Plan Review Details - Permit 18041013
Plan Review Stops For Permit 18041013
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-07-05 Cont ID  
Sent By skennedy Date 2018-07-05 Time 14:41 Rev Time 0.00
Received By skennedy Date 2018-07-05 Time 14:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-05-27 Cont ID  
Sent By cthroop Date 2018-05-27 Time 12:03 Rev Time 0.00
Received By shill Date 2018-05-27 Time 12:03 Sent To  
Notes
2018-05-27 12:16:02****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 NOTE - ALTHOUGH THE IMPROVEMENTS HAVE BEEN INSTALLED
 WITHOUT A PERMIT, COMMENT LIST REFERS TO IMPROVEMENTS
 AS "PROPOSED". AN IMPROVEMENT BECOMES "EXISTING" WHEN A
 PERMIT IS ISSUED, CONSTRUCTION INSPECTED, AND FINAL
 INSPECTIONS OBTAINED.
  
 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED
 SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID.
  
 2. AS THE ORIGINAL PERMIT WAS FOR "TEMPORARY
 CONSTRUCTION TRAILERS" WHICH ARE EXEMPT FROM FLORIDA
 BUILDING CODE, BUT ACTUAL USE IS AS A BAR
 (18021163/18041013), COMPLIANCE WITH ALL REQUIREMENTS
 OF THE FLORIDA BUILDING IS REQUIRED. A DESIGN
 PROFESSIONAL IS REQUIRED TO PROVIDE ALL INFORMATION,
 FS481. A SKETCH AND "MODSPACE" DRAWING WERE PROVIDED;
 THIS CANNOT BE USED TO DEMONSTRATE CODE COMPLIANCE. AN
 INCOMPLETE "LIFE SAFETY PLAN" WAS SUBMITTED; PLEASE
 REVISE THIS PLAN TO ADDRESS COMMENTS, OR HAVE ANOTHER
 DESIGN PROFESSIONAL PREPARE A PLAN.
  
 3. CONTACT PALM BEACH COUNTY IMPACT FEES, 561-233-5025.
 THEY WILL DETERMINE WHETHER OR NOT IMPACT FEES ARE
 REQUIRED. IF AN IMPACT FEE ASSESSMENT IS NOT REQUIRED,
 THEY CAN VERIFY THIS VIA EMAIL. IF THEY REQUIRE A
 REVIEW, AFTER ALL REVIEWS HAVE PASSED AND PLANS ARE
 STAMPED, TAKE THE PLANS TO PALM BEACH COUNTY. THE PLANS
 ARE TO BE STAMPED BY THEM AND THE RECEIPT SHOWING THAT
 FEES DUE WERE PAID, IF APPLICABLE, ARE TO BE PROVIDED
 TO BUILDING DIVISION.
  
 3. THE DCA APPROVAL WAS PROVIDED FOR THIS PERMIT AND IS
 NOT REQUIRED TO BE PROVIDED AGAIN. USE IS NOT
 CONSISTENT WITH THE MODULAR PLAN WHICH SHOWS THIS AS
 BUSINESS WITH OFFICES. DESIGN PROFESSIONAL IS TO
 PROVIDE A PLAN WHICH SHOWS COMPLIANCE WITH NEW
 USE/OCCUPANCY, FBC CHAPTER 3.
  
 DESIGN PROFESSIONAL IS TO DETERMINE PROPOSED OCCUPANCY
 CLASSIFICATION, OCCUPANT LOAD. AS PROPOSED USE IS NOT
 CONSISTENT WITH THE DCA APPROVAL, MODIFICATIONS MAY BE
 REQUIRED IF DCA MODULAR WAS NOT DESIGNED FOR USE AS A
 BAR.
  
 4. REVISE SITE PLAN OR OTHER PLAN TO SHOW BUILDING TYPE
 (FBC CHAPTER 6), BUILDING AREA TO SHOW COMPLIANCE WITH
 FBC B CHAPTER 5.
  
 5. A PLAN WAS PROVIDED; IT APPEARS THAT THE DCA MODULAR
 WAS MODIFIED. PROVIDE A PLAN SHOWING WHAT WORK WAS DONE
 TO ADAPT A MODULAR DESIGNED AS BUSINESS TO A BAR, FBC
 107.
  
 6. PROVIDE A DETAIL FOR THE BAR WHICH SHOWS COMPLIANCE
 WITH FBC A 902.
  
 7. THE PLAN SHOWS A "LIVING AREA"; PROVIDE A PLAN WHICH
 CLEARLY SHOWS USE OF ALL SPACES, FBC 107.
  
 8. IT IS NOT CLEAR HOW THE PROPOSED DECK COMPLIES WITH
 FBC ACCESSIBLILITY. ARE THE BOARDS T&G? HOW LARGE ARE
 THE GAPS, SEE FBC A 302.3. A STRUCTURAL PLAN WAS
 PROVIDED, BUT AN ARCHITECTURAL TYPE PLAN IS REQUIRED TO
 SHOW COMPLIANCE WITH ACCESSIBLE ROUTE AND DECK LAYOUT.
 WHICH DIRECTION ARE THE BOARDS INSTALLED AT THE RAMP
 TURNS; IT APPEARS THAT THE USER WILL TRAVEL IN BOTH
 DIRECTIONS TO MAKE THE TURN, NOT CLEAR HOW BOARDS WILL
 COMPLY.
  
 9. PROVIDE PLANS FOR THE PROPOSED DECK: FLOOR PLAN,
 SECTIONS, DETAIL TO SHOW ELEVATION CHANGE AT DOORS, FBC
 107.
  
 10. A VALUE OF $0 WAS PROVIDED FOR THIS REVISION. A
 VALUE OF $10K WAS PROVIDED AT TIME OF PERMIT ISSUANCE
 FOR A TEMPORARY CONSTRUCTION TRAILER. PROVIDE CONTRACT
 AMOUNT, FBC 109. IF AMOUNT EXCEEDS THE AMOUNT IN THE
 ICC VALUATION TABLES, A VALUE ADJUSTMENT TO THE TABLES
 WILL BE DONE AFTER OCCUPANCY CLASSIFICATION AND
 BUILDING TYPE ARE DETERMINED.
  
 11. PRIOR TO RESUBMITTING, PLEASE SCHEDULE AN
 APPOINTMENT FOR A PRE-SCREEN TO ENSURE THAT ALL
 INFORMATION REQUIRED IS PROVIDED. IF THIS IS A CHANGE
 OF OCCUPANCY (FROM BUSINESS TO ANOTHER OCCUPANCY),
 PLEASE ADVISE.
  
 12. ALL THREE REVISIONS INDICATE THAT "DECKING DETAIL"
 IS INCLUDED IN SCOPE. CLARIFY. THE DECK WHICH CONNECTS
 THE STRUCTURES SHOULD BE INCLUDED ON ONE OF THE
 REVISIONS OR BE A SEPARATE PERMIT.
  
 13. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 FS471. DCA MODULAR PLANS ARE ON FILE WITH THE STATE, SO
 SIGNED AND SEALED ORIGINALS SHOULD NOT BE SUBMITTED
 (DCA PLANS ONLY), BUT THE STATE APPROVED STAMPED PLANS
 FROM THE WEBSITE SHOULD BE SUBMITTED.
  
 14. AN OVERALL LIFE SAFETY PLAN IS REQUIRED, FBC B
 CHAPTER 10, WHICH SHOWS COMPLIANCE WITH EXIT DISCHARGE
 (FROM EXIT DOORS, ACROSS THE DECK, TO STAIRS/RAMPS). IT
 IS NOT CLEAR HOW MANY MEANS OF EGRESS ARE REQUIRED AND
 ACCESSIBLE MEANS OF EGRESS (ONE RAMP OR TWO RAMPS). THE
 DECK, IF USED FOR SEATING, IS TO BE INCLUDED. NUMBER OF
 OCCUPANTS PER MODULAR, DECK, WHICH NEED TO UTILIZE THE
 RAMPS AND STAIRS IS NOT CLEAR.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2018-07-05 Cont ID  
Sent By skennedy Date 2018-07-05 Time 14:41 Rev Time 0.00
Received By skennedy Date 2018-07-05 Time 14:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-05-30 Cont ID  
Sent By jleahy Date 2018-05-30 Time 12:45 Rev Time 0.00
Received By jleahy Date 2018-05-30 Time 12:45 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-07-06 Cont ID  
Sent By scaldero Date 2018-07-06 Time 10:47 Rev Time 0.00
Received By scaldero Date 2018-07-06 Time 10:38 Sent To I
Notes
2018-07-06 10:47:23PERMIT # 18041013
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) PER PLANS PROVIDED, OCCUPANCY LOAD OF EACH TRAILER
 IS 14 PERSONS, MAXIMUM. ALTERATIONS TO THIS OCCUPANCY
 LOAD SHALL BE REQUESTED IN WRITING, AND SUBMITTED TO
 THE OFFICE OF THE FIRE MARSHAL FOR APPROVAL.
  
 2) PER PLANS PROVIDED, THE "INTENDED OCCUPANCY LOAD" OF
 THE DECK AREA IS SET AT 65 PERSONS AND IS HEREBY THE
 APPROVED OCCUPANCY LOAD. THE "DESIGNED OCCUPANCY LOAD"
 OF 190 PERSONS DOES NOT APPEAR TO COMPLY WITH ANY OF
 THE OCCUPANT LOAD FACTORS AS LISTED UNDER NFPA 101,
 CHAPTER 7. OCCUPANT LOAD OF 190 IS NOT APPROVED.
  
 3) THE PROVIDED SEATING/FURNITURE PLAN OF 4 TABLES AND
 16 CHAIRS IS THE APPROVED FURNITURE PLAN FOR THE DECK
 AREA. ALTERATIONS TO THIS FURNITURE PLAN SHALL BE
 REQUESTED IN WRITING, AND SUBMITTED TO THE OFFICE OF
 THE FIRE MARSHAL FOR APPROVAL.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-05-10 Cont ID  
Sent By scaldero Date 2018-05-10 Time 13:40 Rev Time 0.00
Received By scaldero Date 2018-05-10 Time 13:30 Sent To B
Notes
2018-05-10 13:40:18PERMIT # 18041013
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FAILED COMMENTS:
  
 1) THE WOOD PLATFORM CURRENTLY IN PLACE TO CONNECT ALL
 THREE TRAILERS IS CONSIDERED A STRUCTURE AND THEREFORE,
 DOES NOT MEET THE SEPERATION REQUIREMENTS OF THE CODE
 REFERENCED BELOW.
 PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION,
 ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2:
 TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF
 COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE
 CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS,
 TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1.
 PER TABLE 4.2.1:
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 2) PLEASE PROVIDE THE DETAILS REGARDING THE MATERIAL
 USED FOR THE PLATFORM. IS THE MATERIAL FIRE RETARDENT
 OR HAS IT BEEN TREATED WITH FIRE RETARDENT? PLEASE
 INCLUDE THE MANUFACTURER'S SPECIFICATIONS FOR THE
 MATERIAL AND/OR THE FIRE RETARDENT USED.
  
 3)A FIRE FINAL (131) INSPECTION IS REQUIRED FOR THIS
 PERMIT. BECAUSE THE TRAILER IS ALREADY INSTALLED AND IN
 USE, THE INSPECTION SHALL BE SCHEDULED (VIA THE
 AUTOMATED PERMIT SCHEDULING SYSTEM) IMMEDIATELY UPON
 ISSUANCE OF THIS PERMIT.
  
 4) THE MASTER PERMIT (18021163) IS FOR THE INSTALLATION
 OF A CONSTRUCTION TRAILER. THERE IS NO PERMIT ISSUED
 FOR THE INSTALLATION OF THE 76X48 FOOT PLATFORM. PLEASE
 ENSURE THAT IF ONE IS REQUIRED, PER THE FBC, THAT IT IS
 APPLIED FOR AND OBTAINED.
  
 5) THIS OCCUPANCY REQUIRES TWO MEANS OF EGRESS. ON
 APRIL 12, 2018, A SITE VISIT WAS CONDUCTED AND IT WAS
 OBSERVED THAT THE REAR EMERGENCY EXIT FOR THIS TRAILER
 WAS NOT PROPERLY IDENTIFIED BY THE REQUIRED EGRESS
 SIGNAGE.
 ADDITIONALLY, THE STAIRS WERE NOT INSTALLED TO CODE AND
 REQUIRED CORRECTION. PLEASE ENSURE THAT THESE ITEMS ARE
 CORRECTED IMMEDIATELY, IF ALREADY IN USE.
  
 6) PLEASE PROVIDE THE OCCUPANT LOAD CALCULATION AND
 TOTAL OCCUPANT LOAD FOR THIS TRAILER. PLEASE NOTE THAT
 OCCUPANCY EXCEEDING 49 PERSONS REQUIRES PANIC HARDWARE
 ON ALL MEANS OF EGRESS DOORS.
  
 7) EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS
 SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A
 CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM.
 SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-05-30 Cont ID  
Sent By jleahy Date 2018-05-30 Time 12:45 Rev Time 0.00
Received By jleahy Date 2018-04-23 Time 12:47 Sent To  
Notes
2018-05-27 12:26:315/27 TO TIM LARGE DESK
  
2018-04-24 12:47:56REVISION ROUTED TO ZONING INBOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2018-07-05 Cont ID  
Sent By skennedy Date 2018-07-05 Time 14:42 Rev Time 0.00
Received By skennedy Date 2018-07-05 Time 14:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-05-29 Cont ID  
Sent By ccole Date 2018-05-29 Time 15:58 Rev Time 0.00
Received By ccole Date 2018-05-29 Time 15:53 Sent To  
Notes
2018-05-29 16:35:141ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18041013
 5/29/18
  
 CODES IN EFFECT:
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC-SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE COMPLETE MECHANICAL PLANS FOR THE NEW BAR
 TRAILER INCLUDING:
  
 MINIMUM VENTILATION CALCULATIONS- TABLE 403.1.1 FBC M.
 AC COOLING AND HEATING CALCULATIONS- SECTION 403.2.1
 FBC EC.
 AC EQUIPMENT SCHEDULE- C403.1 FBC EC
 AC DUCT LAYOUT PLAN- 601.1 FBC M
 ENERGY CALCULATIONS- SECTION C401.2 FBC EC
 EQUIPMENT SCHEDULES FOR THE NEW COOLERS- 1101.2 FBC M
 WINDLOAD ENGINEERING FOR INSTALLATION OF ALL EXTERIOR
 MECHANICAL EQUIPMENT OR APPLIANCES- 301.15 FBC M.
  
 2) PLEASE REFER TO FLORIDA ADMINISTRATIVE CODESECTION
 9B-1.011 ALTERATIONS AND RELOCATION, ITEMS 1-5 AS THEY
 RELATE TO THE ONSITE WORK PERFORMED ON THE TRAILER. IN
 ACCORDANCE WITH ITEM #3 THE ALTERED TRAILER SHALL
 COMPLY WITH THE CURRENT FLORIDA BUILDING CODES IN
 EFFECT AND COMPLETE INSPECTIONS OF ALL MODIFICATIONS
 MUST BE PERFORMED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2018-07-05 Cont ID  
Sent By skennedy Date 2018-07-05 Time 14:42 Rev Time 0.00
Received By skennedy Date 2018-07-05 Time 14:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-05-30 Cont ID  
Sent By tklarge Date 2018-05-30 Time 12:06 Rev Time 0.00
Received By tklarge Date 2018-05-29 Time 06:27 Sent To  
Notes
2018-05-30 10:26:35 
 1) SHT. A100 - THE PLAN REFERS TO THE EPCOT
 ACCESSIBILITY CODE AND THE EPCOT BUILDING CODE. HOW ARE
 THESE CODES APPLICABLE TO THIS PROJECT? CLARIFY.
  
 2.) AS THE ORIGINAL PERMIT WAS FOR "TEMPORARY
 CONSTRUCTION TRAILERS" WHICH ARE EXEMPT FROM FLORIDA
 BUILDING CODE, BUT ACTUAL USE IS AS A BAR
 (18021163/18041013), COMPLIANCE WITH ALL REQUIREMENTS
 OF THE FLORIDA BUILDING IS REQUIRED. A DESIGN
 PROFESSIONAL IS REQUIRED TO PROVIDE ALL INFORMATION,
 FS481. A SKETCH AND "MODSPACE" DRAWING WERE PROVIDED;
 THIS CANNOT BE USED TO DEMONSTRATE CODE COMPLIANCE. AN
 INCOMPLETE "LIFE SAFETY PLAN" WAS SUBMITTED; PLEASE
 REVISE THIS PLAN TO ADDRESS COMMENTS, OR HAVE ANOTHER
 DESIGN PROFESSIONAL PREPARE A PLAN.
  
 3.) PROVIDE DOCUMENTATION OF DBPR APPROVAL FOR THIS
 MODULAR STRUCTURE. 2017 FBC SEC. 458.4.2.
  
 4) SHT. A100 - THE DESIGN PROFESSIONAL IS TO DETERMINE
 PROPOSED OCCUPANCY CLASSIFICATION, OCCUPANT LOAD. AS
 PROPOSED USE IS NOT CONSISTENT WITH THE DCA APPROVAL,
 MODIFICATIONS MAY BE REQUIRED IF DCA MODULAR WAS NOT
 DESIGNED FOR USE AS A BAR.
  
 5.) A PLAN WAS PROVIDED; IT APPEARS THAT THE DCA
 MODULAR WAS MODIFIED. PROVIDE A PLAN SHOWING WHAT WORK
 WAS DONE TO ADAPT A MODULAR DESIGNED AS BUSINESS TO A
 BAR, FBC 107.
  
 6.) PROVIDE A DETAIL FOR THE BAR WHICH SHOWS COMPLIANCE
 WITH FBC-ACCESS. SEC. 902.
  
 7.) A VALUE OF $0 WAS PROVIDED FOR THIS REVISION.
 PROVIDE CONTRACT AMOUNT, FBC 109.
  
 8). DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 PER F.A.C. RULE 61G15-23.001. DCA MODULAR PLANS ARE ON
 FILE WITH THE STATE, SO SIGNED AND SEALED ORIGINALS
 SHOULD NOT BE SUBMITTED (DCA PLANS ONLY), BUT THE STATE
 APPROVED STAMPED PLANS FROM THE WEBSITE SHOULD BE
 SUBMITTED.
  
 9) A GREASE CONTROL DEVICE WILL BE REQUIRED FOR THE
 SINKS IN THE BAR AREA PER 2017 FBC-PLUMBING SEC.
 1003.1.
  
 10) SHOW THE LENGTH AND WIDTH DIMENSIONS OF THE TOILET
 ROOM. WPB AMEND. TO FBC SEC. 107.2.1.
  
 11) SHOW THE REQUIRED CLEAR SPACES FOR THE WATER CLOSET
 AND THE LAVATORY ON THE PLANS. COMPLY WITH 2017
 FBC-ACCESS. SECS. 604.3, 606.2.
  
 12) SHOW THE REQUIRED FIXTURE CLEARANCES PER THE 2017
 FBC-PLUMBING AND FBC-ACCESS. SEC.604.2.
  
 13) SUBMIT ELEVATION DETAILS FOR ALL THE HANDICAP
 ACCESSIBILITY COMPONENTS IN THE TOILET ROOM (GRAB BARS,
 HEIGHT OF WATER CLOSET AND LAVATORY, TOILET PAPER
 DISPENSER, MIRROR, ETC.)
  
 14) THE LAVATORY SHALL BE PROVIDED WITH KNEE AND TOE
 CLEARANCE PER 2017 FBC SEC.306.
  
 15) SHOW THE REQUIRED TURNING SPACE IN THE TOILET ROMM
 PER 2017 FBC-ACCESS. SEC.304.
  
 16) AT LEAST 5 PERCENT OF THE TABLES SHALL COMPLY WITH
 SEC. 902 OF 2017 FBC-ACCESS.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
  
  

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By pgreilic Date 2018-05-01 Time   Rev Time 0.00
Received By pgreilic Date 2018-05-01 Time 14:27 Sent To FIRE
Notes
2018-05-01 14:28:13PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]