.[FBC R311.3.1]EGRESS LANDING SHALL NOT BE LESS THAN 1 | | | 1/2" LOWER THAN THE TOP OF THRESHOLD. PROVIDE DIMENSION | | | ON SECTION TO SHOW HOW YOU ARE MEETING CODE PROVISION. | | | | | | 6.[FBC 107.3.5.3]SHOW SECTION CUTS ON PLAN SHEET A-1 TO | | | CORRESPOND TO SECTIONS ON SHEET A-6, ADD NORTH ARROW TO | | | A-1, ADD ELEVATION CALLOUTS ON A-1 TO CORRESPOND TO | | | ELEVATION SHEET A-2, ADD ROOF PITCH TO ELEVATIONS AND | | | SECTIONS AND CONSIDER ADDING WINDOW DESIGNATIONS TO | | | ELEVATION SHEET A-2 TO MATCH DESIGNATIONS ON PLAN SHEET | | | A-1. | | | | | | 7.[FBC R318]INDICATE THE MEANS OF TERMITE PROTECTION | | | PROPOSED AND REFERENCE SECTION R308 FOR STANDARDS. | | | | | | 8.[FBC R308.1]ADD NOTE FOR SHOWER ENCLOSURES TO COMPLY | | | WITH SAFETY GLASS STANDARDS. | | | | | | 9.[FBC R403.1(3) ADD NOTE TO SECTIONS SHOWING | | | REINFORCING TO PROVIDE MINIMUM COVER OF 3" FOR | | | REINFORCING BARS. | | | | | | 10.[ENERGY (RE402.1.2]THE ENERGY CALCS PROVIDED SHOW | | | THE WALLS TO BE RATED AT R-14 WITH INT INSULATION. HOW | | | WILL THIS R-RATING BE ACHIEVED AND PROVIDE THE | | | DOCUMENTATION OF THE PRODUCT. ADJUST PLANS AND ENERGY | | | CALCULATIONS TO MATCH. | | | | | | NOTICE OF ACCEPTANCE (N.O.A.): | | | | | | 11.PRINT DRAWING SHEETS IN LANDSCAPE FORMAT TO FIT THE | | | PAGE BETTER. SOME ARE LEDIBLE, BUT SOME PRESSURE CHARTS | | | ARE TOO HARD TO READ. | | | THIS APPLIES TO NOA 17-1023.09, 17-0630.08 AND | | | 17-0614.14. | | | | | | 12.PROVIDE 2 COPIES OF N.O.A. FOR INTENDED MULL BAR TO | | | BE USED IN BEDROOM, OFFICE, MASTER BATH AND VERIFY IF | | | MULL IS BEING USED IN GARAGE 2ND FL WEST ELEVATION. THE | | | ELEVATION SHOWS DIFFERENT THAN THE PLAN LOFT WEST ELEV. | | | 2ND FL. WINDOWS. | | | | | | 13.HIGHLIGHT ANCHOR OPTION FOR APPLICABLE BUILDING | | | SYSTEM BEING USED ON WINDOW AND DOOR N.O.A.'S. | | | | | | 14.N.O.A. 14-0506.02 IS MISSING PRESSURE DATA. PLEASE | | | INSERT MISSING SHEET(S). ALSO, CHECK THAT THIS IS THE | | | INTENDED DOOR TYPE FOR THE SINGLE DOORS. THE DOOR | | | SCHEDULE CALLS OUT HOLLOW METAL DOORS BUT THE N.O.A IS | | | FOR FIBERGLASS. UPDATE DOOR SCEDULE TO MATCH N.O.A. | | | BEING USED. | | | | | | 15.SELECT WHICH TYPE OF UNDERLAYMENT IS TO BE INSTALLED | | | PER N.O.A 15-0410.04. | | | | | | ROOFING COMMENTS: | | | | | | 16.[FBC R903.2.1] SUBMIT FLASHING TYPE, GAGE AND | | | ATTACHMENT DETAILS. PROVIDE SCUPPER DETAIL, SIZE AND | | | ROOF AREA CALCULATION FOR FLAT ROOF DRAINAGE. | | | | | | 17.[FBC R903.4]PROVIDE DRAINAGE SLOPE FOR FLAT ROOF. | | | | | | 18.[FBC R905.3.8]SUBMIT FLASHINF TYPE AND ATTACHMENT | | | FOR CLAY TILE ROOF. | | | | | | 19. [FBC R302.6] GARAGE SPACE TO BE SEPARATED FROM | | | HABITABLE SPACE ABV. BY NOT LESS THAN 5/8-IN. TYPE X | | | GYPSUM BOARD OR EQUIVALENT. | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF ADDITIONAL MATERIALS REQUESTED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2018-05-14 16:10:34 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SOILS REPORT WITH ORIGINAL SIGNATURE AND | | | SEAL OF FLORIDA LICENSED PROFESSIONAL ENGINEER. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | 3. PROVIDE ICC-ES REPORT FOR ICYNENE INSULATION. SELECT | | | PRODUCT TO BE INSTALLED TO OBTAIN THE R-30 RATING PER | | | APPROVED PLANS. | | | R402.1.1 INSULATION AND FENESTRATION CRITERIA. | | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | | REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE | | | ZONE SPECIFIED IN CHAPTER 3. | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-07-19 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-20 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2018-07-19 10:45:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 3. NOTE 16 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. ADDITIONALLY, | | | THIS IS NOT THE CURRENT CODE. PROVIDE CORRECTION. NEC | | | 406.12; FBC RE E4002.14 | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 9. IS EXISTING SERVICE BEING USED AS IS, OR BEING | | | UPGRADED? PLAN DOES NOT SPECIFY. IF UPGRADING, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH PANEL | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, | | | 110.10 | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK. | | | 14. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 15. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 16. IDENTIFY ALL LOCATION OF ELECTRICAL PANELS ON PLAN. | | | FBC 107.2.1 | | | 17. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 18. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | | FBC RE E3903.3 | | | 19. OK | | | DUE TO EXCESSIVE LACK OF INFORMATION ON ELECTRICAL | | | PLAN, FURTHER PLAN REVIEW COMMENTS ARE LIKELY. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER ,CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-06-08 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-06-08 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2018-06-08 10:22:01 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 3. NOTE 16 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. ADDITIONALLY, | | | THIS IS NOT THE CURRENT CODE. PROVIDE CORRECTION. NEC | | | 406.12; FBC RE E4002.14 | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 9. IS EXISTING SERVICE BEING USED AS IS, OR BEING | | | UPGRADED? PLAN DOES NOT SPECIFY. IF UPGRADING, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH PANEL | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, | | | 110.10 | | | 10. OK | | | 11. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 12. OK | | | 13. OK. | | | 14. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 15. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 16. IDENTIFY ALL LOCATION OF ELECTRICAL PANELS ON PLAN. | | | FBC 107.2.1 | | | 17. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 18. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | | FBC RE E3903.3 | | | 19. ADDRESS ON PLAN NOT ON PERMIT APPLICATION. | | | DUE TO EXCESSIVE LACK OF INFORMATION ON ELECTRICAL | | | PLAN, FURTHER PLAN REVIEW COMMENTS ARE LIKELY. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER ,CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-03 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-03 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2018-05-03 17:09:41 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | 3. NOTE 16 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. ADDITIONALLY, | | | THIS IS NOT THE CURRENT CODE. PROVIDE CORRECTION. NEC | | | 406.12; FBC RE E4002.14 | | | 4. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | 5. PROVIDE AN OUTLET FOR ANY WALL SPACE 24 INCHES OR | | | GREATER WHERE REQUIRED TO MEET WALL SPACING | | | REQUIREMENTS. PROVIDE CORRECTION. NEC 210.52; FBC RE | | | E3901.2.1 | | | 6. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | 7. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 8. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 9. IS EXISTING SERVICE BEING USED AS IS, OR BEING | | | UPGRADED? PLAN DOES NOT SPECIFY. IF UPGRADING, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH PANEL | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, | | | 110.10 | | | 10. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 11. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 12. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 13. PER CODE: LIGHTING WITH OPEN OR PARTIALLY ENCLOSED | | | LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT | | | BE PERMITTED IN CLOTHES CLOSETS. PROVIDE CORRECTION. | | | NEC 410.16; FBC RE E4003.12 | | | 14. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 15. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 16. IDENTIFY ALL LOCATION OF ELECTRICAL PANELS ON PLAN. | | | FBC 107.2.1 | | | 17. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 18. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | | FBC RE E3903.3 | | | | | | DUE TO EXCESSIVE LACK OF INFORMATION ON ELECTRICAL | | | PLAN, FURTHER PLAN REVIEW COMMENTS ARE LIKELY. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-26 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-26 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2018-07-26 13:33:35 | 07/26/18 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-06-13 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-13 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2018-06-13 07:19:00 | 2ND GAS REVIEW**DENIED** WITH COMMENTS NOTE - A | | | COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME AND | | | ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED UPON | | | THE RE-REVIEW OF SUBMITTED CORRECTIONS. SOME COMMENT | | | MAY NOT APPLY BUT ARE PROVIDED FOR REFERENCES. | | | | | | 1. WATER HEATER WILL REQUIRE A SEPARATE IGNITION SOURCE | | | AND IT IS BEING LABELED ON AS A ELECTRICAL LOAD, PLEASE | | | REMOVE AND ADD A SEPARATE CIRCUIT FOR IGNITION ON | | | TANKLESS, WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | 2. A SECOND REQUEST FOR FIREPLACE ON MANUFACTURES | | | SPECIFICATION, FBC FG R2434.1 GENERAL. | | | 3. SHOW 2 PSI REGULATOR ON ISOMETRIC AND ALL REGULATORS | | | DOWNSTREAM, SHOW THE LOCATION OF ALL MP (STEP-DOWN) | | | REGULATORS. A LISTED SHUTOFF VALVE SHALL BE INSTALLED | | | IMMEDIATELY AHEAD OF EACH MP REGULATOR ON ISOMETRIC. | | | 2017 FBC FUEL GAS RES. SEC. G2420.4. SUBMIT | | | MANUFACTURER?S SPECIFICATIONS FOR THE PRESSURE | | | REGULATORS. REGULATORS INSTALLED ON THE EXTERIOR OF THE | | | BUILDING SHALL BE APPROVED FOR OUTDOOR INSTALLATION. | | | 2017 FBC FUEL GAS RES. SEC. G2421.1. | | | 4. TYPE OF GAS (LP OR NATURAL) NEED TO BE LABELED ON | | | ISOMETRIC. WPB AMENDMENTS TO THE FBC SEC. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | 5. SECOND REQUEST, PLEASE SUBMIT A DETAIL SHOWING THE | | | TYPE, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | 2017 FBC FUEL GAS SECS. 502 THRU 505 OR 2017 FBC FUEL | | | GAS RES. SECS. G2426 THRU G2429.1 | | | 6. SECOND REQUEST, PLEASE SUBMIT TWO COPIES OF THE | | | APPLICABLE SIZING TABLES USED TO SIZE THE GAS SYSTEM OR | | | PLACE A NOTE ON THE PLANS/DRAWINGS SPECIFYING WHICH | | | SIZING TABLE(S) FROM THE GAS CODE OR ANOTHER STANDARD | | | THAT WAS USED IN THE DESIGN OF THIS GAS SYSTEM. REFER | | | TO THE 2017 FBC FUEL GAS RES. SEC. G2412.4, G2412.8, | | | G2413.1, G2413.2, & G2413.3. | | | 7. SECOND REQUEST, SUBMIT COMBUSTION AIR CALCULATIONS | | | FOR DRYER GAS APPLIANCES. WHERE IS COMBUSTION AIR | | | PROVIDED BY THE BUILDING?S MECHANICAL VENTILATION | | | SYSTEM, THE SYSTEM SHALL PROVIDE THE SPECIFIED | | | COMBUSTION AIR RATE IN ADDITION TO THE REQUIRED | | | VENTILATION AIR? 2017 FBC R G2407.9.3. COMBINED | | | COMBUSTION AIR AND VENTILATION AIR SYSTEM. | | | | | | 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS NOTE - A | | | COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME AND | | | ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED UPON | | | THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-05-08 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-05-05 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2018-05-08 08:20:10 | 1ST GAS REVIEW**DENIED** WITH COMMENTS NOTE - A | | | COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME AND | | | ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED UPON | | | THE RE-REVIEW OF SUBMITTED CORRECTIONS. SOME COMMENT | | | MAY NOT APPLY BUT ARE PROVIDED FOR REFERENCES. | | | | | | 1. THERE IS A GAS OVEN, STOVE, TANKLESS WATER HEATER. A | | | DRYER ON THE PLAN IS IT NOT LABELED AS GAS AND THERE IS | | | NO ELECTRIC CIRCUIT ASSIGNED TO IT. IF IT IS GAS PLEASE | | | CLARIFY BY LABELING ON PLAN, PAGE A-7. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. SUBMIT MANUFACTURER?S | | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH 2017 FBC FUEL GAS | | | RES. SEC. G2408.1. | | | | | | 2. THE FIREPLACE IS IT WOOD BURNING OR FUEL, PLEASE | | | PROVIDE MANUFACTURE SPECIFICATION AND IS IT A VENTED | | | FIREPLACE, FBC FG R2434.1 GENERAL. | | | | | | 3. SUBMIT TWO COPIES FOR INSTALLATION CLEARANCES FROM | | | THE TANKLESS INSTALLATION MANUAL. THE MANUAL REQUIRES A | | | CLEARANCE OF EITHER 4 FEET OR 12 INCHES FROM ANY | | | OPERABLE WINDOWS OR DOORS. SHOW THE LOCATION OF ALL | | | OPERABLE WINDOWS AND DOORS ON THE PLAN AND THE DISTANCE | | | OF THE TANKLESS WATER HEATER FROM EACH. WPB AMENDMENTS | | | TO THE FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 4. SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2017 FBC FUEL GAS RES. TABLE | | | G2413.4 (12) SCHEDULE 40 METALLIC PIPE FOR THE PROPER | | | PIPE SIZE AND BTU LOAD. | | | | | | 5. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC FUEL | | | GAS RES SECS. G2413.4.1, G2413.4.2. | | | | | | 6. GAS RISER DIAGRAM REQUIRED WPB AMENDMENTS TO THE FBC | | | SEC. 107.3.5.3 (12) RESIDENTIAL GAS. | | | | | | 7. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. TYPE OF GAS (LP OR NATURAL). WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 9. SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC FUEL GAS RES. SEC. | | | G2420.4. | | | | | | 10. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2017 FBC | | | FUEL GAS SEC. 402.4.1 OR 2017 FBC FUEL GAS RES. SEC. | | | G2413.4.1. | | | | | | 11. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC FUEL GAS | | | RES. SEC. G2413. | | | | | | 12. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE, | | | TERMINATION POINT, HEIGHT ABOVE THE ROOF AND ANCHORING | | | DETAILS OF THE GAS VENT(S) PER 2017 FBC FUEL GAS SECS. | | | 502 THRU 505 OR 2017 FBC FUEL GAS RES. SECS. G2426 THRU | | | G2429.1 | | | | | | 13. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR ANOTHER STANDARD THAT WAS USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC FUEL | | | GAS RES. SEC. G2412.4, G2412.8, G2413.1, G2413.2, & | | | G2413.3. | | | | | | 14. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2017 FBC FUEL GAS RES. SEC. G2421.1. | | | | | | 15. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED | | | GAS APPLIANCES. WHERE IS COMBUSTION AIR PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR? 2017 FBC R | | | G2407.9.3. COMBINED COMBUSTION AIR AND VENTILATION AIR | | | SYSTEM. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-02 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-02 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2018-08-06 10:39:22 | IMPACT FEES ONLY, GIVEN TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-26 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-28 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2018-06-28 15:59:55 | R30 | | | *TRAVELLING WITH 18041175* |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-22 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-01 |
Time |
15:09 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-23 |
Time |
09:17 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-06 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-06 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2018-05-14 16:03:31 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-04-30 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-04-30 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-26 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-26 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2018-07-26 13:38:19 | 07/26/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-06-13 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-13 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-05-08 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-05-04 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2018-05-08 08:16:40 | 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS NOTE - A | | | COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME AND | | | ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED UPON | | | THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. THE PVC PIPE 4" IS SHOWN (A-3) IN THE PLUMBING | | | ISOMETRIC AND THE FIXTURE DRAIN WILL ALLOW THE PIPE TO | | | BE 3" BECAUSE OF WALL AND SPACE YOU MAY CONSIDER TO | | | CHANGE THEM ACCORDING TO WHAT CODE ALLOWS. UP STAIN ON | | | MAIN BUILDING YOU HAVE A WASHING MACHINE THAT SHOWS IT | | | WITH AN AIR ADMITTANCE VALVE AS PER MANUFACTURES | | | SPECIFICATION, IT REQUIRES A 3" SIZE PIPE ON AN AAV AND | | | IT IS RECOMMENDED BY MOST WASHING MACHINES MANUFACTURE | | | BECAUSE OF SOAP SUDS. | | | | | | 2. ROMAN TUB STANDALONE REQUIRED A CONTROL VALVE BY A | | | WATER TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3, EXCEPT WHERE SUCH PROTECTION IS | | | OTHERWISE PROVIDED BY A COMBINATION TUB/SHOWER VALVE IN | | | ACCORDANCE WITH SECTION P2708.4. FBC R 2713.3 BATHTUB | | | AND WHIRLPOOL BATHTUB VALVES. PLEASE SHOW LOCATION OR | | | NOTE ON THE PLAN. | | | | | | 3. ON SECOND BUILDING SHOW AN OUTSIDE SHOWER PLEASE | | | LABEL AND GIVE IT MORE DETAILS. IS THERE HOT WATER | | | COMING FROM THE MAIN HOUSE OR DOES THIS BUILDING HAS | | | ITS OWN WATER HEATER. IF COMING UNDERGROUND TO FEED HOT | | | WATER FROM THE MAIN HEATING SOURCE IT MUST BE INSULATED | | | WITH AN R-3 PER FBC RE 403.5.3 | | | | | | 4. PLUMBING WATER RISER DIAGRAM REQUIRED WPB AMENDMENTS | | | TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING | | | | | | 5. THE LOFT HAS A NOTE FOR FUTURE PLUMBING ON THE | | | SECOND FLOOR AND THERE IS A BATHROOM DOWN STAIR ON THE | | | FIRST FLOOR EACH BUILDING SHALL HAVE ITS OWN VENT | | | SYSTEM THOROUGH ROOF AND AN AIR ADMITTANCE VALVE WILL | | | NOT BE TO CODE. OPTION ONE IS TO VENT THE DOWNSTAIRS | | | BATH THROUGH THE ROOF AND LATER THE OTHER BATHROOM MAY | | | BE INSTALLED OR PLUMB THE 2ND-FLOOR BATHROOM SO THE | | | SYSTEM IS ALL DONE AT THAT POINT. THE VENT SYSTEM | | | SERVING EACH BUILDING DRAIN SHALL HAVE NOT LESS THAN | | | ONE VENT PIPE THAT EXTENDS TO THE OUTDOORS. 2017 FBC R | | | 3102.1 REQUIRED VENT EXTENSION. | | | | | | 6. GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE AT THIS TIME. A GAS PLAN REVIEW | | | HAS NOT BEEN PERFORMED AT THIS TIME. A SEPARATE GAS | | | PERMIT AND PLANS WILL BE REQUIRED FOR A CONTRACTOR TO | | | PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS AND | | | GAS RISER THAT REFLECTS THE ENTIRE SCOPE OF GAS WORK TO | | | BE DONE. WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-06 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-06 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-22 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-22 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2018-06-22 12:54:15 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ROOFING COMMENTS: | | | | | | 16.[FBC R903.2.1] SUBMIT FLASHING TYPE, GAGE AND | | | ATTACHMENT DETAILS. PROVIDE SCUPPER DETAIL, SIZE AND | | | ROOF AREA CALCULATION FOR FLAT ROOF DRAINAGE. | | | | | | 17.[FBC R903.4]PROVIDE DRAINAGE SLOPE FOR FLAT ROOF. | | | | | | 18.[FBC R905.3.8]SUBMIT FLASHING TYPE AND ATTACHMENT | | | FOR CLAY TILE ROOF. | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF ADDITIONAL MATERIALS REQUESTED. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-14 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-14 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-07-17 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-06-12 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
LL |
Date |
2018-05-02 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-02 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |